945 resultados para Estimator standard error and efficiency
Resumo:
[EN]The age and growth of the sand sole Pegusa lascaris from the Canarian Archipelago were studied from 2107 fish collected between January 2005 and December 2007. To find an appropriate method for age determination, sagittal otoliths were observed by surface-reading and frontal section and the results were compared. The two methods did not differ significantly in estimated age but the surface-reading method is superior in terms of cost and time efficiency. The sand sole has a moderate life span, with ages up to 10 years recorded. Individuals grow quickly in their first two years, attaining approximately 48% of their maximum standard length; after the second year, their growth rate drops rapidly as energy is diverted to reproduction. Males and females show dimorphism in growth, with females reaching a slightly greater length and age than males. Von Bertalanffy, seasonalized von Bertalanfy, Gompertz, and Schnute growth models were fitted to length-at-age data. Akaike weights for the seasonalized von Bertalanffy growth model indicated that the probability of choosing the correct model from the group of models used was >0.999 for males and females. The seasonalized von Bertalanffy growth parameters estimated were: L? = 309 mm standard length, k = 0.166 yr?1, t0 = ?1.88 yr, C = 0.347, and ts = 0.578 for males; and L? = 318 mm standard length, k = 0.164 yr?1, t0 = ?1.653 yr, C = 0.820, and ts = 0.691 for females. Fish standard length and otolith radius are closely correlated (R2 = 0.902). The relation between standard length and otolith radius is described by a power function (a = 85.11, v = 0.906)
Resumo:
[EN] Marine N2 fixing microorganisms, termed diazotrophs, are a key functional group in marine pelagic ecosystems. The biological fixation of dinitrogen (N2) to bioavailable nitrogen provides an important new source of nitrogen for pelagic marine ecosystems 5 and influences primary productivity and organic matter export to the deep ocean. As one of a series of efforts to collect biomass and rates specific to different phytoplankton functional groups, we have constructed a database on diazotrophic organisms in the global pelagic upper ocean by compiling about 12 000 direct field measurements of cyanobacterial diazotroph abundances (based on microscopic cell counts or qPCR 10 assays targeting the nifH genes) and N2 fixation rates. Biomass conversion factors are estimated based on cell sizes to convert abundance data to diazotrophic biomass. The database is limited spatially, lacking large regions of the ocean especially in the Indian Ocean. The data are approximately log-normal distributed, and large variances exist in most sub-databases with non-zero values differing 5 to 8 orders of magnitude. 15 Lower mean N2 fixation rate was found in the North Atlantic Ocean than the Pacific Ocean. Reporting the geometric mean and the range of one geometric standard error below and above the geometric mean, the pelagic N2 fixation rate in the global ocean is estimated to be 62 (53–73) TgNyr−1 and the pelagic diazotrophic biomass in the global ocean is estimated to be 4.7 (2.3–9.6) TgC from cell counts and to 89 (40–20 200) TgC from nifH-based abundances. Uncertainties related to biomass conversion factors can change the estimate of geometric mean pelagic diazotrophic biomass in the global ocean by about ±70 %. This evolving database can be used to study spatial and temporal distributions and variations of marine N2 fixation, to validate geochemical estimates and to parameterize and validate biogeochemical models. The database is 25 stored in PANGAEA (http://doi.pangaea.de/10.1594/PANGAEA.774851).
Resumo:
[EN] Confluence of anthropogenic influences is common in coastal areas (e.g., disposal of different pollutants like industrial and domestic sewage, brine, etc.). In this study we assessed whether the combined disposal of domestic sewage and brine altered patterns in the abundance and assemblage structure of subtidal meiofauna inhabiting sandy seabeds. Samples were collected in May 2008 and January 2009 at varying distances (0, 15, and 30 m) from the discharge point. Meiofaunal abundances were consistently larger at 0 m (1663.05 ± 1076.86 ind 10 cm?2, mean ± standard error) than at 15 m (471.21 ± 307.97 ind 10 cm?2) and 30 m (316.50 ± 256.85 ind 10 cm?2) from the discharge outfall. This pattern was particularly accentuated for nematodes. Proximity to the discharge point also altered patterns in meiofaunal assemblage structure, though temporal shifts in the sedimentary composition also contributed to explain differences in the meiofaunal assemblage structure. As a result, meiofauna may be a reliable tool for monitoring studies of the combined disposal of sewage and brine as long as potential confounding factors (here temporal changes in grain size composition) are considered.
