991 resultados para positive pressure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In humans, intra-abdominal pressure (IAP) is elevated during many everyday activities. This experiment aimed to investigate the extent to which increased IAP-without concurrent activity of the abdominal or back extensor muscles-produces an extensor torque. With subjects positioned in side lying on a swivel table with its axis at L3, moments about this vertebral level were measured when IAP was transiently increased by electrical stimulation of the diaphragm via the phrenic nerve. There was no electromyographic activity in abdominal and back extensor muscles. When IAP was increased artificially to similar to 15% of the maximum IAP amplitude that could be generated voluntarily with the trunk positioned in flexion, a trunk extensor moment (similar to6 Nm) was recorded. The size of the effect was proportional to the increase in pressure. The extensor moment was consistent with that predicted from a model based on measurements of abdominal cross-sectional area and IAP moment arm. When IAP was momentarily increased while the trunk was flexed passively at a constant velocity, the external torque required to maintain the velocity was increased. These results provide the first in vivo data of the amplitude of extensor moment that is produced by increased IAP. Although the net effect of this extensor torque in functional tasks would be dependent on the muscles used to increase the IAP and their associated flexion torque, the data do provide evidence that IAP contributes, at least in part, to spinal stability. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND. Sentinel lymph node (SLN) mapping and biopsy is emerging as an alternative to axillary lymph node dissection (ALND) in determining the lymph node status of patients with early-stage breast carcinoma. The hypothesis of the technique is that the SLN is the first lymph node in the regional lymphatic basin that drains the primary tumor. Non-SLN (NSLN) metastasis in the axilla is unlikely if the axillary SLN shows no tumor involvement, and, thus, further axillary interference may be avoided. However, the optimal treatment of the axilla in which an SLN metastasis is found requires ongoing evaluation. The objectives of this study were to evaluate the predictors for NSLN metastasis in the presence of a tumor-involved axillary SLN and to examine the treatment implications for patients with early-stage breast carcinoma. METHODS. Between June 1998 and May 2000, 167 patients participated in the pilot study of SLN mapping and biopsy at Westmead Hospital. SLNs were identified successfully and biopsied in 140 axillae. All study patients also underwent ALND. The incidence of NSLN metastasis in the 51 patients with a SLN metastasis was correlated with clinical and pathologic characteristics. RESULTS. Of 51 patients with a positive SLN, 24 patients (47%) had NSLN metastases. The primary tumor size was the only significant predictor for NSLN involvement. NSLN metastasis occurred in 25% of patients (95% confidence interval [95%CI], 10-47%) with a primary tumor size less than or equal to 20 mm and in 67% of patients (95%CI, 46-83%) with a primary tumor size > 20 mm (P = 0.005). The size of the SLN metastasis was not associated significantly with NSLN involvement. Three of 7 patients (43%) with an SLN micrometastasis (< 1 mm) had NSLN involvement compared with 38 of 44 patients (48%) with an SLN macrometastasis (greater than or equal to 1 mm). CONCLUSIONS. The current study did not identify a subgroup of SLN positive patients in whom the incidence of NSLN involvement was low enough to warrant no further axillary interference. At present, a full axillary dissection should be performed in patients with a positive SLN. (C) 2001 American Cancer Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We perform a quantum-mechanical analysis of the pendular cavity, using the positive-P representation, showing that the quantum state of the moving mirror, a macroscopic object, has noticeable effects on the dynamics. This system has previously been proposed as a candidate for the quantum-limited measurement of small displacements of the mirror due to radiation pressure, for the production of states with entanglement between the mirror and the field, and even for superposition states of the mirror. However, when we treat the oscillating mirror quantum mechanically, we find that it always oscillates, has no stationary steady state, and exhibits uncertainties in position and momentum which are typically larger than the mean values. This means that previous linearized fluctuation analyses which have been used to predict these highly quantum states are of limited use. We find that the achievable accuracy in measurement is fat, worse than the standard quantum limit due to thermal noise, which, for typical experimental parameters, is overwhelming even at 2 mK

