965 resultados para MASS SPECTROMETRY, GAS PHASE ACIDITY, GAS PHASE BASICITY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Both El MS and FAB MS behavior of two groups of compounds, aryltin and ferrocene compounds, have been studied. For the aryltin compounds, the effect of substituent group position, substituent group type and ligand type on the El spectra have been explored in the El MS studies. The fragmentation mechanism has been investigated under El with linked scans, such as fragment ion scans(BJE), parent ion scans(B2JE) and constant neutral radical loss scans(B2(1-E)JE2). In the FAB MS studies, matrix optimization experiments have been carried out. The positive ion FAB MS studies focused on the effect of substituent group position, substituent group type and ligand type on the spectra. The fragmentation mechanisms of all the samples under positive ion FAB have been studied by means of the linked scans. The CA positive ion FAB fragmentation studies were also carried out for a typical sample. Negative ion FAB experiments of all the compounds have been done. And finally, the comparison of the El MS and FAB MS has been made. For ferrocenes, the studies concentrated on the fragmentation mechanism of each compound under El with linked scan techniques in the first field-free region and the applicability of positive/negative ion FAB MS to this group of compounds. The fragmentation mechanisms under positive ion FAB of those ferrocenes which can give positive ion FAB MS spectra were studied with the linked scan techniques. The CA +ve F AB fragmentation studies were carried out for a typical sample. Comparison of the E1 MS and FAB MS has been made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A number of metal complexes containing the ligand 5,5,7,12,12,14-hexamethyl-l,4,8,11-tetra-azatetradecane were synthesized and analyzed using electron impact (EI) and fast atom bombardment (FAB). The FAB mass spectra were obtained in positive and negative ion mode. FAB in the positive ion mode proved to be the most successful technique for the identification of these compounds. In the majority of cases the spectra obtained using positive ion FAB were structurally informative, although not all showed molecular (M+) or quasimolecular ([M+H]+) ions. The fragmentations observed were characteristic of the ligands, and were interpreted based on the chemistry of these compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to investigate the use of Fast Atom Bombardment Mass Spectrometry (FAB-MS) as a tool for structural characterization, two groups of complexes are analyzed. The first group is a set of ruthenium(II) coordination complexes containing bidentate polypyridyl ligands. The positive and negative ion FAB-MS spectra are found to be sufficient to allow for an almost complete characterization of the central metal atom, the ligands and the counter anions contained in the intact complex. An unusual observation of mUltiply charged ions in the positive ion FAB-MS spectra (i.e. [RUL 3 ]2+) is explained to be as a result of the oxidative quenching of the excited state of the doubly charged ion by the matrix, 3-nitrobenzyl alcohol. An analysis of a mixture shows that the technique is a good one for identifying components therein. A group of triptycene and related complexes containing Group V elements is also analyzed by FAB-MS and the results. in terms of relative abundances of fragment ions, are found to be consistent with known metal-carbon bond strengths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis can be broken down into two sections. Section one is a study . of the ionization mechanisms and the ion source optimization for Fast Atom Bombardment (FAB) ionization. For this study, several specially designed probe tips were created and tested under various experimental conditions. The aIm of this section is to understand the operating characteristics of a FAB IOn source better. The second section involves the study of several Vitamin B6 Schiff Base complexes using both positive and negative ion FAB MS. This section is an exploration of the usefulness of FAB MS as a structure probe for the metalcoordination complexes of Vitamin B6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le long bio-polymère d'ADN est condensé à l’intérieur du noyau des cellules eukaryotes à l'aide de petites protéines appelées histones. En plus de leurs fonctions condensatrices,ces histones sont également la cible de nombreuses modifications post-traductionnelles(MPT), particulièrement au niveau de leur section N-terminale. Ces modifications réversibles font partie d’un code d’histones épi-génétique transmissible qui orchestre et module dynamiquement certains événements impliquant la chromatine, tels l’activation et la désactivation de gènes ainsi que la duplication et la réparation d’ADN. Ces