Resumo:
This work is structured as follows: In Section 1 we discuss the clinical problem of heart failure. In particular, we present the phenomenon known as ventricular mechanical dyssynchrony: its impact on cardiac function, the therapy for its treatment and the methods for its quantification. Specifically, we describe the conductance catheter and its use for the measurement of dyssynchrony. At the end of the Section 1, we propose a new set of indexes to quantify the dyssynchrony that are studied and validated thereafter. In Section 2 we describe the studies carried out in this work: we report the experimental protocols, we present and discuss the results obtained. Finally, we report the overall conclusions drawn from this work and we try to envisage future works and possible clinical applications of our results. Ancillary studies that were carried out during this work mainly to investigate several aspects of cardiac resynchronization therapy (CRT) are mentioned in Appendix. -------- Ventricular mechanical dyssynchrony plays a regulating role already in normal physiology but is especially important in pathological conditions, such as hypertrophy, ischemia, infarction, or heart failure (Chapter 1,2.). Several prospective randomized controlled trials supported the clinical efficacy and safety of cardiac resynchronization therapy (CRT) in patients with moderate or severe heart failure and ventricular dyssynchrony. CRT resynchronizes ventricular contraction by simultaneous pacing of both left and right ventricle (biventricular pacing) (Chapter 1.). Currently, the conductance catheter method has been used extensively to assess global systolic and diastolic ventricular function and, more recently, the ability of this instrument to pick-up multiple segmental volume signals has been used to quantify mechanical ventricular dyssynchrony. Specifically, novel indexes based on volume signals acquired with the conductance catheter were introduced to quantify dyssynchrony (Chapter 3,4.). Present work was aimed to describe the characteristics of the conductancevolume signals, to investigate the performance of the indexes of ventricular dyssynchrony described in literature and to introduce and validate improved dyssynchrony indexes. Morevoer, using the conductance catheter method and the new indexes, the clinical problem of the ventricular pacing site optimization was addressed and the measurement protocol to adopt for hemodynamic tests on cardiac pacing was investigated. In accordance to the aims of the work, in addition to the classical time-domain parameters, a new set of indexes has been extracted, based on coherent averaging procedure and on spectral and cross-spectral analysis (Chapter 4.). Our analyses were carried out on patients with indications for electrophysiologic study or device implantation (Chapter 5.). For the first time, besides patients with heart failure, indexes of mechanical dyssynchrony based on conductance catheter were extracted and studied in a population of patients with preserved ventricular function, providing information on the normal range of such a kind of values. By performing a frequency domain analysis and by applying an optimized coherent averaging procedure (Chapter 6.a.), we were able to describe some characteristics of the conductance-volume signals (Chapter 6.b.). We unmasked the presence of considerable beat-to-beat variations in dyssynchrony that seemed more frequent in patients with ventricular dysfunction and to play a role in discriminating patients. These non-recurrent mechanical ventricular non-uniformities are probably the expression of the substantial beat-to-beat hemodynamic variations, often associated with heart failure and due to cardiopulmonary interaction and conduction disturbances. We investigated how the coherent averaging procedure may affect or refine the conductance based indexes; in addition, we proposed and tested a new set of indexes which quantify the non-periodic components of the volume signals. Using the new set of indexes we studied the acute effects of the CRT and the right ventricular pacing, in patients with heart failure and patients with preserved ventricular function. In the overall population we observed a correlation between the hemodynamic changes induced by the pacing and the indexes of dyssynchrony, and this may have practical implications for hemodynamic-guided