951 resultados para Gaseous detectors


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Application of Experimental Design techniques has proven to be essential in various research fields, due to its statistical capability of processing the effect of interactions among independent variables, known as factors, in a system’s response. Advantages of this methodology can be summarized in more resource and time efficient experimentations while providing more accurate results. This research emphasizes the quantification of 4 antioxidants extraction, at two different concentration, prepared according to an experimental procedure and measured by a Photodiode Array Detector. Experimental planning was made following a Central Composite Design, which is a type of DoE that allows to consider the quadratic component in Response Surfaces, a component that includes pure curvature studies on the model produced. This work was executed with the intention of analyzing responses, peak areas obtained from chromatograms plotted by the Detector’s system, and comprehending if the factors considered – acquired from an extensive literary review – produced the expected effect in response. Completion of this work will allow to take conclusions regarding what factors should be considered for the optimization studies of antioxidants extraction in a Oca (Oxalis tuberosa) matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interest in chromium (Cr) arises from the widespread use of this heavy metal in various industrial processes that cause its release as liquid, solid and gaseous waste into the environment. The impact of Cr on the environment and living organisms primarily depends on its chemical form, since Cr(III) is an essential micronutrient for humans, other animals and plants, and Cr(VI) is highly toxic and a known human carcinogen. This study aimed to evaluate if the electrodialytic process (ED) is an appropriate treatment for Cr removal, through a critical overview of Cr speciation, before and after the ED experiments, to assess possible Cr(III)-Cr(VI) interconversions during the treatment. ED was the treatment technique applied to two types of matrices containing Cr: chromate copper arsenate (CCA) contaminated soil and municipal solid waste incineration (MSWI) fly ash. In order to study Cr remediation, three EDR set-ups were used: a new set-up, the combined cell (2/3C or 3/2C), with three compartments, alternating current between two anodes and different initial experimental conditions, one set-up with three compartments (3C cell) and the other set-up with two compartments (2C cell). The Cr removal rates obtained in this study were between 10-36% for the soil, and 1-13% for the fly ash. The highest Cr removal rates were achieved in the 26 days experiments: 36% for the soil, 13% for the fly ash. Regarding the 13 days experiments, the highest Cr removal rates were attained with the 2/3C set-up: 24% for the soil, 5% for the fly ash. The analysis of Cr(VI) was performed before and after ED experiments to evaluate eventual changes in Cr speciation during the treatment. This analysis was conducted by two methods: USEPA Method 3060A, for the extraction of Cr(VI); and Hach Company Method 8023, for the detection of Cr(VI). Despite the differences in Cr total concentration, both matrices presented a similar speciation, with Cr(III) being the main species found and Cr(VI) less than 3% of Cr total, before and after the treatment. For fly ash, Cr(VI) was initially below the detection limit of the method and remained that way after the treatment. For soil, Cr(VI) decreased after the treatment. Oxidation of Cr(III) to Cr(VI) did not occur during the ED process since there was no increase in Cr(VI) in the matrices after the treatment. Hence, the results of this study indicate that ED is an appropriate technique to remediate matrices containing Cr because it contributes to Cr removal, without causing Cr(III)-Cr(VI) interconversions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Documento submetido para revisão pelos pares. A publicar em Journal of Parallel and Distributed Computing. ISSN 0743-7315

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple procedure for the simultaneous detection of cyclopiazonic acid (CPA) and aflatoxin B1 from fungal extracts is presented, using a methanol and water mobile phase and fluorescence detection. This methodology has been tested with standard solutions of both mycotoxins CPA and Aflatoxin B1 and with methanolic extracts of Aspergillus section Flavi strains, previously characterized for their mycotoxin production profile. Previously available methodology required the use of two different chromatographic runs for these mycotoxins, with distinct columns and detectors (fluorescence detection with a post-column photochemical derivatization (PHRED) for aflatoxin B1 and UV detection for CPA). The proposed method detects both mycotoxins in a single run. Data from these assays will be presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioengenharia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Programa Doutoral em Engenharia Mecânica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effect of endogenous estrogens on the bioavailability of nitric oxide (·NO) and in the formation of lipid peroxidation products in pre- and postmenopausal women. METHODS: NOx and S-nitrosothiols were determined by gaseous phase chemiluminescence, nitrotyrosine was determined by ELISA, COx (cholesterol oxides) by gas chromatography, and cholesteryl linoleate hydroperoxides (CE18:2-OOH), trilinolein (TG18:2-OOH), and phospholipids (PC-OOH) by HPLC in samples of plasma. RESULTS: The concentrations of NOx, nitrotyrosine, COx, CE18:2-OOH, and PC-OOH were higher in the postmenopausal period (33.8±22.3 mM; 230±130 nM; 55±19 ng/mL; 17±8.7 nM; 2775±460 nM, respectively) as compared with those in the premenopausal period (21.1±7.3 mM; 114±41 nM; 31±13 ng/mL; 6±1.4 nM; 1635±373 nM). In contrast, the concentration of S-nitrosothiols was lower in the postmenopausal period (91±55 nM) as compared with that in the premenopausal p in the premenopausal period (237±197 nM). CONCLUSION: In the postmenopausal period, an increase in nitrotyrosine and a reduction of S-nitrosothiol formation, as well as an increase of COx, CE18:2-OOH and PC-OOH formation occurs. Therefore, •NO inactivation and the increase in lipid peroxidation may contribute to endothelial dysfunction and to the greater risk for atherosclerosis in postmenopausal women.