931 resultados para high voltage


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a compact electric discharge plasma source for controlling NOX emission in diesel engine exhaust. An automobile ignition coil was used to generate the high voltage pulse using flyback topology. This design is aimed at retrofitting the existing catalytic converters with pulse assisted cleaning technique. In this paper we bring out a relative comparison of discharge plasma and plasma-adsorbent process at different gas flow rates. Activated alumina was used as adsorbent. The main emphasis is laid on the development of a compact pulse source from a DC supply for the removal of NOX from the filtered diesel engine exhaust.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Higher level of inversion is achieved with a less number of switches in the proposed scheme. The scheme proposes a five-level inverter for an open-end winding induction motor which uses only two DC-link rectifiers of voltage rating of Vdc/4, a neutral-point clamped (NPC) three-level inverter and a two-level inverter. Even though the two-level inverter is connected to the high-voltage side, it is always in square-wave operation. Since the two-level inverter is not switching in a pulse width modulated fashion and the magnitude of switching transient is only half compared to the convention three-level NPC inverter, the switching losses and electromagnetic interference is not so high. The scheme is experimentally verified on a 2.5 kW induction machine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An attempt has been made to study the effect of time and test procedure on the behaviour of partial discharge (PD) pulses causing failure of oil-pressboard system under power frequency voltages using circular disc shaped samples and uniform field electrodes. Weibull statistics have been used to handle the large amount of PD data. The PD phenomena has been found to be stress and time dependent. On the basis of stress level, three different regions are identified and in one of the regions, the rate of deterioration of the sample is at a maximum. The work presents some interesting features of Weibull parameters as related to the condition of insulation studied in addition to its usual PD characteristics

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Capacitive-resistive transients in extended media are discussed in tenns of electric field quantities. Obviously, in rhese problems, the contribution of the magnetlc field to the electric field is deemed negligible. For a simple lllusfratlve example, the field solution is compared with the circuit-theoretical resuit for the voltage and current. An algorithm for solving such transients in space and time doman with the help of a Laplace solver is presented. Any other Laplace solver can also be used far this purpose. Its applicability is demonstrated with three examples, one of which is chosen to have a circuit-theoretical solution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper deals with the long-term accelerated weathering of 11 kV polymeric insulators for 25000 h. Polymeric insulators were continuously subjected to accelerated weathering in a specially designed multistress-aging chamber under UV radiation, temperature and electric stress. Chemical, physical and electrical changes due to degradation have been assessed using various techniques. Some of the interesting results observed indicate that there is a significant reduction in the content of low molecular weight molecules, hydrophobicity was dynamic in nature and there is a significant increase in the surface roughness and oxidation levels with respect to the duration of the weathering.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Treeing in polyethylene based nanocomposite samples as well as unfilled polyethylene samples were studied using 50Hz ac voltage. The tree inception voltage was observed for different types of samples. The tree initiation time as well as the tree growth patterns at a fixed ac voltage have also been studied. The results show that there is an improvement in tree inception voltage with nano filler loading in polyethylene. Different tree growth patterns for both the unfilled polyethylene and the polyethylene nanocomposites have been observed. A slower tree growth was observed in polyethylene nanocomposites. The partial discharge characteristics of unfilled and nano filled polyethylene samples during the electrical tree growth period was also studied. Decrease in PD magnitude as well as in the number of pd pulses with electrical tree growth duration in polyethylene nanocomposites has also been observed. The possible reasons for the improvement in electrical tree growth and PD resistance with the addition of nano fillers are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effect of various parameters on the velocity of the induced jet produced by a dielectric barrier discharge (DBD) plasma was studied experimentally. The glow discharge was created at atmospheric conditions by using a high voltage RF power supply. Flow visualization and photographic studies of the plasma were performed. The parametric investigation of the characteristics of the plasma show that the width of the plasma in the uniform glow discharge regime was an indication of the velocity induced under stagnant conditions. It was observed that the spanwise overlap of the two electrodes, dielectric thickness, voltage and frequency of the applied voltage are the major parameters that govern the velocity and the extent of plasma in the streamwise direction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experimental study and optimization of Plasma Ac- tuators for Flow control in subsonic regime PRADEEP MOISE, JOSEPH MATHEW, KARTIK VENKATRAMAN, JOY THOMAS, Indian Institute of Science, FLOW CONTROL TEAM | The induced jet produced by a dielectric barrier discharge (DBD) setup is capable of preventing °ow separation on airfoils at high angles of attack. The ef-fect of various parameters on the velocity of this induced jet was studied experimentally. The glow discharge was created at atmospheric con-ditions by using a high voltage RF power supply. Flow visualization,photographic studies of the plasma, and hot-wire measurements on the induced jet were performed. The parametric investigation of the charac- teristics of the plasma show that the width of the plasma in the uniform glow discharge regime was an indication of the velocity induced. It was observed that the spanwise and streamwise overlap of the two electrodes,dielectric thickness, voltage and frequency of the applied voltage are the major parameters that govern the velocity and the extent of plasma.e®ect of the optimized con¯guration on the performance characteristics of an airfoil was studied experimentally.