device implantation. The optimal ventricular pacing site for patients with conventional indications for pacing remains controversial. The majority of them do not meet current clinical indications for CRT pacing. Thus, we carried out an analysis to compare the impact of several ventricular pacing sites on global and regional ventricular function and dyssynchrony (Chapter 6.c.). We observed that right ventricular pacing worsens cardiac function in patients with and without ventricular dysfunction unless the pacing site is optimized. CRT preserves left ventricular function in patients with normal ejection fraction and improves function in patients with poor ejection fraction despite no clinical indication for CRT. Moreover, the analysis of the results obtained using new indexes of regional dyssynchrony, suggests that pacing site may influence overall global ventricular function depending on its relative effects on regional function and synchrony. Another clinical problem that has been investigated in this work is the optimal right ventricular lead location for CRT (Chapter 6.d.). Similarly to the previous analysis, using novel parameters describing local synchrony and efficiency, we tested the hypothesis and we demonstrated that biventricular pacing with alternative right ventricular pacing sites produces acute improvement of ventricular systolic function and improves mechanical synchrony when compared to standard right ventricular pacing. Although no specific right ventricular location was shown to be superior during CRT, the right ventricular pacing site that produced the optimal acute hemodynamic response varied between patients. Acute hemodynamic effects of cardiac pacing are conventionally evaluated after stabilization episodes. The applied duration of stabilization periods in most cardiac pacing studies varied considerably. With an ad hoc protocol (Chapter 6.e.) and indexes of mechanical dyssynchrony derived by conductance catheter we demonstrated that the usage of stabilization periods during evaluation of cardiac pacing may mask early changes in systolic and diastolic intra-ventricular dyssynchrony. In fact, at the onset of ventricular pacing, the main dyssynchrony and ventricular performance changes occur within a 10s time span, initiated by the changes in ventricular mechanical dyssynchrony induced by aberrant conduction and followed by a partial or even complete recovery. It was already demonstrated in normal animals that ventricular mechanical dyssynchrony may act as a physiologic modulator of cardiac performance together with heart rate, contractile state, preload and afterload. The present observation, which shows the compensatory mechanism of mechanical dyssynchrony, suggests that ventricular dyssynchrony may be regarded as an intrinsic cardiac property, with baseline dyssynchrony at increased level in heart failure patients. To make available an independent system for cardiac output estimation, in order to confirm the results obtained with conductance volume method, we developed and validated a novel technique to apply the Modelflow method (a method that derives an aortic flow waveform from arterial pressure by simulation of a non-linear three-element aortic input impedance model, Wesseling et al. 1993) to the left ventricular pressure signal, instead of the arterial pressure used in the classical approach (Chapter 7.). The results confirmed that in patients without valve abnormalities, undergoing conductance catheter evaluations, the continuous monitoring of cardiac output using the intra-ventricular pressure signal is reliable. Thus, cardiac output can be monitored quantitatively and continuously with a simple and low-cost method. During this work, additional studies were carried out to investigate several areas of uncertainty of CRT. The results of these studies are briefly presented in Appendix: the long-term survival in patients treated with CRT in clinical practice, the effects of CRT in patients with mild symptoms of heart failure and in very old patients, the limited thoracotomy as a second choice alternative to transvenous implant for CRT delivery, the evolution and prognostic significance of diastolic filling pattern in CRT, the selection of candidates to CRT with echocardiographic criteria and the prediction of response to the therapy.
Resumo:
In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.
