889 resultados para Validation of analytical methodology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Age-related changes in lumbar vertebral microarchitecture are evaluated, as assessed by trabecular bone score (TBS), in a cohort of 5,942 French women. The magnitude of TBS decline between 45 and 85 years of age is piecewise linear in the spine and averaged 14.5 %. TBS decline rate increases after 65 years by 50 %. INTRODUCTION: This study aimed to evaluate age-related changes in lumbar vertebral microarchitecture, as assessed by TBS, in a cohort of French women aged 45-85 years. METHODS: An all-comers cohort of French Caucasian women was selected from two clinical centers. Data obtained from these centers were cross-calibrated for TBS and bone mineral density (BMD). BMD and TBS were evaluated at L1-L4 and for all lumbar vertebrae combined using GE-Lunar Prodigy densitometer images. Weight, height, and body mass index (BMI) also were determined. To validate our all-comers cohort, the BMD normative data of our cohort and French Prodigy data were compared. RESULTS: A cohort of 5,942 French women aged 45 to 85 years was created. Dual-energy X-ray absorptiometry normative data obtained for BMD from this cohort were not significantly different from French prodigy normative data (p = 0.15). TBS values at L1-L4 were poorly correlated with BMI (r = -0.17) and weight (r = -0.14) and not correlated with height. TBS values obtained for all lumbar vertebra combined (L1, L2, L3, L4) decreased with age. The magnitude of TBS decline at L1-L4 between 45 and 85 years of age was piecewise linear in the spine and averaged 14.5 %, but this rate increased after 65 years by 50 %. Similar results were obtained for other region of interest in the lumbar spine. As opposed to BMD, TBS was not affected by spinal osteoarthrosis. CONCLUSION: The age-specific reference curve for TBS generated here could therefore be used to help clinicians to improve osteoporosis patient management and to monitor microarchitectural changes related to treatment or other diseases in routine clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two trends which presently exist in relation to the concept of Paleontology are analyzed, pointing out some of the aspects which negative influence. Various reflections are made based on examples of some of the principal points of paleontological method, such as the influence of a punctual sampling, the meaning of size-frequency distribution and subjectivity in the identification of fossils. Topics which have a marked repercussion in diverse aspects of Paleontology are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last five years, Deep Brain Stimulation (DBS) has become the most popular and effective surgical technique for the treatent of Parkinson's disease (PD). The Subthalamic Nucleus (STN) is the usual target involved when applying DBS. Unfortunately, the STN is in general not visible in common medical imaging modalities. Therefore, atlas-based segmentation is commonly considered to locate it in the images. In this paper, we propose a scheme that allows both, to perform a comparison between different registration algorithms and to evaluate their ability to locate the STN automatically. Using this scheme we can evaluate the expert variability against the error of the algorithms and we demonstrate that automatic STN location is possible and as accurate as the methods currently used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computational network analysis provides new methods to analyze the brain's structural organization based on diffusion imaging tractography data. Networks are characterized by global and local metrics that have recently given promising insights into diagnosis and the further understanding of psychiatric and neurologic disorders. Most of these metrics are based on the idea that information in a network flows along the shortest paths. In contrast to this notion, communicability is a broader measure of connectivity which assumes that information could flow along all possible paths between two nodes. In our work, the features of network metrics related to communicability were explored for the first time in the healthy structural brain network. In addition, the sensitivity of such metrics was analysed using simulated lesions to specific nodes and network connections. Results showed advantages of communicability over conventional metrics in detecting densely connected nodes as well as subsets of nodes vulnerable to lesions. In addition, communicability centrality was shown to be widely affected by the lesions and the changes were negatively correlated with the distance from lesion site. In summary, our analysis suggests that communicability metrics that may provide an insight into the integrative properties of the structural brain network and