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A cascaded system of electrical discharges (non-thermal plasma) and adsorption process was investigated for the removal of oxides of Nitrogen (NOx) and total hydrocarbons (THC) from an actual diesel engine exhaust. The non-thermal plasma and adsorption processes were separately studied first and then the cascaded process was studied. In this study, different types of adsorbents were used. The NOx removal efficiency was higher with plasma-associated adsorption (cascaded) process compared to the individual processes and the removal efficiency was found almost invariant in time. When associated by plasma, among the adsorbents studied, activated charcoal and MS-13X were more effective for NOx and THC removal respectively. The experiments were conducted at no load and at 50% load conditions. The plasma reactor was kept at room temperature throughout the experiment, while the temperature of the adsorbent reactor was varied. A relative comparison of adsorbents was discussed at the end.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The discharge plasma-chemical hybrid process for NOinfinity removal from the flue gas emissions is an extremely effective and economical approach in comparison with the conventional selective catalytic reduction system. In this paper we bring out a relative comparison of several discharge plasma reactors from the point of NO removal efficiency. The reactors were either energized by ac or by repetitive pulses. Ferroelectric pellets were used to study the effect of pellet assisted discharges on gas cleaning. Diesel engine exhaust, at different loads; is used to approximately simulate the flue gas composition. Investigations were carried out at room temperature with respect to the variation of reaction products against the discharge power. Main emphasis is laid on the oxidation of NO to NO2, without reducing NOx concentration (i.e., minimum reaction byproducts), with least power consumption. The produced NO2 will be totally converted to N-2 and Na-2 SO4 using Na-2 SO3. The ac packed-bed reactor and pelletless pulsed corona reactor showed better performance, with minimum reaction products for a given power, when the NO concentration was low (similar to 100 ppm). When the engine load exceeds 50% (NO > 300 ppm) there was not much decrease in NO reduction and more or less all the reactors performed equally. The total operating cost of the plasma-chemical hybrid system becomes $4010/ton of NO, which is 1/3-1/5 of the conventional selective catalytic process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Insulator becomes wet partially or completely, and the pollution layer on it becomes conductive, when collecting pollutants for an extended period during dew, light rain, mist, fog or snow melting. Heavy rain is a complicated factor that it may wash away the pollution layer without initiating other stages of breakdown or it may bridge the gaps between sheds to promote flashover. The insulator with a conducting pollution layer being energized, can cause a surface leakage current to flow (also temperature-rise). As the surface conductivity is non-uniform, the conducting pollution layer becomes broken by dry bands (at spots of high current density), interrupting the flow of leakage current. Voltage across insulator gets concentrated across dry bands, and causes high electric stress and breakdown (dry band arcing). If the resistance of the insulator surface is sufficiently low, the dry band arcs can be propagated to bridge the terminals causing flashover. The present paper concerns the evaluation of the temperature distribution along the surface of an energized artificially polluted insulator string.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experimental investigations into the effect of temperature on conversion of NO in the presence of hydrocarbons (ethylene, acetylene and n-hexane) are presented. An AC energized dielectric barrier discharge reactor was used as the plasma reactor. The experiments were carried out at different temperatures up to 200 degreesC. The discharge powers were measured at all the temperatures. The discharge power was found to increase with temperature. NO conversion in the presence of ethylene and n-hexane was better than that of acetylene at all temperatures. The addition of acetylene at room temperature showed no better conversion of NO compared to no additive case. While at higher temperatures, it could enhance the conversion of NO. A slight enhancement in NO and NOx removal was observed in the presence of water vapor. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, an approach to enhance the Extra High Voltage (EHV) Transmission system distance protection is presented. The scheme depends on the apparent impedance seen by the distance relay during the disturbance. In a distance relay,the impedance seen at the relay location is calculated from the fundamental frequency component of the voltage and current signals. Support Vector Machines (SVMs) are a new learning-byexample are employed in discriminating zone settings (Zone-1,Zone-2 and Zone-3) using the signals to be used by the relay.Studies on 265-bus system, an equivalent of practical Indian Western grid are presented for illustrating the proposed scheme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transmission of bulk power at high voltages over very long distances has become very imperative. At present, throughout the globe, this task has been mostly performed by overhead transmission lines. The dual task of mechanically supporting and electrically isolating the live phase conductors from the support tower is performed by string insulators. Whether in clean condition or under polluted conditions, the electrical stress distribution along the insulators governs the possible flashover, which is quite detrimental to the system. However, a reliable data on stress distribution in commonly employed string insulators are rather scarce. Considering this, the present work has made an attempt to study accurately, the field distribution in 220 kV strings for six different types of porcelain/ceramic insulators (Normal and Antifog discs) used for high voltage transmission. The surface charge simulation method is employed for the required field computation. Voltage and electric stress distribution is deduced and compared across different types of discs. A comparison on normalised surface resistance, which is an indicator for the stress concentration under polluted condition, is also attempted.