Resumo:
Visual search and oculomotor behaviour are believed to be very relevant for athlete performance, especially for sports requiring refined visuo-motor coordination skills. Modern coaches believe that a correct visuo-motor strategy may be part of advanced training programs. In this thesis two experiments are reported in which gaze behaviour of expert and novice athletes were investigated while they were doing a real sport specific task. The experiments concern two different sports: judo and soccer. In each experiment, number of fixations, fixation locations and mean fixation duration (ms) were considered. An observational analysis was done at the end of the paper to see perceptual differences between near and far space. Purpose: The aim of the judo study was to delineate differences in gaze behaviour characteristics between a population of athletes and one of non athletes. Aspects specifically investigated were: search rate, search order and viewing time across different conditions in a real-world task. The second study was aimed at identifying gaze behaviour in varsity soccer goalkeepers while facing a penalty kick executed with instep and inside foot. Then an attempt has been done to compare the gaze strategies of expert judoka and soccer goalkeepers in order to delineate possible differences related to the different conditions of reacting to events occurring in near (peripersonal) or far (extrapersonal) space. Judo Methods: A sample of 9 judoka (black belt) and 11 near judoka (white belt) were studied. Eye movements were recorded at 500Hz using a video based eye tracker (EyeLink II). Each subject participated in 40 sessions for about 40 minutes. Gaze behaviour was considered as average number of locations fixated per trial, the average number of fixations per trial, and mean fixation duration. Soccer Methods: Seven (n = 7) intermediate level male volunteered for the experiment. The kickers and goalkeepers, had at least varsity level soccer experience. The vision-in-action (VIA) system (Vickers 1996; Vickers 2007) was used to collect the coupled gaze and motor behaviours of the goalkeepers. This system integrated input from a mobile eye tracking system (Applied Sciences Laboratories) with an external video of the goalkeeper’s saving actions. The goalkeepers took 30 penalty kicks on a synthetic pitch in accordance with FIFA (2008) laws. Judo Results: Results indicate that experts group differed significantly from near expert for fixations duration, and number of fixations per trial. The expert judokas used a less exhaustive search strategy involving fewer fixations of longer duration than their novice counterparts and focused on central regions of the body. The results showed that in defence and attack situation expert group did a greater number of transitions with respect to their novice counterpart. Soccer Results: We found significant main effect for the number of locations fixated across outcome (goal/save) but not for foot contact (instep/inside). Participants spent more time fixating the areas in instep than inside kick and in goal than in save situation. Mean and standard error in search strategy as a result of foot contact and outcome indicate that the most gaze behaviour start and finish on ball interest areas. Conclusions: Expert goalkeepers tend to spend more time in inside-save than instep-save penalty, differences that was opposite in scored penalty kick. Judo results show that differences in visual behaviour related to the level of expertise appear mainly when the test presentation is continuous, last for a relatively long period of time and present a high level of uncertainty with regard to the chronology and the nature of events. Expert judoist performers “anchor” the fovea on central regions of the scene (lapel and face) while using peripheral vision to monitor opponents’ limb movements. The differences between judo and soccer gaze strategies are discussed on the light of physiological and neuropsychological differences between near and far space perception.
Resumo:
In this work we develop and analyze an adaptive numerical scheme for simulating a class of macroscopic semiconductor models. At first the numerical modelling of semiconductors is reviewed in order to classify the Energy-Transport models for semiconductors that are later simulated in 2D. In this class of models the flow of charged particles, that are negatively charged electrons and so-called holes, which are quasi-particles of positive charge, as well as their energy distributions are described by a coupled system of nonlinear partial differential equations. A considerable difficulty in simulating these convection-dominated equations is posed by the nonlinear coupling as well as due to the fact that the local phenomena such as "hot electron effects" are only partially assessable through the given data. The primary variables that are used in the simulations are the particle density and the particle energy density. The user of these simulations is mostly interested in the current flow through parts of the domain boundary - the contacts. The numerical method considered here utilizes mixed finite-elements as trial functions for the discrete solution. The continuous discretization of the normal fluxes is the most important property of this discretization from the users perspective. It will be proven that under certain assumptions on the triangulation the particle density remains positive in the iterative solution algorithm. Connected to this result an a priori error estimate for the discrete solution of linear convection-diffusion equations is derived. The local charge transport phenomena will be resolved by an adaptive algorithm, which is based on a posteriori error estimators. At that stage a comparison of different estimations is performed. Additionally a method to effectively estimate the error in local quantities derived from the solution, so-called "functional outputs", is developed by transferring the dual weighted residual method to mixed finite elements. For a model problem we present how this method can deliver promising results even when standard error estimator fail completely to reduce the error in an iterative mesh refinement process.
