777 resultados para Performance of algae


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, zinc indium tin oxide layers with different compositions are used as the active layer of thin film transistors. This multicomponent transparent conductive oxide is gaining great interest due to its reduced content of the scarce indium element. Experimental data indicate that the incorporation of zinc promotes the creation of oxygen vacancies. In thin-film transistors this effect leads to a higher threshold voltage values. The field-effect mobility is also strongly degraded, probably due to coulomb scattering by ionized defects. A post deposition annealing in air reduces the density of oxygen vacancies and improves the fieldeffect mobility by orders of magnitude. Finally, the electrical characteristics of the fabricated thin-film transistors have been analyzed to estimate the density of states in the gap of the active layers. These measurements reveal a clear peak located at 0.3 eV from the conduction band edge that could be attributed to oxygen vacancies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a detailed evaluation of the seasonal performance of the Community Multiscale Air Quality (CMAQ) modelling system and the PSU/NCAR meteorological model coupled to a new Numerical Emission Model for Air Quality (MNEQA). The combined system simulates air quality at a fine resolution (3 km as horizontal resolution and 1 h as temporal resolution) in north-eastern Spain, where problems of ozone pollution are frequent. An extensive database compiled over two periods, from May to September 2009 and 2010, is used to evaluate meteorological simulations and chemical outputs. Our results indicate that the model accurately reproduces hourly and 1-h and 8-h maximum ozone surface concentrations measured at the air quality stations, as statistical values fall within the EPA and EU recommendations. However, to further improve forecast accuracy, three simple bias-adjustment techniques mean subtraction (MS), ratio adjustment (RA), and hybrid forecast (HF) based on 10 days of available comparisons are applied. The results show that the MS technique performed better than RA or HF, although all the bias-adjustment techniques significantly reduce the systematic errors in ozone forecasts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to better understand the specificity of training adaptations, we compared the effects of two different anaerobic training regimes on various types of soccer-related exercise performances. During the last 3 weeks of the competitive season, thirteen young male professional soccer players (age 18.5±1 yr, height 179.5±6.5 cm, body mass 74.3±6.5 kg) reduced the training volume by ~20% and replaced their habitual fitness conditioning work with either speed endurance production (SEP; n = 6) or speed endurance maintenance (SEM; n = 7) training, three times per wk. SEP training consisted of 6-8 reps of 20-s all-out running bouts followed by 2 min of passive recovery, whereas SEM training was characterized by 6-8 x 20-s all-out efforts interspersed with 40 s of passive recovery. SEP training reduced (p<0.01) the total time in a repeated sprint ability test (RSAt) by 2.5%. SEM training improved the 200-m sprint performance (from 26.59±0.70 to 26.02±0.62 s, p<0.01) and had a likely beneficial impact on the percentage decrement score of the RSA test (from 4.07±1.28 to 3.55±1.01%) but induced a very likely impairment in RSAt (from 83.81±2.37 to 84.65±2.27 s). The distance covered in the Yo-Yo Intermittent Recovery test level 2 was 10.1% (p<0.001) and 3.8% (p<0.05) higher after SEP and SEM training, respectively, with possibly greater improvements following SEP compared to SEM. No differences were observed in the 20- and 40-m sprint performances. In conclusion, these two training strategies target different determinants of soccer-related physical performance. SEP improved repeated sprint and high-intensity intermittent exercise performance, whereas SEM increased muscles' ability to maximize fatigue tolerance and maintain speed development during both repeated all-out and continuous short-duration maximal exercises. These results provide new insight into the precise nature of a stimulus necessary to improve specific types of athletic performance in trained young soccer players.