1000 resultados para Estabilidade dimensional
Resumo:
Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.
Resumo:
In this paper a model is developed to describe the three dimensional contact melting process of a cuboid on a heated surface. The mathematical description involves two heat equations (one in the solid and one in the melt), the Navier-Stokes equations for the flow in the melt, a Stefan condition at the phase change interface and a force balance between the weight of the solid and the countering pressure in the melt. In the solid an optimised heat balance integral method is used to approximate the temperature. In the liquid the small aspect ratio allows the Navier-Stokes and heat equations to be simplified considerably so that the liquid pressure may be determined using an igenfunction expansion and finally the problem is reduced to solving three first order ordinary differential equations. Results are presented showing the evolution of the melting process. Further reductions to the system are made to provide simple guidelines concerning the process. Comparison of the solutions with experimental data on the melting of n-octadecane shows excellent agreement.
Resumo:
Aspergillus lentulus, an Aspergillus fumigatus sibling species, is increasingly reported in corticosteroid-treated patients. Its clinical significance is unknown, but the fact that A. lentulus shows reduced antifungal susceptibility, mainly to voriconazole, is of serious concern. Heterologous expression of cyp51A from A. fumigatus and A. lentulus was performed in Saccharomyces cerevisiae to assess differences in the interaction of Cyp51A with the azole drugs. The absence of endogenous ERG11 was efficiently complemented in S. cerevisiae by the expression of either Aspergillus cyp51A allele. There was a marked difference between azole minimum inhibitory concentration (MIC) values of the clones expressing each Aspergillus spp. cyp51A. Saccharomyces cerevisiae clones expressing A. lentulus alleles showed higher MICs to all of the azoles tested, supporting the hypothesis that the intrinsic azole resistance of A. lentulus could be associated with Cyp51A. Homology models of A. fumigatus and A. lentulus Cyp51A protein based on the crystal structure of Cyp51p from Mycobacterium tuberculosis in complex with fluconazole were almost identical owing to their mutual high sequence identity. Molecular dynamics (MD) was applied to both three-dimensional protein models to refine the homology modelling and to explore possible differences in the Cyp51A-voriconazole interaction. After 20ns of MD modelling, some critical differences were observed in the putative closed form adopted by the protein upon voriconazole binding. A closer study of the A. fumigatus and A. lentulus voriconazole putative binding site in Cyp51A suggested that some major differences in the protein's BC loop could differentially affect the lock-up of voriconazole, which in turn could correlate with their different azole susceptibility profiles.
Resumo:
PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.
Resumo:
The choice of sample preparation protocol is a critical influential factor for isoelectric focusing which in turn affects the two-dimensional gel result in terms of quality and protein species distribution. The optimal protocol varies depending on the nature of the sample for analysis and the properties of the constituent protein species (hydrophobicity, tendency to form aggregates, copy number) intended for resolution. This review explains the standard sample buffer constituents and illustrates a series of protocols for processing diverse samples for two-dimensional gel electrophoresis, including hydrophobic membrane proteins. Current methods for concentrating lower abundance proteins, by removal of high abundance proteins, are also outlined. Finally, since protein staining is becoming increasingly incorporated into the sample preparation procedure, we describe the principles and applications of current (and future) pre-electrophoretic labelling methods.
Resumo:
RATIONALE AND OBJECTIVES: Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. MATERIALS AND METHODS: Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. RESULTS: High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. CONCLUSION: Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.
Resumo:
PURPOSE: To investigate the feasibility of high-resolution selective three-dimensional (3D) magnetic resonance coronary angiography (MRCA) in the evaluation of coronary artery stenoses. MATERIALS AND METHODS: In 12 patients with coronary artery stenoses, MRCA of the coronary artery groups, including the coronary segments with stenoses of 50% or greater based on conventional x-ray coronary angiography (CAG), was performed with double-oblique imaging planes by orienting the 3D slab along the major axis of each right coronary artery-left circumflex artery (RCA-LCX) group and each left main trunk-left anterior descending artery (LMT-LAD) group. Ten RCA-LCX and five LMT-LAD MR angiograms were obtained, and the results were compared with those of conventional x-ray angiography. RESULTS: Among 70 coronary artery segments expected to be covered, a total of 49 (70%) segments were fully demonstrated in diagnostic quality. The identification of segmental location of stenoses showed as high an accuracy as 96%. The retrospective analysis for stenosis of 50% or greater yielded the sensitivity, specificity, and accuracy of 80%, 85%, and 84%, respectively. CONCLUSION: Selective 3D MRCA has the potential for segment-by-segment evaluation of major portions of the right and left coronary arteries with high accuracy.
Resumo:
To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).
Resumo:
Conventional coronary magnetic resonance angiography (MRA) techniques display the coronary blood-pool along with the surrounding structures, including the myocardium, the ventricular and atrial blood-pool, and the great vessels. This representation of the coronary lumen is not directly analogous to the information provided by x-ray coronary angiography, in which the coronary lumen displayed by iodinated contrast agent is seen. Analogous "luminographic" data may be obtained using MR arterial spin tagging (projection coronary MRA) techniques. Such an approach was implemented using a 2D selective "pencil" excitation for aortic spin tagging in concert with a 3D interleaved segmented spiral imaging sequence with free-breathing, and real-time navigator technology. This technique allows for selective 3D visualization of the coronary lumen blood-pool, while signal from the surrounding structures is suppressed.
Resumo:
Several different sample preparation methods for two-dimensional electrophoresis (2-DE) analysis of Leishmania parasites were compared. From this work, we were able to identify a solubilization method using Nonidet P-40 as detergent, which was simple to follow, and which produced 2-DE gels of high resolution and reproducibility.
Resumo:
Es presenta una sèrie de conceptes de semblança molecular quàtica i uns procediments associats de càlcul i representació gràfica dels resultats. Donada una sèrie de molècules es poden obtenir diversos tipus de gràfics que mostren les relacions entre elles. Com a exemple d'aplicació d'aquest procés s'estudia una família de drogues antitumorals
Resumo:
We present herein a topological invariant of oriented alternating knots and links that predicts the three-dimensional (3D) writhe of the ideal geometrical configuration of the considered knot/link. The fact that we can correlate a geometrical property of a given configuration with a topological invariant supports the notion that the ideal configuration contains important information about knots and links. The importance of the concept of ideal configuration was already suggested by the good correlation between the 3D writhe of ideal knot configurations and the ensemble average of the 3D writhe of random configurations of the considered knots. The values of the new invariant are quantized: multiples of 4/7 for links with an odd number of components (including knots) and 2/7 plus multiples of 4/7 for links with an even number of components.