517 resultados para LID RETRACTION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective Epidermoid cysts of the cerebellopontine angle (CPA) can be a surgical challenge for the pediatric neurosurgeon. Ideally, total removal must be achieved; however, occasional adhesions of these tumors to vital neurovascular structures and extension far beyond the midline may preclude their total removal. The aims of this article are to present an alternative surgical approach to these lesions and to provide the rationale for this technique. Material and methods A 16-year-old boy was admitted to our pediatric neurosurgery department with a 1-year history of nonspecific headaches. His neurological examination showed right-sided dysmetria and gait ataxia. Magnetic resonance scans showed a space-occupying lesion on the right CPA with low intensity on T-1-weighted images and high intensity on T-2-weighted images. Results Craniotomy for tumor excision via pre- and subtemporal transtentorial approach was performed disclosing a 3.5 x 3 x 2.8-cm(3) well-encapsulated tumor, which was confirmed to be an epidermoid cyst. The postoperative course was uneventful. Conclusions A combined pre- and subtemporal approach utilizes a wide opening of the tentorium and the option of supratentorial retraction of the cerebellum to provide an excellent angle of approach to CPA lesions involving the anterolateral aspect of the brain stem in children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dynamics, over the last 7500 years, of a mangrove at Marajo Island in northern Brazil were studied by pollen and sedimentary facies analyses using sediment cores. This island, located at the mouth of the Amazon River. is influenced by riverine inflow combined with tidal fluctuations of the equatorial Atlantic Ocean. Herbaceous vegetation intermingled with rainforest dominates the central area of the island, while varzea is the main vegetation type along the littoral. In particular, the modem northeastern coastal zone is covered by a mosaic of dense rainforest, herbaceous vegetation, mangroves, varzea, and restinga. The integration of pollen data and fades descriptions indicates a tidal mud flat colonized by mangroves in the interior of Marajo Island between similar to 7500 cal yr BP and similar to 3200 cal yr BP. During the late Holocene, mangroves retracted to a small area (100-700 m in width) along the northeastern coastal plain. Mangrove expansion during the early and mid Holocene was likely caused by the post-glacial sea-level rise which, combined with tectonic subsidence, led to a rise in tidal water salinity. Salinity must have further increased due to low river discharge resulting from increased aridity during the early and mid Holocene. The shrinking of the area covered by mangrove vegetation during the late Holocene was likely caused by the increase in river discharge during the late Holocene, which has maintained relatively low tidal water salinity in Marajo Island. Tidal water salinity is relatively higher in the northeastern part of the island than in others, due to the southeast-northwest trending current along the littoral. The mixing of marine and riverine freshwater inflows has provided a refuge for mangroves in this area. The increase in flow energy during the last century is related to landward sand migration, which explains the current retraction of mangroves. These changes may indicate an increased exposure to tidal influence driven by the relative sea-level rise, either associated with global fluctuations or tectonic subsidence, and/or by an increase in river water discharge. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the efficacy of radiotherapy (RT) with total dose of 20 Gy (RT 20 Gy) in the treatment of Graves' ophthalmopathy. METHODS: A systematic review and meta-analysis of randomized controlled trials was performed comparing RT 20 Gy with or without glucocorticoid to clinical treatments for Graves' ophthalmopathy. The MEDLINE, EMBASE, Cochrane Library databases and recent relevant journals were searched. Relevant reports were reviewed by two reviewers. Response to radiotherapy was defined as clinical success according to each trial. We also evaluated the quality of life and whether RT to produce fewer side effects than other treatments. RESULTS: A total of 8 randomized controlled trials (439 patients) were identified. In the subgroup analysis, the