973 resultados para Microfluidic Analytical Techniques
Resumo:
Phenol is a toxic compound present in a wide variety of foundry resins. Its quantification is important for the characterization of the resins as well as for the evaluation of free contaminants present in foundry wastes. Two chromatographic methods, liquid chromatography with ultraviolet detection (LC-UV) and gas chromatography with flame ionization detection (GC-FID), for the analysis of free phenol in several foundry resins, after a simple extraction procedure (30 min), were developed. Both chromatographic methods were suitable for the determination of phenol in the studied furanic and phenolic resins, showing good selectivity, accuracy (recovery 99–100%; relative deviations <5%), and precision (coefficients of variation <6%). The used ASTM reference method was only found to be useful in the analysis of phenolic resins, while the LC and GC methods were applicable for all the studied resins. The developed methods reduce the time of analysis from 3.5 hours to about 30 min and can readily be used in routine quality control laboratories.
Resumo:
Mathematical models and statistical analysis are key instruments in soil science scientific research as they can describe and/or predict the current state of a soil system. These tools allow us to explore the behavior of soil related processes and properties as well as to generate new hypotheses for future experimentation. A good model and analysis of soil properties variations, that permit us to extract suitable conclusions and estimating spatially correlated variables at unsampled locations, is clearly dependent on the amount and quality of data and of the robustness techniques and estimators. On the other hand, the quality of data is obviously dependent from a competent data collection procedure and from a capable laboratory analytical work. Following the standard soil sampling protocols available, soil samples should be collected according to key points such as a convenient spatial scale, landscape homogeneity (or non-homogeneity), land color, soil texture, land slope, land solar exposition. Obtaining good quality data from forest soils is predictably expensive as it is labor intensive and demands many manpower and equipment both in field work and in laboratory analysis. Also, the sampling collection scheme that should be used on a data collection procedure in forest field is not simple to design as the sampling strategies chosen are strongly dependent on soil taxonomy. In fact, a sampling grid will not be able to be followed if rocks at the predicted collecting depth are found, or no soil at all is found, or large trees bar the soil collection. Considering this, a proficient design of a soil data sampling campaign in forest field is not always a simple process and sometimes represents a truly huge challenge. In this work, we present some difficulties that have occurred during two experiments on forest soil that were conducted in order to study the spatial variation of some soil physical-chemical properties. Two different sampling protocols were considered for monitoring two types of forest soils located in NW Portugal: umbric regosol and lithosol. Two different equipments for sampling collection were also used: a manual auger and a shovel. Both scenarios were analyzed and the results achieved have allowed us to consider that monitoring forest soil in order to do some mathematical and statistical investigations needs a sampling procedure to data collection compatible to established protocols but a pre-defined grid assumption often fail when the variability of the soil property is not uniform in space. In this case, sampling grid should be conveniently adapted from one part of the landscape to another and this fact should be taken into consideration of a mathematical procedure.
Resumo:
In the present study three techniques for obtaining outer membrane enriched fractions from Yersinia pestis were evaluated. The techniques analysed were: differential solubilization of the cytoplasmic membrane with Sarkosyl or Triton X-100, and centrifugation in sucrose density gradients. The sodium dodecyl-sulfate polyacrylamide gel electrophoresis (SDS-PAGE) of outer membrane isolated by the different methods resulted in similar protein patterns. The measurement of NADH-dehydrogenase and succinate dehydrogenase (inner membrane enzymes) indicated that the outer membrane preparations obtained by the three methods were pure enough for analytical studies. In addition, preliminary evidences on the potential use of outer membrane proteins for the identification of geographic variants of Y. pestis wild isolates are presented.
