797 resultados para Performance Measurement System, PMS, review PMS, KPIs


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study measured the postures of older people during cooking and laundry. A sample of men and women aged 75+ years (n=27) was recruited and observed in a home-like environment. Postures were recorded with a measurement system in an objective and detailed manner. The participants were videotaped to be able to see where 'critical' postures occurred, as defined by a trunk inclination of ≥60°. Analysis of data was facilitated by specially developed software. Critical postures accounted for 3% of cooking and 10% of laundry, occurring primarily during retrieving from and putting in lower cabinets, the refrigerator, laundry basket or washing machine as well as disposing into the waste bin. These tasks involve a great variation in postural changes and pose a particular risk to older people. The results suggest that the use of stressful postures may decrease efficiency and increase fatigue, eventually leading to difficulties with daily activities. The specific tasks identified during which critical postures occurred should be targeted by designers in order to improve the activities. A few examples are given of how better design can reduce or eliminate some of the postural constraints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transient test facilities offer the potential for the simultaneous study of turbine aerodynamic performance, unsteady flow phenomena and the heat transfer characteristics of a turbine stage. This paper describes the development of aerodynamic performance measurement techniques in the Oxford Rotor Facility (ORF). The solutions to the technological issues involved with transient testing presented in this paper are expected to achieve levels of precision uncertainty comparable with traditional steady flow test rigs. The theoretical background to the measurement of aerodynamic performance is presented together with a comprehensive pre-test uncertainty analysis. The instrumentation scheme for the measurement of stage mass flow rate is discussed in detail, the measurements of shaft power, total inlet enthalpy, and stage pressure ratio are also outlined. The current working section features a 62% scale, 1-1/2 stage, high-pressure shroudless transonic turbine. The required inlet flow conditions are provided by an Isentropic Light Piston Tunnel (ILPT) with a quasi-steady state run time of approximately 70ms. The testing is conducted at engine representative specific speed, pressure ratio, gas-to-wall temperature ratio, Mach number and Reynolds number.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - The purpose of this paper is to explore the concept of performance plumbing, arguing that too often performance management systems in organisations are not correctly installed. Without the appropriate plumbing, performance management systems do not drive organisational change and improvement. Design/methodology/approach - The paper draws on the consultancy experiences of two of the authors, as well as the research of the third. Specific case examples are provided throughout the paper to illustrate the points being made. Findings - The paper argues that the key elements of a plumbed-in performance management system are: performance architecture; performance insights; performance focus; and performance action. Taken together, these four elements provide the necessary plumbing to enable performance management systems to deliver real value. Research limitations/implications - The paper draws on the experience of the authors, rather than a formally designed piece of research. The ideas presented in the paper would therefore benefit from further investigation and testing. Originality/value - The paper will be valuable to scholars and practitioners interested in ensuring that performance management systems deliver lasting value. © Emerald Group Publishing Limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optimisation of cooling systems within gas turbine engines is of great interest to engine manufacturers seeking gains in performance, efficiency and component life. The effectiveness of coolant delivery is governed by complex flows within the stator wells and the interaction of main annulus and cooling air in the vicinity of the rim seals. This paper reports the development of a test facility which allows the interaction of cooling air and main gas paths to be measured at conditions representative of those found in modern gas turbine engines. The test facility features a two stage turbine with an overall pressure ratio of approximately 2.6:1. Hot air is supplied to the main annulus using a Rolls-Royce Dart compressor driven by an aero-derivative engine plant. Cooling air can be delivered to the stator wells at multiple locations and at a range of flow rates which cover bulk ingestion through to bulk egress. The facility has been designed with adaptable geometry to enable rapid changes of cooling air path configuration. The coolant delivery system allows swift and accurate changes to the flow settings such that thermal transients may be performed. Particular attention has been focused on obtaining high accuracy data, using a radio telemetry