overall response to treatment rates was better for: RT 20 Gy plus glucocorticoid vs glucocorticoids alone, OR=17.5 (CI95% 1.85-250, p=0.04), RT 20 Gy vs sham RT, OR= 3.15 (CI95%1.59-6.23, p=0.003) and RT 20Gy plus intravenous glucocorticoid vs RT 20Gy plus oral glucocorticoid, OR=4.15(CI95% 1.34-12.87, p=0.01). There were no differences between RT 20 Gy versus other fractionations and RT 20 Gy versus glucocorticoid alone. RT 20 Gy with or without glucocorticoids showed an improvement in diplopia grade, visual acuity, optic neuropathy, lid width, proptosis and ocular motility. No difference was seen for costs, intraocular pressure and quality of life. CONCLUSION: Our data have shown that RT 20 Gy should be offered as a valid therapeutic option to patients with moderate to severe ophthalmopathy. The effectiveness of orbital radiotherapy can be increased by the synergistic interaction with glucocorticoids. Moreover, RT 20 Gy is useful to improve a lot of ocular symptoms, excluding intraocular pressure, without any difference in quality of life and costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most amniotes vertebrates have an intromittent organ to deliver semen. The reptile Sphenodon and most birds lost the ancestral penis and developed a cloaca-cloaca mating. Known as hemipenises, the copulatory organ of Squamata shows unique features between the amniotes intromittent organ. They are the only paired intromittent organs across amniotes and are fully inverted and encapsulated in the tail when not in use. The histology and ultrastructure of the hemipenes of Crotalus durissus rattlesnake is described as the evolutionary implications of the main features discussed. The organization of hemipenis of Crotalus durissus terrificus in two concentric corpora cavernosa is similar to other Squamata but differ markedly from the organization of the penis found in crocodilians, testudinata, birds and mammals. Based on the available data, the penis of the ancestral amniotes was made of connective tissue and the incorporation of smooth muscle in the framework of the sinusoids occurred independently in mammals and Crotalus durissus. The propulsor action of the muscle retractor penis basalis was confirmed and therefore the named should be changed to musculus hemipenis propulsor.The retractor penis magnus found in Squamata has no homology to the retractor penis of mammals, although both are responsible for the retraction of the copulatory organ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Group B Streptococcus (GBS) three structurally distinct types of pili have been discovered as potential virulence factors and vaccine candidates. The pilus-forming proteins are assembled into high-molecular weight polymers via a transpeptidation mechanism mediated by specific class C sortases. Using a multidisciplinary approach including bioinformatics, structural and biochemical studies and in vivo mutagenesis we performed a broad characterization of GBS sortase C. The high resolution X-ray structure of the enzymes revealed that the active site, located into the β-barrel core of the enzyme, is made of the catalytic triad His157-Cys219-Arg228 and covered by a loop, known as the “lid”. We show that the catalytic triad and the predicted N- and C-terminal trans-membrane regions are required for the enzyme activity. Interestingly, by in vivo complementation mutagenesis studies we found that the deletion of the entire lid loop or mutations in specific lid key residues had no effect on catalytic activity of the enzyme. In addition, kinetic characterizations of recombinant enzymes indicate that the lid mutants can still recognize and cleave the substrate-mimicking peptide at least as well as the wild type protein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis, we investigated the evaporation of sessile microdroplets on different solid substrates. Three major aspects were studied: the influence of surface hydrophilicity and heterogeneity on the evaporation dynamics for an insoluble solid substrate, the influence of external process parameters and intrinsic material properties on microstructuring of soluble polymer substrates and the influence of an increased area to volume ratio in a microfluidic capillary, when evaporation is hindered. In the first part, the evaporation dynamics of pure sessile water drops on smooth self-assembled monolayers (SAMs) of thiols or disulfides