modifications sont impliquées subséquemment dans la signalisation et la progression de cancers, tels que la leucémie. En conséquence, l'élucidation des modifications d’histones est importante pour comprendre leurs fonctions biologiques. Une méthodologie analytique a été mise au point en laboratoire pour isoler, détecter, et quantifier les MPT d’histones en utilisant une approche rapide à deux volets à l’aide d’outils bioinformatiques spécialisés. La méthodologie développée en laboratoire a été validée en utilisant des histones de souche sauvage ainsi que deux types d’histones mutants déficients en enzymes acétyltransferase. Des trois sources d’histones utilisées, la seule MPT qui a démontré un changement significatif est l’acétylation de l’histone H3 à lysine 56 (H3K56ac). L’expression et la stoechiométrie de cette MPT, issue de cellules de souche sauvage et de cellules mutantes, ont été déterminées avec précision et comparées. Les fonctions de balayage polyvalentes d'un instrument à trappe ionique quadrupôle linéaire hybride ont été utilisées pour améliorer la détection de protéines intactes. Le mode de balayage « enhanced multiply charged » (EMC) a été modifié pour contenir et détecter les ions de protéines intactes situées dans la trappe ionique linéaire. Ce mode de balayage nommé « targeted EMC » (tEMC) a permis de quadrupler le niveau de sensibilité (signal/interférence), et quintupler la résolution du mode de balayage conventionnel. De plus, la capacité de séparation des charges du tEMC a réduit de façon significative les effets de « space charge » dans la trappe ionique linéaire. La résolution supérieure du mode tEMC a permis de différencier plusieurs isoformes modifiées, particulièrement pour l’histone H3. L’analyse des peptides d’histones trypsiques à l’aide du mode de balayage « MRM » a permis le séquençage et la quantification de MPT avec un haut degré de précision. La seule MPT qui était sous-exprimée entre l’histone de souche sauvage et le mutant DOT1L fut la méthylation de l’histone H3 lysine 79(H3K79me1). Les effets de deux inhibiteurs d’enzymes HDAC (HDACi) sur l’expression de MPT d’histone ont été évalués en utilisant la méthodologie analytique mentionnée. Les histones extraites de cellules normales et cancéreuses ont été exposées à du Vorinostat(SAHA) ou du Entinostat (MS-275) pour une période de 24 à 72 heures. Deux histones furent principalement affectées, soit H3 et H4. Étonnamment, les mêmes effets n'ont pas été détectés lorsque les cellules normales ont été traitées avec le HDACi pour une période de 48 à 72 heures. Une méthode absolue de quantification avec une courbe d’étalonnage a été développée pour le peptide H3K56ac. Contrairement à certaines publications, nos résultats démontrent que cette MPT est présente dans les cellules mammifères avec une stoechiométrie très basse (< 0,1%) et n'est pas surexprimée de façon significative après le traitement au HDACi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les fichiers qui accompagnent mon document sont des tableaux supplémentaires réalisés avec Excel (Microsoft Office), dans la version papier du mémoire ces fichiers sont sur un CD-ROM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’entérotoxine B staphylococcique (SEB) est une toxine entérique hautement résistante à la chaleur et est responsable de plus de 50 % des cas d’intoxication d’origine alimentaire par une entérotoxine. L’objectif principal de ce projet de maîtrise est de développer et valider une méthode basée sur des nouvelles stratégies analytiques permettant la détection et la quantification de SEB dans les matrices alimentaires. Une carte de peptides tryptiques a été produite et 3 peptides tryptiques spécifiques ont été sélectionnés pour servir de peptides témoins à partir des 9 fragments protéolytiques identifiés (couverture de 35 % de la séquence). L’anhydride acétique et la forme deutérée furent utilisés afin de synthétiser des peptides standards marqués avec un isotope léger et lourd. La combinaison de mélanges des deux isotopes à des concentrations molaires différentes fut utilisée afin d’établir la linéarité et les résultats ont démontré que les mesures faites par dilution isotopique combinée au CL-SM/SM respectaient les critères généralement reconnus d’épreuves biologiques avec des valeurs de pente près de 1, des valeurs de R2 supérieure à 0,98 et des coefficients de variation (CV%) inférieurs à 8 %. La précision et l’exactitude de la méthode ont été évaluées à l’aide d’échantillons d’homogénat de viande de poulet dans lesquels SEB a été introduite. SEB a été enrichie à 0,2, 1 et 2 pmol/g. Les résultats analytiques révèlent que la méthode procure une plage d’exactitude de 84,9 à 91,1 %. Dans l’ensemble, les résultats présentés dans ce mémoire démontrent que les méthodes protéomiques peuvent être utilisées efficacement pour détecter et quantifier SEB dans les matrices alimentaires. Mots clés : spectrométrie de masse; marquage isotopique; protéomique quantitative; entérotoxines

