947 resultados para Brake Wear.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relatively high elastic modulus coupled with the presence of toxic vanadium (V) in Ti6Al4 V alloy has long been a concern in orthopaedic applications. To solve the problem, a variety of non-toxic and low modulus beta-titanium (beta-Ti) alloys have been developed. Among the beta-Ti alloy family, the quaternary Ti-Nb-Zr-Ta (TNZT) alloys have received the highest attention as a promising replacement for Ti6Al4 V due to their lower elastic modulus and outstanding long term stability against corrosion in biological environments. However, the inferior wear resistance of TNZT is still a problem that must be resolved before commercialising in the orthopaedic market. In this work, a newly-developed laser surface treatment technique was employed to improve the surface properties of Ti-35.3Nb-7.3Zr-5.7Ta alloy. The surface structure and composition of the laser-treated TNZT surface were examined by grazing incidence x-ray diffraction (GI-XRD) and x-ray photoelectron spectroscopy (XPS). The wear and corrosion resistance were evaluated by pin-on-plate sliding test and anodic polarisation test in Hanks’ solution. The experimental results were compared with the untreated (or base) TNZT material. The research findings showed that the laser surface treatment technique reported in this work can effectively improve the wear and corrosion resistance of TNZT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study the prevalence and determinants of compliance with spectacle wear among school-age children in Oaxaca, Mexico, who were provided spectacles free of charge. METHODS: A cohort of 493 children aged 5 to 18 years chosen by random cluster sampling from primary and secondary schools in Oaxaca, Mexico, all of whom had received free spectacles through a local program, underwent unannounced, direct examination to determine compliance with spectacle wear within 18 months after initial provision of spectacles. Potential determinants of spectacle wear including age, gender, urban versus rural residence, presenting visual acuity, refractive error, and time since dispensing of the spectacles were examined in univariate and multivariate regression models. Children not currently wearing their spectacles were asked to select the reason from a list of possibilities, and reasons for noncompliance were analyzed within different demographic groups. RESULTS: Among this sample of children with a mean age of 10.4 +/- 2.6 years, the majority (74.5%) of whom were myopic (spherical equivalent [SE] < or = -0.50 D), 13.4% (66/493) were wearing their spectacles at the time of examination. An additional 34% (169/493) had the spectacles with them but were not wearing them. In regression models, the odds of spectacle wear were significantly higher among younger (OR = 1.19 per year of age; 95% CI, 1.05-1.33) rural (OR = 10.6; 95% CI, 5.3-21.0) children and those with myopia < or = -1.25 D (OR = 3.97; 95% CI, 1.98-7.94). The oldest children and children in urban-suburban areas were significantly more likely to list concerns about the appearance of the glasses or about being teased than were younger, rurally resident children. CONCLUSIONS: Compliance with spectacle wear may be very low, even when spectacles are provided free of charge, particularly among older, urban children, who have been shown in many populations to have the highest prevalence of myopia. As screening programs for refractive error become increasingly common throughout the world, new strategies are needed to improve compliance if program resources are to be maximized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study the effect of myopia and spectacle wear on bicycle-related injuries in rural Chinese students. Myopia is common among Chinese students but few studies have examined its effect on daily activities. METHODS: Data on visual acuity, refractive error, current spectacle wear, and history of bicycle use and accidents during the past 3 years were sought from 1891 students undergoing eye examinations in rural Guangdong province. RESULTS: Refractive and accident data were available for 1539 participants (81.3%), among whom the mean age was 14.6 years, 52.5% were girls, 26.8% wore glasses, and 12.9% had myopia of less than -4 diopters in both eyes. More than 90% relied on bicycles to get to school daily. A total of 2931 accidents were reported by 423 participants, with 68 requiring medical attention. Male sex (odds ratio, 1.55; P < .001) and spectacle wear (odds ratio, 1.38; P = .04) were associated with a higher risk of accident, but habitual visual acuity and myopia were unassociated with the crash risk, after adjusting for age, sex, time spent riding, and risky riding behaviors. CONCLUSION: These results may be consistent with data on motor vehicle accidents implicating peripheral vision (potentially compromised by spectacle wear) more strongly than central visual acuity in mediating crash risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thrust ball bearings lubricated with several different types of grease, including three biodegradable low-toxicity greases, were tested in a modified four-ball machine in order to evaluate the bearing friction torque. At the end of each test, grease samples were obtained and analysed through ferrography, allowing the quantification and evaluation of the bearing wear. In order to compare the grease performance in terms of friction and wear, a correlation between the grease characteristics (base oil, bleed oil, thickener structure, and rheological parameters) and the experimental results was established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abrasion by glass fibers during injection molding of fiber reinforced plastics raises new challenges to the wear performance of the molds. In the last few decades, a large number of PVD and CVD coatings have been developed with the aim of minimizing abrasion problems. In this work, two different coatings were tested in order to increase the wear resistance of the surface of a mold used for glass fiber reinforced plastics: TiAlSiN and CrN/CrCN/DLC. TiAlSiN was deposited as a graded monolayer coating while CrN/CrCN/DLC was a nanostructured coating consisting of three distinct layers. Both coatings were produced by PVD unbalanced magnetron sputtering and were characterized using scanning electron microscopy (SEM) provided with energy dispersive spectroscopy (EDS), atomic force microscopy (AFM), micro hardness (MH) and scratch test analysis. Coating morphology, thickness, roughness, chemical composition and structure, hardness and adhesion to the substrate were investigated. Wear resistance was characterized through industrial tests with coated samples and an uncoated reference sample inserted in a feed channel of a plastic injection mold working with 30 wt.