934 resultados para Low-Level Light Therapy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work investigated the effect of gallium arsenide (GaAs) irradiation (power: 5 mW; intensity: 77.14 mW/cm(2), spot: 0.07 cm(2)) on regenerating skeletal muscles damaged by crotoxin (CTX). Male C57Bl6 mice were divided into six groups (n = 5 each): control, treated only with laser at doses of 1.5 J or 3 J, CTX-injured and, CTX-injured and treated with laser at doses of 1.5 J or 3 J. The injured groups received a CTX injection into the tibialis anterior (TA) muscle. After 3 days, TA muscles were submitted to GaAs irradiation at doses of 1.5 or 3 J (once a day, during 5 days) and were killed on the eighth day. Muscle histological sections were stained with hematoxylin and eosin (H&E) in order to determine the myofiber cross-sectional area (CSA), the previously injured muscle area (PIMA) and the area density of connective tissue. The gene expression of MyoD and myogenin was detected by real-time PCR. GaAs laser at a dose of 3 J, but not 1.5 J, significantly increased the CSA of regenerating myofibers and reduced the PIMA and the area density of intramuscular connective tissue of CTX-injured muscles. MyoD gene expression increased in the injured group treated with GaAs laser at a dose of 1.5 J. The CTX-injured, 3-J GaAs laser-treated, and the CTX-injured and treated with 3-J laser groups showed an increase in myogenin gene expression when compared to the control group. Our results suggest that GaAs laser treatment at a dose of 3 J improves skeletal muscle regeneration by accelerating the recovery of myofiber mass.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study aimed to investigate the effect of 830 and 670 nm diode laser on the viability of random skin flaps in rats. Background data: Low-level laser therapy (LLLT) has been reported to be successful in stimulating the formation of new blood vessels and reducing the inflammatory process after injury. However, the efficiency of such treatment remains uncertain, and there is also some controversy regarding the efficacy of different wavelengths currently on the market. Materials and methods: Thirty Wistar rats were used and divided into three groups, with 10 rats in each. A random skin flap was raised on the dorsum of each animal. Group 1 was the control group, group 2 received 830 nm laser radiations, and group 3 was submitted to 670 nm laser radiation (power density = 0.5 mW/cm(2)). The animals underwent laser therapy with 36 J/cm(2) energy density (total energy = 2.52 J and 72 sec per session) immediately after surgery and on the 4 subsequent days. The application site of laser radiation was one point at 2.5 cm from the flap's cranial base. The percentage of skin flap necrosis area was calculated on the 7th postoperative day using the paper template method. A skin sample was collected immediately after to determine the vascular endothelial growth factor (VEGF) expression and the epidermal cell proliferation index (KiD67). Results: Statistically significant differences were found among the percentages of necrosis, with higher values observed in group 1 compared with groups 2 and 3. No statistically significant differences were found among these groups using the paper template method. Group 3 presented the highest mean number of blood vessels expressing VEGF and of cells in the proliferative phase when compared with groups 1 and 2. Conclusions: LLLT was effective in increasing random skin flap viability in rats. The 670 nm laser presented more satisfactory results than the 830 nm laser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Treatment efficacy of physical agents in osteoarthritis of the knee (OAK) pain has been largely unknown, and this systematic review was aimed at assessing their short-term efficacies for pain relief. Methods Systematic review with meta-analysis of efficacy within 1–4 weeks and at follow up at 1–12 weeks after the end of treament. Results 36 randomised placebo-controlled trials (RCTs) were identified with 2434 patients where 1391 patients received active treatment. 