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The divided visual field technique was used to investigate the pattern of brain asymmetry in the perception of positive/approach and negative/withdrawal facial expressions. A total of 80 undergraduate students (65 female, 15 male) were distributed in five experimental groups in order to investigate separately the perception of expressions of happiness, surprise, fear, sadness, and the neutral face. In each trial a target and a distractor expression were presented simultaneously in a computer screen for 150 ms and participants had to determine the side (left or right) on which the target expression was presented. Results indicated that expressions of happiness and fear were identified faster when presented in the left visual field, suggesting an advantage of the right hemisphere in the perception of these expressions. Fewer judgement errors and faster reaction times were also observed for the matching condition in which emotional faces were presented in the left visual field and neutral faces in the right visual field. Other results indicated that positive expressions (happiness and surprise) were perceived faster and more accurately than negative ones (sadness and fear). Main results tend to support the right hemisphere hypothesis, which predicts a better performance of the right hemisphere to perceive emotions, as opposed to the approach-withdrawal hypothesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate whether arterial baroreceptors mediate the training-induced blood pressure fall and resting bradycardia in hypertensive (SHR) and normotensive rats (WKY). Male SHR and WKY rats, submitted to sino-aortic denervation (SAD) or sham surgery (SHAM group), were allocated to training (T; 55% of maximal exercise capacity) or sedentary (S) protocols for 3 months. Rats were instrumented with arterial and venous catheters for haemodynamic measurements at rest (power spectral analysis) and baroreceptor testing. Kidney and skeletal muscles were processed for morphometric analysis of arterioles. Elevated mean arterial pressure (MAP) and heart rate (HR) in SHAM SHRS were accompanied by increased sympathetic variability and arteriolar wall/lumen ratio [+3.4-fold on low-frequency (LF) power and +70%, respectively, versus WKYS, P < 0.05]. Training caused significant HR (similar to 9% in WKY and SHR) and MAP reductions (-8% in the SHR), simultaneously with improvement of baroreceptor reflex control of HR (SHR and WKY), LF reduction (with a positive correlation between LF power and MAP levels in the SHR) and normalization of wall/lumen ratio of the skeletal muscle arterioles (SHR only). In contrast, SAD increased pressure variability in both strains of rats, causing reductions in MAP (-13%) and arteriolar wall/lumen ratio (-35%) only in the SHRS. Training effects were completely blocked by SAD in both strains; in addition, after SAD the resting MAP and HR and the wall/lumen ratio of skeletal muscle arterioles were higher in SHRT versus SHRS and similar to those of SHAM SHRS. The lack of training-induced effects in the chronic absence of baroreceptor inputs strongly suggests that baroreceptor signalling plays a decisive role in driving beneficial training-induced cardiovascular adjustments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selection of the optimal positive end-expiratory pressure (PEEP) to avoid ventilator-induced lung injury in patients under mechanical ventilation is still a matter of debate. Many methods are available, but none is considered the gold standard. In the previous issue of Critical Care, Zhao and colleagues applied a method based on electrical impedance tomography to help select the PEEP that minimized ventilation inhomogeneities. Though promising when alveolar collapse and overdistension are present, this method might be misleading in patients with normal lungs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of prolonged recruitment manoeuvre (PRM) were compared with sustained inflation (SI) in paraquat-induced mild acute lung injury (ALI) in rats. Twenty-four hours after ALI induction, rats were anesthetized and mechanically ventilated with VT = 6 ml/kg and positive end-expiratory pressure (PEEP) = 5 cmH(2)O for 1 h. SI was performed with an instantaneous pressure increase of 40 cmH(2)O that was sustained for 40 s, while PRM was done by a step-wise increase in positive inspiratory pressure (PIP) of 15-20-25 cmH(2)O above a PEEP of 15 cm H(2)O (maximal PIP = 40 cmH(2)O), with interposed periods of PIP = 10 cmH(2)O above a PEEP = 15 cmH(2)O. Lung static elastance and the amount of alveolar collapse were more reduced with PRM than SI, yielding improved oxygenation. Additionally, tumour necrosis factor-alpha, interleukin-6, interferon-gamma, and type III procollagen mRNA expressions in lung tissue and lung epithelial cell apoptosis decreased more in PRM. In conclusion, PRM improved lung function, with less damage to alveolar epithelium, resulting in reduced pulmonary injury. (C) 2009 Elsevier BLV. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neonatal screening for congenital adrenal hyperplasia (CAH) is useful in diagnosing salt wasting form (SW). However, there are difficulties in interpreting positive results in asymptomatic newborns. The main objective is to analyze genotyping as a confirmatory test in children with neonatal positive results. Patients comprised 23 CAH children and 19 asymptomatic infants with persistently elevated 17-hydroxyprogesterone (17OHP) levels. CYP21A2 gene was sequenced and genotypes were grouped according to the enzymatic activity of the less severe allele: A1 null, A2 < 2%, B 3-7%, C > 20%. Twenty-one children with neonatal symptoms and/or 17OHP levels > 80 ng/ml carried A genotypes, except two virilized girls (17OHP < 50 ng/ml) without CAH genotypes. Patients carrying SW genotypes (A1, A2) and low serum sodium levels presented with neonatal 17OHP > 200 ng/ml. Three asymptomatic boys carried simple virilizing genotypes (A2 and B): in two, the symptoms began at 18 months; another two asymptomatic boys had nonclassical genotypes (C). The remaining 14 patients did not present CAH genotypes, and their 17OHP levels were normalized by 14 months of age. Molecular analysis is useful as a confirmatory test of CAH, mainly in boys. It can predict clinical course, identify false-positives and help distinguish between clinical forms of CAH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. It