902 resultados para Dormant fault segment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate and compare the biocompatibility of two types of Ferrara intracorneal ring segment: with and without chondroitin sulfate coating by clinical and histopathological evaluation. METHODS: A randomized experimental study was carried out on thirty right-eye corneas from 30 Norfolk albino rabbits allocated into two experimental groups: Group G1 - implanted with Ferrara intracorneal ring segment without coating (FICRS) and Group G2 - implanted with Ferrara intracorneal ring segment with chondroitin sulfate coating (FICRS-CS). Left eyes formed the control group. Clinical parameters analyzed were: presence of edema, vascularization, infection and ring extrusion one, 30, and 60 days after surgery. Histopathological parameters analyzed were: number of corneal epithelial layers over and adjacent to the ring, presence of spongiosis, hydropic degeneration, basement membrane thinning, inflammatory cells, neovascularization and pseudocapsule formation. RESULTS: At clinical examination 60 days after implant, edema, vascularization and extrusion were observed respectively in 20%, 26.7%, 6.7% of FICRS corneas and in 6.7%, 6.7%, and 0% of FICRS-CS corneas. Histopathological evaluation showed epithelial-layer reduction from 5 (5;6) to 3 (3;3) with FICRS and from 5 (5;5) to 4 (3;5) with FICRS-CS in the region over the ring. Epithelial spongiosis, hydropic degeneration, and basement membrane thinning were present in 69.2%, 53.8%, and 69.2% of FICRS and in 73.3%, 73.3%, and 46.7% with FICRS-CS, respectively. Vascularization was present in 38.5% of FICRS and 13.3% with FICRS-CS, inflammatory cells in 75% of FICRS and 33.3% with FICRS-CS, and pseudocapsule in 66.7% of FICRS and 93.3% with FICRS-CS. Giant cells occurred only in the FICRS-CS group (20%). CONCLUSION: Ferrara intracorneal rings coated with chondroitin sulfate (FICRS-CS) caused lower frequency of clinical and histopathological alterations than Ferrara intracorneal rings without the coating (FICRS), demonstrating higher biocompatibility of the FICRS-CS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Grupo Tucuruí de idade do final do Neoproterozoico aflora na região de Tucuruí, nordeste do Pará, ao longo da zona de transição entre o Cráton Amazônico e o Cinturão Araguaia, e constitui uma sucessão vulcanossedimentar contendo derrames basálticos e sills de diabásio intercalados com depósitos siliciclásticos. A Falha de Tucuruí, por cavalgamento, projetou estes conjuntos rochosos para oeste, resultando em cisalhamento e percolação de fluidos. Os depósitos siliciclásticos são constituídos por subarcóseos e siltitos amalgamados, cujas camadas orientam-se na direção NNE-SSW com mergulho baixo para SE, além de apresentar granocrescência e espessamento ascendente. Foram reconhecidas duas associações de fácies sedimentares: depósitos de antepraia e tempestitos de face litorânea. Estas associações de fáceis sugerem processos de transporte e sedimentação ligados a um ambiente marinho raso, seguindo da zona de foreshore até a zona de shoreface, sob influência de onda de tempestade. A análise petrográfica revelou a imaturidade textural e composicional dos arenitos e siltitos arcosianos, indicando, sobretudo, área fonte com proveniência próxima, predominantemente constituída de rochas ígneas de composição máfica a intermediária que estiveram sujeitas a condições mesodiagenéticas. Assim, os depósitos siliciclásticos do Grupo Tucuruí representam a porção preservada de um segmento costeiro influenciado por ondas de tempestade em uma bacia do tipo rifte ou antepaís, com área fonte próxima, forte gradiente de relevo e deposição rápida, marcada predominantemente por intemperismo físico, e que foi atingida durante sua formação por vulcanismo efusivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Far from the continental margin, drainage basins in Central Amazonia should be in topographic steady state; but they are not. Abandoned remnant fluvial valleys up to hundreds of square kilometers in size are observed throughout Amazonia, and are evidence of significant landscape reorganization. While major Late Miocene drainage shifts occurred due to initiation of the transcontinental Amazon River, local landscape change has remained active until today. Driven either by dynamic topography, tectonism, and/or climatic fluctuations, drainage captures in Amazonia provide a natural experiment for assessing the geomorphic response of low-slope basins to sudden, capture related base-level falls. This paper evaluates the timing of geomorphic change by examining a drainage capture event across the Baependi fault scarp involving the Cuieiras and TarumA-Mirim River basins northwest of the city of Manaus in Brazil. A system of capture-related knickpoints was generated by base-level fall following drainage capture; through numerical modeling of their initiation and propagation, the capture event is inferred to have occurred between the middle and late Pleistocene, consistent with other studies of landscape change in surrounding areas. In low-slope settings like the Amazon River basin, base-level fall can increase erosion rates by more than an order of magnitude, and moderate to large river basins can respond to episodes of base-level fall over timescales of tens to hundreds of thousands of years. Copyright (c) 2013 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Omega resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm(3). Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resistive-type of superconducting fault current limiters (RSFCL) have been developed for medium voltage class aiming to operate at 1 MVA power capacity and short time recovery (< 2 s). A RSFCL in form of superconducting modular device was designed and constructed using 50 m-length of YBCO coated conductor tapes for operation under 1 kV / 1 kA and acting time of 0.1 s. In order to increase the acting time the RSFCL was combined with an air-core reactor in parallel to increase the fault limiting time up to 1 s. The tests determined the electrical and thermal characteristics of the combined resistive/ inductive protection unit. The combined fault current limiter reached a limiting current of 583 A, corresponding to a limiting factor of 3.3 times within an acting time of up to 1 s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The anatomosurgical segmentation of the arteries of the spleen was studied in 31 deer of the species Mazama gouazoubira and Blastocerus dichotomus by means of vascular injection with latex and vinyl acetate and radiographic examination. The arteria lienalis penetrated through the hilus lienis in 87% of the cases, whereas an extrahilar artery was present in the other cases. An extraparenchymal division of the lineal artery into two, three or four segmental arteries was observed in 74% of the cases. Anastomoses between intraparenchymal arterial branches were rare and of a reduced calibre.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protecting a network against link failures is a major challenge faced by network operators. The protection scheme has to address two important objectives - fast recovery and minimizing the amount of backup resources needed. Every protection algorithm is a tradeoff between these two objectives. In this paper, we study the problem of segment protection. In particular, we investigate what is the optimal segment size that obtains the best tradeoff between the time taken for recovery and minimizing the bandwidth used by the backup segments. We focus on the uniform fixed-length segment protection method, where each primary path is divided into fixed-length segments, with the exception of the last segment in the path. We observe that the optimal segment size for a given network depends on several factors such as the topology and the ratio of the costs involved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

End users develop more software than any other group of programmers, using software authoring devices such as e-mail filtering editors, by-demonstration macro builders, and spreadsheet environments. Despite this, there has been little research on finding ways to help these programmers with the dependability of their software. We have been addressing this problem in several ways, one of which includes supporting end-user debugging activities through fault localization techniques. This paper presents the results of an empirical study conducted in an end-user programming environment to examine the impact of two separate factors in fault localization techniques that affect technique effectiveness. Our results shed new insights into fault localization techniques for end-user programmers and the factors that affect them, with significant implications for the evaluation of those techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test case prioritization techniques schedule test cases for regression testing in an order that increases their ability to meet some performance goal. One performance goal, rate offault detection, measures how quickly faults are detected within the testing process. In previous work we provided a metric, APFD, for measuring rate of fault detection, and techniques for prioritizing test cases to improve APFD, and reported the results of experiments using those techniques. This metric and these techniques, however, applied only in cases in which test costs and fault severity are uniform. In this paper, we present a new metric for assessing the rate of fault detection of prioritized test cases, that incorporates varying test case and fault costs. We present the results of a case study illustrating the application of the metric. This study raises several practical questions that might arise in applying test case prioritization; we discuss how practitioners could go about answering these questions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an evolutionary computing strategy to solve the problem of fault indicator (FI) placement in primary distribution feeders. More specifically, a genetic algorithm (GA) is employed to search for an efficient configuration of FIs, located at the best positions on the main feeder of a real-life distribution system. Thus, the problem is modeled as one of optimization, aimed at improving the distribution reliability indices, while, at the same time, finding the least expensive solution. Based on actual data, the results confirm the efficiency of the GA approach to the FI placement problem.