33 trials satisfied three or more out of five methodological criteria (Jadad scale). The patient sample had a mean age of 65.1 years and mean baseline pain of 62.9 mm on a 100 mm visual analogue scale (VAS). Within 4 weeks of the commencement of treatment manual acupuncture, static magnets and ultrasound therapies did not offer statistically significant short-term pain relief over placebo. Pulsed electromagnetic fields offered a small reduction in pain of 6.9 mm [95% CI: 2.2 to 11.6] (n = 487). Transcutaneous electrical nerve stimulation (TENS, including interferential currents), electro-acupuncture (EA) and low level laser therapy (LLLT) offered clinically relevant pain relieving effects of 18.8 mm [95% CI: 9.6 to 28.1] (n = 414), 21.9 mm [95% CI: 17.3 to 26.5] (n = 73) and 17.7 mm [95% CI: 8.1 to 27.3] (n = 343) on VAS respectively versus placebo control. In a subgroup analysis of trials with assumed optimal doses, short-term efficacy increased to 22.2 mm [95% CI: 18.1 to 26.3] for TENS, and 24.2 mm [95% CI: 17.3 to 31.3] for LLLT on VAS. Follow-up data up to 12 weeks were sparse, but positive effects seemed to persist for at least 4 weeks after the course of LLLT, EA and TENS treatment was stopped. Conclusion TENS, EA and LLLT administered with optimal doses in an intensive 2–4 week treatment regimen, seem to offer clinically relevant short-term pain relief for OAK.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a ação precoce do laser terapêutico e do ultrassom no processo de regeneração de uma lesão experimental em ratos. MÉTODO: Utilizou-se 24 ratos. Dezoito foram submetidos ao procedimento cirúrgico de lesão do nervo ciático por compressão, através de uma pinça hemostática acima da fossa poplítea. Os animais foram divididos em três grupos com seis animais em cada. Grupo controle normal. GI: controle lesado sem intervenção terapêutica. GII: intervenção terapêutica do laser ArGaAl. GIII: intervenção terapêutica do ultrassom Pulsado. Iniciamos as intervenções terapêuticas 24 horas após a lesão, com aplicações diárias, por um período de quatorze dias consecutivos. RESULTADOS: Ao avaliar a perimetria dos músculos da coxa direita obteve-se os seguintes valores médios de diminuição (mm), para cada grupo GI: 0,45; GII: 0,42; GIII: 0,40. Quanto ao tempo de deslocamento tanto o GII e GIII apresentaram diferença significativa, quando comparados ao GI. Na avaliação final do IFC o GII sobressaiu ao GIII. Quanto a cicatrização observou-se grande melhora no GII e GIII. CONCLUSÃO: Os resultados evidenciaram que a recuperação nervosa foi maior com a aplicação do laser. Nível de evidência II, Estudos terapêuticos - Investigação dos resultados do tratamento

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pre-treatment of tumour neovessels by low-level photodynamic therapy (PDT) improves the distribution of concomitantly administered systemic chemotherapy. The mechanism by which PDT permeabilizes the tumour vessel wall is only partially known. We have recently shown that leukocyte-endothelial cell interaction is essential for photodynamic drug delivery to normal tissue. The present study investigates whether PDT enhances drug delivery in malignant mesothelioma and whether it involves comparable mechanisms of actions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O laser de baixa intensidade (LBI) tem demonstrado efeitos bioestimulatórios na movimentação ortodôntica, acelerando a resposta celular e, reduzindo o tempo de tratamento. Entretanto, o uso do LBI seria mais efetivo com maior potência, menor tempo (única irradiação), ou a junção da menor potência e tempo em aplicação fracionada? Este estudo visou quantificar a movimentação de molares de 64 ratos e suas alterações histológicas, submetidos a uma força ortodôntica, liberada por meio de uma mola fechada de níquel-titânio (Niti/25gf), calibrada em 20gf. Os animais foram divididos em quatro grupos (cada grupo com 16 ratos), de acordo com os seguintes protocolos de irradiação do laser GaAlAs(780nm): grupo controle , submetidos à movimentação ortodôntica mas sem aplicação do LBI ; grupo total 1 (P=60mW/DE=15J/cm²/Et=6J/t=100seg), com a movimentação ortodôntica associada à única aplicação do LBI laser (P=60mW/DE=15J/cm²/Et=6J/t=100seg) no dia zero. Grupo total 2 em que o LBI foi aplicado no dia 0, segundo o protocolo P=20mW/DE=15J/cm²/E=6J/t=300seg;,; e Grupo fracionado em que o LBI foi aplicado nos dias 0, 3 e 7, empregando-se o protocolo (P=20mW/DE=5J/cm²/E=2J/t=100seg). Os sacrifício dos ratos foi realizado em quatro momentos (dias 1,4,8 e 15), sendo que 4 ratos de cada grupo foi sacrificado em cada um dos dias. A quantidade de movimentação ortodôntica foi mensurada in loco por meio de