on gold on mica was studied. With increasing surface hydrophilicity the drop stayed pinned longer. Thus, the total evaporation time of a given initial drop volume was shorter, since the drop surface, through which the evaporation occurs, stays longer large. Usually, for a single drop the volume decreased linearly with t1.5, t being the evaporation time, for a diffusion-controlled evaporation process. However, when we measured the total evaporation time, ttot, for multiple droplets with different initial volumes, V0, we found a scaling of the form V0 = attotb. The more hydrophilic the substrate was, the more showed the scaling exponent a tendency to an increased value up to 1.6. This can be attributed to an increasing evaporation rate through a thin water layer in the vicinity of the drop. Under the assumption of a constant temperature at the substrate surface a cooling of the droplet and thus a decreased evaporation rate could be excluded as a reason for the different scaling exponent by simulations performed by F. Schönfeld at the IMM, Mainz. In contrast, for a hairy surface, made of dialkyldisulfide SAMs with different chain lengths and a 1:1 mixture of hydrophilic and hydrophobic end groups (hydroxy versus methyl group), the scaling exponent was found to be ~ 1.4. It increased to ~ 1.5 with increasing hydrophilicity. A reason for this observation can only be speculated: in the case of longer hydrophobic alkyl chains the formation of an air layer between substrate and surface might be favorable. Thus, the heat transport to the substrate might be reduced, leading to a stronger cooling and thus decreased evaporation rate. In the second part, the microstructuring of polystyrene surfaces by drops of toluene, a good solvent, was investigated. For this a novel deposition technique was developed, with which the drop can be deposited with a syringe. The polymer substrate is lying on a motorized table, which picks up the pendant drop by an upward motion until a liquid bridge is formed. A consecutive downward motion of the table after a variable delay, i.e. the contact time between drop and polymer, leads to the deposition of the droplet, which can evaporate. The resulting microstructure is investigated in dependence of the processes parameters, i.e. the approach and the retraction speed of the substrate and the delay between them, and in dependence of the intrinsic material properties, i.e. the molar mass and the type of the polymer/solvent system. The principal equivalence with the microstructuring by the ink-jet technique was demonstrated. For a high approach and retraction speed of 9 mm/s and no delay between them, a concave microtopology was observed. In agreement with the literature, this can be explained by a flow of solvent and the dissolved polymer to the rim of the pinned droplet, where polymer is accumulated. This effect is analogue to the well-known formation of ring-like stains after the evaporation of coffee drops (coffee-stain effect). With decreasing retraction speed down to 10 µm/s the resulting surface topology changes from concave to convex. This can be explained with the increasing dissolution of polymer into the solvent drop prior to the evaporation. If the polymer concentration is high enough, gelation occurs instead of a flow to the rim and the shape of the convex droplet is received. With increasing delay time from below 0 ms to 1s the depth of the concave microwells decreases from 4.6 µm to 3.2 µm. However, a convex surface topology could not be obtained, since for longer delay times the polymer sticks to the tip of the syringe. Thus, by changing the delay time a fine-tuning of the concave structure is accomplished, while by changing the retraction speed a principal change of the microtopolgy can be achieved. We attribute this to an additional flow inside the liquid bridge, which enhanced polymer dissolution. Even if the pendant drop is evaporating about 30 µm above the polymer surface without any contact (non-contact mode), concave structures were observed. Rim heights as high as 33 µm could be generated for exposure times of 20 min. The concave structure exclusively lay above the flat polymer surface outside the structure even after drying. This shows that toluene is taken up permanently. The increasing rim height, rh, with increasing exposure time to the solvent vapor obeys a diffusion law of rh = rh0  tn, with n in the range