846 resultados para Compliance frameworks
Resumo:
Experts working on behalf of international development organisations need better tools to assist land managers in developing countriesmaintain their livelihoods, as climate change puts pressure on the ecosystemservices that they depend upon. However, current understanding of livelihood vulnerability to climate change is based on a fractured and disparate set of theories andmethods. This reviewtherefore combines theoretical insights from sustainable livelihoods analysis with other analytical frameworks (including the ecosystem services framework, diffusion theory, social learning, adaptive management and transitions management) to assess the vulnerability of rural livelihoods to climate change. This integrated analytical framework helps diagnose vulnerability to climate change,whilst identifying and comparing adaptation options that could reduce vulnerability, following four broad steps: i) determine likely level of exposure to climate change, and how climate change might interact with existing stresses and other future drivers of change; ii) determine the sensitivity of stocks of capital assets and flows of ecosystem services to climate change; iii) identify factors influencing decisions to develop and/or adopt different adaptation strategies, based on innovation or the use/substitution of existing assets; and iv) identify and evaluate potential trade-offs between adaptation options. The paper concludes by identifying interdisciplinary research needs for assessing the vulnerability of livelihoods to climate change.
Resumo:
A retrospective study has been conducted examining the relationship between patient compliance and race among diagnosed hypertensives in NHANES II 1976-1980. The study includes the review/analysis of 403 blacks and 2,011 nonblacks. Patient compliance was measured using the frequency that patients took their hypertensive medication.^ A statistically significant trend of increasing compliance as age increased was found (p =.000) in blacks, nonblacks, and the study group. The number of times a person spoke with a doctor about high blood pressure was found to be statistically significant (p ==.000) in nonblacks and the study group. ^
Resumo:
The paper analyzes how to comply with an emission constraint, which restricts the use of an established energy technique, given the two options to save energy and to invest in two alternative energy techniques. These techniques differ in their deterioration rates and the investment lags of the corresponding capital stocks. Thus, the paper takes a medium-term perspective on climate change mitigation, where the time horizon is too short for technological change to occur, but long enough for capital stocks to accumulate and deteriorate. It is shown that, in general, only one of the two alternative techniques prevails in the stationary state, although, both techniques might be utilized during the transition phase. Hence, while in a static economy only one technique is efficient, this is not necessarily true in a dynamic economy.
Resumo:
Pressure-driven orbital reordering in the quantum magnet [CuF2(H2O)2- (pyz)], (pyz = pyrazine), dramatically affects its magnetic exchange interactions. The crystal chemistry of this system is enriched with a new phase above 3 GPa, surprisingly concomitant with other polymorphs. Moreover, we discovered an unprecedented compound with a different stoichiometry, [(CuF2(H2O)2)2(pyz)], featuring magnetic bi-layers.
Resumo:
OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
Resumo:
AIM To evaluate the compliance of cigarette smokers with scheduled visits for supportive periodontal therapy (SPT). MATERIALS AND METHODS Qualitative and quantitative analyses of compliance with scheduled SPT visits were performed using retrospective data from patients undergoing dental hygiene treatment at the Medi School of Dental Hygiene (MSDH), Bern, Switzerland 1985-2011. RESULTS A total of 1336 patients were identified with 32.1% (n = 429) being smokers, 23.1% (n = 308) former smokers and 44.8% (n = 599) non-smokers. Qualitatively, significantly less smokers returned for SPT than non-smokers or former smokers (p = 0.0026), whereas 25.9% (n = 346) never returned for SPT. Further quantitative analysis of patients returning twice or more (n = 883) revealed that the overall mean %-compliance was 69.8% (SD ±22.04),whereas smokers complied with 67.0% (SD ±22.00), former smokers with 69.7% (SD ±22.03), and non-smokers with 71.7% (SD ±21.92) reaching statistical significance (p = 0.0111). Confounder adjusted analysis, however, revealed that older age (p = 0.0001), female gender (p = 0.0058), longer SPT intervals (p < 0.0001) and higher severity of periodontal disease (p < 0.0001) had a much greater impact on %-compliance than smoking (p = 0.7636). CONCLUSIONS This study suggests that qualitatively, smokers return less likely for SPT than non-smokers or former smokers while quantitatively, a lower mean %-compliance of smokers attending scheduled SPT visits may be attributed to confounders.
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.
Resumo:
BACKGROUND Despite the chronic and relapsing nature of inflammatory bowel diseases (IBD), at least 30% to 45% of the patients are noncompliant to treatment. IBD patients often seek information about their disease. AIM To examine the association between information-seeking activity and treatment compliance among IBD patients. To compare information sources and concerns between compliant and noncompliant patients. METHODS We used data from the Swiss IBD cohort study, and from a qualitative survey conducted to assess information sources and concerns. Crude and adjusted odds ratios (OR) for noncompliance were calculated. Differences in the proportions of information sources and concerns were compared between compliant and noncompliant patients. RESULTS A total of 512 patients were included. About 18% (n = 99) of patients were reported to be noncompliant to drug treatment and two-thirds (n = 353) were information seekers. The OR for noncompliance among information seekers was 2.44 (95%CI: 1.34-4.41) after adjustment for confounders and major risk factors. General practitioners were 15.2% more often consulted (p = 0.019) among compliant patients, as were books and television (+13.1%; p = 0.048), whereas no difference in proportions was observed for sources such as internet or gastroenterologists. Information on tips for disease management were 14.2% more often sought among noncompliant patients (p = 0.028). No difference was observed for concerns on research and development on IBD or therapies. CONCLUSION In Switzerland, IBD patients noncompliant to treatment were more often seeking disease-related information than compliant patients. Daily management of symptoms and disease seemed to be an important concern of those patients.