Resumo:
Dissertation submitted to Faculdade de Ciências e Tecnologia - Universidade Nova de Lisboa in fulfilment of the requirements for the degree of Doctor of Philosophy (Biochemistry - Biotechnology)
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
Background Over the years, food industry wastes have been the focus of a growing interest due to their content in high added-value compounds. A good example are the olive oil by-products (OOBP), which retain a great amount of phenolic compounds during olive oil production. Their structure and biological properties justify their potential use as antioxidants in other food products. The efficient recovery of phenolic compounds has been extensively studied and optimized in order to maximize their reintroduction in the food chain and contribute to a higher valorization and better management of wastes from olive oil industry. Scope and approach This paper reviews the most representative phenolic compounds described in OOBP and their biological properties. New extraction procedures to efficiently recover these compounds and the most advanced chromatographic techniques that have been used for a better understanding of the phenolic profile of these complex matrices are also referred. Finally, this paper reports the main applications of OOBP, with emphasis on their phenolic content as natural antioxidants for food applications. Key findings and conclusions Besides their antioxidant activity, phenolic compounds from OOBP have also shown antimicrobial and antitumoral properties. Their application as food antioxidants requires new extraction techniques, including the use of non-toxic solvents and, in a pilot scale, the use of filters and adsorbent resins. The inclusion of phenolic compounds from OOBP in some food matrices have improved not only their antioxidant capacity but also their sensory attributes.
Resumo:
The objective of this paper is to propose a simplified analytical approach to predict the flexural behavior of simply supported reinforced-concrete (RC) beams flexurally strengthened with prestressed carbon fiber reinforced polymer (CFRP) reinforcements using either externally bonded reinforcing (EBR) or near surface mounted (NSM) techniques. This design methodology also considers the ultimate flexural capacity of NSM CFRP strengthened beams when concrete cover delamination is the governing failure mode. A moment–curvature (M–χ) relationship formed by three linear branches corresponding to the precracking, postcracking, and postyielding stages is established by considering the four critical M–χ points that characterize the flexural behavior of CFRP strengthened beams. Two additional M–χ points, namely, concrete decompression and steel decompression, are also defined to assess the initial effects of the prestress force applied by the FRP reinforcement. The mid-span deflection of the beams is predicted based on the curvature approach, assuming a linear curvature variation between the critical points along the beam length. The good predictive performance of the analytical model is appraised by simulating the force–deflection response registered in experimental programs composed of RC beams strengthened with prestressed NSM CFRP reinforcements.
Resumo:
The use of chemical analysis of microbial components, including proteins, became an important achievement in the 80’s of the last century to the microbial identification. This led a more objective microbial identification scheme, called chemotaxonomy, and the analytical tools used in the field are mainly 1D/2D gel electrophoresis, spectrophotometry, high-performance liquid chromatography, gas chromatography, and combined gas chromatography-mass spectrometry. The Edman degradation reaction was also applied to peptides sequence giving important insights to the microbial identification. The rapid development of these techniques, in association with knowledge generated by DNA sequencing and phylogeny based on rRNA gene and housekeeping genes sequences, boosted the microbial identification to an unparalleled scale. The recent results of mass spectrometry (MS), like Matrix-Assisted Laser Desorption/Ionisation Time-of-Flight (MALDI-TOF), for rapid and reliable microbial identification showed considerable promise. In addition, the technique is rapid, reliable and inexpensive in terms of labour and consumables when compared with other biological techniques. At present, MALDI-TOF MS adds an additional step for polyphasic identification which is essential when there is a paucity of characters or high DNA homologies for delimiting very close related species. The full impact of this approach is now being appreciated when more diverse species are studied in detail and successfully identified. However, even with the best polyphasic system, identification of some taxa remains time-consuming and determining what represents a species remains subjective. The possibilities opened with new and even more robust mass spectrometers combined with sound and reliable databases allow not only the microbial identification based on the proteome fingerprinting but also include de novo specific proteins sequencing as additional step. These approaches are pushing the boundaries in the microbial identification field.