of 0.46 ~ 0.65. This hints at a non-Fickian swelling process. A detailed analysis showed that the rim height of the concave structure is modulated, unlike for the drop deposition. This is due to the local stress relaxation, which was initiated by the increasing toluene concentration in the extruded polymer surface. By altering the intrinsic material parameters i.e. the polymer molar mass and the polymer/solvent combination, several types of microstructures could be formed. With increasing molar mass from 20.9 kDa to 1.44 MDa the resulting microstructure changed from convex, to a structure with a dimple in the center, to concave, to finally an irregular structure. This observation can be explained if one assumes that the microstructuring is dominated by two opposing effects, a decreasing solubility with increasing polymer molar mass, but an increasing surface tension gradient leading to instabilities of Marangoni-type. Thus, a polymer with a low molar mass close or below the entanglement limit is subject to a high dissolution rate, which leads to fast gelation compared to the evaporation rate. This way a coffee-rim like effect is eliminated early and a convex structure results. For high molar masses the low dissolution rate and the low polymer diffusion might lead to increased surface tension gradients and a typical local pile-up of polymer is found. For intermediate polymer masses around 200 kDa, the dissolution and evaporation rate are comparable and the typical concave microtopology is found. This interpretation was supported by a quantitative estimation of the diffusion coefficient and the evaporation rate. For a different polymer/solvent system, polyethylmethacrylate (PEMA)/ethylacetate (EA), exclusively concave structures were found. Following the statements above this can be interpreted with a lower dissolution rate. At low molar masses the concentration of PEMA in EA most likely never reaches the gelation point. Thus, a concave instead of a convex structure occurs. At the end of this section, the optically properties of such microstructures for a potential application as microlenses are studied with laser scanning confocal microscopy. In the third part, the droplet was confined into a glass microcapillary to avoid evaporation. Since here, due to an increased area to volume ratio, the surface properties of the liquid and the solid walls became important, the influence of the surface hydrophilicity of the wall on the interfacial tension between two immiscible liquid slugs was investigated. For this a novel method for measuring the interfacial tension between the two liquids within the capillary was developed. This technique was demonstrated by measuring the interfacial tensions between slugs of pure water and standard solvents. For toluene, n-hexane and chloroform 36.2, 50.9 and 34.2 mN/m were measured at 20°C, which is in a good agreement with data from the literature. For a slug of hexane in contact with a slug of pure water containing ethanol in a concentration range between 0 and 70 (v/v %), a difference of up to 6 mN/m was found, when compared to commercial ring tensiometry. This discrepancy is still under debate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In dieser Doktorarbeit werden die Eigenschaften von thermoresponsiven Bürstenpolymeren untersucht. Hierbei konnten erstmalig thermische Konformationsübergänge von zylindrischen Bürstenmolekülen auf Oberflächen beobachtet werden. Der Einfluss der Oberfläche auf die Umkehrbarkeit und die Kinetik der Übergänge wurde untersucht. Die dabei erhaltenen Erkenntnisse konnten verwendet werden, um das Verhalten der Polymere auf anderen Oberflächen vorherzusagen. Im zweiten Projekt wurde gezeigt, dass Einzelmolekül-Kraftspektroskopie eine gute Methode für die Untersuchung der mechanischen Eigenschaften von Bürstenpolymeren in guten Lösungsmitteln ist. Mit kleinen Substanzmengen kann die Persistenzlänge der Polymere bestimmt werden. Es ist möglich zu zeigen, dass die Persistenzlänge der Polymerbürsten von ihrer Seitenkettenlänge abhängt. Überraschenderweise funktioniert das Experiment nicht, wenn man die Bürsten aus einem Polymerfilm zieht anstatt ein Einzelmolekülexperiment durchzuführen. In diesem Fall zeigen die Kraft-Abstands-Kurven zu lange Kontur- und Persistenzlängen. Diese Beobachtung ist für lineare Polymere nicht gültig. Im dritten Teil der Doktorarbeit werden Kraft-Abstands-Experimente