977 resultados para Non-conventional basins
Resumo:
The objective was to compare the prevalence of subclinical mastitis (SM) and of udder pathogens in 60 Swiss organic (OP) and 60 conventional production systems (CP). Cows (n=970) were studied for SM prevalence and udder pathogens at median 31 d and 102 d post partum. Cows showing a >/=1+ positive California Mastitis Test (CMT) in at least one quarter were considered to have SM. Cow-level prevalences of SM for visits at 31 d and 102 d post partum (39% and 40% in OP and 34% and 35% in CP) were similar, but quarter-level prevalences of SM were higher (P<0.02) in OP than CP (15% and 18% in OP and 12% and 15% in CP). Median somatic cell counts in milk at 31 d post partum were higher (P<0.05) in OP than CP cows (43000 and 28000 cells/ml, respectively), but were similar at 102 d post partum in OP and CP cows (45000 and 38000 cells/ml, respectively). In milk samples from quarters showing a CMT reaction >/=2+ the prevalences of coagulase negative staphylococci were lower (P<0.05) at 102 d post partum, whereas prevalences of non-agalactiae streptococci were higher (P<0.05) in OP than in CP cows at 31 d and 102 d post partum. In conclusion, under Swiss conditions, subclinical mastitis is a greater problem in organic than in conventional production systems, but differences are not marked.
Resumo:
Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.
Resumo:
OBJECTIVE: Patient-ventilator synchrony during non-invasive pressure support ventilation with the helmet device is often compromised when conventional pneumatic triggering and cycling-off were used. A possible solution to this shortcoming is to replace the pneumatic triggering with neural triggering and cycling-off-using the diaphragm electrical activity (EA(di)). This signal is insensitive to leaks and to the compliance of the ventilator circuit. DESIGN: Randomized, single-blinded, experimental study. SETTING: University Hospital. PARTICIPANTS AND SUBJECTS: Seven healthy human volunteers. INTERVENTIONS: Pneumatic triggering and cycling-off were compared to neural triggering and cycling-off during NIV delivered with the helmet. MEASUREMENTS AND RESULTS: Triggering and cycling-off delays, wasted efforts, and breathing comfort were determined during restricted breathing efforts (<20% of voluntary maximum EA(di)) with various combinations of pressure support (PSV) (5, 10, 20 cm H(2)O) and respiratory rates (10, 20, 30 breath/min). During pneumatic triggering and cycling-off, the subject-ventilator synchrony was progressively more impaired with increasing respiratory rate and levels of PSV (p < 0.001). During neural triggering and cycling-off, effect of increasing respiratory rate and levels of PSV on subject-ventilator synchrony was minimal. Breathing comfort was higher during neural triggering than during pneumatic triggering (p < 0.001). CONCLUSIONS: The present study demonstrates in healthy subjects that subject-ventilator synchrony, trigger effort, and breathing comfort with a helmet interface are considerably less impaired during increasing levels of PSV and respiratory rates with neural triggering and cycling-off, compared to conventional pneumatic triggering and cycling-off.
Resumo:
Fish behaviourists are increasingly turning to non-invasive measurement of steroid hormones in holding water, as opposed to blood plasma. When some of us met at a workshop in Faro, Portugal, in September, 2007, we realised that there were still many issues concerning the application of this procedure that needed resolution, including: Why do we measure release rates rather than just concentrations of steroids in the water? How does one interpret steroid release rates when dealing with fish of different sizes? What are the merits of measuring conjugated as well as free steroids in water? In the ‘static’ sampling procedure, where fish are placed in a separate container for a short period of time, does this affect steroid release—and, if so, how can it be minimised? After exposing a fish to a behavioural stimulus, when is the optimal time to sample? What is the minimum amount of validation when applying the procedure to a new species? The purpose of this review is to attempt to answer these questions and, in doing so, to emphasize that application of the non-invasive procedure requires more planning and validation than conventional plasma sampling. However, we consider that the rewards justify the extra effort.