Resumo:
One of the ways by which the legal system has responded to different sets of problems is the blurring of the traditional boundaries of criminal law, both procedural and substantive. This study aims to explore under what conditions does this trend lead to the improvement of society's welfare by focusing on two distinguishing sanctions in criminal law, incarceration and social stigma. In analyzing how incarceration affects the incentive to an individual to violate a legal standard, we considered the crucial role of the time constraint. This aspect has not been fully explored in the literature on law and economics, especially with respect to the analysis of the beneficiality of imposing either a fine or a prison term. We observed that that when individuals are heterogeneous with respect to wealth and wage income, and when the level of activity can be considered a normal good, only the middle wage and middle income groups can be adequately deterred by a fixed fines alone regime. The existing literature only considers the case of the very poor, deemed as judgment proof. However, since imprisonment is a socially costly way to deprive individuals of their time, other alternatives may be sought such as the imposition of discriminatory monetary fine, partial incapacitation and other alternative sanctions. According to traditional legal theory, the reason why criminal law is obeyed is not mainly due to the monetary sanctions but to the stigma arising from the community’s moral condemnation that accompanies conviction or merely suspicion. However, it is not sufficiently clear whether social stigma always accompanies a criminal conviction. We addressed this issue by identifying the circumstances wherein a criminal conviction carries an additional social stigma. Our results show that social stigma is seen to accompany a conviction under the following conditions: first, when the law coincides with the society's social norms; and second, when the prohibited act provides information on an unobservable attribute or trait of an individual -- crucial in establishing or maintaining social relationships beyond mere economic relationships. Thus, even if the social planner does not impose the social sanction directly, the impact of social stigma can still be influenced by the probability of conviction and the level of the monetary fine imposed as well as the varying degree of correlation between the legal standard violated and the social traits or attributes of the individual. In this respect, criminal law serves as an institution that facilitates cognitive efficiency in the process of imposing the social sanction to the extent that the rest of society is boundedly rational and use judgment heuristics. Paradoxically, using criminal law in order to invoke stigma for the violation of a legal standard may also serve to undermine its strength. To sum, the results of our analysis reveal that the scope of criminal law is narrow both for the purposes of deterrence and cognitive efficiency. While there are certain conditions where the enforcement of criminal law may lead to an increase in social welfare, particularly with respect to incarceration and stigma, we have also identified the channels through which they could affect behavior. Since such mechanisms can be replicated in less costly ways, society should first try or seek to employ these legal institutions before turning to criminal law as a last resort.
Resumo:
The Standard Model of elementary particle physics was developed to describe the fundamental particles which constitute matter and the interactions between them. The Large Hadron Collider (LHC) at CERN in Geneva was built to solve some of the remaining open questions in the Standard Model and to explore physics beyond it, by colliding two proton beams at world-record centre-of-mass energies. The ATLAS experiment is designed to reconstruct particles and their decay products originating from these collisions. The precise reconstruction of particle trajectories plays an important role in the identification of particle jets which originate from bottom quarks (b-tagging). This thesis describes the step-wise commissioning of the ATLAS track reconstruction and b-tagging software and one of the first measurements of the b-jet production cross section in pp collisions at sqrt(s)=7 TeV with the ATLAS detector. The performance of the track reconstruction software was studied in great detail, first using data from cosmic ray showers and then collisions at sqrt(s)=900 GeV and 7 TeV. The good understanding of the track reconstruction software allowed a very early deployment of the b-tagging algorithms. First studies of these algorithms and the measurement of the b-tagging efficiency in the data are presented. They agree well with predictions from Monte Carlo simulations. The b-jet production cross section was measured with the 2010 dataset recorded by the ATLAS detector, employing muons in jets to estimate the fraction of b-jets. The measurement is in good agreement with the Standard Model predictions.