that these metrics may be useful for the analysis of brain networks in the presence of lesions. Nevertheless, the interpretation of communicability is not straightforward; hence these metrics should be used as a supplement to the more standard connectivity network metrics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Rotational thromboelastometry (ROTEM) is a whole blood point-of-test used to assess the patient's coagulation status. Three of the available ROTEM tests are EXTEM, INTEM and HEPTEM. In the latter, heparinase added to the INTEM reagent inactivates heparin to reveal residual heparin effect. Performing ROTEM analysis during cardiopulmonary bypass (CPB) might allow the anaesthesiologist to anticipate the need for blood products. OBJECTIVE: The goal of this study was to validate ROTEM analysis in the presence of very high heparin concentrations during CPB. DESIGN: Prospective, observational trial. SETTING: Single University Hospital. PARTICIPANTS: Twenty patients undergoing coronary artery bypass grafting. MAIN OUTCOME MEASURE: ROTEM analysis was performed before heparin administration (T0), 10 min after heparin (T1), at the end of CPB (T2) and 10 min after protamine (T3). The following tests were performed: EXTEM, INTEM, and HEPTEM. Heparin concentrations were measured at T1 and at the end of bypass (T2). RESULTS: At T1, EXTEM differed from baseline for coagulation time: +26.7 s (18.4 to 34.9, P < 0.0001), α: -3° (1.0 to 5.4, P = 0.006) and A10: -4.4 mm (2.3 to 6.5, P = 0.0004). INTEM at T0 was different from HEPTEM at T1 for coagulation time: + 47 s (34.3 to 59.6, P >0.0001), A10: -2.3 mm (0.5 to 4.0, P = 0.01) and α -2° (1.0 to 3.0; P = 0.0007). At T2, all parameters in EXTEM and HEPTEM related to fibrin-platelet interaction deteriorated significantly compared to T1. At T3, EXTEM and INTEM were comparable to EXTEM and HEPTEM at T2. CONCLUSION: HEPTEM and EXTEM measurements are valid in the presence of very high heparin concentrations and can be performed before protamine administration in patients undergoing cardiac surgery with CPB. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01455454.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Guilbert ER, Morin D, Guilbert AC, Gagnon H, Robitaille J, Richardson M. International Journal of Nursing Practice 2011; 17: 315-321 Task-shifting in the delivery of hormonal contraceptive methods: Validation of a questionnaire and preliminary results In order to palliate the access problem to effective contraceptive methods in Quebec, Canada, as well as to legitimate nurses' practices in family planning, a collaborative agreement was developed that allow nurses, in conjunction with pharmacists, to give hormonal contraceptives to healthy women of reproductive age for a 6 month period. Training in hormonal contraception was offered to targeted nurses before they could begin this practice. A questionnaire, based on Rogers's theory of diffusion of innovations, was elaborated and validated to specifically evaluate this phenomenon. Preliminary results show that the translation of training into practice might be suboptimal. The validated questionnaire can now be used to fully understand the set of factors influencing this new practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The DRAGON score predicts functional outcome in the hyperacute phase of intravenous thrombolysis treatment of ischemic stroke patients. We aimed to validate the score in a large multicenter cohort in anterior and posterior circulation. METHODS: Prospectively collected data of consecutive ischemic stroke patients who received intravenous thrombolysis in 12 stroke centers were merged (n=5471). We excluded patients lacking data necessary to calculate the score and patients with missing 3-month modified Rankin scale scores. The final cohort comprised 4519 eligible patients. We assessed the performance of the DRAGON score with area under the receiver operating characteristic curve in the whole cohort for both good (modified Rankin scale score, 0-2) and miserable (modified Rankin scale score, 5-6) outcomes. RESULTS: Area under the receiver operating characteristic curve was 0.84 (0.82-0.85) for miserable outcome and 0.82 (0.80-0.83) for good outcome. Proportions of patients with good outcome were 96%, 93%, 78%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 2%, 4%, 89%, and 97% for 0 to 1, 2, 3, 8, and 9 to 10 points, respectively. When tested separately for anterior and posterior circulation, there was no difference in performance (P=0.55); areas under the receiver operating characteristic curve were 0.84 (0.83-0.86) and 0.82 (0.78-0.87), respectively. No sex-related difference in performance was observed (P=0.25). CONCLUSIONS: The DRAGON score showed very good performance in the large merged cohort in both anterior and posterior circulation strokes. The DRAGON score provides rapid estimation of patient prognosis and supports clinical decision-making in the hyperacute phase of stroke care (eg, when invasive add-on strategies are considered).