954 resultados para HAND VEINS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Rapid pulmonary vein (PV) activity has been shown to maintain paroxysmal atrial fibrillation (AF). We evaluated in persistent AF the cycle length (CL) gradient between PVs and the left atrium (LA) in an attempt to identify the subset of patients where PVs play an important role. METHODS AND RESULTS Ninety-seven consecutive patients undergoing first ablation for persistent AF were studied. For each PV, the CL of the fastest activation was assessed over 1 minute (PVfast) using Lasso recordings. The PV to LA CL gradient was quantified by the ratio of PVfast to LA appendage (LAA) AF CL. Stepwise ablation terminated AF in 73 patients (75%). In the AF termination group, the PVfast CL was much shorter than the LAA CL resulting in lower PVfast/LAA ratios compared with the nontermination group (71±10% versus 92±7%; P<0.001). Within the termination group, PVfast/LAA ratios were notably lower if AF terminated after PV isolation or limited adjunctive substrate ablation compared with patients who required moderate or extensive ablation (63±6% versus 75±8%; P<0.001). PVfast/LAA ratio <69% predicted AF termination after PV isolation or limited substrate ablation with 74% positive predictive value and 95% negative predictive value. After a mean follow-up of 29±17 months, freedom from arrhythmia recurrence off-antiarrhythmic drugs was achieved in most patients with PVfast/LAA ratios <69% as opposed to the remaining population (80% versus 43%; P<0.001). CONCLUSIONS The PV to LA CL gradient may identify the subset of patients in whom persistent AF is likely to terminate after PV isolation or limited substrate ablation and better long-term outcomes are achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a method to acquire 3D light fields using a hand-held camera, and describe several computational photography applications facilitated by our approach. As our input we take an image sequence from a camera translating along an approximately linear path with limited camera rotations. Users can acquire such data easily in a few seconds by moving a hand-held camera. We include a novel approach to resample the input into regularly sampled 3D light fields by aligning them in the spatio-temporal domain, and a technique for high-quality disparity estimation from light fields. We show applications including digital refocusing and synthetic aperture blur, foreground removal, selective colorization, and others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research in cognitive sciences shows a growing interest in spatial-numerical associations. The horizontal SNARC (spatial-numerical association of response codes) effect is defined by faster left-sided responses to small numbers and faster right-sided responses to large numbers in a parity judgment task. In this study we investigated whether there is also a SNARC effect for upper and lower responses. The grounded cognition approach suggests that the universal experience of "more is up" serves as a robust frame of reference for vertical number representation. In line with this view, lower hand responses to small numbers were faster than to large numbers (Experiment 1). Interestingly, the vertical SNARC effect reversed when the lower responses were given by foot instead of the hand (Experiments 2, 3, and 4). We found faster upper (hand) responses to small numbers and faster lower (foot) responses to large numbers. Additional experiments showed that spatial factors cannot account for the reversal of the vertical SNARC effect (Experiments 4 and 5). Our results question the view of "more is up" as a robust frame of reference for spatial-numerical associations. We discuss our results within a hierarchical framework of numerical cognition and point to a possible link between effectors and number representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE This study aimed to examine the work-related impact of open hand injuries, specifically, the amount of lost work days subsequent to the injury and factors associated with work-related rehabilitation. PATIENTS AND METHODS We retrospectivley included consecutive patients with acute hand injuries who were operated between 2008 and 2009 in the Division of Hand Surgery (n=435) at the Department of Orthopaedic, Plastic and Hand Surgery. Information was obtained from the medical records and via a self-reported questionnaire sent out in 2011. Patients younger than 18 or older than 65 years, as well as the unemployed were excluded from the study. Descriptive group analysis was used to establish statistical relationships between time off work (TOW) and possible influencing variables. Multiple linear regression was applied to analyse the impact of injury, personal and/or work-related factors on TOW. RESULTS The sample included 290 patients with a mean age of 38.9 (SD 13.2) years of whom 98.6% returned to work after a median absence of 45.5 days. Univariate analysis demonstrated an association of length of absence from work with socio-demographic, clinical and work-related factors. Multiple regression analysis indicated that the location of