% glass fiber reinforced polypropylene. Results after 45,000 injection cycles indicate that the wear resistance of the mold was increased by a factor of 25 and 58, by the TiAlSiN and CrN/CrCN/DLC coatings, respectively, over the uncoated mold steel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The injection process of glass fibres reinforced plastics promotes the moulds surface degradation by erosion. In order to improve its wear resistance, several kinds of PVD thin hard coatings were used. It is well-known that nanostructures present a better compromise between hardness and toughness. Indeed, when the coating is constituted by a large number of ultra-thin different layers, cracks and interface troubles tend to decrease. However, it is not clear that these nanostructures present a better wear behaviour in erosion processes. In order to study its wear behaviour, a sputtered PVD nanostructured TiAlCrSiN coating was used. The substrate and film surfaces topography were analyzed by profilometry and atomic force microscopy techniques. Film adhesion to the substrate was evaluated by scratch tests. The surface hardness was measured with a Vickers micro-hardness tester. The wear resistance was evaluated by micro-abrasion with a rotating ball tribometer tests. Slurry of SiC particles in distilled water was used in order to provoke the surface abrasion. Different duration tests were performed in order to analyze the wear evolution. After these tests, the wear mechanisms developed were analyzed by scanning electron microscopy. Wear craters were measured and the wear rate was calculated and discussed. With the same purpose, coated inserts were mounted in an injection mould working with a 30% glass fibres reinforced polypropylene. After 45 000 cycles no relevant wear was registered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A indústria automóvel necessita aumentar a produtividade de forma sistemática, com vista à redução de custos e incremento da competitividade. A otimização dos produtos e processos é uma constante. O presente trabalho foi solicitado pela empresa FicoCables, do Grupo FICOSA, tendo em vista a otimização do processo de injeção de pequenas peças injetadas em ZAMAK, que constituem o bloqueio na extremidade de cada cabo metálico inserido nos automóveis para abertura da mala, portas, travão de mão, reservatório de combustível, capô, etc. A empresa possui cerca de 52 equipamentos de injeção de ZAMAK, cuja temperatura dos bicos era mantida com base numa chama de gás. Os sucessivos problemas de controlo do sistema ditaram uma mudança estratégica no aquecimento desses bicos, passando a ser usadas resistências elétricas anelares. No entanto, esta mudança veio a apresentar problemas inesperados, os quais se vieram inclusivamente a tornar em problemas de segurança, devido ao desgaste interior prematuro dos bicos, os quais apresentaram esmo problema de rotura. Paralelamente, todos os parâmetros relacionados com este processo de fabrico estavam também estudados de forma algo incipiente, pelo que se tornou necessário compreender e dissecar todas as variáveis relacionadas com o processo e implementar sistemas que impedissem o ajuste não controlado dos parâmetros por parte dos operadores. Também os moldes foram alvo de ações de melhoria, com vista a evitar problemas na zona de contacto do bico com o molde. O processo foi analisado em pormenor, permitindo um controlo muito mais apurado do mesmo. Os resultados fizeram sentir-se de forma imediata, graças ao trabalho desenvolvido neste estudo e à abertura demonstrada pela empresa para implementar todas as soluções propostas. O resultado final traduz-se num incremento significativo da segurança para os operadores, num controlo muito mais apurado de todos os parâmetros envolvidos no processo, numa maior garantia da qualidade nos produtos injetados em ZAMAK e em ganhos financeiros significativos para a empresa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich). METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results. RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highlights from the creative presentation made to Lightning Fastener for the 1965 Womens Wear campaign.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tear and wear properties of short kevlar fiber, thermoplastic polcurethane (TPU) composite with respect to fiber loading-and fiber onentation has been studied and the fracture surfaces were examined under scanning electron microscope (SEM). Tear strength first decreased up to 20 phr fiber loading and then gradually increased with increasing fiber loading. Anisotropy in tear strength was evident beyond a fiber loading of 20 phr. Tear fracture surface of unfilled TPU showed sinusoidal folding characteristics of high strength matrix. At low fiber loading the tear failure was mainly due to fibermatrix failure whereas at higher fiber loading the failure occurred by fiber breakage. Abrasion loss shows a continuous rise with increasing fiber loading, the loss in the transverse orientation of fibers being higher than that in the longitudinal orientation. The abraded surface showed lone cracks and ridges parallel to the direction of abrasion indicating an abrasive wear mechanism. In the presence of fber the abrasion loss was mainly due to fiber low.