995 resultados para Hearing protection devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general transcription factor TFIIB, encoded by SUA7 in Saccharomyces cerevisiae, is required for transcription activation but apparently of a specific subset of genes, for example, linked with mitochondrial activity and hence with oxidative environments. Therefore, studying SUA7/TFIIB as a potential target of oxidative stress is fundamental. We found that controlled SUA7 expression under oxidative conditions occurs at transcriptional and mRNA stability levels. Both regulatory events are associated with the transcription activator Yap1 in distinct ways: Yap1 affects SUA7 transcription up regulation in exponentially growing cells facing oxidative signals; the absence of this activator per se contributes to increase SUA7 mRNA stability. However, unlike SUA7 mRNA, TFIIB abundance is not altered on oxidative signals. The biological impact of this preferential regulation of SUA7 mRNA pool is revealed by the partial suppression of cellular oxidative sensitivity by SUA7 overexpression, and supported by the insights on the existence of a novel RNA-binding factor, acting as an oxidative sensor, which regulates mRNA stability. Taken together the results point out a primarily cellular commitment to guarantee SUA7 mRNA levels under oxidative environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the validity of three single questions used to assess self-reported hearing loss as compared to pure-tone audiometry in an adult population. METHODS: A validity study was performed with a random sub-sample of 188 subjects aged 30 to 65 years, drawn from the fourth wave of a population-based cohort study carried out in Salvador, Northeastern Brazil. Data were collected in household visits using questionnaires. Three questions were used to separately assess self-reported hearing loss: Q1, "Do you feel you have a hearing loss?"; Q2, "In general, would you say your hearing is 'excellent,' 'very good,' 'good,' 'fair,' 'poor'?"; Q3, "Currently, do you think you can hear 'the same as before', 'less than before only in the right ear', 'less than before only in the left ear', 'less than before in both ears'?". Measures of accuracy were estimated through seven measures including Youden index. Responses to each question were compared to the results of pure-tone audiometry to estimate accuracy measures. RESULTS: The estimated sensitivity and specificity were 79.6%, 77.4% for Q1; 66.9%, 85.1% for Q2; and 81.5%, 76.4% for Q3, respectively. The Youden index ranged from 51.9% (Q2) to 57.0% (Q1) and 57.9% (Q3). CONCLUSIONS: Each of all three questions provides responses accurate enough to support their use to assess self-reported hearing loss in epidemiological studies with adult populations when pure-tone audiometry is not feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Hearing loss h sone raised impact in the development and academic progress of a child. In several developed countries, early detection is part of the national health plan through universal neonatal hearing screening (UNHS) and also with school hearing screening programs (SHSP), but only a few have published national data and revised protocols. Currently in Portugal, the UNHS is implemented in the main district hospitals but not the SHPS, as well we still do not make use of concrete data nor publication of studies on the national reality. Objectives: The incidence of the hearing loss and of otological problems was studied in school communities in the north of the country with 2550 participants between 3 and 17 years old. Methods: Statistical data collected within the schools with a standard auditory hearing screening protocol. All participants were evaluated with the same protocol, an audiological anamnesis, otoscopy and audiometric exam screening (500, 1000, 2000 and 4000 Hz) were fulfilled. Results: Different otological problems were identified and the audiometric screening exam counted auditory thresholds that outpointed uni and bilateral hearing loss in about 5.7% of the cases. Conclusions: The study has demonstrated that auditory school screening should take place as early as possible and be part of the primary health care to identify and direct children to appropriate rehabilitation, education and attendance. Thus, reducing high costs with late treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde- Ramo de especialização: Terapia com Radiações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Informática e Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os acidentes envolvendo veículos de duas rodas, são um dos maiores problemas da segurança rodoviária atual, no âmbito Europeu. Um dos tipos de acidentes que pode causar danos mais graves aos ocupantes desses veículos é o embate com guardas de segurança. Em consequência disso, neste trabalho foram desenvolvidas opiniões, abonatórias ou não, ao uso de dispositivos de