938 resultados para INDOOR


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, most individuals spend about 80% of their time indoor and, consequently, the exposure to the indoor environment becomes more relevant than to the outdoor one. Children spend most of their time at home and at school and evaluations of their indoor environment are important for the time-weighted exposure. Due to their airways still in development, children are a sensitive group with higher risk than adults. Larger impact in health and educational performance of children demand indoor air quality studies of schools. The aim of this study was to assess the children exposure to bioaerosols. A methodology based upon passive sampling was applied to evaluate fungi, bacteria and pollens; its procedures and applicability was optimized. An indoor air study by passive sampling represents an easier and cheaper method when comparing with the use of automatic active samplers. Furthermore, it is possible to achieve important quality information without interfering in the classroom activities. The study was conducted in three schools, representative of different environments in the Lisbon urban area, at three different periods of the year to obtain a seasonal variation, to estimate the variability through the city and to understand the underneath causes. Fungi and bacteria were collected indoor and outdoor of the classrooms to determine the indoor/outdoor ratios and to assess the level of outdoor contamination upon the indoor environment. The children's exposure to pollen grains inside the classrooms was also assessed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Com este trabalho pretende-se estudar o desempenho das tecnologias GSM-R e WiMAX em ambientes ferroviários. Este tipo de estudo tem uma importância elevada devido grande interesse na reestruturação dos sistemas de comunicações vocacionados para aplicações ferroviárias. Estes sistemas são cada vez mais complexos, apresentando níveis mais elevados de exigência, como a segurança, suporte de sinalização, tráfego ferroviário e interoperabilidade entre sistemas de diferentes países. Com tudo isto é necessário explorar e conhecer o comportamento de diversas tecnologias para este tipo de aplicações. Neste trabalho foi efectuado um primeiro estudo abrangendo a tecnologia WiMAX (Norma IEEE 802.16d) em ambientes interiores de edifícios, de forma a estudar o seu comportamento com e sem linha de vista e em proximidade e afastamento da estação base. Este estudo foi conclusivo quanto há não adequação desta tecnologia em ambientes ferroviários, visto ter sido observado que em situações de ausência de linha de vista a degradação da qualidade do sinal não conseguiria suportar os níveis de exigência necessários para a aplicação do mesmo em ambientes ferroviários. Analisou-se em segundo lugar a tecnologia GSM-R, onde se efectuou um estudo de campo em ambientes reais. Para o estudo desta tecnologia foram utilizados ambientes diversificados de forma a obter um estudo mais aprofundado do seu comportamento. Como objectivo têm-se a criação de melhores métodos de planeamento, mais vocacionados para as características específicas dos ambientes ferroviários e exigências das aplicações dos sistemas de comunicações ferroviários. Através deste estudo foi possível obter conclusões relativamente à variação da potência do sinal para as diversas condições e ambientes de propagação a que o sistema GSM-R foi sujeito, tendo sido possível também caracterizar o tipo de ambientes característicos das linhas ferroviárias. Foi possível também concluir que este tipo de sistemas consegue responder aos níveis de exigência e aplicações dos sistemas de comunicação ferroviários, trazendo uma mais-valia relativamente aos existentes actualmente a nível nacional.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório de estágio, que se realizou no Edifício Atrium Saldanha em Lisboa, tem por finalidade demonstrar as aptidões adquiridas no decorrer do Mestrado e que tornaram possíveis a participação num estágio que envolveu várias áreas da Engenharia Mecânica. Nos últimos anos, tem-se assistido a um crescente aumento do consumo e do custo da energia eléctrica. De acordo com análises realizadas pela União Europeia, uma percentagem significativa deste aumento de consumo está relacionado com edifícios e habitações. A manutenção preventiva das instalações técnicas é, entre outros aspectos, uma das ferramentas essenciais na redução desta factura energética. A questão que se coloca relaciona-se com a metodologia a aplicar para esse efeito. De que forma podem ou devem os planos de manutenção ser elaborados, qual a periodicidade das intervenções a considerar de modo a aumentar a eficiência energética dos edifícios, reduzir as emissões de dióxido de carbono e garantir uma maior protecção do utilizador? Numa fase inicial do estágio foi feita uma caracterização geral das principais instalações técnicas do edifício de modo a se analisarem, posteriormente, os procedimentos de manutenção adoptados pelas equipas de manutenção. Foram ainda sugeridas algumas periodicidades para os procedimentos de manutenção já existentes e algumas intervenções que não estavam incluídas no plano de manutenção do edifício e que podem contribuir para aumentar a fiabilidade dos equipamentos e consequentemente a eficiência energética e a qualidade do ar interior dos edifícios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Environmental tobacco smoke (ETS) is recognized as an occupational hazard in the hospitality industry. Although Portuguese legislation banned smoking in most indoor public spaces, it is still allowed in some restaurants/bars, representing a potential risk to the workers’ health, particularly for chronic respiratory diseases. The aims of this work were to characterize biomarkers of early genetic effects and to disclose proteomic signatures associated to occupational exposure to ETS and with potential to predict respiratory diseases development. A detailed lifestyle survey and clinical evaluation (including spirometry) were performed in 81 workers from Lisbon restaurants. ETS exposure was assessed through the level of PM 