892 resultados para fault handling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Publicación bilingüe

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, one of the most important concerns for many companies is to maintain the operation of their systems without sudden equipment break down. Because of this, new techniques for fault detection and location in mechanical systems subject to dynamic loads have been developed. This paper studies of the influence of the decay rate in the design of state observers using LMI for fault detection in mechanical systems. This influence is analyzed by the performance index proposed by Huh and Stein for the condition of a state observer. An example is presented to illustrate the methodology discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper. © 2010 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose an accurate method for fault location in underground distribution systems by means of an Optimum-Path Forest (OPF) classifier. We applied the Time Domains Reflectometry method for signal acquisition, which was further analyzed by OPF and several other well known pattern recognition techniques. The results indicated that OPF and Support Vector Machines outperformed Artificial Neural Networks classifier. However, OPF has been much more efficient than all classifiers for training, and the second one faster for classification. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a fast and an accurate method for fault diagnosis in power transformers by means of Optimum-Path Forest (OPF) classifier. Since we applied Dissolved Gas Analysis (DGA), the samples have been labeled by IEEE/IEC standard, which was further analyzed by OPF and several other well known supervised pattern recognition techniques. The experiments have showed that OPF can achieve high recognition rates with low computational cost. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays the method based on demodulation by envelope finds wide application in industry as a technique for evaluation of bearings and other components in rotating machinery. In recent years the application of Wavelets for fault diagnosis in machinery has also obtained good development. This article demonstrates the effectiveness of the combined application of Wavelets and envelope technique (also known as HFRT High-Frequency Resonance Technique) to remove background noise from signals collected from defect bearings and identification of the characteristic frequencies of defects. A comparison of the results obtained with the isolated application of only one method against the combined technique is performed showing the increased capacity in detection of faults in rolling bearings. © (2013) Trans Tech Publications, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL (xsuperconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level. © 2002-2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between 75% and 90% of the waste produced by health-care providers no risk or is "general" health-care waste, comparable to domestic waste. The remaining 10-25% of health-care waste is regarded as hazardous due to one or more of the following characteristics: it may contain infectious agents, sharps, toxic or hazardous chemicals or it may be radioactive. Infectious health-care waste, particularly sharps, has been responsible for most of the accidents reported in the literature. In this work the preliminary risks analysis (PRA) technique was used to evaluate practices in the handling of infectious health-care waste. Currently the PRA technique is being used to identify and to evaluate the potential for hazard of the activities, products, and services from facilities and industries. The system studied was a health-care establishment which has handling practices for infectious waste. Thirty-six procedures related to segregation, containment, internal collection, and storage operation were analyzed. The severity of the consequences of the failure (risk) that can occur from careless management of infectious health-care waste was classified into four categories: negligible, marginal, critical, and catastrophic. The results obtained in this study showed that events with critics consequences, about 80%, may occur during the implementation of the containment operation, suggesting the need to prioritize this operation. As a result of the methodology applied in this work, a flowchart the risk series was also obtained. In the flowchart the events that can occur as a consequence of a improper handling of infectious health-care waste, which can cause critical risks such as injuries from sharps and contamination (infection) from pathogenic microorganisms, are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO:O manuseio de materiais está ainda presente nos setores industriais e é associado a lesões na coluna lombar e membros superiores. A inserção de alças em caixas industriais é uma forma de reduzir os riscos relacionados à tarefa, porém a posição e a angulação das alças, que são fatores importantes para o conforto e segurança durante o manuseio, são ainda pouco investigadas objetivamente.OBJETIVOS:Comparar o manuseio de uma caixa comercial e de protótipos com alças e avaliar seus efeitos na postura de membros superiores, atividade elétrica muscular e percepção de agradabilidade em diferentes empunhaduras durante manuseio entre diferentes alturas.MÉTODO:Trinta e sete voluntários saudáveis avaliaram as alças dos protótipos que possibilitavam mudança nas posições (superior e inferior) e angulações (0°, 15° e 30º). Os movimentos dos punhos, cotovelos e ombros foram avaliados por meio da eletrogoniometria e inclinometria. A atividade elétrica muscular dos extensores do punho, bíceps braquial e porção superior do trapézio foi avaliada por um eletromiógrafo portátil. Os registros de movimento e atividade elétrica muscular foram sincronizados. Aspectos subjetivos de agradabilidade foram avaliados por meio de uma escala visual analógica.RESULTADOS E CONCLUSÕES:Os protótipos com alças inclinadas em 30° apresentaram as melhores avaliações de agradabilidade, posturas mais neutras de punho, menores níveis de atividade eletromiográfica do trapézio superior e menores ângulos de elevação dos braços. Os diferentes métodos de medida se mostraram complementares para a avaliação dos membros superiores durante as tarefas de manuseio.