933 resultados para twin defect
Resumo:
A practical machine-vision-based system is developed for fast detection of defects occurring on the surface of bottle caps. This system can be used to extract the circular region as the region of interests (ROI) from the surface of a bottle cap, and then use the circular region projection histogram (CRPH) as the matching features. We establish two dictionaries for the template and possible defect, respectively. Due to the requirements of high-speed production as well as detecting quality, a fast algorithm based on a sparse representation is proposed to speed up the searching. In the sparse representation, non-zero elements in the sparse factors indicate the defect's size and position. Experimental results in industrial trials show that the proposed method outperforms the orientation code method (OCM) and is able to produce promising results for detecting defects on the surface of bottle caps.
Resumo:
In this paper, a newly proposed machining method named “surface defect machining” (SDM) [Wear, 302, 2013 (1124-1135)] was explored for machining of nanocrystalline beta silicon carbide (3C-SiC) at 300K using MD simulation. The results were compared with isothermal high temperature machining at 1200K under the same machining parameters, emulating ductile mode micro laser assisted machining (µ-LAM) and with conventional cutting at 300 K. In the MD simulation, surface defects were generated on the top of the (010) surface of the 3C-SiC work piece prior to cutting, and the workpiece was then cut along the <100> direction using a single point diamond tool at a cutting speed of 10 m/sec. Cutting forces, sub-surface deformation layer depth, temperature in the shear zone, shear plane angle and friction coefficient were used to characterize the response of the workpiece. Simulation results showed that SDM provides a unique advantage of decreased shear plane angle which eases the shearing action. This in turn causes an increased value of average coefficient of friction in contrast to the isothermal cutting (carried at 1200 K) and normal cutting (carried at 300K). The increase of friction coefficient however was found to aid the cutting action of the tool due to an intermittent dropping in the cutting forces, lowering stresses on the cutting tool and reducing operational temperature. Analysis shows that the introduction of surface defects prior to conventional machining can be a viable choice for machining a wide range of ceramics, hard steels and composites compared to hot machining.
Resumo:
This paper is an extension to an idea coined during the 13th EUSPEN Conference (P6.23) named "surface defect machining" (SDM). The objective of this work was to demonstrate how a conventional CNC turret lathe can be used to obtain ultra high precision machined surface finish on hard steels without recourse to a sophisticated ultra precision machine tool. An AISI 4340 hard steel (69 HRC) workpiece was machined using a CBN cutting tool with and without SDM. Post-machining measurements by a Form Talysurf and a Scanning Electron Microscope (FEI Quanta 3D) revealed that SDM culminates to several key advantages (i) provides better quality of the machined surface integrity and offers (ii) lowering feed rate to 5μm/rev to obtain a machined surface roughness of 30 nm (optical quality).
Resumo:
Biodegradable polymers, such as PLA (Polylactide), come from renewable resources like corn starch and if disposed of correctly, degrade and become harmless to the ecosystem making them attractive alternatives to petroleum based polymers. PLA in particular is used in a variety of applications including medical devices, food packaging and waste disposal packaging. However, the industry faces challenges in melt processing of PLA due to its poor thermal stability which is influenced by processing temperatures and shearing.
Identification and control of suitable processing conditions is extremely challenging, usually relying on trial and error, and often sensitive to batch to batch variations. Off-line assessment in a lab environment can result in high scrap rates, long lead times and lengthy and expensive process development. Scrap rates are typically in the region of 25-30% for medical grade PLA costing between €2000-€5000/kg.
Additives are used to enhance material properties such as mechanical properties and may also have a therapeutic role in the case of bioresorbable medical devices, for example the release of calcium from orthopaedic implants such as fixation screws promotes healing. Additives can also reduce the costs involved as less of the polymer resin is required.