proteção para motociclistas acoplados nas guardas de segurança. Estas opiniões vão partir de dados estatísticos, de estudos e exemplos concretos de vários autores e publicações relacionados com esta temática, sendo que o tipo de dispositivo de proteção para motociclistas que vai estar mais em foco e sendo ele o mais habitual nas estradas portuguesas será a saia metálica. Estes dispositivos de segurança para motociclistas ainda não são de uso obrigatório nas guardas de segurança na maioria dos países do continente Europeu, segundo a norma europeia EN 1317, apesar deste tipo de proteção já estar normalizada segundo padrões de lesões biomecânicos na zona da cabeça, cervical e anca/abdómen descritos na norma EN 1317 UNE 135900 – 1:2003, em alguns países é descurado o uso destas proteções, por não serem obrigatórias e porque ainda se tornam mais dispendiosas que as guardas de segurança habituais (barreiras de metal simples). Este estudo serviu essencialmente para verificar se estes dispositivos salvaguardam ou não a vida dos utilizadores de duas rodas, pois, se pelo contrário, aumentam ainda o risco, ou de lesões mais gravosas ou mesmo de morte, aquando o embate com as mesmas, os gastos associados a este tipo de equipamentos serão totalmente inúteis e desnecessários.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare hearing performance relating to the peripheral and central auditory system between solvent-exposed and non-exposed workers. METHODS: Forty-eight workers exposed to a mixture of solvents and 48 non-exposed control subjects of matched age, gender and educational level were selected to participate in the study. The evaluation procedures included: pure-tone audiometry (500 - 8,000 Hz), to investigate the peripheral auditory system; the Random Gap Detection test, to assess the central auditory system; and the Amsterdam Inventory for Auditory Disability and Handicap, to investigate subjects' self-reported hearing performance in daily-life activities. A Student t test and analyses of covariance (ANCOVA) were computed to determine possible significant differences between solvent-exposed and non-exposed subjects for the hearing level, Random Gap Detection test and Amsterdam Inventory for Auditory Disability and Handicap. Pearson correlations among the three measures were also calculated. RESULTS: Solvent-exposed subjects exhibited significantly poorer hearing thresholds for the right ear than non-exposed subjects. Also, solvent-exposed subjects exhibited poorer results for the Random Gap Detection test and self-reported poorer listening performance than non-exposed subjects. Results of the Amsterdam Inventory for Auditory Disability and Handicap were significantly correlated with the binaural average of subject pure-tone thresholds and Random Gap Detection test performance. CONCLUSIONS: Solvent exposure is associated with poorer hearing performance in daily life activities that relate to the function of the peripheral and central auditory system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify the prevalence of hearing loss for the population in the urban area. METHODS: A cross-sectional household survey based on the World Health Organization Ear and Hearing Disorders Survey Protocol was conducted in 298 households in the urban area of Monte Negro, Rondonia, Northern Brazil, from 2005 to 2007. Ear examinations, behavioral audiometry and pure tone audiometry were conducted on 577 individuals. RESULTS: The results showed that 3.8% (95%CI 2.17;5.45) of population were classified in the disabling hearing impairment category. The prevalence of moderate hearing impairment was 3.4%; severe impairment was 0.4%; and profound hearing impairment was not found. CONCLUSIONS: The impairing hearing loss prevalence found in this study is within of the international prevalence for this level of hearing loss and smaller than observed in a previous study in the South region of Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze the effectiveness of the Chilean System of Childhood Welfare in transferring benefits to socially vulnerable families. METHODS A cross-sectional study with a sample of 132 families from the Metropolitan Region, Chile, stratified according to degree of social vulnerability, between September 2011 and January 2012. Semi-structured interviews were conducted with mothers of the studied families in public health facilities or their households. The variables studied were family structure, psychosocial risk in the family context and integrated benefits from the welfare system in families that fulfill the necessary requirements for transfer of benefits. Descriptive statistics to measure location and dispersion were calculated. A binary logistic regression, which accounts for the sample size of the study, was carried out. RESULTS The groups were homogenous regarding family size, the presence of biological father in the household, the number of relatives living