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at Albert Einstein Institut in Germany, from April to July 2006.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treball de recerca realitzat per un alumne d’ensenyament secundari i guardonat amb un Premi CIRIT per fomentar l'esperit científic del Jovent l’any 2006. La construcció d'un microrobot autònom capaç de realitzar una funció per ell mateix, ha permès exposar una introducció en el món de l'electrònica i la mecànica pràctiques. Es tracta d’un microrobot rastrejador: capaç de seguir una línia pintada al terra, per mitjà d'unes entrades (sensors detectors de llum), una lògica (C.I. operacionals) i uns motors motrius comandats per mitjà d'un C.I. driver. S’adjunten imatges dels resultats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2 ) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low-pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este informe se estudia cómo es posible utilizar redes de sensores inalámbricos (WSN), para la localización de determinados eventos. Se hace un estudio previo de cómo una red de sensores puede llegar a estar sincronizada de una manera cooperativa, interactuando todos los sensores de la red entre sí. Primero se realiza el estudio para la sincronización de dos sensores con frecuencias diferentes, viéndose los parámetros que intervienen para que esta sincronización se realice con éxito, y también los efectos que en ella se produce al añadirle ruido. Seguidamente, se realiza el estudio para la sincronización de redes de N sensores, de manera que interactúen entre ellos de forma cooperativa. Se observan las características de la sincronización cuando todos los sensores llegan a consenso y, después, se busca la forma para que el consenso tienda hacia un valor determinado por mutuo acuerdo de los sensores. Finalmente, a partir de las características obtenidas en el consenso de N sensores, se realiza una aplicación práctica para la localización de eventos por medio del consenso de estas redes de sensores inalámbricos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treball de recerca realitzat per un alumne d’ensenyament secundari i guardonat amb un Premi CIRIT per fomentar l'esperit científic del Jovent l’any 2008. La nanobiotecnologia és una branca de la nanociència i/o nanotecnologia que previsiblement tindrà un gran creixement i impacte durant els propers anys en molts camps i especialment en el de la diagnosi i tractament de malalties. Això requereix disposar de biosensors a escala nanomètrica que siguin molt sensibles i selectius enfront d’agents químics i biològics, a fi de poder obtenir dades en temps real “in situ” a nivell cel•lular i facilitar tractaments específics i personalitzats. Un petit pas previ als nanobiosensors són els microsensors químics, que poden ser fàcilment implantats en teixits humans sense lesionar-los i proporcionar mesures freqüents o contínues del pH o de la concentració de diversos ions que són dades importants per determinar l’estat de salut d’una persona. Els sensors ISFET tenen una configuració que els permet detectar i mesurar les concentracions de ions H+, per tant mesuren el pH. Entre les seves aplicacions hi destaca la gran eficàcia en la detecció del ió H+ en petites concentracions, que, entre altres usos com els biomèdics, és de gran importància en la mesura de la qualitat dels terrenys de cultiu. Si el sensor tipus ISFET és modificat mitjançant una membrana, com es fa en el present treball, pot desenvolupar moltes aplicacions en el camp de la salut, com és el cas de la detecció de cèl•lules mortes dins el cos humà, i per tant detectar de manera precoç la necrosi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUM En aquest document es presenta un detector de contorns d’imatges basat en el domini transformat. A partir de la interpretació de la transformada de Fourier de la imatge i la seva formulació matricial en termes dels diferents modes, es realitza una selecció de les components passa baixes a partir de les quals es reconstrueix la component de baixa freqüència que es resta de la imatge original per tal d’obtenir el detector. Aquest detector de contorns no és esbiaixat. L’algorisme pot ser aplicat utilitzant diferents mides del bloc de processament, que pot anar de la imatge sencera a blocs de reduïdes dimensions: 36X36, 16x16 o 8x8, per fer un seguiment de les propietats locals de la imatge quan aquesta és presenta característiques espacials poc uniformes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of Geographic Information Systems has revolutionalized the handling and the visualization of geo-referenced data and has underlined the critic role of spatial analysis. The usual tools for such a purpose are geostatistics which are widely used in Earth science. Geostatistics are based upon several hypothesis which are not always verified in practice. On the other hand, Artificial Neural Network (ANN) a priori can be used without special assumptions and are known to be flexible. This paper proposes to discuss the application of ANN in the case of the interpolation of a geo-referenced variable.