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Standardized instruments are needed to assess the activity of eosinophilic esophagitis (EoE) and to provide end points for clinical trials and observational studies. We aimed to develop and validate a patient-reported outcome (PRO) instrument and score, based on items that could account for variations in patient assessments of disease severity. We also evaluated relationships between patient assessment of disease severity and EoE-associated endoscopic, histologic, and laboratory findings. METHODS: We collected information from 186 patients with EoE in Switzerland and the United States (69.4% male; median age, 43 y) via surveys (n = 135), focus groups (n = 27), and semistructured interviews (n = 24). Items were generated for the instruments to assess biologic activity based on physician input. Linear regression was used to quantify the extent to which variations in patient-reported disease characteristics could account for variations in patient assessment of EoE severity. The PRO instrument was used prospectively in 153 adult patients with EoE (72.5% male; median age, 38 y), and validated in an independent group of 120 patients with EoE (60.8% male; median age, 40.5 y). RESULTS: Seven PRO factors that are used to assess characteristics of dysphagia, behavioral adaptations to living with dysphagia, and pain while swallowing accounted for 67% of the variation in patient assessment of disease severity. Based on statistical consideration and patient input, a 7-day recall period was selected. Highly active EoE, based on endoscopic and histologic findings, was associated with an increase in patient-assessed disease severity. In the validation study, the mean difference between patient assessment of EoE severity (range, 0-10) and PRO score (range, 0-8.52) was 0.15. CONCLUSIONS: We developed and validated an EoE scoring system based on 7 PRO items that assess symptoms over a 7-day recall period. Clinicaltrials.gov number: NCT00939263.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A patient's chest pain raises concern for the possibility of coronary heart disease (CHD). An easy to use clinical prediction rule has been derived from the TOPIC study in Lausanne. Our objective is to validate this clinical score for ruling out CHD in primary care patients with chest pain. Methods: This secondary analysis used data collected from a oneyear follow-up cohort study attending 76 GPs in Germany. Patients attending their GP with chest pain were questioned on their age, gender, duration of chest pain (1-60 min), sternal pain location, pain increases with exertion, absence of tenderness point at palpation, cardiovascular risks factors, and personal history of cardiovascular disease. Area under the curve (ROC), sensitivity and specificity of the Lausanne CHD score were calculated for patients with full data. Results: 1190 patients were included. Full data was available for 509 patients (42.8%). Missing data was not related to having CHD (p = 0.397) or having a cardiovascular risk factor (p = 0.275). 76 (14.9%) were diagnosed with a CHD. Prevalence of CHD were respectively of 68/344 (19.8%), 2/62 (3.2%), 6/103 (5.8%) in the high, intermediate and low risk category. ROC was of 72.9 (CI95% 66.8; 78.9). Ruling out patients with low risk has a sensitivity of 92.1% (CI95% 83.0; 96.7) and a specificity of 22.4% (CI95% 18.6%; 26.7%). Conclusion: The Lausanne CHD score shows reasonably good sensitivity and can be used to rule out coronary events in patients with chest pain. Patients at risk of CHD for other rarer reasons should nevertheless also be investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Chest pain can be caused by various conditions, with life-threatening cardiac disease being of greatest concern. Prediction scores to rule out coronary artery disease have been developed for use in emergency settings. We developed and validated a simple prediction rule for use in primary care. METHODS: We conducted a cross-sectional diagnostic study in 74 primary care practices in Germany. Primary care physicians recruited all consecutive patients who presented with chest pain (n = 1249) and recorded symptoms and findings for each patient (derivation cohort). An independent expert panel reviewed follow-up data obtained at six weeks and six months on symptoms, investigations, hospital admissions and medications to determine the presence or absence of coronary artery disease. Adjusted odds ratios of relevant variables were used to develop a prediction rule. We calculated measures of diagnostic accuracy for different cut-off values for the