544 resultados para eletro-fenton
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this study the incidence of moths and beetles was examined from feces samples of bats that use different foraging behaviors. Twenty sites around the Fazenda Intervales, a Field Research Station located in São Paulo State, in southeastern Brazil were sampled. Feces were collected from bats caught in mist nets, Turtle Traps or hand nets and, in one case, from beneath a roost. Feces samples were taken from six species of bats: Micronycteris megalotis (Gray, 1842), Mimon bennettii (Gray, 1838), Furipterus horrens (F. Cuvier, 1828), Myotis riparius Handley, 1960, Myotis ruber (E. Geoffroy, 1806) and Histiotus velalus (I. Geoffroy, 1824). To record and describe the frequencies dominating bat echolocation calls, an Anabat II bat detector coupled with an Anabat ZCA interfaces and DOS laptop computers were used. The data show that Furipterus horrens feeds extensively on moths, as predicted from the features of its echolocation calls. Gleaning bats, whose echolocation calls are much less conspicuous to moths take a wide range of insect (and other) prey.
Resumo:
Assessing the composition of an area's bat fauna is typically accomplished by using captures or by monitoring echolocation calls with bat detectors. The two methods may not provide the same data regarding species composition. Mist nets and harp traps may be biased towards sampling low flying species, and bat detectors biased towards detecting high intensity echolocators. A comparison of the bat fauna of Fazenda Intervales, southeastern Brazil, as revealed by mist nets and harp trap captures, checking roosts and by monitoring echolocation calls of flying bats illustrates this point. A total of 17 species of bats was sampled. Fourteen bat species were captured and the echolocation calls of 12 species were recorded, three of them not revealed by mist nets or harp traps. The different sampling methods provided different pictures of the bat fauna. Phyllostomid bats dominated the catches in mist nets, but in the field their echolocation calls were never detected. No single sampling approach provided a complete assessment of the bat fauna in the study area. In general, bats producing low intensity echolocation calls, such as phyllostomids, are more easily assessed by netting, and bats producing high intensity echolocation calls are better surveyed by bat detectors. The results demonstrate that a combined and varied approach to sampling is required for a complete assessment of the bat fauna of an area.
Resumo:
Avaliou-se o efeito da eletroacupuntura (EA) sobre os aspectos macroscópicos e microscópicos em 36 coelhos que tiveram o tendão calcanear comum seccionado e que, após 30 dias, receberam enxerto de peritônio bovino conservado em solução saturada de sal. Após a cirurgia, os animais foram distribuídos em três grupos de igual número: os do grupo E10 foram estimulados pela EA do segundo ao 11º dia de pós-operatório, os do grupo E20 do 11º ao 31º dia de pós-operatório e os do grupo C não foram estimulados. Posteriormente, os animais foram redistribuídos em três subgrupos de igual número, os quais foram observados no pós-operatório por 11, 31 e 91 dias. Nos coelhos do E10 e E20, ocorreu diminuição de aderência da área enxertada aos tecidos circunvizinhos. Aos 31 dias de pós-operatório, observou-se nos do E10 tecido conjuntivo. Verificou-se intensa neovascularização no local enxertado em todos os animais que receberam estímulo pela EA. Nos coelhos do E10, aos 91 dias, verificou-se intensa quantidade de tecido conjuntivo, com fibras colágenas organizadas e paralelas ao eixo do tendão. O estímulo pela EA na fase precoce do pós-operatório estimulou a maturação cicatricial com mínima reação inflamatória.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The efficiency of different methods for the decontamination of glassware used for the analysis of dissolved organic carbon (DOC) was tested using reported procedures as well as new ones proposed in this work. A Fenton solution bath (1.0 mmol L-1 Fe2+ and 100 mmol L-1 H2O2) for 1 h or for 30 min employing UV irradiation showed to combine simplicity, low cost and high efficiency. Using the optimized cleaning procedure, the DOC for stored UV-irradiated ultrapure water reached concentrations below the limit of detection (0.19 mu mol C L-1). Filtered (0.7 mu m) rain samples maintained the DOC integrity for at least 7 days when stored at 4 degrees C. The volatile organic carbon (VOC) fraction in the rain samples collected at two sites in São Paulo state (Brazil) ranged from 0% to 56% of their total DOC content. Although these high-VOC concentrations may be derived from the large use of ethanol fuel in Brazil, our results showed that when using the high-temperature catalytic oxidation technique, it is essential to measure DOC rather than non-purgeble organic carbon to estimate organic carbon, since rainwater composition can be quite variable, both geographically and temporally. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The photo-Fenton process using potassium ferrioxalate as a mediator in the photodegradation reaction of organochloride compounds in an aqueous medium was investigated. The influence of parameters such as hydrogen peroxide and ferrioxalate concentrations and initial pH, was evaluated using dichloroacetic acid (DCA) as a model compound under black-light lamp irradiation. An upflow annular photoreactor, operating in a single pass or recirculating mode was used during photodegradation experiments with artificial light. The extent of the release of chloride ions was used to evaluate the photodegradation reaction. The optimum pH range observed was 2.5-2.8. The efficiency of DCA dechlorination increased with increasing concentrations of H2O2 and potassium ferrioxalate, reaching a plateau after the addition of 6 and 1.5 mmol/L of those reagents, respectively. The total organic carbon (TOC) content in DCA and 2,4-dichlorophenol (DCP) solutions was compared with the chloride released after photodegradation. The influence of natural solar light intensity, measured at 365 nm, was evaluated for the dechlorination of DCA on typical summer's days showing a linear dependency. The photodegradation of DCA using black-light lamp and solar irradiation was compared.