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compares the impact of quality management tools on the performance of organisations utilising the ISO 9001:2000 standard as a basis for a quality-management system band those utilising the EFQM model for this purpose. A survey is conducted among 107 experienced and independent quality-management assessors. The study finds that organisations with qualitymanagement systems based on the ISO 9001:2000 standard tend to use general-purpose qualitative tools, and that these do have a relatively positive impact on their general performance. In contrast, organisations adopting the EFQM model tend to use more specialised quantitative tools, which produce significant improvements in specific aspects of their performance. The findings of the study will enable organisations to choose the most effective quality-improvement tools for their particular quality strategy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Cherenkov light flashes produced by Extensive Air Showers are very short in time. A high bandwidth and fast digitizing readout, therefore, can minimize the influence of the background from the light of the night sky, and improve the performance in Cherenkov telescopes. The time structure of the Cherenkov image can further be used in single-dish Cherenkov telescopes as an additional parameter to reduce the background from unwanted hadronic showers. A description of an analysis method which makes use of the time information and the subsequent improvement on the performance of the MAGIC telescope (especially after the upgrade with an ultra fast 2 GSamples/s digitization system in February 2007) will be presented. The use of timing information in the analysis of the new MAGIC data reduces the background by a factor two, which in turn results in an enhancement of about a factor 1.4 of the flux sensitivity to point-like sources, as tested on observations of the Crab Nebula.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To evaluate the performance of diagnostic centers in the classification of mammography reports from an opportunistic screening undertaken by the Brazilian public health system (SUS) in the municipality of Goiânia, GO, Brazil in 2010. Materials and Methods The present ecological study analyzed data reported to the Sistema de Informação do Controle do Câncer de Mama (SISMAMA) (Breast Cancer Management Information System) by diagnostic centers involved in the mammographic screening developed by the SUS. Based on the frequency of mammograms per BI-RADS® category and on the limits established for the present study, the authors have calculated the rate of conformity for each diagnostic center. Diagnostic centers with equal rates of conformity were considered as having equal performance. Results Fifteen diagnostic centers performed mammographic studies for SUS and reported 31,198 screening mammograms. The performance of the diagnostic centers concerning BI-RADS classification has demonstrated that none of them was in conformity for all categories, one center presented conformity in five categories, two centers, in four categories, three centers, in three categories, two centers, in two categories, four centers, in one category, and three centers with no conformity. Conclusion The results of the present study demonstrate unevenness in the diagnostic centers performance in the classification of mammograms reported to SISMAMA from the opportunistic screening undertaken by SUS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: For the past decade (18)F-fluoro-ethyl-l-tyrosine (FET) and (18)F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) have been used for the assessment of patients with brain tumor. However, direct comparison studies reported only limited numbers of patients. Our purpose was to compare the diagnostic performance of FET and FDG-PET. METHODS: We examined studies published between January 1995 and January 2015 in the PubMed database. To be included the study should: (i) use FET and FDG-PET for the assessment of patients with isolated brain lesion and (ii) use histology as the gold standard. Analysis was performed on a per patient basis. Study quality was assessed with STARD and QUADAS criteria. RESULTS: Five studies (119 patients) were included. For the diagnosis of brain tumor, FET-PET demonstrated a pooled sensitivity of 0.94 (95% CI: 0.79-0.98) and pooled specificity of 0.88 (95% CI: 0.37-0.99), with an area under the curve of 0.96 (95% CI: 0.94-0.97), a positive likelihood ratio (LR+) of 8.1 (95% CI: 0.8-80.6), and a negative likelihood ratio (LR-) of 0.07 (95% CI: 0.02-0.30), while FDG-PET demonstrated a sensitivity of 0.38 (95% CI: 0.27-0.50) and specificity of 0.86 (95% CI: 0.31-0.99), with an area under the curve of 0.40 (95% CI: 0.36-0.44), an LR+ of 2.7 (95% CI: 0.3-27.8), and an LR- of 0.72 (95% CI: 0.47-1.11). Target-to-background ratios of either FDG or FET, however, allow distinction between low- and high-grade gliomas (P > .11). CONCLUSIONS: For brain tumor diagnosis, FET-PET performed much better than FDG and should be preferred when assessing a new isolated brain tumor. For glioma grading, however, both tracers showed similar performances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fundamental question in the transitional economies of the former Eastern Europe and Soviet Union has been whether privatisation and market liberalisation have had an effect on the performance of former state-owned enterprises. This