This study investigates the scope for monitoring, modelling and optimising processing conditions for twin screw extrusion of PLA and PLA w/calcium carbonate to achieve desired material properties. A DAQ system has been constructed to gather data from a bespoke measurement die comprising melt temperature; pressure drop along the length of the die; and UV-Vis spectral data which is shown to correlate to filler dispersion. Trials were carried out under a range of processing conditions using a Design of Experiments approach and samples were tested for mechanical properties, degradation rate and the release rate of calcium. Relationships between recorded process data and material characterisation results are explored.
Resumo:
This paper reports the realisation of precision surface finish (Ra 30 nm) on AISI 4340 steel using a conventional turret lathe by adapting and incorporating a surface defect machining (SDM) method [Wear, 302, 2013 (1124-1135)]. Conventional ways of machining materials are limited by the use of a critical feed rate, experimentally determined as 0.02 mm/rev, beyond which no appreciable improvement in the machined quality of the surface is obtained. However, in this research, the novel application of an SDM method was used to overcome this minimum feed rate limitation ultimately reducing it to 0.005 mm/rev and attaining an average machined surface roughness of 30 nm. From an application point of view, such a smooth finish is well within the values recommended in the ASTM standards for total knee joint prosthesis. Further analysis was done using SEM imaging, white light interferometry and numerical simulations to verify that adapting SDM method provides improved surface integrity by reducing the extent of side flow, microchips and weldments during the hard turning process.
Resumo:
A case of chronic myeloid leukaemia diagnosed as an incidental finding in a 32-year-old woman, pregnant with twins at 11 weeks gestation, is presented. Management of the patient was with leucapheresis and supportive care until spontaneous delivery of two morphologically normal infants (one male, one female) at 37 weeks gestation. Special considerations while employing leucapheresis in pregnant patients are discussed.
Resumo:
PURPOSE:
To estimate the heritability of peripheral refraction in Chinese children and adolescents.
METHODS:
The authors examined 72 monozygotic (MZ) twins and 48 dizygotic (DZ) twins aged 8 to 20 years from a population-based twin registry. Temporal and nasal peripheral refraction, each 40° from the visual axis, and axial refraction were measured using an autorefractor. Relative peripheral refractive error (RPRE) was defined as the peripheral refraction minus the axial refraction. Heritability was assessed by structural equation modeling after adjustment for age and sex.
RESULTS:
The mean and SD of temporal refraction (T(40)), nasal refraction (N(40)), RPRE-T(40), RPRE-N(40), and T(40)-N(40) asymmetry were -0.27 ± 2.0 D, 0.36 ± 2.19 D, 1.18 ± 1.39 D, 1.80 ± 1.69 D, and -0.62 ± 1.58 D, respectively. The intraclass correlations for T(40) refraction, N(40) refraction, RPRE-T(40), RPRE-N(40), and T(40)-N(40) asymmetry were 0.87, 0.83, 0.65, 0.74, and 0.58 for MZ pairs and 0.49, 0.42, 0.30, 0.41, and 0.32 for DZ pairs, respectively. A model with additive genetic and unique environmental effects was the most parsimonious, with heritability values estimated as 0.84, 0.76, 0.63, 0.70, and 0.55, respectively, for the peripheral refractive parameters.
CONCLUSIONS:
Additive genetic effects appear to explain most of the variance in peripheral refraction and relative peripheral refraction when adjusting for the effects of axial refraction.
Resumo:
PURPOSE:
This study investigated the heritability of lens thickness (LT) and relative lens thickness (LT/axial length, rLT) measured by Lenstar among Chinese children and adolescents in the Guangzhou Twin Eye study.
METHODS:
Twins aged 8 to 22 years were enrolled from the Guangzhou Twin Registry. A series of LT and axial length (AL) measurements using the Lenstar were taken for each twin. Zygosity was confirmed by genotyping in all same-sex twin pairs. Heritability was assessed by structural variance component genetic modeling, after adjustment for age and sex with the Mx program.