prediction scores using data derived from another prospective primary care study (validation cohort). RESULTS: The prediction rule contained five determinants (age/sex, known vascular disease, patient assumes pain is of cardiac origin, pain is worse during exercise, and pain is not reproducible by palpation), with the score ranging from 0 to 5 points. The area under the curve (receiver operating characteristic curve) was 0.87 (95% confidence interval [CI] 0.83-0.91) for the derivation cohort and 0.90 (95% CI 0.87-0.93) for the validation cohort. The best overall discrimination was with a cut-off value of 3 (positive result 3-5 points; negative result <or= 2 points), which had a sensitivity of 87.1% (95% CI 79.9%-94.2%) and a specificity of 80.8% (77.6%-83.9%). INTERPRETATION: The prediction rule for coronary artery disease in primary care proved to be robust in the validation cohort. It can help to rule out coronary artery disease in patients presenting with chest pain in primary care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, lacking validated tools. The Spinal Function Sort (SFS) was only validated in English. We aimed to translate, adapt and validate the French (SFS-F) and German (SFS-G) versions of the SFS. Methods Three hundred and forty-four patients, experiencing various back complaints, were recruited in a French (n = 87) and a German-speaking (n = 257) center. Construct validity was estimated via correlations with SF-36 physical and mental scales, pain intensity and hospital anxiety and depression scales (HADS). Scale homogeneities were assessed by Cronbach's α. Test-retest reliability was assessed on 65 additional patients using intraclass correlation (IC). Results For the French and German translations, respectively, α were 0.98 and 0.98; IC 0.98 (95% CI: [0.97; 1.00]) and 0.94 (0.90; 0.98). Correlations with physical functioning were 0.63 (0.48; 0.74) and 0.67 (0.59; 0.73); with physical summary 0.60 (0.44; 0.72) and 0.52 (0.43; 0.61); with pain -0.33 (-0.51; -0.13) and -0.51 (-0.60; -0.42); with mental health -0.08 (-0.29; 0.14) and 0.25 (0.13; 0.36); with mental summary 0.01 (-0.21; 0.23) and 0.28 (0.16; 0.39); with depression -0.26 (-0.45; -0.05) and -0.42 (-0.52; -0.32); with anxiety -0.17 (-0.37; -0.04) and -0.45 (-0.54; -0.35). Conclusions Reliability was excellent for both languages. Convergent validity was good with SF-36 physical scales, moderate with VAS pain. Divergent validity was low with SF-36 mental scales in both translated versions and with HADS for the SFS-F (moderate in SFS-G). Both versions seem to be valid and reliable for evaluating perceived functional capacity in patients with back complaints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

While the incidence of sleep disorders is continuously increasing in western societies, there is a clear demand for technologies to asses sleep-related parameters in ambulatory scenarios. The present study introduces a novel concept of accurate sensor to measure RR intervals via the analysis of photo-plethysmographic signals recorded at the wrist. In a cohort of 26 subjects undergoing full night polysomnography, the wrist device provided RR interval estimates in agreement with RR intervals as measured from standard electrocardiographic time series. The study showed an overall agreement between both approaches of 0.05 ± 18 ms. The novel wrist sensor opens the door towards a new generation of comfortable and easy-to-use sleep monitors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La aplicabilidad, repetibilidad y capacidad de diferentes métodos de análisis para discriminar muestras de aceites con diferentes grados de oxidación fueron evaluadas mediante aceites recogidos en procesos de fritura en continuo en varias empresas españolas. El objetivo de este trabajo fue encontrar métodos complementarios a la determinación del índice de acidez para el control de calidad rutinario de los aceites de fritura empleados en estas empresas. La optimización de la determinación de la constante dieléctrica conllevó una clara mejora de la variabilidad. No obstante, excepto en el caso del índice del ATB, el resto de métodos ensayados mostraron una menor variabilidad. La determinación del índice del ATB fue descartada ya que su sensibilidad fue insuficiente para discriminar entre aceites con diferente grado de oxidación. Los diferentes parámetros de alteración determinados en los aceites de fritura mostraron correlaciones significativas entre el índice de acidez y varios parámetros de oxidación diferentes, como la constante dieléctrica, el índice de p-anisidina, la absorción al ultravioleta y el contenido en polímeros de los triacilgliceroles. El índice de acidez solo evalúa la alteración hidrolítica, por lo que estos parámetros aportan información complementaria al evaluar la alteración termooxidativa.