925 resultados para DROP-OUTS
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia cardiovascular
Resumo:
An experimental and numerical investigation into the shear strength behaviour of adhesive single lap joints (SLJs) was carried out in order to understand the effect of temperature on the joint strength. The adherend material used for the experimental tests was an aluminium alloy in the form of thin sheets, and the adhesive used was a high-strength high temperature epoxy. Tensile tests as a function of temperature were performed and numerical predictions based on the use of a bilinear cohesive damage model were obtained. It is shown that at temperatures below Tg, the lap shear strength of SLJs increased, while at temperatures above Tg, a drastic drop in the lap shear strength was observed. Comparison between the experimental and numerical maximum loads representing the strength of the joints shows a reasonably good agreement.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Bancroftian filariasis is spreading in towns of endemic areas as in Recife, northeastern Brazil, where it is a major public health problem. This paper deals with the prevalence of microfilaraemia and filarial disease in two urban areas of Recife, studying their association with individual characteristics and variables related to the exposure to the vectors. The parasitologic survey was performed through a "door-to-door" census and microfilaraemia was examined by the thick-drop technique using 45µl of peripheral blood collected between 20:00 and 24:00 o' clock. 2,863 individuals aged between 5 and 65 years were interviewed and submitted to clinical examination. Males aged between 15 and 44 years old presented the greatest risk of being microfilaraemic. Microfilaraemia was also significantly associated with no use of bednet to sleep. The risk of being microfilaraemic was greater among those who had lived in the studied areas for more than 5 years. The overall disease prevalence was 6.3%. Males presented the greatest risk of developing acute disease. The risk of developing chronic manifestations was also greater among males and increased with age. We found no association between time of residence, bednet use, microfilaraemia and acute and chronic disease. We may conclude that in endemic areas there are subgroups of individuals who has a higher risk of being microfilariae carriers due to different behaviours in relation to vector contact.
Resumo:
Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.
Resumo:
No dia-a-dia, os organismos vivos estão sujeitos a vários tipos de agressões de origem endógena e exógena. A produção endógena exagerada de agentes oxidantes que ocorre nos processos metabólicos dos seres vivos está intimamente associada ao aparecimento e desenvolvimento de várias patologias. Por outro lado, e devido às atividades antropogénicas, muitos agentes oxidantes de origem ambiental e alimentar entram por via exógena no organismo dos seres vivos provocando igualmente danos a nível celular. De modo a protegerem-se dos efeitos pejorativos provocados por estes compostos, os organismos vivos desenvolveram mecanismos complexos de defesa antioxidante. Este trabalho consistiu no estudo eletroquímico do dano oxidativo induzido por agentes oxidantes (PAH (hidrocarbonetos aromáticos policíclicos), H2O2, NO• e HClO) e do efeito protetor, ao dano oxidativo, promovido por antioxidantes no material baseado no ADN recorrendo à utilização de um biossensor de bases púricas, adenina-EPC (elétrodo pasta de carbono) e dA20-EPC, utilizando a voltametria de onda quadrada (VOQ) como técnica de deteção. A aplicação da eletroquímica apresenta várias vantagens para a quantificação da capacidade antioxidante total (CAT) pois, permite a redução da quantidade de reagentes e amostra em análise, elimina a etapa de remoção de cor (a cor é um interferente nos métodos óticos) e não requer equipamentos dispendiosos. Foram seguidas diferentes abordagens para a construção dos biossensores. A primeira consistiu na construção de um adenina-EPC em três etapas: i) condicionamento do EPC, ii) eletrodeposição da adenina no EPC e iii) leitura do sinal eletroquímico. Assim, foram otimizados diversos parâmetros: concentração de adenina (150,0 mg/L), potencial de condicionamento (Ec) (+ 1,80 V), potencial de deposição (Ed) (+ 0,40 V), tempo de condicionamento (tc) (180 s) e tempo de deposição (td) (240 s). Foi aplicado o adenina-EPC no estudo do dano oxidativo provocado por PAH (benzo (g,h,i) perileno) e constatou-se que era necessário transformar o benzo (g,h,i) perileno num radical para se possível observar danos oxidativos induzidos no biossensor. A nova estratégia consistiu na construção de um dA20-EPC, através da adsorção física de uma gota de dA20 na superfície do EPC, com posterior secagem e leitura do sinal eletroquímico. Neste procedimento foi otimizada a concentração de dA20 (100,0 mg/L). O dano oxidativo provocado pelo H2O2, NO• e HClO foi estudado sobre o dA20-EPC e verificou-se que os três agentes oxidantes induziam dano oxidativo no dA20-EPC. Confirmou-se a capacidade do ácido