Resumo:
The present thesis focuses on the problem of robust output regulation for minimum phase nonlinear systems by means of identification techniques. Given a controlled plant and an exosystem (an autonomous system that generates eventual references or disturbances), the control goal is to design a proper regulator able to process the only measure available, i.e the error/output variable, in order to make it asymptotically vanishing. In this context, such a regulator can be designed following the well known “internal model principle” that states how it is possible to achieve the regulation objective by embedding a replica of the exosystem model in the controller structure. The main problem shows up when the exosystem model is affected by parametric or structural uncertainties, in this case, it is not possible to reproduce the exact behavior of the exogenous system in the regulator and then, it is not possible to achieve the control goal. In this work, the idea is to find a solution to the problem trying to develop a general framework in which coexist both a standard regulator and an estimator able to guarantee (when possible) the best estimate of all uncertainties present in the exosystem in order to give “robustness” to the overall control loop.
Resumo:
PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.
Resumo:
Complete basis set and Gaussian-n methods were combined with Barone and Cossi's implementation of the polarizable conductor model (CPCM) continuum solvation methods to calculate pKa values for six carboxylic acids. Four different thermodynamic cycles were considered in this work. An experimental value of −264.61 kcal/mol for the free energy of solvation of H+, ΔGs(H+), was combined with a value for Ggas(H+) of −6.28 kcal/mol, to calculate pKa values with cycle 1. The complete basis set gas-phase methods used to calculate gas-phase free energies are very accurate, with mean unsigned errors of 0.3 kcal/mol and standard deviations of 0.4 kcal/mol. The CPCM solvation calculations used to calculate condensed-phase free energies are slightly less accurate than the gas-phase models, and the best method has a mean unsigned error and standard deviation of 0.4 and 0.5 kcal/mol, respectively. Thermodynamic cycles that include an explicit water in the cycle are not accurate when the free energy of solvation of a water molecule is used, but appear to become accurate when the experimental free energy of vaporization of water is used. This apparent improvement is an artifact of the standard state used in the calculation. Geometry relaxation in solution does not improve the results when using these later cycles. The use of cycle 1 and the complete basis set models combined with the CPCM solvation methods yielded pKa values accurate to less than half a pKa unit. © 2001 John Wiley & Sons, Inc. Int J Quantum Chem, 2001
Resumo:
Complete Basis Set and Gaussian-n methods were combined with CPCM continuum solvation methods to calculate pKa values for six carboxylic acids. An experimental value of −264.61 kcal/mol for the free energy of solvation of H+, ΔGs(H+), was combined with a value for Ggas(H+) of −6.28 kcal/mol to calculate pKa values with Cycle 1. The Complete Basis Set gas-phase methods used to calculate gas-phase free energies are very accurate, with mean unsigned errors of 0.3 kcal/mol and standard deviations of 0.4 kcal/mol. The CPCM solvation calculations used to calculate condensed-phase free energies are slightly less accurate than the gas-phase models, and the best method has a mean unsigned error and standard deviation of 0.4 and 0.5 kcal/mol, respectively. The use of Cycle 1 and the Complete Basis Set models combined with the CPCM solvation methods yielded pKa values accurate to less than half a pKa unit.
