998 resultados para Acrylic resin denture teeth


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The organization of biofilms in the oral cavity gives them added resistance to antimicrobial agents. The action of phenothiazinic photosensitizers on oral biofilms has already been reported. However, the action of the malachite green photosensitizer upon biofilm-organized microorganisms has not been described. The objective of the present work was to compare the action of malachite green with the phenothiazinic photosensitizers (methylene blue and toluidine blue) on Staphylococcus aureus and Escherichia coli biofilms.Methods: The biofilms were grown on sample pieces of acrylic resin and subjected to photodynamic therapy using a 660-nm diode laser and photosensitizer concentrations ranging from 37.5 to 3000 mu M. After photodynamic therapy, cells from the biofilms were dispersed in a homogenizer and cultured in Brain Heart Infusion broth for quantification of colony-forming units per experimental protocol. For each tested microorganism, two control groups were maintained: one exposed to the laser radiation without the photosensitizer (L+PS-) and other treated with the photosensitizer without exposure to the red laser light (L-PS+). The results were subjected to descriptive statistical analysis.Results: The best results for S. aureus and E. coli biofilms were obtained with photosensitizer concentrations of approximately 300 mu M methylene blue, with microbial reductions of 0.8-1.0 log(10); 150 mu M toluidine blue, with microbial reductions of 0.9-1.0 log(10); and 3000 mu M malachite green, with microbial reductions of 1.6-4.0 log(10).Conclusion: Greater microbial reduction was achieved with the malachite green photosensitizer when used at higher concentrations than those employed for the phenothiazinic dyes. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). Methods: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried. The specimens were divided into two groups (N=20): 1-without neutralization; 2-with neutralization. All the restorations were silanized and adhesively cemented (self-curing and self-etching luting composite system, Multilink). Ten premolars from each group were submitted to mechanical cycling (1,400,000 cycles, 50N, 37 degrees C). After cycling, the samples were sectioned to produce non-trimmed beam specimens (vestibular dentin-restoration-lingual dentin set), which were submitted to microtensile testing. Results: Bond strength was significantly affected by the surface treatment (p<0.0001) (no neutralization > neutralization) and mechanical cycling (p<0.0001) (control > cycling) (2-way ANOVA and Tukey test, alpha=.05). Conclusion: Hydrofluoric acid precipitate neutralization appears to significantly damage the resin bond to glass-ceramic and should not be recommended. The clinical simulation of the specimens, by using mechanical cycling, is important when evaluating the ceramic-dentin bond.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the antimicrobial effectiveness and dental applications of ozonated water generated by portable equipment (0.667 mg/L). Total elimination of C. albicans, E. coli and S. mutans planktonic cells was observed after 5 min. Reduction in the number of viable cells of biofilms formed on acrylic resin was observed for C. albicans, S. mutans and E. coli. The same effect was observed on biofilms of E. coli, S. aureus, S. mutans and C. albicans formed on stainless steel. Ozonated water was effective for the disinfection of experimentally contaminated toothbrushes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram atendidos no Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Unesp - Campus de Botucatu, 11 animais (oito cães e três gatos), com alterações oftálmicas unilaterais graves que levaram à perda total da função ocular (protrusão de globo com injúria nervosa e estrutural, perfurações de córnea com perda de conteúdo intra-ocular e endoftalmites, entre outras). Os animais, com idades entre dois meses e 10 anos, foram submetidos à evisceração e posterior inclusão de esfera de resina acrílica (metilmetacrilato) na capa córneo-escleral ou escleral. As esferas foram previamente confeccionadas e esterilizadas por autoclavagem. No pós-operatório foram utilizados antiinflamatórios e antibioticoterapia tópica combinada ou não a sistêmica. O período de observação variou de 2 meses a 3 anos e os aspectos avaliados foram secreção ocular, blefarospasmo, sinais de desconforto e estética. Obtiveram-se resultados satisfatórios em oito casos. Concluiu-se que a resina acrílica pode ser uma alternativa para uso como inclusão em cavidade anoftálmica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dezoito coelhos, Norfolk, fêmeas, com 45 dias de idade foram divididos em três grupos de seis animais e submetidos a enucleação transpalpebral. Os animais do grupo I receberam na cavidade orbitaria acrílico auto-polimerizável, os do grupo II pericárdio eqüino conservado em glicerina e os do grupo III foram mantidos como controle. Para avaliação macroscópica e histopatológica das cavidades orbitarias, três animais de cada grupo foram sacrificados com 30 e 60 dias após a implantação. Apesar da resina ter sido aplicada na fase pastosa, na qual a alta temperatura que ocorre durante a polimerizaçâo pode ser lesiva aos tecidos, foi o produto que apresentou os melhores resultados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors studied the CREEP of 5 amalgam alloys (1 conventional and 4 with high cooper) by the application os static load of 36 MPa in 478 mm specimens, 7 days old. After CREEP test, the samples were included in acrylic resin and Vickers hardness determined by three penetrations for each portion (cervical, medium and