in the same dwelling, income generation capacity and the rate of dependency and psychosocial risk (p ≥ 0.05). The transfer of benefits was low in all three groups of the sample (≤ 23.0%). The benefit with the best coverage in the system was the Single Family Subsidy, whose transfer was associated with the size of the family, the presence of relatives in the dwelling, the absence of the father in the household, a high rate of dependency and a high income generation capacity (p ≤ 0.10). CONCLUSIONS The effectiveness of benefit transfer was poor, especially in families that were extremely socially vulnerable. Further explanatory studies of benefit transfers to the vulnerable population, of differing intensity and duration, are required in order to reduce health disparities and inequalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is the design of an optoelectronic circuit based on a-SiC technology, able to act simultaneously as a 4-bit binary encoder or a binary decoder in a 4-to-16 line configurations and show multiplexer-based logical functions. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n multilayered structure produced by PECVD. To analyze it under information-modulated wave (color channels) and uniform irradiation (background) four monochromatic pulsed lights (input channels): red, green, blue and violet shine on the device. Steady state optical bias was superimposed separately from the front and the back sides, and the generated photocurrent was measured. Results show that the devices, under appropriate optical bias, act as reconfigurable active filters that allow optical switching and optoelectronic logic functions development providing the possibility for selective removal of useless wavelengths. The logic functions needed to construct any other complex logic functions are the NOT, and both or either an AND or an OR. Any other complex logic function that might be found can also be used as building blocks to achieve the functions needed for the retrieval of channels within the WDM communication link. (C) 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In video communication systems, the video signals are typically compressed and sent to the decoder through an error-prone transmission channel that may corrupt the compressed signal, causing the degradation of the final decoded video quality. In this context, it is possible to enhance the error resilience of typical predictive video coding schemes using as inspiration principles and tools from an alternative video coding approach, the so-called Distributed Video Coding (DVC), based on the Distributed Source Coding (DSC) theory. Further improvements in the decoded video quality after error-prone transmission may also be obtained by considering the perceptual relevance of the video content, as distortions occurring in different regions of a picture have a different impact on the user's final experience. In this context, this paper proposes a Perceptually Driven Error Protection (PDEP) video coding solution that enhances the error resilience of a state-of-the-art H.264/AVC predictive video codec using DSC principles and perceptual considerations. To increase the H.264/AVC error resilience performance, the main technical novelties brought by the proposed video coding solution are: (i) design of an improved compressed domain perceptual classification mechanism; (ii) design of an improved transcoding tool for the DSC-based protection mechanism; and (iii) integration of a perceptual classification mechanism in an H.264/AVC compliant codec with a DSC-based error protection mechanism. The performance results obtained show that the proposed PDEP video codec provides a better performing alternative to traditional error protection video coding schemes, notably Forward Error Correction (FEC)-based schemes. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the authors intend to demonstrate the utilization of remote experimentation (RE) using mobile computational devices in the Science areas of the elementary school, with the purpose to develop practices that will help in the assimilation process of the subjects taught in classroom seeking to interlink them with the daily students? activities. Allying mobility with RE we intend to minimize the space-temporal barrier giving more availability and speed in the information access. The implemented architecture utilizes technologies and freely distributed softwares with open code resources besides remote experiments developed in the Laboratory of Remote Experimentation (RExLab) of Federal University of Santa Catarina (UFSC), in Brazil, through the physical computation platform of the ?open hardware of construction of our own. The utilization of open code computational tools and the integration of hardware to the 3D virtual worlds, accessible through mobile devices, give to the project an innovative face with a high potential for reproducibility and reusability.