870 resultados para Standard IEEE 1451


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A list of 681 UBVRI secondary standard stars for CCD photometry is presented. Visual magnitude ranges from 9.7 to 19.4, and the B-V colour index varies from 1.15 to 1.97. The stars are grouped into 11 different fields, each of them is generally observable in a single CCD frame. The stars are located near Landolt UBVRI equatorial standards, accessible to telescopes in both hemispheres, and mainly within the 5 - 8 hours range of right ascension. Photometry, equatorial coordinates and finding charts are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Segmenting ultrasound images is a challenging problemwhere standard unsupervised segmentation methods such asthe well-known Chan-Vese method fail. We propose in thispaper an efficient segmentation method for this class ofimages. Our proposed algorithm is based on asemi-supervised approach (user labels) and the use ofimage patches as data features. We also consider thePearson distance between patches, which has been shown tobe robust w.r.t speckle noise present in ultrasoundimages. Our results on phantom and clinical data show avery high similarity agreement with the ground truthprovided by a medical expert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The standard data fusion methods may not be satisfactory to merge a high-resolution panchromatic image and a low-resolution multispectral image because they can distort the spectral characteristics of the multispectral data. The authors developed a technique, based on multiresolution wavelet decomposition, for the merging and data fusion of such images. The method presented consists of adding the wavelet coefficients of the high-resolution image to the multispectral (low-resolution) data. They have studied several possibilities concluding that the method which produces the best results consists in adding the high order coefficients of the wavelet transform of the panchromatic image to the intensity component (defined as L=(R+G+B)/3) of the multispectral image. The method is, thus, an improvement on standard intensity-hue-saturation (IHS or LHS) mergers. They used the ¿a trous¿ algorithm which allows the use of a dyadic wavelet to merge nondyadic data in a simple and efficient scheme. They used the method to merge SPOT and LANDSATTM images. The technique presented is clearly better than the IHS and LHS mergers in preserving both spectral and spatial information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[eng] ISO standard 9001 is one of a set of management tools that libraries have adopted in recent years. This article focuses on libraries in higher education institutions that have received ISO certification of their quality management systems (ISO standard 9001:2000). We examine their reasons for seeking certification and the advantages and difficulties they have encountered in applying this ISO standard. Finally, we consider the future prospects of ISO standard 9001 in university libraries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cilengitide is a selective αvβ3 and αvβ5 integrin inhibitor. Data from phase 2 trials suggest that it has antitumour activity as a single agent in recurrent glioblastoma and in combination with standard temozolomide chemoradiotherapy in newly diagnosed glioblastoma (particularly in tumours with methylated MGMT promoter). We aimed to assess cilengitide combined with temozolomide chemoradiotherapy in patients with newly diagnosed glioblastoma with methylated MGMT promoter. METHODS: In this multicentre, open-label, phase 3 study, we investigated the efficacy of cilengitide in patients from 146 study sites in 25 countries. Eligible patients (newly diagnosed, histologically proven supratentorial glioblastoma, methylated MGMT promoter, and age ≥18 years) were stratified for prognostic Radiation Therapy Oncology Group recursive partitioning analysis class and geographic region and centrally randomised in a 1:1 ratio with interactive voice response system to receive temozolomide chemoradiotherapy with cilengitide 2000 mg intravenously twice weekly (cilengitide group) or temozolomide chemoradiotherapy alone (control group). Patients and investigators were unmasked to treatment allocation. Maintenance temozolomide was given for up to six cycles, and cilengitide was given for up to 18 months or until disease progression or unacceptable toxic effects. The primary endpoint was overall survival. We analysed survival outcomes by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00689221. FINDINGS: Overall, 3471 patients were screened. Of these patients, 3060 had tumour MGMT status tested; 926 patients