study examines the effect of privatisation, capital market discipline, price liberalisation and international price exposure on the restructuring of large Russian enterprises. The performance indicators are sales, profitability, labour productivity and stock market valuations. The results do not show performance differences between state-owned and privatised enterprises. On the other hand, the expansion of the de novo private sector has been strong. New enterprises have significantly higher sales growth, profitability and labour productivity. However, the results indicate a diminishing effect of ownership. The international stock market listing has a significant positive effect on profitability, while the effect of domestic stock market listing is insignificant. The international price exposure has a significant positive increasing effect on profitability and labour productivity. International enterprises have higher profitability only when operating on price liberalised markets, however. The main results of the study are strong evidence on the positive effects of international linkages on the enterprise restructuring and the higher than expected role of new enterprises in the Russian economy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the performance of the Tuberculin Skin Test (TST) and Quantiferon-TB Gold in-Tube (QFT) and the possible association of factors which may modify their results in young children (0-6 years) with recent contact with an index tuberculosis case. Materials and Methods: A cross-sectional study including 135 children was conducted in Manaus, Amazonas-Brazil. The TST and QFT were performed and the tests results were analyzed in relation to the personal characteristics of the children studied and their relationship with the index case. Results: The rates of positivity were 34.8% (TST) and 26.7% (QFT), with 14.1% of indeterminations by the QFT. Concordance between tests was fair (Kappa = 0.35 P<0.001). Both the TST and QFT were associated with the intensity of exposure (Linear OR = 1.286, P = 0.005; Linear OR = 1.161, P = 0.035 respectively) with only the TST being associated with the time of exposure (Linear OR = 1.149, P = 0.009). The presence of intestinal helminths in the TST+ group was associated with negative QFT results (OR = 0.064, P = 0.049). In the TST- group lower levels of ferritin were associated with QFT+ results (Linear OR = 0.956, P = 0.036). Conclusions: Concordance between the TST and QFT was lower than expected. The factors associated with the discordant results were intestinal helminths, ferritin levels and exposure time to the index tuberculosis case. In TST+ group, helminths were associated with negative QFT results suggesting impaired cell-mediated immunity. The TST-&QFT+ group had a shorter exposure time and lower ferritin levels, suggesting that QFT is faster and ferritin may be a potential biomarker of early stages of tuberculosis infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Following earlier work by Audretsch et al. (2002), we assume that an optimal size-class structure exists, in terms of achieving maximal economic growth rates. Such an optimal structure is likely to exist as economies need a balance between the core competences of large firms (such as exploitation of economies of scale) and those of smaller firms (such as flexibility and exploration of new ideas). Accordingly, changes in size-class structure (i.e., changes in the relative shares in economic activity accounted for by micro, small, medium-sized and large firms) may affect macro-economic growth. Using a unique data base of the EU-27 countries for the period 2002-2008 for five broad sectors of economic activity and four size-classes, we find empirical support which suggests that, on average for these countries over this period, the share of micro and large firms may have been ‘above optimum’ (particularly in lower income EU countries) whereas the share of medium-sized firms may have been ‘below optimum’ (particularly in higher income EU countries). This evidence suggests that the transition from a ‘managed’ to an ‘entrepreneurial’ economy (Audretsch and Thurik, 2001) has not been completed yet in all countries of the EU-27. Keywords: small firms, large firms, size-classes, macro-economic performance

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän diplomityön tavoitteena oli analysoida Stora Enson palkkakeskuksen ja sen henkilöstöhallinnon järjestelmän, SAP HR:n, kustannustehokkuutta ja suorituskykyä. Tutkimuksessa käytettiin apuna benchmarkingia. Viisi suurta suomalaisyritystä osallistui benchmarkingiin. Benchmarkingin pääkohteena oli yritysten välinen kustannusvertailu. Kyselyssä perehdyttiin myös yritysten järjestelmien suorituskykyyn. Tuloksien perusteella Stora Enson palkkakeskus tarjoaa kustannustehokkaan ja kilpailukykyisen ratkaisun, joka menestyy hyvin vertailussa muihin suomalaisiin yrityksiin.