986 resultados para ENAMEL THICKNESS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To assess the prevalences of caries, of developmental defects of enamel and their interrelationship in Brazilian 9-10-year-olds from areas of contrasting fluoridation histories.Methods systematic random sampling procedures were used to select children from an area where water had been fluoridated in 1963 and from a second area where water had been fluoridated since 1998. Clinical examinations for caries were carried out using the DMFT index and WHO diagnostic criteria. Developmental defects of enamel on upper incisors were diagnosed using the DDE index.Results A difference of 40% in DMFT was observed, with a lower prevalence of disease in the area fluoridated since 1963. Diffuse opacities affected 14.3% of the children from the area fluoridated since 1963 compared with only 2.4% in the area fluoridated in 1998. Children living in the area fluoridated in 1963 who had diffuse defects had twice the chance of being free from caries compared with those living in the same area who had no defects or who had only demarcated or hypoplastic defects.Conclusions This study confirms previous ones in showing the benefits of water fluoridation. Diffuse opacities of upper incisors affected relatively few subjects in either of the two areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the microhardness of enamel treated with two different 10% carbamide peroxide bleaching materials at different time intervals. Materials and Methods: Two bleaching agents were analyzed: Opalescence (OPA) and Rembrandt (REM). The control group (CON) consisted of dental fragments maintained in artificial saliva. Bleaching was accomplished for 8 hrs per day and stored during the remaining time in an individual recipient with artificial saliva. Enamel microhardness testing was performed before the initial exposure to the treatments and after 1, 7, 14, 21, 28, 35 and 42 days. Results: the ANOVA, followed by the Bartlet and Tukey tests, showed significant differences for treatments (P < 0.00001) from day 7-day 42. From the 7th to the 14th day, OPA presented an increase of enamel microhardness over time while REM presented a decrease of microhardness. Statistical differences were not found between REM and the control group (OPA > CON = REM). From the 21st-35th day, enamel fragments bleached with OPA and REM presented a decrease of microhardness. Statistical differences of microhardness were verified among all the treatments (OPA > CON > REM). on the day 42, statistical differences were not found between OPA and the control group, but they were found between REM and the control group (OPA = CON > REM). The polynomial regression showed an increase of microhardness for OPA until the 21st day, followed by a decrease of microhardness up to the 42nd day. A decrease of microhardness for REM was verified. There were alterations in enamel microhardness as a function of bleaching time when using the two different 10% carbamide peroxide whiteners. Over a 42-day treatment time, bleaching with REM agent caused a decrease in enamel microhardness. The OPA agent initially increased the microhardness, then returned to the control level. Different bleaching materials with the same concentration of carbamide peroxide have different effects on the enamel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of edible films are influenced by several factors, including thickness. The purpose of this paper was to study the influence of thickness on the viscoelasticity properties, water vapor permeability, color and opacity of cassava starch edible films. These films were prepared by a casting technique, the film-forming solutions were 1, 2, 3 and 4% (w/v) of starch, heated to 70degreesC. Different thicknesses were obtained by putting 15 to 70 g of each solution on plexiglass plates. After drying at 30degreesC and ambient relative humidity, these samples were placed for 6 days at RH of 75%, at 22degreesC. The sample thicknesses were determined by a digital micrometer (+/-0.001 mm), as the average of nine different points. The viscoelasticity properties were determined by stress relaxation tests with a texture analyser TA.XT2i (SMS), being applied the Burgers model of four parameters. The water vapor permeability was determined with a gravimetric method, and color and opacity were determined using a Miniscan XE colorimeter, operated according to the Hunterlab method. All the tests were carried out in duplicate at 22degreesC. Practically, the four visco-elasticity properties calculated by the Burgers model had the same behavior, increasing with the thickness of all films, according to a power law model. The water vapor permeability and the color difference increased linearly with the thickness (0.013-0.144 mm) of all films prepared with solution of 1 to 4% of starch. on the