Resumo:
The South Florida Water Management District (SFWMD) manages and operates numerous water control structures that are subject to scour. In an effort to reduce scour downstream of these gated structures, laboratory experiments were performed to investigate the effect of active air-injection downstream of the terminal structure of a gated spillway on the depth of the scour hole. A literature review involving similar research revealed significant variables such as the ratio of headwater-to-tailwater depths, the diffuser angle, sediment uniformity, and the ratio of air-to-water volumetric discharge values. The experimental design was based on the analysis of several of these non-dimensional parameters. Bed scouring at stilling basins downstream of gated spillways has been identified as posing a serious risk to the spillway’s structural stability. Although this type of scour has been studied in the past, it continues to represent a real threat to water control structures and requires additional attention. A hydraulic scour channel comprised of a head tank, flow straightening section, gated spillway, stilling basin, scour section, sediment trap, and tail-tank was used to further this analysis. Experiments were performed in a laboratory channel consisting of a 1:30 scale model of the SFWMD S65E spillway structure. To ascertain the feasibility of air injection for scour reduction a proof-of-concept study was performed. Experiments were conducted without air entrainment and with high, medium, and low air entrainment rates for high and low headwater conditions. For the cases with no air entrainment it was found that there was excessive scour downstream of the structure due to a downward roller formed upon exiting the downstream sill of the stilling basin. When air was introduced vertically just downstream of, and at the same level as, the stilling basin sill, it was found that air entrainment does reduce scour depth by up to 58% depending on the air flow rate, but shifts the deepest scour location to the sides of the channel bed instead of the center. Various hydraulic flow conditions were tested without air injection to verify which scenario caused more scour. That scenario, uncontrolled free, in which water does not contact the gate and the water elevation in the stilling basin is lower than the spillway crest, would be used for the remainder of experiments testing air injection. Various air flow rates, diffuser elevations, air hole diameters, air hole spacings, diffuser angles and widths were tested in over 120 experiments. Optimal parameters include air injection at a rate that results in a water-to-air ratio of 0.28, air holes 1.016mm in diameter the entire width of the stilling basin, and a vertically orientated injection pattern. Detailed flow measurements were collected for one case using air injection and one without. An identical flow scenario was used for each experiment, namely that of a high flow rate and upstream headwater depth and a low tailwater depth. Equilibrium bed scour and velocity measurements were taken using an Acoustic Doppler Velocimeter at nearly 3000 points. Velocity data was used to construct a vector plot in order to identify which flow components contribute to the scour hole. Additionally, turbulence parameters were calculated in an effort to help understand why air-injection reduced bed scour. Turbulence intensities, normalized mean flow, normalized kinetic energy, and anisotropy of turbulence plots were constructed. A clear trend emerged that showed air-injection reduces turbulence near the bed and therefore reduces scour potential.
Resumo:
An electrospray source has been developed using a novel new fluid that is both magnetic and conductive. Unlike conventional electrospray sources that required microfabricated structures to support the fluid to be electrosprayed, this new electrospray fluid utilizes the Rosensweig instability to create the structures in the magnetic fluid when an external magnetic field was applied. Application of an external electric field caused these magnetic fluid structures to spray. These fluid based structures were found to spray at a lower onset voltage than was predicted for electrospray sources with solid structures of similar geometry. These fluid based structures were also found to be resilient to damage, unlike the solid structures found in traditional electrospray sources. Further, experimental studies of magnetic fluids in non-uniform magnetic fields were conducted. The modes of Rosensweig instabilities have been studied in-depth when created by uniform magnetic fields, but little to no studies have been performed on Rosensweig instabilities formed due to non-uniform magnetic fields. The measured spacing of the cone-like structures of ferrofluid, in a non-uniform magnetic field, were found to agree with a proposed theoretical model.
Resumo:
Data of the strength of Earth’s magnetic field (paleointensity) in the geological past are crucial for understanding the geodynamo. Conventional paleointensity determination methods require heating a sample to a high temperature in one or more steps. Consequently, many rocks are unsuitable for these methods due to a heating-induced experimental alteration. Alternative non-heating paleointensity methods are investigated to assess their effectiveness and reliability using both natural samples from Lemptégy Volcano, France, and synthetic samples. Paleointensity was measured from the natural and synthetic samples using the Pseudo-Thellier, ARM, REM, REMc, REM’, and Preisach methods. For the natural samples, only the Pseudo-Thellier method was able to produce a reasonable paleointensity estimate consistent with previous paleointensity data. The synthetic samples yielded more successful estimates using all the methods, with the Pseudo-Thellier and ARM methods producing the most accurate results. The Pseudo-Thellier method appears to be the best alternative to the heating-based paleointensity methods.