ascórbico (AA) em proteger o dA20-EPC do dano oxidativo induzido por H2O2 e NO•. O biossensor desenvolvido (dA20-EPC) foi aplicado na avaliação da CAT de diferentes amostras reais (café, sumo de laranja e água aromatizada de laranja) usando-se como agentes oxidantes o H2O2 e NO•. Todas as amostras analisadas apresentaram ter capacidade antioxidante. Quando se utilizou o dA20-EPC na presença de H2O2, verificou-se que as amostras de café apresentam valores mais elevados de CAT (1130-1488 mg AAE/L) do que as amostras de bebidas (110 mg AAE/L em água aromatizada e 775 mg AAE/L em sumo). Os valores de CAT obtidos para amostras de sumo e água aromatizada na presença de NO• indicam que a amostra de sumo possui maior teor de CAT (871 mg AAE/L) conforme era esperado, do que a amostra de água aromatizada (172 mg AAE/L). Na presença de HClO, o valor de CAT mais elevado pertence a uma amostra de sumo (513 mg AAE/L) mas, o valor de CAT da amostra de sumo natural é muito mais baixa do que o esperado (17 mg AAE/L). Foram estudados outros antioxidantes para além do AA (ácido cumárico, ácido gálico e ácido cafeico), e constatou-se que cada um deles promove proteção ao dA20-EPC na presença de cada um dos diferentes contaminantes (H2O2, NO• e HClO).
Resumo:
The objective of the article is to evaluate the impact of the friction force mouse-pad in the contraction level of the forearm muscles M. extensor carpi ulnaris, M. extensor digitorum and M. extensor carpi radialis longus. A standard protocol of mouse movements was performed involving horizontal, vertical and diagonal mouse displacements drag-and-drop type. The operators were instructed to execute the protocol with their normal working speed. The movements protocol were performed by each subject (n=17) with three selected pairs mouse-pad, classified as low, medium and high friction force pairs. The mean time to execute the protocol with each mouse was ~138s. Mean values of ~13%MVE and ~17%MVE were found in the M. extensor carpi ulnaris and in the M. extensor digitorum respectively when performing the movements’ protocol. A 8.1% increase in %MVE was observed in the M. extensor digitorum and a 9.4% increase in %MVE was observed in the M. extensor carpi ulnaris when the high friction force pair was operated, relatively to the low friction force pair (p<0.05). The main preliminary conclusions of this study is that operating a high friction force mouse-pad may increase the risk to symptoms or disorders in the wrist due to an increase in the forearm muscles contraction levels, particularly during work with drawing application
Resumo:
Leishmanias can be produced by inoculation in conditioned McCoy cell culture growth medium (CGM). Leishmania (Leishmania) infantum chagasi (100 parasites) grown in NNN medium was inoculated in 2.5 mL CGM, kept in plates (24 wells) and its multiplication was observed for five days (120 hours). After day 5, the medium was saturated with the flagellate forms of the parasite (promastigotes). The reproduction of the leishmanias was observed every 24 hours and the number of parasites was calculated by counting the parasites in a drop of 10 µ L and photomicrographied. So the number of Leishmanias was adjusted to 1 mL volume. The advantage of the technique by isolation of Leishmania in CGM demonstrated in this study is its low cost and high efficacy even with a small quantity of parasites (10² promastigotes) used as inoculum. Additionally, isolation of the leishmania can be obtained together with an increase in their density (180 times) as observed by growth kinetics, within a shorter time. These results justify the use of this low-cost technique for the isolation and investigation of the behavior and multiplication of Leishmania both in vertebrates and invertebrates, besides offering means of obtaining antigens, whether whole antigens (leishmanias) or the soluble antigens produced by the parasites which may be useful for the production of new diagnostic kits.
Resumo:
BACKGROUND: The quantitation of serum HBeAg is not commonly used to monitor viral response to therapy in chronic hepatitis B. METHODS: In this study, 21 patients receiving varying therapies were followed and their viral response monitored by concomitant viral load and HBeAg quantitation in order to study the meaning and the kinetics of both parameters. RESULTS: It was possible to distinguish between three different patterns of viral response. The first was characterized by a simultaneous decrease in serum HBV DNA and HBeAg. The second pattern was characterized by a decrease in serum HBeAg but persistent detection of HBV DNA. The third pattern was characterized by undetectable HBV DNA with persistent HBeAg positivity, which points to a non-response (Pattern III-B) except when HBeAg levels showed a slow but steady drop, characterizing a "slow responder" patient (Pattern III-A). CONCLUSIONS: The first pattern is compatible with a viral response. A long-term HBeAg seropositivity with a slow and persistent decrease (Pattern III-A) is also compatible with a viral response and calls for a prolongation of anti-viral treatment.