is not known if the adjustment of antihypertensive therapy based on home blood pressure monitoring (HBPM) can improve blood pressure (BP) control among haemodialysis patients. Methods. This is an open randomized clinical trial. Hypertensive patients on haemodialysis were randomized to have the antihypertensive therapy adjusted based on predialysis BP measurements or HBPM. Before and after 6 months of follow-up, patients were submitted to ambulatory blood pressure monitoring (ABPM) for 24 h, HBPM during 1 week and echocardiogram. Results. A total of 34 and 31 patients completed the study in the HBPM and predialysis BP groups, respectively. At the end of study, the systolic (SBP) and diastolic (DBP) blood pressure during the interdialytic period measured by ABPM were significantly lower in the HBPM group in relation to the predialysis BP group (mean 24-h BP: 135 +/- 12 mmHg/76 +/- 7 mmHg versus 147 +/- 15 mmHg/79 +/- 8 mmHg; P < 0.05). In the HBPM analysis, the HBPM group showed a significant reduction only in SBP compared to the predialysis BP group (weekly mean: 144 +/- 21 mmHg versus 154 +/- 22 mmHg; P < 0.05). There were no differences between the HBPM and predialysis BP groups in relation to the left ventricular mass index at the end of the study (108 +/- 35 g/m(2) versus 110 +/- 33 g/m(2); P > 0.05). Conclusions. Decision making based on HBPM among haemodialysis patients has led to a better BP control during the interdialytic period in comparison with predialysis BP measurements. HBPM may be a useful adjuvant instrument for blood pressure control among haemodialysis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to determine the correlation between ductus venosus (DV) Doppler velocimetry and fetal cardiac troponin T (cTnT). Study design: Between March 2007 and March 2008, 89 high-risk pregnancies were prospectively studied. All patients delivered by cesarean section and the Doppler exams were performed on the same day. Multiple regression included the following variables: maternial age, parity, hypertension, diabetes, gestational age at delivery, umbilical artery (UA) S/D ratio, diagnosis of absent or reversed end-diastolic flow velocity (AREDV) in the UA, middle cerebral artery (MCA) pulsatility index (131), and DV pulsatility index for veins (PIV). Immediately after delivery, UA blood samples were obtained for the measurement of pH and cTnT levels. Statistical analysis included the Kruskal-Wallis test and multiple regressions. Results: The results showed a cTnT concentration at birth >0.05 ng/ml in nine (81.8%) of AREDV cases, a proportion significantly higher than that observed in normal UA S/D ratio and UA S/D ratio >p95 with positive diastolic blood flow (7.7 and 23.1%, respectively, p < 0.001). A positive correlation Was found between abnormal DV-PIV and elevated cTnT levels in the UA. Multiple regression identified DV-PIV and a diagnosis of AREDV as independent factors associated with abnormal fetal cTnT levels (p < 0.0001, F(2.86) = 63.5, R = 0.7722). Conclusion: DV-PIV was significantly correlated with fetal cTnT concentrations at delivery. AREDV and abnormal DV flow represent severe cardiac compromise, with increased systemic venous pressure, and a rise in right ventricular afterload, demonstrated by myocardial damage and elevated fetal cTnT. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To present a novel algorithm for estimating recruitable alveolar collapse and hyperdistension based on electrical impedance tomography (EIT) during a decremental positive end-expiratory pressure (PEEP) titration. Technical note with illustrative case reports. Respiratory intensive care unit. Patients with acute respiratory distress syndrome. Lung recruitment and PEEP titration maneuver. Simultaneous acquisition of EIT and X-ray computerized tomography (CT) data. We found good agreement (in terms of amount and spatial location) between the collapse estimated by EIT and CT for all levels of PEEP. The optimal PEEP values detected by EIT for patients 1 and 2 (keeping lung collapse < 10%) were 19 and 17 cmH(2)O, respectively. Although pointing to the same non-dependent lung regions, EIT estimates of hyperdistension represent the functional deterioration of lung units, instead of their anatomical changes, and could not be compared directly with static CT estimates for hyperinflation. We described an EIT-based method for estimating recruitable alveolar collapse at the bedside, pointing out its regional distribution. Additionally, we proposed a measure of lung hyperdistension based on regional lung mechanics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. We describe a series of 10 children with intracranial hypertension complicating fulminant hepatic failure submitted to intracranial pressure (ICP) monitoring for intensive care an transplantation management. Patients and methods. Information from pediatrics patients acute liver failure admitted to our hospital was collected in a standard protocol form. We analyzed data from 10 patients, medium age 5.2 years old. In this period we studied aspects as ICP transducer used, number of days with ICP monitoring and complications of ICP monitoring. Results. Hepatitis A was diagnosed in five patients and hepatitis B in two cases. The initial ICP were 2 to 24 mmHg in transducer Seven patients died, four due to intracranial hypertension, included the patient operated for subdural hematoma, and three with transplantation failure. Only, a case of hematoma was verified. Conclusions. The application of ICP monitoring allows intensive care for aggressive ICP management. It can be used in children without adaptations. [REV NEUROL 2009: 48: 134-6]