injury, the number of injured regions, the need for secondary surgery, age, and the type of occupation were independently associated with TOW. CONCLUSION Most factors associated with TOW after traumatic hand injuries could not be influenced. Possible interventions should probably target improved injury prevention, optimal clinical treatment and rehabilitation starting early after injury. Whether improvements in communication and enhancement of cooperation between the treatment teams, the workplace and the insurance carrier may support a staged and earlier return to work remains to be investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract PRINCIPLES: Computed tomography (CT) is inferior to the fibroscan and laboratory testing in the noninvasive diagnosis of liver fibrosis. On the other hand, CT is a frequently used diagnostic tool in modern medicine. The auxiliary finding of clinically occult liver fibrosis in CT scans could result in an earlier diagnosis. The aim of this study was to analyse quantifiable direct signs of liver remodelling in CT scans to depict liver fibrosis in a precirrhotic stage. METHODS: Retrospective review of 148 abdominal CT scans (80 liver cirrhosis, 35 precirrhotic fibrosis and 33 control patients). Fibrosis and cirrhosis were histologically proven. The diameters of the three main hepatic veins were measured 1-2 cm before their aperture into the inferior caval vein. The width of the caudate and the right hepatic lobe were divided, and measured horizontally at the level of the first bifurcation of the right portal vein in axial planes (caudate-right-lobe ratio). A combination of both (sum of liver vein diameters divided by the caudate-right lobe ratio) was defined as the ld/crl ratio. These metrics were analysed for the detection of liver fibrosis and cirrhosis. RESULTS: An ld/crl-r <24 showed a sensitivity of 83% and a specificity of 76% for precirrhotic liver fibrosis. Liver cirrhosis could be detected with a sensitivity of 88% and a specificity of 82% if ld/crl-r <20. CONCLUSION: An ld/crl-r <24 justifies laboratory testing and a fibroscan. This could bring forward the diagnosis and patients would profit from early treatment in a potentially reversible stage of disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Guidelines recommend that health care personnel (HCP) wear gloves for all interactions with patients on contact precautions. We aimed to assess hand hygiene (HH) compliance during contact precautions before and after eliminating mandatory glove use. METHODS We assessed HH compliance of HCP in the care of patients on contact precautions in 50 series before (2009) and 6 months after (2012) eliminating mandatory glove use and compared these results with the hospital-wide HH compliance. RESULTS We assessed 426 HH indications before and 492 indications after the policy change. Compared with 2009, we observed a significantly higher HH compliance in patients on contact precautions in 2012 (52%; 95% confidence interval [95% CI], 47-57) vs 85%; 95% CI, 82-88; P < .001). During the same period, hospital-wide HH compliance also increased from 63% (95% CI, 61-65) to 81% (95% CI 80-83) (P < .001). However, the relative improvement (RI) of HH compliance during contact precautions was significantly higher than the hospital-wide relative improvement (RI, 1.6; 95% CI, 1.49-1.81 vs 1.29; 95% CI, 1.25-1.34), with a relative improvement ratio of 1.27 (95% CI, 1.15-1.41). CONCLUSION Eliminating mandatory glove use in the care of patients on contact precautions increased HH compliance in our institution, particularly before invasive procedures and before patient contacts. Further studies on the effect on pathogen transmission are needed before revisiting the current official guidelines on the topic.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research investigated how an individual’s endorsements of mitigation and adaptation relate to each other, and how well each of these can be accounted for by relevant social psychological factors. Based on survey data from two European convenience samples (N = 616 / 309) we found that public endorsements of mitigation and adaptation are strongly associated: Someone who is willing to reduce greenhouse gas emissions (mitigation) is also willing to prepare for climate change impacts (adaptation). Moreover, people endorsed the two response strategies for similar reasons: People who believe that climate change is real and dangerous, who have positive attitudes about protecting the environment and the climate, and who perceive climate change as a risk, are willing to respond to climate change. Furthermore, distinguishing between (spatially) proximal and distant risk perceptions suggested that the idea of portraying climate change as a proximal (i.e., local) threat might indeed be effective in promoting personal actions. However, to gain endorsement of broader societal initiatives such as policy support, it seems advisable to turn to the distant risks of climate change. The notion that “localising” climate change might not be the panacea for engaging people in this domain is discussed in regard to previous theory and research.