an einzelnen kollabierten Polymeren untersucht. In schlechten Lösungsmitteln zeigen die Bürsten ein moleküllängenabhängiges Kraft-Plateau, welches theoretisch vorausgesagt wurde und einen Phasenübergang von einem kollabierten zu einem entspannten Zustand der Polymerkette anzeigt. In Fly-Fishing-Experimenten kann man eine Hysterese zwischen den beiden Messkurven beobachten, welche bei mehrfachem Ziehen kleiner wird. Alle Experimente in schlechten Lösungsmitteln wurden mit linearen Polymeren reproduziert, um den Einfluss der Molekülarchitektur von den generellen Eigenschaften von Polymeren in schlechten Lösungsmitteln unterscheiden zu können. Zum Abschluss wird die Abhängigkeit der Polymerentfaltung von der Laderate des Experiments gemessen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Form und Gestalt kraniofazialer Strukturen sind primär beeinflusst durch die inhärente Integration der unterschiedlichsten Funktionssysteme und externer selektiver Einflüsse. Die Variabilität der Schädel-Morphe ist ein Indikator für solche Einflussfaktoren und damit ein idealer Gegenstand für vergleichende Analysen morphogenetischer Formbildung. Zur Ermittlung morphologisch-adaptiver Trends und Muster wurden sowohl Hypothesen zur morphologischen Differenziertheit als auch zu Korrelationen zwischen modularen Schädelkompartimenten (fazial, neurokranial, basikranial) untersucht. Zusätzlich wurden aus Schichtröntgenaufnahmen (CT) virtuelle Modelle rekonstruiert, welche die Interpretation der statistischen Befunde unterstützen sollten. Zur Berechnung der Gestaltunterschiede wurden mittels eines mechanischen Gelenkarm-Messgerätes (MicroScribe-G2) max. 85 ektokraniale Messpunkte (Landmarks) bzw. dreidimensionale Koordinaten an ca. 520 Schädeln von fünf rezenten Gattungen der Überfamilie Hominoidea (Hylobates, Pongo, Gorilla, Pan und Homo) akquiriert. Aus dem Datensatz wurden geometrische Störfaktoren (Größe, Translation, Rotation) mathematisch eliminiert und die verbleibenden Residuale bzw. ‚Gestalt-Variablen‘ diversen multivariat-statistischen Verfahren unterzogen (Faktoren, Cluster-, Regressions- und Korrelationsanalysen sowie statistische Tests). Die angewandten Methoden erhalten die geometrische Information der Untersuchungsobjekte über alle Analyseschritte hinweg und werden unter der Bezeichnung „Geometric Morphometrics (GMM)“ als aktueller Ansatz der Morphometrie zusammengefasst. Für die unterschiedlichen Fragestellungen wurden spezifische Datensätze generiert. Es konnten diverse morphologische Trends und adaptive Muster mit Hilfe der Synthese statistischer Methoden und computer-basierter Rekonstruktionen aus den generierten Datensätzen ermittelt werden. Außerdem war es möglich, präzise zu rekonstruieren, welche kranialen Strukturen innerhalb der Stichprobe miteinander wechselwirken, einzigartige Variabilitäten repräsentieren oder eher homogen gestaltet sind. Die vorliegenden Befunde lassen erkennen, dass Fazial- und Neurokranium am stärksten miteinander korrelieren, während das Basikranium geringe Abhängigkeiten in Bezug auf Gesichts- oder Hirnschädelveränderungen zeigte. Das Basikranium erweist sich zudem bei den nicht-menschlichen Hominoidea und über alle Analysen hinweg als konservative und evolutiv-persistente Struktur mit dem geringsten Veränderungs-Potential. Juvenile Individuen zeigen eine hohe Affinität zueinander und zu Formen mit einem kleinem Gesichts- und großem Hirnschädel. Während das Kranium des rezenten Menschen primär von Enkephalisation und fazialer Retraktion (Orthognathisierung) dominiert ist und somit eine einzigartige Gestalt aufweist, zeigt sich der Kauapparat als maßgeblich formbildendes Kompartiment bei den nicht-menschlichen Formen. Die Verbindung von GMM mit den interaktiven Möglichkeiten computergenerierter Modelle erwies sich als valides Werkzeug zur Erfassung der aufgeworfenen Fragestellungen. Die Interpretation der Befunde ist durch massive Interkorrelationen der untersuchten Strukturen und der statistisch-mathematischen Prozeduren als hoch komplex zu kennzeichnen. Die Studie präsentiert einen innovativen Ansatz der modernen Morphometrie, welcher für zukünftige Untersuchungen im Bereich der kraniofazialen Gestaltanalyse ausgebaut werden könnte. Dabei verspricht die Verknüpfung mit ‚klassischen’ und modernen Zugängen (z. B. Molekularbiologie) gesteigerte Erkenntnismöglichkeiten für künftige morphometrische Fragestellungen.