Resumo:
Phagocytosis of fine particles (1 mum) by macrophages is a ligand-receptor-mediated, actin-based process, whereas the entering of smaller particles (= 0.2 mum) in macrophages occurs also by other mechanisms. Virosomes with a diameter of 0.12-0.18 mum are widely used as carrier systems for drugs, vectors, and plasmids in cancer therapy or for vaccines. We investigated their interactions with airway cells, in particular penetration into monocyte-derived macrophages. The microscopic analysis of phagocytic cells incubated with virosomes and polystyrene particles showed that virosomes and particles penetrated cells even in the presence of cytochalasin D, a drug inhibiting actin-based phagocytosis. The charge of the virosomes and particles did not influence their penetration. Also, different inhibitors of endocytotic pathways did not prevent the particles and virosomes from penetrating into the cells. Additionally, to study the ability of virosomes to overcome the epithelial airway barrier, a triple cell co-culture model composed of epithelial cells, monocyte-derived macrophages and dendritic cells of the respiratory tract was used. We found virosomes and polystyrene particles in both populations of antigen-presenting cells, monocyte-derived macrophages, and dendritic cells, in the latter even if they were not directly exposed. In conclusion, virosomes are readily taken up by monocyte-derived macrophages, both by conventional phagocytosis and by actin-independent mechanisms. Further, they can penetrate the airway barrier and reach resident dendritic cells. Therefore, virosomes are promising vaccine candidates.
Resumo:
BACKGROUND: A precise, non-invasive, non-toxic, repeatable, convenient and inexpensive follow-up of renal transplants, especially following biopsies, is in the interest of nephrologists. Formerly, the rate of biopsies leading to AV fistulas had been underestimated. Imaging procedures suited to a detailed judgement of these vascular malformations are to be assessed. METHODS: Three-dimensional (3D) reconstruction techniques of ultrasound flow-directed and non-flow-directed energy mode pictures were compared with a standard procedure, gadolinium-enhanced nuclear magnetic resonance imaging angiography (MRA) using the phase contrast technique. RESULTS: Using B-mode and conventional duplex information, AV fistulas were localized in the upper pole of the kidney transplant of the index patient. The 3D reconstruction provided information about the exact localization and orientation of the fistula in relation to other vascular structures, and the flow along the fistula. The MRA provided localization and orientation information, but less functional information. Flow-directed and non-flow-directed energy mode pictures could be reconstructed to provide 3D information about vascular malformations in transplanted kidneys. CONCLUSION: In transplanted kidneys, 3D-ultrasound angiography may be equally as effective as MRA in localizing and identifying AV malformations. Advantages of the ultrasound method are that it is cheaper, non-toxic, non-invasive, more widely availability and that it even provides more functional information. Future prospective studies will be necessary to evaluate the two techniques further.
Resumo:
STUDY QUESTION Is the steroid hormone profile in follicular fluid (FF) at the time of oocyte retrieval different in naturally matured follicles, as in natural cycle IVF (NC-IVF), compared with follicles stimulated with conventional gonadotrophin stimulated IVF (cIVF)? SUMMARY ANSWER Anti-Mullerian hormone (AMH), testosterone (T) and estradiol (E2) concentrations are ∼3-fold higher, androstenedione (A2) is ∼1.5-fold higher and luteinizing hormone (LH) is ∼14-fold higher in NC-IVF than in cIVF follicles, suggesting an alteration of the follicular metabolism in conventional gonadotrophin stimulated IVF. WHAT IS KNOWN ALREADY In