Resumo:
No dia-a-dia, os organismos vivos estão sujeitos a vários tipos de agressões de origem endógena e exógena. A produção endógena exagerada de contaminantes que ocorre nos processos metabólicos dos seres vivos está intimamente associada ao aparecimento e desenvolvimento de várias patologias. Por outro lado, e devido às atividades antropogénicas, muitos contaminantes de origem ambiental e alimentar entram por via exógena no organismo dos seres vivos provocando igualmente danos a nível celular. De modo a protegerem-se dos efeitos pejorativos provocados por estes compostos, os organismos vivos desenvolveram mecanismos complexos de defesa antioxidante. Este trabalho consistiu no estudo eletroquímico do dano oxidativo induzido por contaminantes (PAH (hidrocarbonetos aromáticos policíclicos), H2O2, NO• e HClO) e do efeito protetor, ao dano oxidativo, promovido por antioxidantes no material baseado no ADN recorrendo à utilização de um biossensor de bases púricas, adenina-EPC (elétrodo pasta de carbono) e dA20-EPC, utilizando a voltametria de onda quadrada (VOQ) como técnica de deteção. A aplicação da eletroquímica apresenta várias vantagens para a quantificação da capacidade antioxidante total (CAT) pois, permite a redução da quantidade de reagentes e amostra em análise, elimina a etapa de remoção de cor (a cor é um interferente nos métodos óticos) e não requer equipamentos dispendiosos. Foram seguidas diferentes abordagens para a construção dos biossensores. A primeira consistiu na construção de um adenina-EPC em três etapas: i) condicionamento do EPC, ii) eletrodeposição da adenina no EPC e iii) leitura do sinal eletroquímico. Assim, foram otimizados diversos parâmetros: concentração de adenina (150,0 mg/L), potencial de condicionamento (Ec) (+ 1,80 V), potencial de deposição (Ed) (+ 0,40 V), tempo de condicionamento (tc) (180 s) e tempo de deposição (td) (240 s). Foi aplicado o adenina-EPC no estudo do dano oxidativo provocado por PAH (benzo (g,h,i) perileno) e constatou-se que era necessário transformar o benzo (g,h,i) perileno num radical para se possível observar danos oxidativos induzidos no biossensor. A nova estratégia consistiu na construção de um dA20-EPC, através da adsorção física de uma gota de dA20 na superfície do EPC, com posterior secagem e leitura do sinal eletroquímico. Neste procedimento foi otimizada a concentração de dA20 (100,0 mg/L). O dano oxidativo provocado pelo H2O2, NO• e HClO foi estudado sobre o dA20-EPC e verificou-se que os três contaminantes induziam dano oxidativo no dA20-EPC. Confirmou-se a capacidade do ácido ascórbico (AA) em proteger o dA20-EPC do dano oxidativo induzido por H2O2 e NO•. O biossensor desenvolvido (dA20-EPC) foi aplicado na avaliação da CAT de diferentes amostras reais (café, sumo de laranja e água aromatizada de laranja) usando-se como contaminantes o H2O2 e NO•. Todas as amostras analisadas apresentaram ter capacidade antioxidante. Quando se usou o dA20-EPC na presença de H2O2, verificou-se que as amostras de café apresentam valores mais elevados de CAT (1130-1488 mg AAE/L) do que as amostras de bebidas (110 mg AAE/L em água aromatizada e 775 mg AAE/L em sumo). Os valores de CAT obtidos para amostras de sumo e água aromatizada na presença de NO• indicam que a amostra de sumo possui maior teor de CAT (526 mg AAE/L) conforme era esperado, do que a amostra de água aromatizada (172 mg AAE/L).