system, as well as thorough through-calibration practices. Temperature measurements can now be made on both rotating and stationary discs with a long term uncertainty in the region of 0.3 K. A gas concentration measurement system has also been developed to obtain direct measurement of re-ingestion and rim seal exchange flows. High resolution displacement sensors have been installed in order to measure hot running geometry. This paper documents the commissioning of a test facility which is unique in terms of rapid configuration changes, non-dimensional engine matching and the instrumentation density and resolution. Example data for each of the measurement systems is presented. This includes the effect of coolant flow rate on the metal temperatures within the upstream cavity of the turbine stator well, the axial displacement of the rotor assembly during a commissioning test, and the effect of coolant flow rate on mixing in the downstream cavity of the stator well. Copyright © 2010 by ASME.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on time-resolved Kerr rotation measurements of spin coherence of electrons in the first excited subband of a high-mobility low-density two-dimensional electron system in a GaAs/Al0.35Ga0.65As heterostructure. While the transverse spin lifetime (T-2(*)) of electrons decreases monotonically with increasing magnetic field, it has a nonmonotonic dependence on the temperature and reaches a peak value of 596 ps at 36 K, indicating the effect of intersubband electron-electron scattering on the electron-spin relaxation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gain measurement technique, based on Fourier series expansion of periodically extended single fringe of the amplified spontaneous emission spectrum, is proposed for Fabry-Perot semiconductor lasers. The underestimation of gain due to the limited resolution of the measurement system is corrected by a factor related to the system response function. The standard deviations of the gain-reflectivity product under low noise conditions are analyzed for the Fourier series expansion method and compared with those of the Hakki-Paoli method and Cassidy's method. The results show that the Fourier series expansion method is the least sensitive to noise among the three methods. The experiment results obtained by the three methods are also presented and compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate technique for measuring the frequency response of semiconductor laser diode chips is proposed and experimentally demonstrated. The effects of test jig parasites can be completely removed in the measurement by a new calibration method. In theory, the measuring range of the measurement system is only determined by the measuring range of the instruments network analyzer and photo detector. Diodes' bandwidth of 7.5GHz and 10GHz is measured. The results reveal that the method is feasible and comparing with other method, it is more precise andeasier to use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PSD是一种高分辨率、实时性好的光电位置敏感器件,因而具有广泛应用的前景.但在光照度变化条件下,输出信号存在非线性飘移,因而影响了作为位置检测传感器的检测精度,尤其在3D测量时适用性受到了限制.针对这个问题,提出了一种PSD位置传感器的非线性误差补偿方法.该方法针对目标的空间距离变化所产生的PSD输出非线性飘移,采用归一化模型进行误差修正,很大程度上改进了PSD的输出一致性,使基于PSD的3D测量系统性能得以提高.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To investigate the value of using PROMs as quality improvement tools. Methods: Two systematic reviews were undertaken. The first reviewed the quantitative literature on the impact of PROMs feedback and the second reviewed the qualitative literature on the use of PROMs in practice. These reviews informed the focus of the primary research. A cluster randomised controlled trial (PROFILE) examined the impact of providing peer benchmarked PROMs feedback to consultant orthopaedic surgeons on improving outcomes for hip replacement surgery. Qualitative interviews with surgeons in the intervention arm of the trial examined the view of and reactions to the feedback. Results: The quantitative review of 17 studies found weak evidence to suggest that providing PROMs feedback to professionals improves patient outcomes. The qualitative review of 16 studies identified the barriers and facilitators to the use of PROMs based on four themes: practical considerations, attitudes towards the data, methodological concerns and the impact of feedback on care. The PROFILE trial included 11 surgeons and 215 patients in the intervention arm, and 10 surgeons and 217 patients in the control arm. The trial found no significant difference in the Oxford Hip Score between the arms (-0.7, 95% CI -1.9-0.5, p=0.2). Interviews with surgeons revealed mixed opinions about the value of the PROMs feedback and the information did not promote explicit changes to their practice. Conclusion: It is important to use PROMs which have been validated for the specific purpose of performance measurement, consult with professionals when developing a PROMs feedback intervention, communicate with professionals about the objectives of the data collection, educate professionals on the properties and interpretation of the data, and support professionals in using the information to improve care. It is also imperative that the burden of data collection and dissemination of the information is minimised.