conventional IVF, the implantation rate of unselected embryos appears to be lower than in NC-IVF, which is possibly due to negative effects of the stimulation regimen on follicular metabolism. In NC-IVF, the intrafollicular concentration of AMH has been shown to be positively correlated with the oocyte fertilization and implantation rates. Furthermore, androgen treatment seems to improve the ovarian response in low responders. STUDY DESIGN, SIZE, DURATION This cross-sectional study involving 36 NC-IVF and 40 cIVF cycles was performed from 2011 to 2013. Within this population, 13 women each underwent 1 NC-IVF and 1 cIVF cycle. cIVF was performed by controlled ovarian stimulation with HMG and GnRH antagonists. PARTICIPANTS/MATERIALS, SETTING, METHODS Follicular fluid was collected from the leading follicles. AMH, T, A2, dehydroepiandrosterone (DHEA), E2, FSH, LH and progesterone (P) were determined by immunoassays in 76 women. Aromatase activity in follicular fluid cells was analysed by a tritiated water release assay in 33 different women. For statistical analysis, the non-parametric Mann-Whitney U or Wilcoxon tests were used. MAIN RESULTS AND ROLE OF CHANCE In follicular fluid from NC-IVF and from cIVF, median levels were 32.8 and 10.7 pmol/l for AMH (P < 0.0001), 47.2 and 18.8 µmol/l for T (P < 0.0001), 290 and 206 nmol/l for A2 (P = 0.0035), 6.7 and 5.6 pg/ml for DHEA (n.s.), 3292 and 1225 nmol/l for E2 (P < 0.0001), 4.9 and 7.2 mU/ml for FSH (P < 0.05), 14.4 and 0.9 mU/ml for LH (P < 0.0001) and 62 940 and 54 710 nmol/l for P (n.s.), respectively. Significant differences in follicular fluid concentrations for AMH, E2 and LH were also found in the 13 patients who underwent both NC-IVF and cIVF when they were analysed separately in pairs. Hormone analysis in serum excluded any relevant impact of AMH, T, A2, and E2 serum concentration on the follicular fluid hormone concentrations. Median serum concentrations were 29.4 and 0.9 mU/ml for LH (P < 0.0001) and 2.7 and 23.5 nmol/l for P (P < 0.0001) after NC-IVF and c-IVF, respectively. Positive correlations were seen for FF-AMH with FF-T (r = 0.35, P = 0.0002), FF-T with FF-LH (r = 0.48, P < 0.0001) and FF-E2 with FF-T (r = 0.75, P < 0.0001). The analysis of aromatase activity was not different in NC-IVF and cIVF follicular cells. LIMITATION, REASONS FOR CAUTION Any association between the hormone concentrations and the implantation potential of the oocytes could not be investigated as the oocytes in cIVF were not treated individually in the IVF laboratory. Since both c-IVF and NC-IVF follicles were stimulated by hCG before retrieval, the endocrine milieu in the natural cycle does not represent the pure physiological situation. WIDER IMPLICATIONS OF THE FINDINGS The endocrine follicular milieu and the concentration of putative markers of oocyte quality, such as AMH, are significantly different in gonadotrophin-stimulated conventional IVF compared with natural cycle IVF. This could be a cause for the suggested lower oocyte quality in cIVF compared with naturally matured oocytes. The reasons for the reduced AMH concentration might be low serum and follicular fluid LH concentrations due to LH suppression, leading initially to low follicular androgen concentrations and then to low follicular AMH production. STUDY FUNDING/COMPETING INTERESTS Funding for this study was obtained from public universities (for salaries) and private industry (for consumables). Additionally, the study was supported by an unrestricted grant from MSD Merck Sharp & Dohme GmbH and IBSA Institut Biochimique SA. The authors are clinically involved in low-dose monofollicular stimulation and IVF therapies, using gonadotrophins from all gonadotrophin distributors on the Swiss market, including Institut Biochimique SA and MSD Merck Sharp & Dohme GmbH. Otherwise, the authors have no competing interests. TRIAL REGISTRATION NUMBER Not applicable.