2.5 in indoor air and the urinary level of cotinine. The plasma samples were immunodepleted and analysed by 2D-SDSPAGE followed by in-gel digestion and LC-MS/MS. DNA lesions and chromosome damage were analysed innlymphocytes and in exfoliated buccal cells from 19 cigarette smokers, 29 involuntary smokers, and 33 non-smokers not exposed to tobacco smoke. Also, the DNA repair capacity was evaluated using an ex vivo challenge comet assay with an alkylating agent (EMS). All workers were considered healthy and recorded normal lung function. Interestingly, following 2D-DIGE-MS (MALDI-TOF/TOF), 61 plasma proteins were found differentially expressed in ETS-exposed subjects, including 38 involved in metabolism, acute-phase respiratory inflammation, and immune or vascular functions. On the other hand, the involuntary smokers showed neither an increased level of DNA/chromosome damage on lymphocytes nor an increased number of micronuclei in buccal cells, when compared to non-exposed non-smokers. Noteworthy, lymphocytes challenge with EMS resulted in a significantly lower level of DNA breaks in ETS-exposed as compared to non-exposed workers (P<0.0001) suggestive of an adaptive response elicited by the previous exposure to low levels of ETS. Overall, changes in proteome may be promising early biomarkers of exposure to ETS. Likewise, alterations of the DNA repair competence observed upon ETS exposure deserves to be further understood. Work supported by Fundação Calouste Gulbenkian, ACSS and FCT/Polyannual Funding Program.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 μm2/cm3, which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) μm have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 μm2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to contribute to the assessment of exposure levels of ultrafine particles (UFP) in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung-deposited alveolar surface area (resulting from exposure to UFP) in a major avenue leading to the town centre during late Spring, as well as in indoor buildings facing it. This study revealed differentiated patterns for week days and weekends, consistent with PM(2.5) and PM(10) patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels could be directly related with the fluxes of automobile traffic. During a typical week, UFP alveolar deposited surface area varied between 35.0 and 89.2 µm(2)/cm(3), which is comparable with levels reported for other towns such in Germany and United States. The measured values allowed the determination of the number of UFP per cm(3), which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32-63%) outdoor, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the management of solid waste, pollutants over a wide range are released with different routes of exposure for workers. The potential for synergism among the pollutants raises concerns about potential adverse health effects, and there are still many uncertainties involved in exposure assessment. In this study, conventional (culture-based) and molecular real-time polymerase chain reaction (RTPCR) methodologies were used to assess fungal air contamination in a waste-sorting plant which focused on the presence of three potential pathogenic/toxigenic fungal species: Aspergillus flavus, A. fumigatus, and Stachybotrys chartarum. In addition, microbial volatile organic compounds (MVOC) were measured by photoionization detection. For all analysis, samplings were performed at five different workstations inside the facilities and also outdoors as a reference. Penicillium sp. were the most common species found at all plant locations. Pathogenic/toxigenic species (A. fumigatus and S. chartarum) were detected at two different workstations by RTPCR but not by culture-based techniques. MVOC concentration indoors ranged between 0 and 8.9 ppm (average 5.3 ± 3.16 ppm). Our results illustrated the advantage of combining both conventional and molecular methodologies in fungal exposure assessment. Together with MVOC analyses in indoor air, data obtained allow for a more precise evaluation of potential health risks associated with bioaerosol exposure. Consequently, with this knowledge, strategies may be developed for effective protection of the workers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aflatoxin B1 (AFB1) has been recognized to produce cancer in human liver. In addition, epidemiological and laboratory studies demonstrated that the respiratory system was a target for AFB1. Exposure occurs predominantly through the food chain, but inhalation represents an additional route of exposure. The present study aimed to examine AFB1 exposure among poultry workers in Portugal. Blood samples were collected from a total of 31 poultry workers from six poultry farms. In addition, a control group (n = 30) was included comprised of workers who undertook administrative tasks. Measurement of AFB1 in serum was performed by enzyme-linked immunosorbent assay (ELISA). For examining fungi contamination, air samples were collected through an impaction method. Air sampling was obtained in pavilion interior and outside the premises, since this was the place regarded as the reference location. Using molecular methods, toxicogenic strains (aflatoxin-producing) were investigated within the group of species belonging to Aspergillus flavus complex. Eighteen poultry workers (59%) had detectable levels of AFB1 with values ranging from <1 ng/ml to4.23 ng/ml and with a mean value of 2 ± 0.98ng/ml. AFB1 was not detected in the serum sampled from any of the controls. Aspergillus flavus was the fungal species third most frequently found in the indoor air samples analyzed (7.2%) and was the most frequently isolated species in air samples containing only Aspergillus genus (74.5%). The presence of aflatoxigenic strains was only confirmed in outdoor air samples from one of the units, indicating the presence of a source inside the building in at least one case. Data indicate that AFB1 inhalation represents an additional risk in this occupational setting that needs to be recognized, assessed, and prevented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The production