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. It provides substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected Reaction Monitoring allows targeted assay development but data sets generated contain very limited information. Data mining and analysis of non-targeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study was to test method precision and accuracy, statistically compare bupivacaine drug concentration in real study samples and verify if high resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy was ranging from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods reveal a coefficient of determination (R2) of 0.9996 and a slope of 1.02 demonstrating a very strong correlation between both methods. Individual sample comparison showed differences from -4.5% to 1.6% well within the accepted analytical error. Moreover, post acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M-56) and m/z 305.2224 ± 5 ppm (M+16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post acquisition analysis allowed us to produce semiquantitative evaluations of the concentration-time profiles for bupicavaine metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tachykinin and opioid peptides play a central role in pain transmission, modulation and inhibition. The treatment of pain is very important in medicine and many studies using NK1 receptor antagonists failed to show significant analgesic effects in humans. Recent investigations suggest that both pronociceptive tachykinins and the analgesic opioid systems are important for normal pain sensation. The analysis of opioid peptides in Tac1-/- spinal cord tissues offers a great opportunity to verify the influence of the tachykinin system on specific opioid peptides. The objectives of this study were to develop a HPLC–MS/MRM assay to quantify targeted peptides in spinal cord tissues. Secondly, we wanted to verify if the Tac1-/- mouse endogenous opioid system is hampered and therefore affect significantly the pain modulatory pathways. Targeted neuropeptides were analyzed by high performance liquid chromatography linear ion trap mass spectrometry. Our results reveal that EM-2, Leu-Enk and Dyn A were down-regulated in Tac1-/- spinal cord tissues. Interestingly, Dyn A was almost 3 fold down-regulated (p < 0.0001). No significant concentration differences were observed in mouse Tac1-/- spinal cords for Met-Enk and CGRP. The analysis of Tac1-/- mouse spinal cords revealed noteworthy decreases of EM-2, Leu-Enk and Dyn A concentrations which strongly suggest a significant impact on the endogenous pain-relieving mechanisms. These observations may have insightful impact on future analgesic drug developments and therapeutic strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, we observed a significant increase of food fraud ranging from false label claims to the use of additives and fillers to increase profitability. Recently in 2013, horse and pig DNA were detected in beef products sold from several retailers. Mass spectrometry has become the workhorse in protein research and the detection of marker proteins could serve for both animal species and tissue authentication. Meat species authenticity will be performed using a well defined proteogenomic annotation, carefully chosen surrogate tryptic peptides and analysis using a hybrid quadrupole-Orbitrap mass spectrometer. Selected mammalian meat samples were homogenized, proteins were extracted and digested with trypsin. The samples were analyzed using a high-resolution mass spectrometer. The chromatography was achieved using a 30 minutes linear gradient along with a BioBasic C8 100 × 1 mm column at a flow rate of 75 µL/min. The mass spectrometer was operated in full-scan high resolution and accurate mass. MS/MS spectra were collected for selected proteotypic peptides. Muscular proteins were methodically analyzed in silico in order to generate tryptic peptide mass lists and theoretical MS/MS spectra. Following a comprehensive bottom-up proteomic analysis, we were able to detect and identify a proteotypic myoglobin tryptic peptide [120-134] for each species with observed m/z below 1.3 ppm compared to theoretical values. Moreover, proteotypic peptides from myosin-1, myosin-2 and -hemoglobin were also identified. This targeted method allowed a comprehensive meat speciation down to 1% (w/w) of undesired product.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets <10 nL in size. By using a sample droplet <10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry - one of the most commonly used analytical tools in proteomics - for high-throughput analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.