1000 resultados para CGAR-EM (cromatografia gasosa de alta resolução - espectrometria de massas)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Novel and quantitative mass spectrometry methods for rapid and accurate enantiomeric excess determination are presented. These methodologies use electrospray ionization (ESI) and mass spectrometry (MS) to detect and analyze, via collision-induced dissociation (CID), mass-selected transition metal complexes that promote enantio especific interactions. The data from CID are conveniently treated by the kinetic method, a sensitive linear free energy method of treating mass spectrometric results. Four different variations of this methodology are described: single ratio method (S R), quotient ratio method (Q R), fixed ligand method (S Rfixed), and quotient ratio method with fixed ligand (Q Rfixed). These individual methods are compared and their main features discussed in detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work shows a method for the determination of chloramphenicol (CAP) antibiotic in milk, powder milk and honey. The solid phase extraction and liquid-liquid extraction were applied as a clean-up and pre-concentration strategies followed by LC-ESI/MS/MS analysis. The recovery was studied for different fortification levels from 0.05 to 1.00 µg L-1 in milk, showing values between 91 101% and RSD bellow 8.0%, while honey was spiked with a concentration of 0.20 µg kg-1 yelding a mean recovery of 83% and RSD of 6.5%. The quantification transition 321>152 showed a LOD of 0.52 ng kg-1 and LOQ of 1.85 ng kg-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces the basics of peptide mass spectra interpretation applied to proteomics and is directed to chemists, biochemists and biologists. The manuscript presents a well detailed protocol aiming to serve as a first choice guide for understanding peptide sequencing. The tutorial was elaborated based on both a thorough bibliographic revision and the author's experience. In order to prove the applicability of the proposed guide, spectra obtained on different instruments have been successfully interpreted by applying the presented rational.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The field of application of mass spectrometry (MS) has increased considerably due to the development of ionization techniques. Other factors that have stimulated the use of MS are the tandem mass spectrometry (MS/MS) and sequential mass spectrometry (MSn) techniques. However, the interpretation of the MS/MS and MSn data may lead to speculative conclusions. Thus, various quantum chemical methods have been applied for obtaining high quality thermochemical data in gas phase. In this review, we show some applications of computational quantum chemistry to understand the formation and fragmentation of gaseous ions of organic compounds in a MS analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure for determining of the isotope ratio 235U/238U in UF6 samples was established using a quadrupole mass spectrometer with ionization by electron impact. The following items were optimized in the spectrometer: the parameters in the ion source that provided the most intense peak, with good shape, for the most abundant isotope; the resolution that reduced the non linear effects and the number of analytical cycles that reduced the uncertainty in the results. The measurement process was characterized with respect to the effects of mass discrimination, linearity and memory effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review attempts to provide an updated overview of the Quick, Easy, Cheap, Effective, Ruged and Safe (QuEChERS) multiresidue extraction method, that involves initial extraction in acetonitrile, an extraction/partition step after the addition of salt, and a cleanup step utilizing dispersive solid phase extraction. QuEChERS method is nowadays the most applied extraction method for the determination of pesticide residues in food samples, providing acceptable recoveries for acidic, neutral and basic pesticides. Several applications for various food matrices (fruits, vegetables, cereals and others) in combination with chromatographic mass spectrometry analysis were presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In commemoration of the International Year of Chemistry this article presents the normalization and standardization of key terms used in mass spectrometry in Portuguese Language.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An absolute method is described via mass spectrometry (MS) for the structural assignment of isomers within the class of methylpiperidines. The method explores both the unimolecular and bimolecular gas phase behavior of structurally diagnostic fragment ions (SDFI). For the methylpiperidnes, the isomeric 2-methyl, 3-methyl and 4-methyl 2-azabutadienyl cations are found to function as SDFI. These fragment ions are expected to be formed from all members within the class, to be stable and to retain the structural information of the precursor molecule, and to not interconvert into one another. To characterize these SDFI, both the collision induced dissociation (CID) in argon and bimolecular ion/molecule chemistry with ethyl vinyl ether were compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solutions of [hydroxy(tosyloxy)iodo]benzene (HTIB or Koser's reagent) in acetonitrile were analyzed using high resolution electrospray ionization mass spectrometry (ESI-MS) and electrospray ionization tandem mass spectrometry (ESI-MS/MS) under different conditions. Several species were characterized in these analyses. Based on these data, mechanisms were proposed for the disproportionation of the iodine(III) compounds in iodine(V) and iodine(I) species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Erythrina verna is a medicinal plant used to calm agitation popularly known as mulungu. We purchased the barks of E. verna from a commercial producer and analyzed the alkaloid fraction of the bark by CG-MS and HRESI-MS. Five erythrinian alkaloids were identified: erysotrine, erythratidine, erythratidinone, epimer, and 11-hydroxieritratidinone. Here we report the compound 11-hydroxieritratidinone for the first time as a natural product.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of veterinary drug residues in foods of animal origin is an important issue because of the risk these compounds pose to human health in addition to their persistence and tendency to bioaccumulate. In recent years, significant progress has been made in the area and this review presents the state of the art in sample preparation procedures associated with chromatographic techniques coupled to mass spectrometry for multiresidue determination of veterinary drugs in food of animal origin at concentration levels suitable for the control of residues and contaminants in food.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Embora pareça existir um "flavor" característico de mel, a grande variedade de flores disponíveis para a abelha, possibilita uma grande diversidade de flavor e aroma, indicando a presença de vários componentes voláteis. Alguns destes dependem da fisiologia da abelha, dos procedimentos após a colheita e no mel de melato há também a interferência de insetos sugadores e das formigas. Várias substâncias voláteis já foram identificadas, sendo algumas características de determinados méis uniflorais. Com o objetivo de encontrar uma substância volátil característica do mel de melato, seis amostras deste tipo de mel e seis amostras de mel floral foram analisadas usando extração por arraste de gás hidrogênio e cromatografia a gás acoplada a espectrometria de massas. Ácido acético foi encontrado em quatro amostras de mel de melato e em uma amostra de mel floral porém, com menor abundância.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the new discoveries of oil and gas, the exploration of fields in various geological basins, imports of other oils and the development of alternative fuels, more and more research labs have evaluated and characterized new types of petroleum and derivatives. Therefore the investment in new techniques and equipment in the samples analysis to determine their physical and chemical properties, their composition, possible contaminants, especification of products, among others, have multiplied in last years, so development of techniques for rapid and efficient characterization is extremely important for a better economic recovery of oil. Based on this context, this work has two main objectives. The first one is to characterize the oil by thermogravimetry coupled with mass spectrometry (TG-MS), and correlate these results with from other types of characterizations data previously informed. The second is to use the technique to develop a methodology to obtain the curve of evaluation of hydrogen sulfide gas in oil. Thus, four samples were analyzed by TG-MS, and X-ray fluorescence spectrometry (XRF). TG results can be used to indicate the nature of oil, its tendency in coke formation, temperatures of distillation and cracking, and other features. It was observed in MS evaluations the behavior of oil main compounds with temperature, the points where the volatilized certain fractions and the evaluation gas analysis of sulfide hydrogen that is compared with the evaluation curve obtained by Petrobras with another methodology