other hand, the effect of the variation of the thickness over the opacity, was more important in the films with 1 and 2% of starch. It can be concluded that the control of the thickness in the elaboration of starch films by the casting technique is of extreme importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Highly polished enamel surfaces arc recommended for axial tooth surfaces that will serve as guiding planes and be contacted by component parts of a removable partial denture. There is little evidence to support the assumption that this tooth modification will provide accurate adaptation of the framework and prevent build-up of plaque.Purpose. The aim of this investigation was to evaluate the surface roughness of the tooth enamel, prepared to serve as guiding planes, with different polishing systems.Material and methods. Four different methods (designated A, B, C, and D) for finishing and polishing the prepared enamel surfaces of 20 freshly extracted third molar teeth were studied. Each method involved 3, 4, or 5 different steps. The roughness of each specimen was measured at the start of each method before recontouring, after recontouring, and after each step of the 4 finishing and polishing procedures. The 4 experimental finishing methods were applied after recontouring the axial surfaces (buccal, lingual, and proxinial) of each tooth. Thus the 20 teeth (60 surfaces) were finished and polished by use of 1 of the experimental methods. Surface roughness was measured with a profilometer (mum); the readings of the unpolished enamel Surfaces were recorded as control measurements. Results were statistically analyzed with one-way analysis of variance followed by Tukey's test at the 95% level of confidence.Results. The highest roughness mean values (14.41 mum to 16.44 mum) were found when the diamond bur was used at a high speed for tooth preparation. A significant decrease in roughness values was observed with the diamond bur at a low speed (P<.05). Analysis of the roughness values revealed that all polishing methods produced surface roughness similar to that of the corresponding control teeth.Conclusion. Within the limitations of this study, all finishing procedures tested effectively promoted an enamel surface similar to the original unpolished enamel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discoloration of non-vital teeth is an esthetic deficiency frequently requiring bleaching treatment. The purpose of this study was to evaluate in vitro the cervical base efficacy in order to prevent or to minimize the leakage along the root canal filling and into the dentinal tubules. Thirty-eight extracted single-root human teeth were used, which were biomechanically prepared, filled, and divided into three experimental groups: G1, a cervical base was applied (3 mm of thickness) below the cemento-enamel junction, with resin-modified glass-ionomer cement (Vitremer); G2, the base was done with glass-ionomer cement (Vidrion R); and G3 (Control), did not receive any material as base. A mixture of sodium perborate and hydrogen peroxide 30% was placed inside the pulp chamber for 3 days, and the access opening was sealed with Cimpat. This procedure was repeated thrice. Soon after this, a paste of calcium hydroxide was inserted into the pulp chamber for 14 days. All teeth were covered with two layers of sticky wax, except the access opening, and immersed in blue India Ink for 5 days. The results did not show statistically significant differences between the three groups concerning the leakage inside the dentinal tubules. Regarding the apical direction, a statistical difference (ANOVA P < 0.05) was observed among the experimental group G1 and control group G3. No statistically significant difference was observed between G2 and G3 groups. Therefore, the placement of a cervical base before internal bleaching procedures is still recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BaBi2Ta2O9 thin films having a layered structure were fabricated by metalorganic solution deposition technique. The films exhibited good structural, dielectric, and insulating properties. The room temperature resistivity was found to be in the range of 10(12)-10(14) Omega cm up to 4 V corresponding to a field of 200 kV/cm across the capacitor for films annealed in the temperature range of 500-700 degrees C. The current-voltage (I-V) characteristics as a function of thickness for films annealed at 700 degrees C for 1 h, indicated bulk limited conduction and the log(I) vs V-1/2 characteristics suggested a space-charge-limited conduction mechanism. The capacitance-voltage measurements on films in a metal-insulator-semiconductor configuration indicated good Si/BaBi2Ta2O9 interface characteristics and a SiO2 thickness of similar to 5 nm was measured and calculated. (C) 1999 American Institute of Physics. [S0003-6951(99)00830-X].