RESULTS:
Seven hundred sixty-eight twin pairs (482 monozygotic [MZ] and 286 dizygotic [DZ] twins) were available for data analysis. The mean (standard deviation) LT and rLT were 3.45 (0.18) mm and 0.142 (0.01), respectively. The intraclass correlation coefficients (ICCs) for LT were 0.90 for the MZ and 0.39 for the DZ twins; and those for rLT were 0.90 for the MZ and 0.40 for the DZ twins, respectively. The best-fitting model yielded 89.5% (95% CI: 87.8%-91.0%) of additive genetic effects and 10.5% (95% CI: 9.0%-12.2%) of unique environmental effects for LT, and 89.3% (95% CI: 89.2%-89.3%) of additive genetic effects and 10.7% (95% CI: 10.7%-11.4%) of unique environmental effects for rLT.
CONCLUSIONS:
This study confirms that the LT in young healthy subjects may be mainly affected by additive genetic factors. High heritability remains even when the data are corrected for the influence of AL with the use of rLT.
Resumo:
The development of neonatal intensive care has led to an increase in the prevalence of children with low birth weight and associated morbidity. The objectives of this study are to verify (1) The association between birth weight (BW) and neuromotor performance? (2) Is the neuromotor performance of twins within the normal range? (3) Are intra-pair similarities in neuromotor development of Monozygotic (MZ) and Disygotic (DZ) twins of unequal magnitude? The sample consisted of 191 children (78 MZ and 113 DZ), 8.9+3.1 years of age and with an average BW of 2246.3+485.4g. In addition to gestational characteristics, sports participation and Zurich Neuromotor Assessment (ZNA) were observed at childhood age. The statistical analysis was carried out with software SPSS 18.0, the STATA 10 and the ZNA performance scores. The level of significance was 0.05. For the neuromotor items high intra and inter-investigator reliabilities were obtained (0.793
Resumo:
Clinical history - A 4-year-old boy, born prematurely at 29 weeks (twin pregnancy), with periventricular leukomalacia and epilepsy underwent brain MRI. Neurological examination showed severe developmental retardation with axial hypotonia, spastic tetraparesis and convergent strabismus. Imaging findings - Cranial MRI revealed typical aspects of partial rhombencephalosynapsis with vermian hypoplasia, midline fusion of the cerebellar hemispheres and transversely oriented folia and fissures. There was also mild dilatation and dysmorphism of the ventricular system, the septum pellucidum was absent, the hippocampi were malrotated and had vertical orientation and additional finding of associated periventricular cystic leukomalacia. Discussion - Rhombencephalosynapsis (RS) is a rare congenital defect of the cerebellum classically characterised by vermian agenesis or hypogenesis, fusion of the hemispheres, and closely apposed or fused dentate nuclei. It is now considered to result from an absence of division of the cerebellar hemispheres, following an insult between the 28th and 44th day of gestation (i.e., before the formation of the vermis). Other features have also been described such as fusion of the thalami and cerebral peduncles, malrotated hippocampi, corpus callosum agenesis, hypoplastic chiasm, absence of the septum pellucidum, ventriculomegaly, agenesis of the posterior lobe of the pituitary and cortical malformations. Musculoskeletal, cardiovascular, urinary tract, and respiratory abnormalities have been reported. Typical symptoms consist of swallowing difficulties, delayed motor acquisitions, muscular hypotonia, spastic quadriparesis, cerebellar signs including dysarthria, gait ataxia, abnormal eye movements, and seizures and hydrocephalus. The major MRI signs consist of fused cerebellar hemispheres, with absent or hypoplastic vermis, narrow diamond-shaped fourth ventricle and fused dentate nuclei. In a minority of cases, partial RS has been identified by MRI, demonstrating the presence of the nodulus and the anterior vermis and absence of part of the posterior vermis with only partial fusion of the hemispheres in the inferior part. Other cerebellar malformations involving vermian agenesis or hypoplasia include the Dandy–Walker continuum, Joubert syndrome, tectocerebellar dysraphy or pontocerebellar hypoplasias, and are now easily distinguished from RS by both brain MRI and morphology.
Resumo:
During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.