Resumo:
Se estudiarán los mecanismos de reacción electroquímica de las micotoxinas (metabolitos tóxicos generados por hongos) citrinina (CIT), patulina (PAT) y moniliformina (MON), de los antioxidantes naturales alfa, beta, gama y delta tocoferoles, de los flavonoides fisetina (FIS), morina (MOR), luteolina (LUT), rutina (RUT), buteina (BUT), naringenina (NAR) y miricetina (MIR) y de las hormonas esteroides estradiol (EDIOL), estrona (EONA) y estriol (ETRIOL). Por otra parte, se implementarán técnicas electroanalíticas para la detección y cuantificación de estos sustratos en muestras de matrices naturales que los contengan. Se realizará el diseño y caracterización de biosensores enzimáticos a partir de peroxidasas y/o fosfatasa alcalina para la determinación de la micotoxina CIT y de los flavonoides y, por otro, de inmunosensores para las micotoxinas ocratoxina A (OTA) y PAT y hormonas. Para el anclaje de enzimas y/o anticuerpos, se estudiarán las propiedades de electrodos modificados por monocapas autoensambladas, nanotubos de carbono y partículas magnéticas. Se usarán las técnicas de voltamperometría cíclica, de onda cuadrada y de redisolución con acumulación adsortiva, espectroscopías de impedancia electroquímica, electrólisis a potencial controlado, uv-vis e IR, microbalanza de cristal de cuarzo y microscopías de alta resolución (SEM, TEM, AFM). La importancia de este proyecto apunta a la obtención de nuevos datos electroquímicos de los sustratos indicados y conocimientos relacionados con la aplicación de electrodos modificados en la preparación de biosensores y en el desarrollo de técnicas alternativas para la determinación de los analitos mencionados precedentemente. Electrochemical reaction mechanisms of mycotoxins (toxic metabolites generated by fungi) citrinin (CIT), Patulin (PAT) and moniliformin (MON), natural antioxidants alpha, beta, gamma and delta tocopherols, flavonoids fisetin (FIS), morin (MOR), luteolin (LUT), rutin (RUT), butein (BUT), naringenin (NAR), miricetin (MIR) and steroid hormones estradiol (EDIOL), estrone (EONA) and estriole (ETRIOL) will be explored. On the other hand, electroanalytical techniques for the detection and quantification of these substrates in samples of natural matrices will be implemented. The design and characterization of enzymatic biosensors from peroxidases and/or from alkaline phosphatase for the determination of CIT and flavonoids, and also of inmunosensors for ochratoxin A (OTA) and PAT and hormones will be performed. For the anchor of enzymes and/or antibody, properties of electrodes modified by self assembled monolayers, carbon nanotubes and magnetic particles will be explored. Cyclic, square wave and adsorptive stripping voltammetries, electrochemical impedance spectroscopy, controlled potential electrolysis, uv-vis and IR, quartz crystal microbalance and high-resolution microcopies (SEM, TEM, AFM) will be used. The importance of this project is aimed at obtaining new electrochemical data for the indicated substrates and knowledge on the application of modified electrodes in preparation of biosensors and in the development of alternative techniques for the determination of the above-mentioned analytes.
Resumo:
The objective of the current study was to compare two rapid methods, the BBL Mycobacteria Growth Indicator Tube (MGIT TM) and Biotec FASTPlaque TB TM (FPTB) assays, with the conventional Löwenstein-Jensen (LJ) media assay to diagnose mycobacterial infections from paucibacillary clinical specimens. For evaluation of the clinical utility of the BBL MGIT TM and FPTB assays, respiratory tract specimens (n = 208), with scanty bacilli or clinically evident, smear negative cases and non-respiratory tract specimens (n = 119) were analyzed and the performance of each assay was compared with LJ media. MGIT and FPTB demonstrated a greater sensitivity (95.92% and 87.68%), specificity (94.59% and 98.78%), positive predictive value (94.91% and 99.16%) and negative predictive value (96.56% and 90.92%), respectively, compared to LJ culture for both respiratory tract and non-respiratory tract specimens. However, the FPTB assay was unable to detect nontuberculous mycobacteria and few Mycobacterium tuberculosis complex cases from paucibacillary clinical specimens. It is likely that the analytical sensitivity of FPTB is moderately low and may not be useful for the direct detection of tuberculosis in paucibacillary specimens. The current study concluded that MGIT was a dependable, highly efficient system for recovery of M. tuberculosis complexes and nontuberculous mycobacteria from both respiratory and non-respiratory tract specimens in combination with LJ media.
Resumo:
The European Prospective Investigation into Cancer and nutrition (EPIC) is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS) and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88%) performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies.