Resumo:
AIM To investigate age- and gender-related differences in non-culprit versus culprit coronary vessels assessed with virtual histology intravascular ultrasound (VH-IVUS). METHODS In 390 patients referred for coronary angiography to a single center (Luzerner Kantonsspital, Switzerland) between May 2007 and January 2011, 691 proximal vessel segments in left anterior descending, circumflex and/or right coronary arteries were imaged by VH-IVUS. Plaque burden and plaque composition (fibrous, fibro-fatty, necrotic core and dense calcium volumes) were analyzed in 3 age tertiles, according to gender and separated for vessels containing non-culprit or culprit lesions. To classify as vessel containing a culprit lesion, the patient had to present with an acute coronary syndrome, and the VH-IVUS had to be performed in a vessel segment containing the culprit lesion according to conventional coronary angiography. RESULTS In non-culprit vessels the plaque burden increased significantly with aging (in men from 37% ± 12% in the lowest to 46% ± 10% in the highest age tertile, P < 0.001; in women from 30% ± 9% to 40% ± 11%, P < 0.001); men had higher plaque burden than women at any age (P < 0.001 for each of the 3 age tertiles). In culprit vessels of the lowest age tertile, plaque burden was significantly higher than that in non-culprit vessels (in men 48% ± 6%, P < 0.001 as compared to non-culprit vessels; in women 44% ± 18%, P = 0.004 as compared to non-culprit vessels). Plaque burden of culprit vessels did not significantly change during aging (plaque burden in men of the highest age tertile 51% ± 9%, P = 0.523 as compared to lowest age tertile; in women of the highest age tertile 49% ± 8%, P = 0.449 as compared to lowest age tertile). In men, plaque morphology of culprit vessels became increasingly rupture-prone during aging (increasing percentages of necrotic core and dense calcium), whereas plaque morphology in non-culprit vessels was less rupture-prone and remained constant during aging. In women, necrotic core in non-culprit vessels was very low at young age, but increased during aging resulting in a plaque morphology that was very similar to men. Plaque morphology in culprit vessels of young women and men was similar. CONCLUSION This study provides evidence that age- and gender-related differences in plaque burden and plaque composition significantly depend on whether the vessel contained a non-culprit or culprit lesion.
Resumo:
BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.
Resumo:
BACKGROUND/AIMS Clinical differentiation between organic hypersomnia and non-organic hypersomnia (NOH) is challenging. We aimed to determine the diagnostic value of sleepiness and performance tests in patients with excessive daytime sleepiness (EDS) of organic and non-organic origin. METHODS We conducted a retrospective comparison of the multiple sleep latency test (MSLT), pupillography, and the Steer Clear performance test in three patient groups complaining of EDS: 19 patients with NOH, 23 patients with narcolepsy (NAR), and 46 patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). RESULTS As required by the inclusion criteria, all patients had Epworth Sleepiness Scale (ESS) scores >10. The mean sleep latency in the MSLT indicated mild objective sleepiness in NOH (8.1 ± 4.0 min) and OSAS (7.2 ± 4.1 min), but more severe sleepiness in NAR (2.5 ± 2.0 min). The difference between NAR and the other two groups was significant; the difference between NOH and OSAS was not. In the Steer Clear performance test, NOH patients performed worst (error rate = 10.4%) followed by NAR (8.0%) and OSAS patients (5.9%; p = 0.008). The difference between OSAS and the other two groups was significant, but not between NOH and NAR. The pupillary unrest index was found to be highest in NAR (11.5) followed by NOH (9.2) and OSAS (7.4; n.s.). CONCLUSION A high error rate in the Steer Clear performance test along with mild sleepiness in an objective sleepiness test (MSLT) in a patient with subjective sleepiness (ESS) is suggestive of NOH. This disproportionately high error rate in NOH may be caused by factors unrelated to sleep pressure, such as anergia, reduced attention and motivation affecting performance, but not conventional sleepiness measurements.
Resumo:
BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. METHODS A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. RESULTS A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m(2) to -0.14 +/- 0.73 l/min/m(2). Additionally, data on practicality, limitations and clinical impact of the devices were collected. CONCLUSION The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.
Resumo:
Antibody-drug conjugates (ADCs) have emerged as a promising class of anticancer agents, combining the specificity of antibodies for tumor targeting and the destructive potential of highly potent drugs as payload. An essential component of these immunoconjugates is a bifunctional linker capable of reacting with the antibody and the payload to assemble a functional entity. Linker design is fundamental, as it must provide high stability in the circulation to prevent premature drug release, but be capable of releasing the active drug inside the target cell upon receptor-mediated endocytosis. Although ADCs have demonstrated an increased therapeutic window, compared to conventional chemotherapy in recent clinical trials, therapeutic success rates are still far from optimal. To explore other regimes of half-life variation and drug conjugation stoichiometries, it is necessary to investigate additional binding proteins which offer access to a wide range of formats, all with molecularly defined drug conjugation. Here, we delineate recent progress with site-specific and biorthogonal conjugation chemistries, and discuss alternative, biophysically more stable protein scaffolds like Designed Ankyrin Repeat Proteins (DARPins), which may provide such additional engineering opportunities for drug conjugates with improved pharmacological performance.