had a methylated MGMT promoter, and 545 were randomly assigned to the cilengitide (n=272) or control groups (n=273) between Oct 31, 2008, and May 12, 2011. Median overall survival was 26·3 months (95% CI 23·8-28·8) in the cilengitide group and 26·3 months (23·9-34·7) in the control group (hazard ratio 1·02, 95% CI 0·81-1·29, p=0·86). None of the predefined clinical subgroups showed a benefit from cilengitide. We noted no overall additional toxic effects with cilengitide treatment. The most commonly reported adverse events of grade 3 or worse in the safety population were lymphopenia (31 [12%] in the cilengitide group vs 26 [10%] in the control group), thrombocytopenia (28 [11%] vs 46 [18%]), neutropenia (19 [7%] vs 24 [9%]), leucopenia (18 [7%] vs 20 [8%]), and convulsion (14 [5%] vs 15 [6%]). INTERPRETATION: The addition of cilengitide to temozolomide chemoradiotherapy did not improve outcomes; cilengitide will not be further developed as an anticancer drug. Nevertheless, integrins remain a potential treatment target for glioblastoma. FUNDING: Merck KGaA, Darmstadt, Germany.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To quantify the relationship between bone marrow (BM) response to radiation and radiation dose by using (18)F-labeled fluorodeoxyglucose positron emission tomography [(18)F]FDG-PET standard uptake values (SUV) and to correlate these findings with hematological toxicity (HT) in cervical cancer (CC) patients treated with chemoradiation therapy (CRT). METHODS AND MATERIALS: Seventeen women with a diagnosis of CC were treated with standard doses of CRT. All patients underwent pre- and post-therapy [(18)F]FDG-PET/computed tomography (CT). Hemograms were obtained before and during treatment and 3 months after treatment and at last follow-up. Pelvic bone was autosegmented as total bone marrow (BMTOT). Active bone marrow (BMACT) was contoured based on SUV greater than the mean SUV of BMTOT. The volumes (V) of each region receiving 10, 20, 30, and 40 Gy (V10, V20, V30, and V40, respectively) were calculated. Metabolic volume histograms and voxel SUV map response graphs were created. Relative changes in SUV before and after therapy were calculated by separating SUV voxels into radiation therapy dose ranges of 5 Gy. The relationships among SUV decrease, radiation dose, and HT were investigated using multiple regression models. RESULTS: Mean relative pre-post-therapy SUV reductions in BMTOT and BMACT were 27% and 38%, respectively. BMACT volume was significantly reduced after treatment (from 651.5 to 231.6 cm(3), respectively; P<.0001). BMACT V30 was significantly correlated with a reduction in BMACT SUV (R(2), 0.14; P<.001). The reduction in BMACT SUV significantly correlated with reduction in white blood cells (WBCs) at 3 months post-treatment (R(2), 0.27; P=.04) and at last follow-up (R(2), 0.25; P=.04). Different dosimetric parameters of BMTOT and BMACT correlated with long-term hematological outcome. CONCLUSIONS: The volumes of BMTOT and BMACT that are exposed to even relatively low doses of radiation are associated with a decrease in WBC counts following CRT. The loss in proliferative BM SUV uptake translates into low WBC nadirs after treatment. These results suggest the potential of intensity modulated radiation therapy to spare BMTOT to reduce long-term hematological toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed the initial adhesion and biofilm formation of Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) on various bone grafts and bone graft substitutes under standardized in vitro conditions. In parallel, microcalorimetry was evaluated as a real-time microbiological assay in the investigation of biofilm formation and material science research. The materials beta-tricalcium phosphate (beta-TCP), processed human spongiosa (Tutoplast) and poly(methyl methacrylate) (PMMA) were investigated and compared with polyethylene (PE). Bacterial counts (log(10) cfu per sample) were highest on beta-TCP (S. aureus 7.67 +/- 0.17; S. epidermidis 8.14 +/- 0.05) while bacterial density (log(10) cfu per surface) was highest on PMMA (S. aureus 6.12 +/- 0.2, S. epidermidis 7.65 +/- 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (beta-TCP and processed human spongiosa, p < 0.001) compared to the smooth materials (PMMA and PE), with no differences between beta-TCP and processed human spongiosa (p > 0.05) or PMMA and PE (p > 0.05). In contrast, for S. epidermidis biofilms the detection time was different (p < 0.001) between all materials except between processed human spongiosa and PE (p > 0.05). The quantitative analysis by quantitative culture after washing and sonication of the material demonstrated the