Resumo:
Advances in clinical virology for detecting respiratory viruses have been focused on nucleic acids amplification techniques, which have converted in the reference method for the diagnosis of acute respiratory infections of viral aetiology. Improvements of current commercial molecular assays to reduce hands-on-time rely on two strategies, a stepwise automation (semi-automation) and the complete automation of the whole procedure. Contributions to the former strategy have been the use of automated nucleic acids extractors, multiplex PCR, real-time PCR and/or DNA arrays for detection of amplicons. Commercial fully-automated molecular systems are now available for the detection of respiratory viruses. Some of them could convert in point-of-care methods substituting antigen tests for detection of respiratory syncytial virus and influenza A and B viruses. This article describes laboratory methods for detection of respiratory viruses. A cost-effective and rational diagnostic algorithm is proposed, considering technical aspects of the available assays, infrastructure possibilities of each laboratory and clinic-epidemiologic factors of the infection.
Resumo:
Nucleic acid amplification techniques are commonly used currently to diagnose viral diseases and manage patients with this kind of illnesses. These techniques have had a rapid but unconventional route of development during the last 30 years, with the discovery and introduction of several assays in clinical diagnosis. The increase in the number of commercially available methods has facilitated the use of this technology in the majority of laboratories worldwide. This technology has reduced the use of some other techniques such as viral culture based methods and serological assays in the clinical virology laboratory. Moreover, nucleic acid amplification techniques are now the methods of reference and also the most useful assays for the diagnosis in several diseases. The introduction of these techniques and their automation provides new opportunities for the clinical laboratory to affect patient care. The main objectives in performing nucleic acid tests in this field are to provide timely results useful for high-quality patient care at a reasonable cost, because rapid results are associated with improvements in patients care. The use of amplification techniques such as polymerase chain reaction, real-time polymerase chain reaction or nucleic acid sequence-based amplification for virus detection, genotyping and quantification have some advantages like high sensitivity and reproducibility, as well as a broad dynamic range. This review is an up-to-date of the main nucleic acid techniques and their clinical applications, and special challenges and opportunities that these techniques currently provide for the clinical virology laboratory.
Resumo:
BACKGROUND Drugs for inhalation are the cornerstone of therapy in obstructive lung disease. We have observed that up to 75 % of patients do not perform a correct inhalation technique. The inability of patients to correctly use their inhaler device may be a direct consequence of insufficient or poor inhaler technique instruction. The objective of this study is to test the efficacy of two educational interventions to improve the inhalation techniques in patients with Chronic Obstructive Pulmonary Disease (COPD). METHODS This study uses both a multicenter patients´ preference trial and a comprehensive cohort design with 495 COPD-diagnosed patients selected by a non-probabilistic method of sampling from seven Primary Care Centers. The participants will be divided into two groups and five arms. The two groups are: 1) the patients´ preference group with two arms and 2) the randomized group with three arms. In the preference group, the two arms correspond to the two educational interventions (Intervention A and Intervention B) designed for this study. In the randomized group the three arms comprise: intervention A, intervention B and a control arm. Intervention A is written information (a leaflet describing the correct inhalation techniques). Intervention B is written information about inhalation techniques plus training by an instructor. Every patient in each group will be visited six times during the year of the study at health care center. DISCUSSION Our hypothesis is that the application of two educational interventions in patients with COPD who are treated with inhaled therapy will increase the number of patients who perform a correct inhalation technique by at least 25 %. We will evaluate the effectiveness of these interventions on patient inhalation technique improvement, considering that it will be adequate and feasible within the context of clinical practice.
Resumo:
Often practical performance of analytical redundancy for fault detection and diagnosis is decreased by uncertainties prevailing not only in the system model, but also in the measurements. In this paper, the problem of fault detection is stated as a constraint satisfaction problem over continuous domains with a big number of variables and constraints. This problem can be solved using modal interval analysis and consistency techniques. Consistency techniques are then shown to be particularly efficient to check the consistency of the analytical redundancy relations (ARRs), dealing with uncertain measurements and parameters. Through the work presented in this paper, it can be observed that consistency techniques can be used to increase the performance of a robust fault detection tool, which is based on interval arithmetic. The proposed method is illustrated using a nonlinear dynamic model of a hydraulic system