Resumo:
This review focuses on the heterogeneous photocatalytic treatment of organic dyes in air and water. Representative studies spanning approximately three decades are included in this review. These studies have mostly used titanium dioxide (TiO2) as the inorganic semiconductor photocatalyst of choice for decolorizing and decomposing the organic dye to mineralized products. Other semiconductors such as ZnO, CdS, WO3, and Fe2O3 have also been used, albeit to a much smaller extent. The topics covered include historical aspects, dark adsorption of the dye on the semiconductor surface and its role in the subsequent photoreaction, semiconductor preparation details, photoreactor configurations, photooxidation kinetics/mechanisms and comparison with other Advanced Oxidation Processes (e.g., UV/H2O2, ozonation, UV/O3, Fenton and photo-Fenton reactions), visible light-induced dye decomposition by sensitization mechanism, reaction intermediates and toxicity issues, and real-world process scenarios. © 2008 Elsevier B.V. All rights reserved.
Resumo:
Incluye Bibliografía
Resumo:
This work studied the degradation of dipyrone, via electrochemical processes and via electro-Fenton reaction using a 4% CeO2/C gas diffusion electrode (GDE) prepared via modified polymeric precursor method. This material was used to electrochemically generate H2O2 through oxygen reduction. The mean crystallite sizes estimated by the Scherrer equation for 4% CeO2/C were 4 nm for CeO2-x (0 4 4) and 5 nm for CeO2 (1 1 1) while using transmission electron microscopy (TEM) the mean nanoparticle size was 5.4 nm. X-ray photoelectron spectroscopy (XPS) measurements revealed nearly equal concentrations of Ce(III) and Ce(IV) species on carbon, which contained high oxygenated acid species like CO and OCO. Electrochemical degradation using Vulcan XC 72R carbon showed that the dipyrone was not removed during the two hour electrolysis in all applied potentials by electro-degradation. Besides, when the Fenton process was employed the degradation was much similar when using cerium catalysts but the mineralization reaches just to 50% at -1.1 V. However, using the CeO2/C GDE, in 20 min all of the dipyrone was degraded with 26% mineralization at -1.3 V and when the Fenton process was employed, all of the dipyrone was removed after 5 min with 57% mineralization at -1.1 V. Relative to Vulcan XC72R, ceria acts as an oxygen buffer leading to an increase in the local oxygen concentration, facilitating H2O2 formation and consequently improving the dipyrone degradation © 2013 Elsevier B.V. All rights reserved.
Resumo:
A comparative study using different mass proportions of WO3/C (1%, 5%, 10% and 15%) for H2O2 electrogeneration and subsequent phenol degradation was performed. To include the influence of the carbon substrate and the preparation methods, all synthesis parameters were evaluated. The WO3/C materials were prepared by a modified polymeric precursor method (PPM) and the sol-gel method (SGM) on Vulcan XC 72R and Printex L6 carbon supports, verifying the most efficient metal/carbon proportion. The materials were physically characterized by X-ray diffraction (XRD) and by X-ray photoelectron spectroscopy (XPS) techniques. The XRD and the XPS techniques identified just one phase containing WO3 and elevated oxygen concentration on carbon with the presence of WO3. The oxygen reduction reaction (ORR), studied by the rotating ring-disk electrode technique, showed that WO3/C material with the lowest tungsten content (1% WO3/C), supported on Vulcan XC 72R and prepared by SGM, was the most promising electrocatalyst for H2O2 electrogeneration. This material was then analyzed using a gas diffusion electrode (GDE) and 585mgL-1 of H2O2 was produced in acid media. This GDE was employed as a working electrode in an electrochemical cell to promote phenol degradation by an advanced oxidative process. The most efficient method applied was the photo-electro-Fenton; this method allowed for 65% degradation and 11% mineralization of phenol during a 2-h period. Following 12h of exhaustive electrolysis using the photo-electro-Fenton method, the total degradation of phenol was observed after 4h and the mineralization of phenol approached 75% after 12h. © 2013 Elsevier B.V.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)