importance of monitoring factors like specific surface or porosity of the test materials. Isothermal microcalorimetry proved to be a suitable tool for an accurate, non-invasive and real-time microbiological assay, allowing the detection of bacterial biomass without removing the biofilm from the surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Par le biais d'une procédure Test-Retest, la stabilité à long terme des indices standard du WISC-IV français a été évaluée. L'intervalle moyen entre les deux passations est de 2,33 ans. L'échantillon comprend 96 enfants « tout venant » âgés de huit à 12 ans. Les comparaisons entre les moyennes des deux passations ne montrent pas de différence significative pour indice de compréhension verbale (ICV), indice de raisonnement perceptif (IRP), indice de mémoire de travail (IMT), indice d'aptitude générale (IAG) et QIT. Au niveau interindividuel, les coefficients de corrélations témoignent d'une bonne stabilité à long terme pour ICV, IAG et QIT (allant de 0,81 à 0,82). Une analyse des différences de performances entre les deux passations indique une stabilité intra-individuelle satisfaisante pour IMT et IAG. Seul IAG présente donc une stabilité à long terme satisfaisante au niveau inter- et intra-individuel. By a Test-Retest procedure, this study explores the long-term stability of the French WISC-IV index scores. The average Test-Retest interval was 2.33 years. The sample consisted of 96 non-clinical children aged between 8 and 12 years. Mean difference between the two testings was not statistically significant for VCI, PRI, WMI, GAI and FSIQ. Test-Retest reliability correlations between the two assessments are high for VCI, GAI and FSIQ (ranging from .81 to .82). An analysis of the performance differences between two assessments indicates intra-individual stability for WMI and GAI. In sum, only GAI demonstrates reliable long-term stability at an inter-and intra-individual level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While the incidence of sleep disorders is continuously increasing in western societies, there is a clear demand for technologies to asses sleep-related parameters in ambulatory scenarios. The present study introduces a novel concept of accurate sensor to measure RR intervals via the analysis of photo-plethysmographic signals recorded at the wrist. In a cohort of 26 subjects undergoing full night polysomnography, the wrist device provided RR interval estimates in agreement with RR intervals as measured from standard electrocardiographic time series. The study showed an overall agreement between both approaches of 0.05 ± 18 ms. The novel wrist sensor opens the door towards a new generation of comfortable and easy-to-use sleep monitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces a nonlinear measure of dependence between random variables in the context of remote sensing data analysis. The Hilbert-Schmidt Independence Criterion (HSIC) is a kernel method for evaluating statistical dependence. HSIC is based on computing the Hilbert-Schmidt norm of the cross-covariance operator of mapped samples in the corresponding Hilbert spaces. The HSIC empirical estimator is very easy to compute and has good theoretical and practical properties. We exploit the capabilities of HSIC to explain nonlinear dependences in two remote sensing problems: temperature estimation and chlorophyll concentration prediction from spectra. Results show that, when the relationship between random variables is nonlinear or when few data are available, the HSIC criterion outperforms other standard methods, such as the linear correlation or mutual information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated midterm patient-reported outcomes and satisfaction with total hip arthroplasty in patients who had severe juvenile idiopathic arthritis. Thirty-one patients (49 hips), with a mean age of 29 years (range, 16-43 years), reported low hip pain and stiffness at follow-up (mean, 7 years; range, 3-17 years). Up to 92% were satisfied with their ability to perform various activities; 96% were satisfied with pain relief. A mean postoperative flexion arc of 96° was observed. Final 36-Item Short Form Health Survey, EuroQol in 5 dimensions, Western Ontario and McMaster Universities Arthritis Index, and Harris Hip scores were lower than reference populations, particularly for mobility, physical functioning, and social functioning subscores. Young adults with end-stage hip involvement and severe longstanding juvenile idiopathic arthritis expressed high satisfaction with total hip arthroplasty, which improved range of motion, pain, and stiffness, despite poor performance on widely used outcome measures.