970 resultados para High-bias breaking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

While increasing numbers of young high school students engage in part-time work, there is no consensus about its impact on educational outcomes. Indeed this field has had a dearth of research. The present paper presents a review of recent research, primarily from Australia and the US, although it is acknowledged that there are considerable contextual differences. Suggestions for school counsellors to harness the students’ experiences to assist in educational and career decision-making are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods. Retrospective data from a tear film study using basic high-speed videokeratoscopy, captured at 25 frames per second, (Kopf et al., 2008, J Optom) were used. Eleven subjects had tear film analysis conducted in the morning, midday and evening on the first and seventh day of one week of no lens wear. Five of the eleven subjects then completed an extra week of hydrogel lens wear followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6 second period of the inter-blink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance due to shadows from the eyelashes. A value of tear film surface quality was derived using image rocessing techniques, based on the quality of the reflected ring pattern orientation. Results. The group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than previous methods (average reduction of about 92%). Bare eye measurements from the right and left eyes of eleven individuals showed high correlation values (Pearson’s correlation r = 0.73, p < 0.05). Repeated measures ANOVA across the 6 second period of measurement in the normal inter-blink period for the bare eye condition showed no statistically significant changes. However, across the 6 second inter-blink period with both contact lenses, statistically significant changes were observed (p < 0.001) for both types of contact lens material. Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with the bare eye condition (repeated measures ANOVA, p < 0.0001 for both hydrogel and silicone hydrogel). Conclusions. The results suggest that the dynamic-area method of high-speed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for noninvasive assessment of tear film surface quality (TFSQ) is proposed. The method is based on high-speed videokeratoscopy in which the corneal area for the analysis is dynamically estimated in a manner that removes videokeratoscopy interference from the shadows of eyelashes but not that related to the poor quality of the precorneal tear film that is of interest. The separation between the two types of seemingly similar videokeratoscopy interference is achieved by region-based classification in which the overall noise is first separated from the useful signal (unaltered videokeratoscopy pattern), followed by a dedicated interference classification algorithm that distinguishes between the two considered interferences. The proposed technique provides a much wider corneal area for the analysis of TFSQ than the previously reported techniques. A preliminary study with the proposed technique, carried out for a range of anterior eye conditions, showed an effective behavior in terms of noise to signal separation, interference classification, as well as consistent TFSQ results. Subsequently, the method proved to be able to not only discriminate between the bare eye and the lens on eye conditions but also to have the potential to discriminate between the two types of contact lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-speed videokeratoscopy is an emerging technique that enables study of the corneal surface and tear-film dynamics. Unlike its static predecessor, this new technique results in a very large amount of digital data for which storage needs become significant. We aimed to design a compression technique that would use mathematical functions to parsimoniously fit corneal surface data with a minimum number of coefficients. Since the Zernike polynomial functions that have been traditionally used for modeling corneal surfaces may not necessarily correctly represent given corneal surface data in terms of its optical performance, we introduced the concept of Zernike polynomial-based rational functions. Modeling optimality criteria were employed in terms of both the rms surface error as well as the point spread function cross-correlation. The parameters of approximations were estimated using a nonlinear least-squares procedure based on the Levenberg-Marquardt algorithm. A large number of retrospective videokeratoscopic measurements were used to evaluate the performance of the proposed rational-function-based modeling approach. The results indicate that the rational functions almost always outperform the traditional Zernike polynomial approximations with the same number of coefficients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the challenges of transfer of training back to the workplace for programme and project managers who are being groomed for the leadership of large and complex projects. The paper draws on the experience of the development and delivery of Queensland University of Technology (QUT) education programs: an Executive Masters of Complex Project Management and a series of Continuing Professional Development (CPD) events for an Australian government agency, Defence Materiel Organisation (DMO). Drawing on notions of ‘far transfer’ (Laker 1990; Noe, 1986) and ‘transfer climate’ (Kozlowski & Salas, 1993; Yamnill & McLean, 2001), the paper describes the steps undertaken to achieve a design that ensures that programme and project leadership skills developed through these corporate education programs become successfully embedded back in the organisation. Further, the paper reports on a small qualitative study where the programme success was evaluated by the organisational sponsor, senior leaders and program participants. Nine interviews were conducted and analysed to identify the success of far transfer and transfer climate four months after the return of program participants from cohort 1 2008 to the workplace.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The international focus on embracing daylighting for energy efficient lighting purposes and the corporate sector’s indulgence in the perception of workplace and work practice “transparency” has spurned an increase in highly glazed commercial buildings. This in turn has renewed issues of visual comfort and daylight-derived glare for occupants. In order to ascertain evidence, or predict risk, of these events; appraisals of these complex visual environments require detailed information on the luminances present in an occupant’s field of view. Conventional luminance meters are an expensive and time consuming method of achieving these results. To create a luminance map of an occupant’s visual field using such a meter requires too many individual measurements to be a practical measurement technique. The application of digital cameras as luminance measurement devices has solved this problem. With high dynamic range imaging, a single digital image can be created to provide luminances on a pixel-by-pixel level within the broad field of view afforded by a fish-eye lens: virtually replicating an occupant’s visual field and providing rapid yet detailed luminance information for the entire scene. With proper calibration, relatively inexpensive digital cameras can be successfully applied to the task of luminance measurements, placing them in the realm of tools that any lighting professional should own. This paper discusses how a digital camera can become a luminance measurement device and then presents an analysis of results obtained from post occupancy measurements from building assessments conducted by the Mobile Architecture Built Environment Laboratory (MABEL) project. This discussion leads to the important realisation that the placement of such tools in the hands of lighting professionals internationally will provide new opportunities for the lighting community in terms of research on critical issues in lighting such as daylight glare and visual quality and comfort.