993 resultados para rotary instrumentation
Resumo:
The electrocardiogram (ECG) is the simplest and most effective non-invasive method to assess the electrical activity of the heart and to obtain information on the heart rate (HR) and rhythm. Because information on the HR of very small reptiles (body mass <10 g) is still scarce in the literature, in the present work we describe a procedure for recording the ECG in non-anesthetized geckos (Hemidactylus mabouia, Moreau de Jonnès, 1818) under different conditions, namely manual restraint (MR), spontaneous tonic immobility (TI), and in the non-restrained condition (NR). In the gecko ECG, the P, QRS and T waves were clearly distinguishable. The HR was 2.83 ± 0.02 Hz under MR, which was significantly greater (p < 0.001) than the HR under the TI (1.65 ± 0.09 Hz) and NR (1.60 ± 0.10 Hz) conditions. Spontaneously beating isolated gecko hearts contracted at 0.84 ± 0.03 Hz. The in vitro beating rate was affected in a concentration-dependent fashion by adrenoceptor stimulation with noradrenaline, as well as by the muscarinic cholinergic agonist carbachol, which produced significant positive and negative chronotropic effects, respectively (p < 0.001). To our knowledge, this is the first report on the ECG morphology and HR values in geckos, particularly under TI. The methodology and instrumentation developed here are useful for non-invasive in vivo physiological and pharmacological studies in small reptiles without the need of physical restraint or anesthesia.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
High-temperature liquid chromatography (HTLC) is a technique that presents a series of advantages in liquid phase separations, such as: reduced analysis time, reduced pressure drop, reduced asymmetry factors, modified retentions, controlled selectivities, better efficiencies and improved detectivities, as well as permitting green chromatography. The practical limitations that relate to instrumentation and to stationary phase instability are being resolved and this technique is now ready to be applied for routine determinations.
Resumo:
The presence of vegetal impurities in sugarcane delivered to sugarmills as green and dry leaves is a problem not only because they are non-value materials to be processed along with sugarcane stalks, but also because they can rise the color of the clarified juice and, consequently, the color of the sugar produced, with a reduction of its quality for the market. Another problem is the mud volume sedimented in the clarifiers, which also can result in a larger recirculation and greater volume of filtrate juice, with higher losses of sucrose and utilization of the vacuum rotary filters. The objective of this work was to observe the effect of the presence of green and dry leaves on sugarcane juice clarification, related to a control treatment with the addition of fiber extracted from the stalks. The experiments were planned based on the addition of quantities of fibrous sources in order to formulate samples with absolute increase of 0.25 , 0.50 and 0.75 percentual points over the fiber content of the sugarcane stalks (control treatment). The juice clarification was conducted with a laboratory clarifier. The clarified juice color and the mud volume were evaluated. The presence of green leaves caused higher color and mud volume due to the extraction of non-sucrose components of the leaves. Soluble compounds of dry leaves were also extracted, though not detected by juice analysis. The addition of the fiber extracted from the stalks did not induce alterations in the clarification process.
Resumo:
Two kinds of roasting cocoa system: conventional batch method in electrical oven, and by microwaves, in a continuous microwave rotary applicator (2450MHz), were compared with respect to viscosity. Cocoa was roasted in whole beans and in nibs. The variable used in the microwave treatment was the power density applied to the whole beans (254,45 to 290,80 Wh/kg) and to the nibs (227,27 to 262,23 Wh/kg), with a constant holding time of 10 minutes. The variable used in the conventional roasting process was the roasting time of the beans (40 to 44 min) and the nibs (34 to 38 min), with constant temperature in the jacket of electric oven (150°C). Viscosity was measured in a Brookfield rheometer (mod RV-DVIII) at 40°C. In general, the plastic viscosity of the microwaved samples was lower than that of the conventional roasted samples. Also the nibs showed lower viscosities than the whole beans when roasted in the electric oven. The viscosity of the samples roasted in the microwave oven was lower in the whole beans than in the nibs. The product was sensorially evaluated by three experts in cocoa flavour, and it was shown that the flavour of the microwave roasted products was similar to that of the conventionally roasted products, with the advantage of a reduction in process time.
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
This paper presents a case report of a left mandibular second premolar with three canals and three different apical foramina. A 39-year-old male patient presented to our clinic with pain in the mandibular left second premolar. Initially, pain was caused by cold stimulus and later was spontaneously. The intraoral clinical examination revealed a fractured amalgam restoration with occlusal caries. Percussion and cold (Endo-Frost) tests were positive. The radiographic examination showed the presence of two roots. The probable diagnosis was an acute pulpitis. After access cavity, it was observed remaining roof of the pulp chamber and mild bleeding in the tooth lingual area, indicating the possible presence of a third canal. The endodontic treatment was completed in a single session using Root ZX apex locator and K3 NiTi rotary system with surgical diameter corresponding to a .02/45 file in the three canals and irrigation with 1% sodium hypochlorite. The canals were obtured with gutta-percha cones and Sealer 26 using the lateral condensation technique. After 1 year of follow-up, the tooth was asymptomatic and periapical repair was observed radiographically. Internal alterations should be considered during the endodontic treatment of mandibular second premolars. The correct diagnosis of these alterations by the analysis of preoperative radiographs can help the location of two or more canals, thereby avoiding root therapy failure.
Resumo:
This article describes and discusses a method to determine root curvature radius by using cone-beam computed tomography (CBCT). The severity of root canal curvature is essential to select instrument and instrumentation technique. The diagnosis and planning of root canal treatment have traditionally been made based on periapical radiography. However, the higher accuracy of CBCT images to identify anatomic and pathologic alterations compared to panoramic and periapical radiographs has been shown to reduce the incidence of false-negative results. In high-resolution images, the measurement of root curvature radius can be obtained by circumcenter. Based on 3 mathematical points determined with the working tools of Planimp® software, it is possible to calculate root curvature radius in both apical and coronal directions. The CBCT-aided method for determination of root curvature radius presented in this article is easy to perform, reproducible and allows a more reliable and predictable endodontic planning, which reflects directly on a more efficacious preparation of curved root canals.
Resumo:
This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (µm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 ± 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 ± 48.31), followed by EndoFlare instruments (68.20 ± 42.44), Gattes Glidden drills (68.90 ± 42.46) and ProTaper files (77.40 ± 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.
Resumo:
The aim of this study was to assess qualitatively, by means of SEM images, the cleaning of the dentin walls of root canals after chemical-surgical preparation using Endo-PTC cream with 0.5% and 1% sodium hypochlorite and different final irrigating solutions. Seventy-two single-rooted human teeth were divided into eight groups and prepared using Endo-PTC cream with sodium hypochlorite (NaOCl) at different concentrations, and irrigated with NaOCl at different concentrations. Final irrigation was performed with either EDTA-T or EDTA-C. The best results were obtained with Group 1, followed by Groups 5, 2, 7, 8, 3, 6 and 4. We can conclude that the use of 0.5% NaOCl during instrumentation and final flush of the root canals was more efficient in cleaning than was 1% sodium hypochlorite. EDTA-T was more efficient in removing smear layer than EDTA-C, and the cervical third presented better cleaning of the root canal walls than did the middle third, which showed cleaner dentin walls than the apical third.
Resumo:
PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predicts keratoconus-like behavior and its evolution based on material properties of the corneal tissue. METHODS: Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity. RESULTS: The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea. CONCLUSIONS: This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.