paquímetro digital, antes da instalação das molas e, imediatamente após o sacrifício dos animais. Para o exame histológico, as maxilas foram removidas, preparadas e coradas pelo sistema H/E. Os resultados foram avaliados pela Análise de Variância, seguida do teste Tukey (p<0,05). O grupo fracionado apresentou maior movimentação dentária frente aos demais nos dias 4 e 8, sendo que os grupos total 1 e 2 demonstraram maior movimentação dentária que o controle somente no dia 8. Não houve diferença estatisticamente significante entre os grupos total 1 e 2 em todo o período avaliado. Este estudo concluiu que, o laser de baixa intensidade acelerou a movimentação dentária, salientando-se o efeito da aplicação fracionada em relação às aplicações únicas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo objetivou avaliar a eficácia do Laser de Baixa Intensidade (LBI) na aceleração da movimentação dentária e na diminuição da dor frente à aplicação de força ortodôntica. A amostra foi composta por 19 pacientes, sendo doze do sexo feminino e sete do sexo masculino, com idade inicial média de 14,69 anos, todos com indicação para extrações de primeiros pré-molares. Destes, 66 caninos foram submetidos à retração inicial, sendo que 33 receberam aplicação de laser e 33 foram considerados controle. Utilizou-se o Laser de Baixa Intensidade de arseneto de gálio e alumínio, com comprimento de onda de 780nm, na dosimetria de 40mW;10J/cm2;10s/ponto, aplicado apenas uma vez ao mês em dez pontos, sendo cinco por vestibular e cinco por lingual/palatino. Modelos de gesso foram confeccionados durante todos os meses de retração dos caninos, que teve duração de quatro meses, sendo, posteriormente, digitalizados para se mensurar a quantidade de movimentação de um lado em relação ao outro, utilizando-se como referência as papilas incisivas. Para a avaliação da dor experimentada pelos pacientes, os mesmos foram orientados a preencher uma escala analógica visual (VAS) que variava de 0 a 10 , em que zero significava nenhuma dor e dez significava dor insuportável, nos intervalos de 12, 24, 48 e 72 horas após a aplicação da força ortodôntica. Foi mensurado o apinhamento de todas as hemiarcadas dos pacientes na fase inicial, medindo-se a distância entre os pontos de contato de cada dente. Para a verificação do padrão de normalidade, empregou-se o teste de Kolmogorov-Smirnov, sendo que para comparar o lado irradiado com o lado não irradiado foi utilizado o teste t pareado, exceto para a variável razão caninos/molares , analisada pelo teste não paramétrico de Wilcoxon (p<0,05). Os resultados mostraram que em relação ao apinhamento dentário, os lados irradiado e não irradiado apresentaram-se compatíveis. Além disso, não houve diferença estatisticamente significante entre a quantidade de retração dos caninos irradiados comparados aos não irradiados, o mesmo acontecendo com a sensibilidade dolorosa experimentada pelos pacientes. Concluiu-se assim que o LBI na dosimetria e forma como foi utilizado não foi eficiente na aceleração da movimentação dentária nem na redução da dor experimentada pelos pacientes frente às forças ortodônticas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inscription of Bragg gratings has been demonstrated in PMMA-based polymer optical fibre. The water affinity of PMMA can introduce significant wavelength change in a polymer optical fibre Bragg grating (POFBG). In polymer optical fibre losses are much higher than with silica fibre. Very strong absorption bands related to higher harmonics of vibrations of the C-H bond dominate throughout the visible and near infrared. Molecular vibration in substances generates heat, which is referred to as the thermal effect of molecular vibration. This means that a large part of the absorption of optical energy in those spectral bands will convert into thermal energy, which eventually drives water content out of the polymer fibre and reduces the wavelength of POFBG. In this work we have investigated the wavelength stability of POFBGs in different circumstances. The experiment has shown that the characteristic wavelength of a POFBG starts decreasing after a light source is applied to it. This decrease continues until equilibrium inside the fibre is established, depending on the initial water content inside the fibre, the surrounding humidity, the optical power applied, and the fibre size. Our investigation has shown that