Resumo:
In addition to particle size and surface chemistry, the shape of particles plays an important role in their wetting and displacement by the surfactant film in the lung. The role of particle shape was the subject of our investigations using a model system consisting of a modified Langmuir-Wilhelmy surface balance. We measured the influence of sharp edges (lines) and other highly curved surfaces, including sharp corners or spikes, of different particles on the spreading of a dipalmitoylphosphatidyl (DPPC) film. The edges of cylindrical sapphire plates (circular curved edges, 1.65 mm radius) were wetted at a surface tension of 10.7 mJ/m2 (standard error (SE) = 0.45, n = 20) compared with that of 13.8 mJ/m2 (SE = 0.20, n = 20) for cubic sapphire plates (straight linear edges, edge length 3 mm) (p < 0.05). The top surfaces of the sapphire plates (cubic and cylindrical) were wetted at 8.4 mJ/m2 (SE = 0.54, n = 20) and 9.1 mJ/m2 (SE = 0.50, n = 20), respectively, but the difference was not significant (p > 0.05). The surfaces of the plates showed significantly higher resistance to spreading compared to that of the edges, as substantially lower surface tensions were required to initiate wetting (p < 0.05). Similar results were found for talc particles, were the edges of macro- and microcrystalline particles were wetted at 7.2 mJ/m2 (SE = 0.52, n = 20) and 8.2 mJ/m2 (SE = 0.30, n = 20) (p > 0.05), respectively, whereas the surfaces were wetted at 3.8 mJ/m2 (SE = 0.89, n = 20) and 5.8 mJ/m2 (SE = 0.52, n = 20) (p < 0.05), respectively. Further experiments with pollen of malvaceae and maize (spiky and fine knobbly surfaces) were wetted at 10.0 mJ/m2 (SE = 0.52, n = 10) and 22.75 mJ/m2 (SE = 0.81, n = 10), respectively (p < 0.05). These results show that resistance to spreading of a DPPC film on various surfaces is dependent on the extent these surfaces are curved. This is seen with cubic sapphire plates which have at their corners a radius of curvature of about 0.75 microm, spiky malvaceae pollen with an even smaller radius on top of their spikes, or talc with various highly curved surfaces. These highly curved surfaces resisted wetting by the DPPC film to a higher degree than more moderately curved surfaces such as those of cylindrical sapphire plates, maize pollens, or polystyrene spheres, which have a surface free energy similar to that of talc but a smooth surface. The macroscopic plane surfaces of the particles demonstrated the greatest resistance to spreading. This was explained by the extremely fine grooves in the nanometer range, as revealed by electron microscopy. In summary, to understand the effects of airborne particles retained on the surfaces of the respiratory tract, and ultimately their pathological potential, not only the particle size and surface chemistry but also the particle shape should be taken in consideration.
Resumo:
OBJECTIVES: Biologic effects of high homeopathic potencies can be studied in cell cultures using cell lines or primary cells. We hypothesized that primary cells would be more apt to respond to high potencies than cell lines, especially cancer cell lines. We set out to investigate the effects of low doses and high homeopathic potencies of cadmium chloride, respectively, in an intoxication model with human primary lymphocytes compared to a human leukemia cell line (Jurkat). DESIGN: Cells were pretreated with either low concentrations (nM-microM) or high potencies (pool 15-20c) of cadmium for 120 hours, following which they were exposed to a toxic treatment with a range of cadmium concentrations (8-80 microM) during 24 hours. Cell viability was eventually assessed by use of the MTS/PES assay. Controls included a vehicle (NaCl 0.9%) for the low concentrations of cadmium or water 15-20c for cadmium 15-20c. A total of 34 experiments were conducted, 23 with low concentrations and 11 with high potencies of cadmium. Data were analyzed by analysis of variance. RESULTS: Pretreatment with low concentrations or high potencies of cadmium significantly increased cell viability in primary lymphocytes after toxic challenge, compared to control cells (mean effect +/- standard error = 19% +/- 0.9% for low concentrations respectively 8% +/- 0.6% for high potencies of cadmium; p < 0.001 in both cases). The pretreatment effect of low doses was significant also in cancerous lymphocytes (4% +/- 0.5%; p < 0.001), albeit weaker than in normal lymphocytes. However, high homeopathic potencies had no effect on cancerous lymphocytes (1% +/- 1.9%; p = 0.45). CONCLUSIONS: High homeopathic potencies exhibit a biologic effect on cell cultures of normal primary lymphocytes. Cancerous lymphocytes (Jurkat), having lost the ability to respond to regulatory signals, seem to be fairly unresponsive to high homeopathic potencies.