of MVOC by fungi has been taken into account especially from the viewpoint of indoor pollution with microorganisms but the relevance of fungal metabolites in working environments has not been sufficiently studied. The purpose of this study was to assess exposure to MVOCs in a waste-handling unit. It was used Multirae equipment (RAE Systems) to measured MVOCs concentration with a 10.6 eV lamps. The measurements were done near workers nose and during the normal activities. All measurements were done continuously and had the duration of 5 minutes at least. It was consider the higher value obtained in each measurement. In addition, for knowing fungi contamination, five air samples of 50 litres were collected through impaction method at 140 L/minute, at one meter tall, on to malt extract agar with the antibiotic chloramphenicol (MEA). MVOCs results range between 4.7 ppm and 8.9 ppm in the 6 locations consider. These results are eight times higher than normally obtained in indoor settings. Considering fungi results, two species were identified in air, being the genera Penicillium found in all the samples in uncountable colonies and Rhizopus only in one sample (40 UFC/m3). These fungi are known as MVOCs producers, namely terpenoids, ketones, alcohols and others. Until now, there has been no evidence that MVOCs are toxicologically relevant, but further epidemiological research is necessary to elucidate their role on human’s health, particularly in occupational settings where microbiological contamination is common. Additionally, further research should concentrate on quantitative analyses of specific MVOCs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho consiste em avaliar as capacidades das femto-células, no âmbito do planeamento e otimização de redes Universal Mobile Telecommunication System (UMTS) instaladas no interior de edifícios num ambiente empresarial. A avaliação será feita através do estudo da tecnologia das femto-células, e do planeamento efetuado num cenário real onde, através do desenvolvimento e teste de um conjunto parametrizações, será avaliado o funcionamento das femto-células assim como forma de otimizar o seu desempenho. O estudo realizado permitiu identificar um conjunto de características que as femto-células partilham com as Self-Organizing Networks (SON), como a auto-configuração, auto-otimização de parâmetros rádio, ajuste dinâmico da área de cobertura, atribuição automática de Scrambling Codes (SC) e da frequência da portadora, criação automática de relações de vizinhança, entre outras, que permitem facilitar o processo de planeamento e otimização de redes móveis UMTS. Recorrendo a um cenário empresarial real, foi efetuado um planeamento celular indoor de raiz, através do qual foi possível testar o funcionamento da algumas das principais funções das femto-células, nomeadamente a capacidade de ajuste dinâmico da área de cobertura. Foi também avaliado o funcionamento de um grupo co-localizado de femto-células, onde foi possível testar parametrizações com o objetivo de melhorar o processo de handover entre as femto-células do grupo, e entre estas e a rede macro Global System for Mobile Communications (GSM). A avaliação de cada um de cada uma das parametrizações testada, é efetuada a partir das medidas recolhidas no terreno, recorrendo à ferramenta TEMS® Investigation, assim como aos Key Performance Indicators (KPIs) que as femto-células disponibilizam. Os resultados obtidos mostram o benefício da utilização das femto-células num ambiente empresarial real, assim como os eventuais problemas e desafios que podem surguir do planeamento celular indoor recorrendo à tecnologia das femto-células, sendo apresentada a parametrização que permite obter o melhor desempenho da rede instalada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poor air quality in a pig-confinement building may potentially place farmers at higher health risk than other workers for exposure to airborne pollutants that may reach infectious levels. The aim of this study was to assess worker exposure to fungi in indoor environments in Portuguese swine buildings. Air samples from 7 swine farms were collected at a flow rate of 140 L/min, at 1 m height, onto malt extract agar supplemented with chloramphenicol (MEA). Surfaces samples of the same indoor sites were obtained by swabbing the surfaces. Samples from the floor covering were also collected from four of seven swine farms. All collected samples were incubated at 27°C for 5-7 days. After lab processing and incubation of obtained samples, quantitative colony-forming units (CFU)/m(3), CFU/cm(2), and CFU/g and qualitative results were determined with identification of isolated fungal species. Aspergillus versicolor was the most frequent species found in air (21%), followed by Scopulariopsis brevicaulis (17%) and Penicillium sp. (14%). Aspergillus versicolor was also the most frequent species noted on surfaces (26.6%), followed by Cladosporium sp. (22.4%) and Scopulariopsis brevicaulis (17.5%). Chrysosporium was the most frequently found genera in the new floor covering (38.5%), while Mucor was the most prevalent genera (25.1%) in used floor covering. Our findings corroborate a potential occupational health threat due to fungi exposure and suggest the need for a preventive strategy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several studies have shown that human exposures to airbome dust and microorganisms, such as bacteria and fungi, can cause respiratory diseases. Agricultural workers have been found to be at high risk of exposures to airborne particles. From a human health perspective dust exposure in pig farming is the most important risk because of the large number of workers needed in pig production and the increasing number of working hours inside enclosed buildings. In the pig buildings, particulate matters like dust play a role in not only deteriorating indoor air quality but also can cause an adverse health effect on workers. Generally, dust is recognized to adsorb and transport odorous compounds and biological agents. The aim of this study was to determine particles contamination in 7 swine farms located in Lisbon district, Portugal.