occlusal). Samples not submitted to the creep test was used with control. They concluded that no statistic difference was found in creep test but in Vickers test all the studied materials showed different hardness averages. The load application to samples increased the hardness of all the studied materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fanconi anemia (FA) is a rare autosomal recessive disorder, characterized by pancytopenia and progressive hypoplasia of the bone marrow. A 23-year-old woman with FA showed severe pancytopenia and developed an abscess on the infraorbicular region on the right side of the face that progressed to phlegmon and caused tissue necrosis of the nostrils, nasal septum, nasal fossa, and posterior orbital region. Laboratory examination showed Streptococcus parasanguis as the etiologic agent of the phlegmon. Supportive treatment was recommended due to donor incompatibility for bone marrow transplant. The intraoral examination showed spontaneous gingival bleeding, edema of the interdental papillae, hematomas on the superior and inferior lips, bacterial and fungal infections, and adequate oral hygiene. The patient was treated with the administration of an antibiotic (imipenem), an antifungal (amphotericin B), and mouth washing with antiseptic solutions. Periodontal prophylaxis and orientation to and control of oral hygiene and diet were also used during the remission period. For functional and esthetic rehabilitation of the alar regions and nasal dorsum, an acrylic resin nasal prosthesis was made, supported by a spectacle frame.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V cast alloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3 groups (n=10) that received the following heat treatments: control (no heat treatment); treatment 1 (T1): heating at 750°C for 2 h; and treatment 2 (T2): annealing at 955°C for 1 h and aging at 620°C for 2 h. After heat treatments, the specimens were embedded in acrylic resin and their surface was ground and polished and hardness was measured. Vickers hardness means (VHN) and standard deviations were analyzed statistically by Kruskal-Wallis test at 5% significance level. For commercially pure titanium, Vickers hardness means of group T2 (259.90 VHN) was significantly higher than those of the other groups (control - 200.26 VHN and T1 - 202.23 VHN), which presented similar hardness means to each other (p>0.05). For Ti-6Al-4V alloy, statistically significant differences were observed among the three groups: T2 (369.08 VHN), T1 (351.94 VHN) and control (340.51 VHN) (p<0.05). The results demonstrated different hardness of CP Ti and Ti-6Al-4V when different heat treatments were used. For CP Ti, VHN means of T2 group was remarkably higher than those of control and T1 group, which showed similar VHN means to each other. For Ti-6Al-4V alloy, however, VHN means recorded for each group may be presented as follows: T2>T1>control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the skeletal muscle glycogen content and plasmatic concentration of interleukin -6 (IL-6), interleukin-4 (IL-4), interleukin-10 (IL-10) and tumor necrosis factor-alpha (TNF-α) in rats submitted to electrical stimulation sessions during the first three days of ankle immobilization at the position of 90°. Methods: Albinomale Wistar rats(3-4 months) were maintained in vivarium. conditions with food and water ad libitum, Submitted to 12 h photoperiodic cycles of light/dark, and distributed into 7 experimental groups (n = 6): control(C), immobilized 1 day(I1) immobilized 1 day and electrically stimulated(IE1) immobilized 2 days(12), immobilized 2 days and electrically stimulated(IE2), immobilized 3 days(13) and immobilized 3 days and electrically stimulated(IE3). Groups I utilized an acrylic resin orthesis model and groups electrically stimulated (IE) utilized the orthesis and a session of electrotherapy by a Dualpex 961 (biphasic quadratic pulse, 10 Hz, 0.4 ms, 5.0 mA, one 20 min session a day). After the experimental period, the rats were anesthetized with pentobarbital sodium(40 mg/kg) and a blood sample was colleted to evaluate the plasmatic concentration of interleukins by means of the radioimmunoassay method. The soleus and the white portion of the gastrocnemius muscle were colleted for glycogen reserves analysis(GLY). Other groups of rats were used to apply the glucose tolerance test(GTT) and insulin tolerance test(ITT). For statistical analysis, the Kolmogorov-Smirnov normality test followed by ANOVA and the Tukey tests were utilized, with a critical level established at 5%. Results: In ITT test, groups IE enhanced the skeletal muscle glucose uptake, but no changes were observed in GTT after the therapy session, which indicates that electrical stimulation is a sensibilizing method to augment skeletal muscle glucose uptake. The GLY reserves were reduced in I groups, which indicate that disuse altered insulin sensitivity and compromised energetic homeostasis. However. the IE groups displayed an augment in GLY content, suggesting that electrical stimulation restores the enzymatic pathways altered by immobilization. The improvement in GLY was accompanied by an elevation of the plasmatic concentration of IL-6 and TNF-α, showing the participation of these interleukins in the control of metabolic profile. Plasmatic concentrations of IL-10 were elevated only after 3 days of IE while IL-4 did not display any modifications. Conclusion: The results suggest that neuromuscular electricaf stimulation is an important toot in the maintenance of energetic, conditions of musculature submitted to immobilization, and presents multifactor mechanisms linked to interleukins action that converge to maintain the energetic equilibrium of the tissue in disuse.