POFBGs operating at around 850 nm show much smaller wavelength reduction than those operating at around 1550 nm in the same fibre; POFBGs with different diameters show different changes; POFBGs powered by a low level light source, or operating in a very dry environment are least affected by this thermal effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inscription of Bragg gratings has been demonstrated in PMMA-based polymer optical fibre. The water affinity of PMMA can introduce significant wavelength change in a polymer optical fibre Bragg grating (POFBG). In polymer optical fibre losses are much higher than with silica fibre. Very strong absorption bands related to higher harmonics of vibrations of the C-H bond dominate throughout the visible and near infrared. Molecular vibration in substances generates heat, which is referred to as the thermal effect of molecular vibration. This means that a large part of the absorption of optical energy in those spectral bands will convert into thermal energy, which eventually drives water content out of the polymer fibre and reduces the wavelength of POFBG. In this work we have investigated the wavelength stability of POFBGs in different circumstances. The experiment has shown that the characteristic wavelength of a POFBG starts decreasing after a light source is applied to it. This decrease continues until equilibrium inside the fibre is established, depending on the initial water content inside the fibre, the surrounding humidity, the optical power applied, and the fibre size. Our investigation has shown that POFBGs operating at around 850 nm show much smaller wavelength reduction than those operating at around 1550 nm in the same fibre; POFBGs with different diameters show different changes; POFBGs powered by a low level light source, or operating in a very dry environment are least affected by this thermal effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diabetes Mellitus (DM ) is a complex disease that requires continuous medical care for the reduction of risk factors in addition to glycemic control. The typical hyperglycemia of this disease produces glycosylation of proteins and so the consequence is the accumulation of glycosylation final products in various human tissues, among them, the tendon. The aerobic exercise (AE) and the low level laser therapy (LLLT) have been used to treat tendinopathies in individuals with or without DM. Objective: The aim of this study was to watch the effect of the LLLT and the AE, in association, in partial tenotomy of the tissue repair of the Achilles tendon (AT) of diabetic rats. Methods: 91 animals were utilized and divided in to the following groups: control group (GC), injured control group (GCL), diabetic group (GD), diabetic group LLLT (GD – TLBI), diabetic group trained (GD - EX) and diabetic group trained laser (GD-EX+TLBI). The animals were submitted to intervention with AE, using a protocol with a progressive increase of time (12 to 60 min) and speed of (4 to 9 m/min), and the LLLT (660 nm laser, 10mW, 4 J/cm², single point for 16 seconds, three times for week). It was analyzed morphological, biomechanical and molecular characteristics. For data showing normal distribution was used one-way ANOVA test and post hoc Tukey and data without normal distribution was used Mann Whitney test and post hoc Dunn's. It was accepted p <0.05 for statistical significance Results: The biomechanical tests indicated major improvement in the GC and GD-EX+TLBI groups when compared with the diabetic groups in the following variables: maximum load, strain, absorbed energy, stress, cross section area, elastic modulus and energy density (p<0.05). The analysis through molecular biology indicated that the association of aerobic exercise and LLLT generated an increase of the collagen I gene expression and modulated the expression of the MMP2 and MMP9 (p<0.05). No observed any major improvement in the morphological variable studied. Conclusion: the LLLT associated with aerobic exercise promotes and increase of the mechanical properties, in the control of collagen I gene expression and of the MMP2 and MMP9 of the diabetic rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A etiologia da alveolite é desconhecida. Considera-se não haver uma causa específica, mas sim uma associação de factores inerentes ao seu aparecimento. O diagnóstico é realizado, geralmente, entre o 2º e 5º dia após exodontia, sendo bastante claro. Manifesta-se por uma dor aguda e pulsátil, mal controlada com analgésicos, e de apresentação clínica uma inflamação da mucosa em torno do alvéolo, com parcial ou total perda do coágulo, apresentando-se este vazio ou com tecido necrótico e/ou restos alimentares. Pode ainda haver uma exposição óssea. Diversas são as taxas de incidência, variando consoante os factores de risco predisponentes da doença. São estes a idade, género, ciclo menstrual e toma de contraceptivos orais (nas mulheres), trauma cirúrgico e experiência do médico, a indicação da extração, bem como características do dente a ser extraído, ainda as técnicas e anestesia usadas, bem como remanescentes ósseos e/ou radiculares, uso de retalhos e suturas, patologias sistémicas, medicação e cuidados pós-operatórios do doente. Todos estes podem ter impacto no desenvolvimento desta condição, devendo o médico dentista eliminá-los e reduzi-los ao máximo. A prevenção aplica-se a medidas não farmacológicas, como redução de factores de risco, em combinação a terapia farmacológica, de modo a favorecer uma correta cicatrização. Recurso a soluções antissépticas, medicação tópica (intra-alveolar) e prescrição sistémica de antibióticos e anti-inflamatórios não esteroides são algumas dessas medidas. Ao nível do tratamento, vários métodos e materiais estão disponíveis no mercado. Por ser uma condição que o próprio organismo “combate”, o objectivo terapêutico passa basicamente pela redução dos sintomas debilitantes do paciente e controlo bacteriano. A opção é individual, uma vez que não existe nenhum tratamento com características ideais, sendo os resultados na literatura bastante discrepantes. Limpeza do alvéolo, medicação intra-alveolar (tópica) e/ou sistémica, bem como terapia com laser de baixa intensidade, são algumas opções. A administração antibiótica deve ser reservada para casos especiais, não devendo ser abordada como método de rotina. Analgésicos são uma opção, podendo ser aconselhada consoante o quadro clínico doloroso. Também o reforço para uma higiene oral rigorosa, com irrigação do alvéolo para evitar detritos e impactação alimentar (no caso de não existirem obtundantes intra-alveolares) devem ser preocupação do médico dentista. Deve haver um seguimento regular do paciente, especialmente se aplicados medicamentos tópicos, para avaliação e renovação (se necessário) do curativo até recuperação. O médico dentista deve saber identificar um caso de alveolite, encontrando-se informado e consciente das várias opções preventivas e terapêuticas. Estudos mais claros e objectivos são necessários na procura de critérios de diagnóstico genéricos da doença, bem como terapêuticas preventivas e de tratamentos com taxas de sucesso altas e suportadas por evidência científica. Para que, desta forma, seja elaborado um protocolo universal a seguir na prática clínica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Behçet's disease (BD) is a multi-systemic vascular disorder characterized by oral and genital ulcers, cutaneous, ocular, arthritic, vascular, central nervous system and gastrointestinal involvement. It usually affects young adults and the etiopathogenesis is unknown. A 21-year-old girl, Caucasian, with diagnostic BD, presented with rheumatoid arthritis, genital lesions and multiple recurrent ulcers inside the mouth, with an erythematous halo, covered by yellowish exudates exacerbated during menstrual periods, and in situations of stress and anxiety. The application of low power laser in ulcers was considered in order to decrease the inflammatory symptoms and pain, beyond getting the healing process accelerated. The proposed therapy was able to promote pain relief, increase local microcirculation and repair ulcerated lesions, eliminating the need for administration of systemic or topical medications, leading to improved quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last years, phototherapy has becoming a promising tool to improve skeletal muscle recovery after exercise, however, it was not compared with other modalities commonly used with this aim. In the present study we compared the short-term effects of cold water immersion therapy (CWIT) and light emitting diode therapy (LEDT) with placebo LEDT on biochemical markers related to skeletal muscle recovery after high-intensity exercise. A randomized double-blind placebo-controlled crossover trial was performed with six male young futsal athletes. They were treated with CWIT (5A degrees C of temperature [SD +/- 1A degrees]), active LEDT (69 LEDs with wavelengths 660/850 nm, 10/30 mW of output power, 30 s of irradiation time per point, and 41.7 J of total energy irradiated per point, total of ten points irradiated) or an identical placebo LEDT 5 min after each of three Wingate cycle tests. Pre-exercise, post-exercise, and post-treatment measurements were taken of blood lactate levels, creatine kinase (CK) activity, and C-reactive protein (CRP) levels. There were no significant differences in the work performed during the three Wingate tests (p > 0.05). All biochemical parameters increased from baseline values (p < 0.05) after the three exercise tests, but only active LEDT decreased blood lactate levels (p = 0.0065) and CK activity (p = 0.0044) significantly after treatment. There were no significant differences in CRP values after treatments. We concluded that treating the leg muscles with LEDT 5 min after the Wingate cycle test seemed to inhibit the expected post-exercise increase in blood lactate levels and CK activity. This suggests that LEDT has better potential than 5 min of CWIT for improving short-term post-exercise recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess adherence to proton pump inhibitor (PPI) treatment and associated variables in patients with gastroesophageal reflux disease (GERD). Cross-sectional and prospective comprising 240 consecutive adult patients, diagnosed with GERD for whom continuous use of standard or double dose of omeprazole had been prescribed. Patients were ranked as ne-GERD (162: 67.5%) or e-GERD classified according to the Los Angeles classification as A (48:20.0%), B (21:8.6%), C (1:0.5%), D (1:0.5%), and Barrett's esophagus (7:2.9%). The Morisky questionnaire was applied to assess adherence to therapy and a GERD questionnaire to assess symptoms and their impact. Adherence was correlated with demographics, cotherapies, comorbidities, treatment duration, symptoms scores, endoscopic findings, and patient awareness of their disease. 126 patients (52.5%) exhibited high level of adherence and 114 (47.5%) low level. Youngers (P= 0.002) or married (O.R. 2.41, P= 0.03 vs. widowers) patients had lower levels of adherence; symptomatic patients exhibited lower adherence (P= 0.02). All other variables studied had no influence on adherence. Patients with GERD attending a tertiary referral hospital in Sao Paulo exhibited a high rate of low adherence to the prescribed PPI therapy that may play a role in the therapy failure. Age <60 years, marital status and being symptomatic were risk factors for low adherence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The low level of amphotropic retrovirus-mediated gene transfer into human hematopoietic stem cells (HSC) has been a major impediment to gene therapy for hematopoietic diseases. In the present study, we have examined amphotropic retrovirus receptor (amphoR) and ecotropic retrovirus receptor mRNA expression in highly purified populations of mouse and human HSC. Murine HSC with low to undetectable levels of amphoR mRNA and relatively high levels of ecotropic retrovirus receptor mRNA were studied. When these HSC were analyzed simultaneously for ecotropic and amphotropic retrovirus transduction, ecotropic provirus sequences were detected in 10 of 13 long-term repopulated animals, while amphotropic proviral sequences were detected in only one recipient. A second distinct population of murine HSC were isolated that express 3-fold higher levels of amphoR mRNA. When these HSC were analyzed simultaneously for ecotropic and amphotropic retrovirus transduction, 11 of 11 repopulated mice contained ecotropic provirus and 6 of 11 contained amphotropic provirus sequences, a significant increase in the amphotropic retrovirus transduction (P = 0.018). These results indicate that, among the heterogeneous populations of HSC present in adult mouse bone marrow, the subpopulation with the highest level of amphoR mRNA is more efficiently transduced by amphotropic retrovirus. In a related study, we found low levels of human amphoR mRNA in purified populations of human HSC (CD34+ CD38-) and higher levels in committed progenitor cells (CD34+ CD38+). We conclude that the amphoR mRNA level in HSC correlates with amphotropic retrovirus transduction efficiency.