904 resultados para Inorganic UV filter
Resumo:
Stratospheric ozone can be measured accurately using a limb scatter remote sensing technique at the UV-visible spectral region of solar light. The advantages of this technique includes a good vertical resolution and a good daytime coverage of the measurements. In addition to ozone, UV-visible limb scatter measurements contain information about NO2, NO3, OClO, BrO and aerosols. There are currently several satellite instruments continuously scanning the atmosphere and measuring the UVvisible region of the spectrum, e.g., the Optical Spectrograph and Infrared Imager System (OSIRIS) launched on the Odin satellite in February 2001, and the Scanning Imaging Absorption SpectroMeter for Atmospheric CartograpHY (SCIAMACHY) launched on Envisat in March 2002. Envisat also carries the Global Ozone Monitoring by Occultation of Stars (GOMOS) instrument, which also measures limb-scattered sunlight under bright limb occultation conditions. These conditions occur during daytime occultation measurements. The global coverage of the satellite measurements is far better than any other ozone measurement technique, but still the measurements are sparse in the spatial domain. Measurements are also repeated relatively rarely over a certain area, and the composition of the Earth’s atmosphere changes dynamically. Assimilation methods are therefore needed in order to combine the information of the measurements with the atmospheric model. In recent years, the focus of assimilation algorithm research has turned towards filtering methods. The traditional Extended Kalman filter (EKF) method takes into account not only the uncertainty of the measurements, but also the uncertainty of the evolution model of the system. However, the computational cost of full blown EKF increases rapidly as the number of the model parameters increases. Therefore the EKF method cannot be applied directly to the stratospheric ozone assimilation problem. The work in this thesis is devoted to the development of inversion methods for satellite instruments and the development of assimilation methods used with atmospheric models.
Resumo:
Avui en dia són diverses les llengües que lluiten per colonitzar la cibersocietat a la xarxa , i el català s'hi està forjant un paper gens menyspreable. Josep Gifreu repassa, en una investigació a cavall entre l'assaig històric cultural i la crònica política, l'evolució del procés general de normalització lingüística alhora que descriu el canvi en l'ecosistema mediàtic durant el període 1976-2013: des de la publicació del diari Avui fins a la Galàxia Internet , la revolució radical que , en el nostre cas, ha implicat la incorporació de la versió catalana a Google, l'aparició del domini .cat, la publicació del diari Ara , els més de 400.000 articles de la Viquipèdia o, per contra, el tancament de RTVV.
Resumo:
A method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were carried out against calibration solutions prepared in ethanol. Recovery tests were made in seven commercial ethanol fuel samples with values between 90 and 120%. Limits of detection were 0.1 µg L-1 for Cd and 0.3 µg L-1 for Pb. Certified water samples (APS 1071, APS 1033, NIST 1643d, NIST 1640) were also used to evaluate accuracy and recoveries from 86.8% to115% were obtained.
Resumo:
The microbiological bioassay, UV-spectrophotometry and HPLC methods for assaying gatifloxacin in tablets were compared. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. Beer's law was obeyed in the ranges 4.0-14.0 μg/mL for HPLC and UV-spectrophotometric method, and 4.0-16.0 μg/mL for bioassay. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The bioassay and HPLC are more specific than UV-spectrophotometric analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.
Resumo:
This paper describes the development and validation of an UV-Visible spectrophotometric method for quantitation of genistein and genistin in soy dry extracts, after reaction with aluminum chloride. The method showed to be linear (r²= 0.9999), precise (R.S.D. < 2%), accurate (recovery of 101.56%) and robust. Seven samples of soy dry extracts were analyzed by the spectrophotometric validated method and by RP-HPLC. Genistein concentrations determined by spectrophotometry (0.63% - 16.05%) were slightly higher than values obtained by HPLC analysis (0.40% - 12.79%); however, the results of both methods showed a strong correlation.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.
Resumo:
The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.
Resumo:
This research work aimed at determining the UVA effectiveness (UVA I/UV ratio), by diffuse transmittance analysis, of sunscreens developed with a bioactive substance, the rutin, associating or not with organic UVB-UVA filters incorporated at a phosphate-base O/W emulsion. Sunscreens provided conflicting and unpredictable results concerning the anti-UVA protection, specially, at the UVA I region. Possible interactions among the organic UV filters and the polyphenolic bioactive substance may have accounted with improvement or reduction of UV protection by a complex and not yet elucidated mechanism, probably regarding wavelength delocalization to superior or inferior values, by resonant molecule stabilization or destabilization.
Resumo:
A spectrophotometric method was proposed for Ni(II) determination in alloys using a dopa-semiquinone (L-1) to form [Ni(II)(L1-)3]1-, ε = 9.3 x 10³ L mol-1 cm-1. The optimal conditions for the determination were: wavelength 590 nm, temperature 25 °C, reaction time 45 min and pH 7.5. The Beer's law was obeyed for nickel from 3.33 x 10-5 to 1.78 x 10-4 mol L-1. The method was applied to complex samples, such as inox, nickel-titanium and cobalt-chromium alloys. A study of the potential interferents revealed that Mn was the major interferent. The limit of detection and quantification were 2.88 x 10-5 mol L-1 and 3.06 x 10-5 mol L-1, respectively.
Resumo:
A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.
Resumo:
A simple, robust, versatile, high analytical frequency method was proposed to check if a sample of wine is within the range of standards set by the manufacturer, using the UV-VIS spectroscopy, multivariate analysis and a flow-batch analyzer. Two hundred and fifty-two samples of wines were analyzed. The results from the application of Hierachical Cluster Analysis (HCA) to the matrix of the data involving all samples show the formation of fifteen types of wine. A Soft Independent Modelling of Class Analogy (SIMCA) model was constructed and used to classify the samples of the overall forecast. As a result, it is observed that the prediction was performed with a success rate of 99.2% for a confidence level of 95%. This shows that the proposed methodology can be used as an effective tool for classifying of samples of wines.
Resumo:
This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.
Resumo:
Food industries employ a lot of synthetic dyes in their products. Most of these dyes are very stable face to the conventional treatments. This work studied the use of advanced oxidation process (AOP) as an alternative to the conventional ones to degrade a synthetic food effluent (photolysis and UV/H2O2 in continuous reactor). The more efficient process was the UV/H2O2 and it presented decoloration and degradation energetic efficiency values equal to 30.775 kWh m-3 and 269.909 kWh m-3, respectively. The color reduction was 96.4% and COD decrease was 38.56%.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.
Resumo:
The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.