987 resultados para Intravascular ultrasound imaging


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reconstruction of a cleft lip leads inevitably to scar tissue formation. Scar tissue within the restored oral orbicular muscle might be assessed by quantification of the local contractility of this muscle. Furthermore, information about the contraction capability of the oral orbicular muscle is crucial for planning the revision surgery of an individual patient. We used ultrasound elastography to determine the local deformation (strain) of the upper lip and to differentiate contracting muscle from passive scar tissue. Raw ultrasound data (radio-frequency format; rf-) were acquired, while the lips were brought from normal state into a pout condition and back in normal state, in three patients and three normal individuals. During this movement, the oral orbicular muscle contracts and, consequently, thickens in contrast to scar tissue that will not contract, or even expand. An iterative coarse-to-fine strain estimation method was used to calculate the local tissue strain. Analysis of the raw ultrasound data allows estimation of tissue strain with a high precision. The minimum strain that can be assessed reproducibly is 0.1%. In normal individuals, strain of the orbicular oral muscle was in the order of 20%. Also, a uniform strain distribution in the oral orbicular muscle was found. However, in patients deviating values were found in the region of the reconstruction and the muscle tissue surrounding that. In two patients with a successful reconstruction, strain was reduced by 6% in the reconstructed region with respect to the normal parts of the muscle (from 22% to 16% and from 25% to 19%). In a patient with severe aesthetical and functional disability, strain decreased from 30% in the normal region to 5% in the reconstructed region. With ultrasound elastography, the strain of the oral orbicular muscle can be quantified. In healthy subjects, the strain profiles and maximum strain values in all parts of the muscle were similar. The maximum strain of the muscle during pout was 20% +/- 1%. In surgically repaired cleft lips, decreased deformation was observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the response of RA patients to rituximab (RTX) treatment using a sensitive imaging technique for synovitis. METHODS: Twenty-three RA patients were treated with two 1000-mg infusions of the B-cell depleting antibody, RTX, in an observational protocol. Clinical response was assessed by the European League Against Rheumatism (EULAR) response criteria. High-resolution grey-scale and colour-coded power Doppler (PD) ultrasonography was performed at baseline and 6 months after RTX. The second to fifth MCP and PIP joints were bilaterally examined with joints in a neutral 0 position from a palmar view and scored from 0 to 3. RESULTS: Median disease activity score (DAS28) improved from 5.03 to 3.56 (P = 0.001), which corresponded to a EULAR moderate response in 11 of 23 patients and a EULAR good response in another 6 patients. Improved control of disease activity by RTX was also indicated by tapering of median daily corticosteroid doses from 10 to 5 mg, without flare ups. Mean grey-scale scores correlated with the swollen joint count at baseline (r = 0.484, P = 0.022) and month 6 (r = 0.519, P = 0.011). Mean grey-scale scores improved upon RTX from a 0.90 median (range 0.13-1.87) to 0.75 (range 0.19-1.50, P = 0.023). Frequency of PD positive joints was low (6.1%) at baseline and did not significantly change following RTX treatment. CONCLUSIONS: High-resolution grey-scale ultrasonography (US) examination confirmed reduced synovial hyperplasia, but the applied PD method displayed no significant changes. Therefore, only grey-scale US is recommended in follow-up examinations after RTX treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to describe normal magnetic resonance (MR) imaging anatomy of the equine larynx and pharynx and to present the optimal protocol, sequences, and possible limitations of this examination technique. Using a 0.3 T unit, the laryngeal and pharyngeal regions was imaged in two horses. The protocol consisted of sagittal and transverse T2-weighted (T2w) fast spin echo, transverse T1-weighted (T1w) spin echo, and dorsal high-resolution T1w gradient echo (both pre- and postcontrast enhancement) sequences. Euthanasia was performed at the end of the imaging procedure. Macroscopic anatomy of the cadaver sections were compared with the MR images in transverse, midsagittal, and parasagittal planes. There was good differentiation of anatomic structures, including soft tissues. The laryngeal cartilages, hyoid apparatus, and upper airway muscle groups with their attachments could be clearly identified. However, it was not always possible to delineate individual muscles in each plane. Most useful were both T2w and T1w transverse sequences. Intravenous application of contrast medium was helpful to identify blood vessels. The MR images corresponded with the macroscopic anatomy of cadaver sections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 7-year-old female spayed Scottish Terrier was presented with central nervous system symptoms suggestive of a lesion in the forebrain. Magnetic resonance (MR) imaging revealed multifocal disease in the forebrain. Because of complete lack of contrast enhancement, the changes were attributed to lesions of inflammatory origin.Histopathology of the brain revealed multiplemetastatic lesions of an adenocarcinoma. Brainmetastases in general show contrast enhancement. The reason for a complete absence of contrast enhancement is unknown. Previous administration of corticosteroids, increased diffusion time of contrast medium, increased intracranial pressure in combination with an intact blood–tumor barrier is discussed as possible reasons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Unilateral or bilateral axillary masses in children are often of clinical concern for malignancies. Our review illustrates a normal variant of the axilla mimicking clinically an axillary mass. Methods and Materials: Systematic review of our PACS and RIS with the keyword “axilla” and the modality “ultrasound” in children under 16 years of age from 1.12.2009 until 30.11.2012. 19 axillary ultrasound examinations in 16 patients (7m/9f, age 3 months to 15 years) were included. One patient was examined 2 and one patient 3 times. In 6 patients a prominent muscle was noted overlying the humeral head in an abducted position. The muscle diameter was measured in cm and compared with the contralateral side. In one patient photographs of the axilla were available. Results: In 16 examinations a lymphadenopathy (n=5), abscess formation (n=5), seroma or hematoma (n=1) or lymphangioma (n=1) and no diagnosis (n=1) was found. In 4 patients (25%) a unilateral muscle variant and in 2 patients a bilateral muscle variant (axillary arch muscle) was noted. In one patient a duplication of the muscle was found. In 4 patients the muscle was larger than the contralateral side. Conclusion: An axillary mass in children without other clinical complaints may be related to a normal variant, the axillary arch muscle. Ultrasound is the first modality of choice if imaging is required. Radiologists should be aware of this normal variant since no other workup is necessary in asymptomatic children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High resolution, vascular magnetic resonance imaging of the spine region in small animals poses several challenges. The small anatomical features, extravascular diffusion, and the low signal-to-noise ratio limit the use of conventional contrast agents. We hypothesize that a long circulating, intravascular liposomal-encapsulated MR contrast agent (liposomal-Gd) would facilitate visualization of small anatomical features of the perispinal vasculature not visible with conventional contrast agent (Gd-DTPA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: High-resolution, vascular MR imaging of the spine region in small animals poses several challenges. The small anatomic features, extravascular diffusion, and low signal-to-noise ratio limit the use of conventional contrast agents. We hypothesize that a long-circulating, intravascular liposomal-encapsulated MR contrast agent (liposomal-Gd) would facilitate visualization of small anatomic features of the perispinal vasculature not visible with conventional contrast agent (gadolinium-diethylene-triaminepentaacetic acid [Gd-DTPA]). METHODS: In this study, high-resolution MR angiography of the spine region was performed in a rat model using a liposomal-Gd, which is known to remain within the blood pool for an extended period. The imaging characteristics of this agent were compared with those of a conventional contrast agent, Gd-DTPA. RESULTS: The liposomal-Gd enabled acquisition of high quality angiograms with high signal-to-noise ratio. Several important vascular features, such as radicular arteries, posterior spinal vein, and epidural venous plexus were visualized in the angiograms obtained with the liposomal agent. The MR angiograms obtained with conventional Gd-DTPA did not demonstrate these vessels clearly because of marked extravascular soft-tissue enhancement that obscured the vasculature. CONCLUSIONS: This study demonstrates the potential benefit of long-circulating liposomal-Gd as a MR contrast agent for high-resolution vascular imaging applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Congenital uterine anomalies often remain asymptomatic until they cause problems, for example during pregnancy. We studied the diagnostic aspects of two- and three-dimensional ultrasound and MRI. Materials and Methods: 63 women referred for suspected uterine anomalies were studied: In the first group (until July 2008) with 2 D-US and MRI, in the second group (from August 2008) additionally with 3 D-US; these women also had diagnostic or therapeutic operative confirmation. In the third group, only 3D-US was used. Results: In all women 3D-US was possible and successful. The most common anomaly was a subseptate uterus, while a septate uterus was less frequent, and uterus bicornis (unicollis) and uterus didelphys (bicornis bicollis) were rare. The women in the first two groups all underwent at least diagnostic hysteroscopy, and some (subseptate or septate uterus) underwent operative hysteroscopy. After preoperative volume imaging, laparoscopies were required less often. 3D-US diagnoses as judged by intraoperative findings were correct in 100 % of cases, while the MRI diagnoses in the same group were correct in only 7/13 cases. Conclusion: Since the introduction of volume imaging (MRI, later 3 D-US), laparoscopy during hysteroscopic septum resection was not necessary in the majority of cases. 3D-US brings the diagnostics of uterine anomalies back into the hands of the gynecologist and can provide the gynecological surgeon with a higher subjective degree of certainty during operative hysteroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates a novel method which allows clutter elimination in deep optoacoustic imaging. Clutter significantly limits imaging depth in clinical optoacoustic imaging, when irradiation optics and ultrasound detector are integrated in a handheld probe for flexible imaging of the human body. Strong optoacoustic transients generated at the irradiation site obscure weak signals from deep inside the tissue, either directly by propagating towards the probe, or via acoustic scattering. In this study we demonstrate that signals of interest can be distinguished from clutter by tagging them at the place of origin with localised tissue vibration induced by the acoustic radiation force in a focused ultrasonic beam. We show phantom results where this technique allowed almost full clutter elimination and thus strongly improved contrast for deep imaging. Localised vibration tagging by means of acoustic radiation force is especially promising for integration into ultrasound systems that already have implemented radiation force elastography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a case where multi-phase post-mortem computed tomography angiography (PMCTA) induced a hemorrhagic pericardial effusion during the venous phase of angiography. Post-mortem non-contrast CT (PMCT) suggested the presence of a ruptured aortic dissection. This diagnosis was confirmed by PMCTA after pressure controlled arterial injection of contrast. During the second phase of multi-phase PMCTA the presence of contrast leakage from the inferior cava vein into the pericardial sac was noted. Autopsy confirmed the post-mortem nature of this vascular tear. This case teaches us an important lesson: it underlines the necessity to critically analyze PMCT and PMCTA images in order to distinguish between artifacts, true pathologies and iatrogenic findings. In cases with ambiguous findings such as the case reported here, correlation of imaging findings with autopsy is elementary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue just as is common in echo ultrasound. We demonstrate in three-dimensional simulations, phantom experiments, and in vivo mouse experiments that for vascular imaging this interpretation is often inaccurate. The cylindrical blood vessels emit anisotropic acoustic transients, which can be sensitively detected only if the direction of acoustic radiation coincides with the probe aperture. Our results reveal for this reason that the signal amplitude of different blood vessels may differ even if the vessels have the same diameter and initial pressure distribution but different orientation relative to the imaging plane. This has important implications for the image interpretation, for the probe guidance technique, and especially in cases when a quantitative reconstruction of the optical tissue properties is required.