Resumo:
RESUMO: O desenvolvimento de serviços locais adequados deve ser baseado numa avaliação sistemática das necessidades e resultados obtidos nos cuidados a uma população de indivíduos identificados como apresentando uma doença mental na área de referenciação do serviço. Neste sentido foram utilizados os seguintes métodos: dados epidemiológicos acerca das necessidades locais e taxas de utilização de serviços a nível nacional e local, este último com base no case-register. Os diagnósticos de maior prevalência em ambulatório são as perturbações de humor e as perturbações neuróticas de stress ou somatoformes, com uma preponderância de doenças mentais comuns (depressão e ansiedade) em serviços de psiquiatria. Constatam-se baixas taxas de abandono da consulta (12%). A idade, a doença e a escolaridade estão correlacionados com o risco de drop-out, mas utilizada a regressão logística, a idade e a escolaridade perdem o seu significado estatístico. Encontram-se taxas reduzidas de drop-out dos indivíduos com psicose ou perturbações bipolares, em virtude da intervenção activa da equipa. Os custos de transporte, a distância ao local de consulta e o tempo de espera para a primeira consulta são barreiras no acesso aos cuidados a nível local. Os cuidadores não se sentem apoiados pela rede de suporte social e queixam-se sobretudo da acessibilidade, mas exibem elevadas taxas de satisfação com os serviços prestados. Decidiu-se apostar numa organização do serviço baseada na comunidade, com intervenções baseadas na evidência, dando prioridade ao doente mental grave e à qualidade dos cuidados.----------- ABSTRACT: The development of appropriate local services should be based on a systematic assessment of the needs and outcomes of the population of individuals identified as mentally ill within the service’s catchment area. A number of methods may be used as proxies in assessing local needs for services, such as service utilization rates found nationally and locally, by case-register. The most prevalent diagnoses in ambulatory care are mood disorders and neurotic, stress and somatoform disorders, with a majority of common mental disorders (depression and anxiety) in psychiatric services. Low dropout rates (12%) are found in ambulatory care. Age, disease and education are correlated with the risk of drop-out, but after using logistic regression, age and education lose their statistical significance. Low drop-out rates are found in individuals with psychosis or bipolar disorders, because the active intervention from the team. The costs of transportation, distance and the waiting time for the first consultation are barriers in access of care locally. Carers do not feel supported by the network of social support and complain primarily of accessibility, but exhibit high levels of satisfaction with the services provided. It was decided to invest in a service organization based in the community with evidence-based interventions, giving priority to severe mental illness and quality of care.
Resumo:
Oogram studies have been carried out on mice, hamsters, and Cebus morikeys experimentally infected with Schistosoma mansoni and treated with trichlorphone (0,0-dimethyl 1-hydroxy-2, 2, 2-trichloroethylphosphonate). In mice, despite a slight hepatic shift of schistosomes, all animais presented oogram changes when dosed, per os, at the schedules of 200, and 100 mg/kg/day × 7. In hamsters, antischistosomal activity could be detected only at toxic leveis. In monkeys, trichlorphone showed insignificant action even after oral administration of 30 mg/kg/day for 10 consecutive days. In 5 volunteers, a sharp drop in cholinesterase plasma level was observed 24 hours after a single oral dose of 7.5 mg/kg. However, cholinesterase levels returned to the initial values within a period of 11 to 27 days. Trichlorphone was then administered to 12 schistosome patients (7.5 mg/kg/day, every fort- night, × 5). One month after therapy, interruption of egg laying was observed in 6 patients. Late parasitological control showed that all treated patients continued to pass viable S. mansoni eggs with their stools.
Resumo:
BACKGROUND: Variations in emergency department admissions have been reported to happen as a result of major sports events. The work presented assessed changes in volume and urgency level of visits to a major Emergency Department in Lisbon during and after the city's football derby. MATERIAL AND METHODS: Volume of attendances and patient urgency level, according to the Manchester Triage System, were retrospectively analyzed for the 2008-2011 period. Data regarding 24-hour periods starting 45 minutes before kick-off was collected, along with data from similar periods on the corresponding weekdays in the previous years, to be used as controls. Data samples were organized according to time frame (during and after the match), urgency level, and paired accordingly. RESULTS: A total of 14 relevant periods (7 match and 7 non-match) were analyzed, corresponding to a total of 5861 admissions. During the match time frame, a 20.6% reduction (p = 0.06) in the total number of attendances was found when compared to non-match days. MTS urgency level sub-analysis only showed a statistically significant reduction (26.5%; p = 0.05) in less urgent admissions (triage levels green-blue). Compared to controls, post-match time frames showed a global increase in admissions (5.6%; p = 0.45), significant only when considering less urgent ones (18.9%; p = 0.05). DISCUSSION: A decrease in the total number of emergency department attendances occurred during the matches, followed by a subsequent increase in the following hours. These variations only reached significance among visits triaged green-blue. CONCLUSION: During major sports events an overall decrease in emergency department admissions seems to take place, especially due to a drop in visits associated with less severe conditions.
Resumo:
Dissertation to obtain the Doctoral degree in Physics Engineering
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics