428 resultados para ASTM
Resumo:
Corrosion is a relevant issue regarding the problem of biodiesel compatibility with polymers and metals. This work aims to evaluate the influence of the natural light incidence and temperature in the corrosion rate of brass and copper immersed in commercial biodiesel as well as biodiesel degradation after the contact with metallic ions. The characterization of corrosion behavior was performed by weight loss measurements according to ASTM G1 and ASTM G31. The experiments according to ASTM G1 were performed at room temperature in light presence and absence. Experiments were also conducted at 55 degrees C in order to compare with ASTM G31 that is also performed at that temperature. The biodiesel degradation was characterized by water content, oxidation stability, viscosity as well as XRF, IR and Raman spectroscopies. The results of ASTM G1 tests showed that the thickness loss for both metals determined at room temperature is slightly higher when there is light incidence and these values significantly decrease for the highest temperature. The results of ASTM G31 tests indicated that air bubbling along with higher temperature affects mostly immersed samples. Biodiesel in contact with metals shows significant degradation in its properties as evidenced by increasing water content, higher viscosity and lower oxidation stability. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The distribution of delta ferrite fraction was measured with the magnetic method in specimens of different stainless steel compositions cast by the investment casting (lost wax) process. Ferrite fraction measurements published in the literature for stainless steel cast samples were added to the present work data, enabling an extensive analysis about practical methods to calculate delta ferrite fractions in stainless steel castings. Nineteen different versions of practical methods were formed using Schaeffler, DeLong, and Siewert diagrams and the nickel and chromium equivalent indexes suggested by several authors. These methods were evaluated by a detailed statistical analysis, showing that the Siewert diagram, including its equivalent indexes and iso-ferrite lines, gives the lowest relative errors between calculated and measured delta ferrite fractions. Although originally created for stainless steel welds, this diagram gives relative errors lower than those for the current ASTM standard method (800/A 800M-01), developed to predict ferrite fractions in stainless steel castings. Practical methods originated from a combination of different chromium/nickel equivalent indexes and the iso-ferrite lines from Schaeffler diagram give the lowest relative errors when compared with combinations using other iso-ferrite line diagrams. For the samples cast in the present work, an increase in cooling rate from 0.78 to 2.7 K/s caused a decrease in the delta ferrite fraction, but a statistical hypothesis test revealed that this effect is significant in only 50% of the samples that have ferrite in their microstructures.
Resumo:
Duarte MAH, Alves de Aguiar K, Zeferino MA, Vivan RR, Ordinola-Zapata R, Tanomaru-Filho M, Weckwerth PH, Kuga MC. Evaluation of the propylene glycol association on some physical and chemical properties of mineral trioxide aggregate. International Endodontic Journal, 45, 565570, 2012. Abstract Aim To evaluate the influence of propylene glycol (PG) on the flowability, setting time, pH and calcium ion release of mineral trioxide aggregate (MTA). Methodology Mineral trioxide aggregate was mixed with different proportions of PG, as follows: group 1: MTA + 100% distilled water (DW); group 2: MTA + 80% DW and 20% PG; group 3: MTA + 50% DW and 50% PG; group 4: MTA + 20% DW and 80% PG; group 5: MTA + 100% PG. The ANSI/ADA No. 57 was followed for evaluating the flowability and the setting time was measured by using ASTM C266-08. For pH and calcium release analyses, 50 acrylic teeth with root-end cavities were filled with the materials (n = 10) and individually immersed in flasks containing 10 mL deionized water. After 3 h, 24 h, 72 h and 168 h, teeth were placed in new flasks and the water in which each specimen was immersed had its pH determined by a pH metre and the calcium release measured by an atomic absorption spectrophotometer with a calcium-specific hollow cathode lamp. Data were analysed by using one-way anova test for global comparison and by using Tukeys test for individual comparisons. Results The highest value of flowability was observed with MTA + 20% DW and 80% PG and the lowest values were found with MTA + 100% DW. They were significantly different compared to the other groups (P < 0.05). The presence of PG did not affect the pH and calcium release. The MTA + 100% PG favoured the highest (P < 0.05) pH and calcium release after 3 h. Increasing the PG proportion interfered (P < 0.05) with the setting time; when used at the volume of 100% setting did not occur. Conclusion The addition of PG to MTA-Angelus increased its setting time, improved flowability and increased the pH and calcium ion release during the initial post-mixing periods. The ratio of 80% DW 20% PG is recommended.
Resumo:
This work aimed to study the characteristics of the fibres of the species Bactris setosa ('tucum') used by close-knit social groups, located in Sorocaba - Sao Paulo - Brazil, in basket-making techniques, for possible applications in textile activity. Optical microscopy (NBR 13 538:1995) and Tensile Properties (ASTM D 3 822-2001) were used to assess properties such as the fibre structre, linear density, breaking force, elongation at break and breaking tenacity of each species. Bactris setosa showed a longitudinal view similar to that of sisal; an average linear density of 41.2 tex, a tenacity average of 11.96 cN/tex, closer to fiberglass, and an elongation ranging between 1.35 and 3.87%. It is important to clarify the delicacy and detail of the tests, and from this we highlight the importance of carrying out these studies, based on which science and technology must be linked with socio-environmental aspects.
Resumo:
The influence of test method factors (notch shape, square or angular, and pre-cracking method, by tapping onto or pressing a razor blade) on the results obtained in plane strain fracture toughness test according to standard ASTM D5045 using SENB specimens made of a commercial PMMA resin were investigated. Results were analyzed quantitatively by comparing the obtained K-IC values and qualitatively by observing their effect on the Moire fringes observed using photoelasticity, showing that, at 95% significance level, the K-IC values are affected by the pre-cracking method, with the most conservative value being obtained when natural pre-cracks were introduced by tapping onto a razor blade (K-IC = 1.15 +/- 0.11 MPa.m(0.5)). This correlates with a perturbation in the stress field close to the pre-crack tip observed in the photoelasticity test sample when it was introduced by pressing the razor blade. Surprisingly, notch geometry only slightly affects the results. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
In this work, multi-component white cast iron was applied by HVOF thermal spray process as alternative to other manufacture processes. Effects of substrate type, substrate pre-heating and heat treatment of coating on mass loss have been determined by rubber wheel apparatus in accordance with ASTM G-65. Furthermore, influence of heat treatment of coating on wear mechanisms was also determined by scanning electron microscopy analysis. Heat-treated coatings presented mass loss three times lower than as-sprayed coatings. Furthermore, wear mechanisms of as-sprayed coating are micro-cutting associated with cracks close to unmelted particles and pores. In heat-treated coating, lesser mass loss is due to sintering. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The influence of different Cr and C contents upon the solidification interval of ASTM A352M-06 Grade CA6NM cast martensitic stainless steel has been investigated using computational thermodynamics, and checked against DTA measurements in samples taken from 13 large cast parts, in order to identify potential sources for improvement on the part castability. Calculation results suggest, indeed, that this would be the case for C: when its content increases from 0.018 to 0.044 wt.% C (within the allowed range in the alloy specification), the solidification intervals increases from 25 to 43 K, which suggests improved castability with decreasing C contents. DTA results, however, do not support this prediction, showing a fairly constant solidification interval around 23 K for all investigated samples. The results are discussed both regarding the impact in alloy processing and the fitness of the existing databases to reproduce experimental results in these limiting cases.
Resumo:
Adequate polymerization plays an important role on the longevity of the composite resin restorations. Objectives: The aim of this study was to evaluate the effect of light-curing units, curing mode techniques and storage media on sorption, solubility and biaxial flexural strength (BFS) of a composite resin. Material and Methods: Two hundred and forty specimens were made of one composite resin (Esthet-X) in a stainless steel mold (2 mm x 8 mm 0), and divided into 24 groups (n=10) established according to the 4 study factors: light-curing units: quartz tungsten halogen (QTH) lamp and light-emitting diodes (LED); energy densities: 16 J/cm(2) and 20 J/cm(2); curing modes: conventional (CM) and pulse-delay (PD); and permeants: deionized water and 75% ethanol for 28 days. Sorption and solubility tests were performed according to ISO 4049:2000 specifications. All specimens were then tested for BFS according to ASTM F394-78 specification. Data were analyzed by three-way ANOVA followed by Tukey, Kruskal-Wallis and Mann-Whitney tests (alpha=0.05). Results: In general, no significant differences were found regarding sorption, solubility or BFS means for the light-curing units and curing modes (p>0.05). Only LED unit using 16 J/cm(2) and PD using 10 s produced higher sorption and solubility values than QTH. Otherwise, using CM (16 J/cm(2)), LED produced lower values of BFS than QTH (p<0.05). 75% ethanol permeant produced higher values of sorption and solubility and lower values of BFS than water (p<0.05). Conclusion: Ethanol storage media produced more damage on composite resin than water. In general the LED and QTH curing units using 16 and 20 J/cm(2) by CM and PD curing modes produced no influence on the sorption, solubility or BFS of the tested resin.
Resumo:
To evaluate the biocompatibility and the setting time of Portland cement clinker with or without 2% or 5% calcium sulfate and MTA-CPM. Twenty-four mice (Rattus norvegicus) received subcutaneously polyethylene tubes filled with Portland cement clinker with or without 2% or 5% calcium sulfate and MTA. After 15, 30 and 60 days of implantation, the animals were killed and specimens were prepared for microscopic analysis. For evaluation of the setting time, each material was analyzed using Gilmore needles weighing 113.5 g and 456.5 g, according to the ASTM specification Number C266-08 guideline. Data were analyzed by ANOVA and Tukey's test for setting time and Kruskal-Wallis and Dunn test for biocompatibility at 5% significance level. Histologic observation showed no statistically significant difference of biocompatibility (p>0.05) among the materials in the subcutaneous tissues. For the setting time, clinker without calcium sulfate showed the shortest initial and final setting times (6.18 s/21.48 s), followed by clinker with 2% calcium sulfate (9.22 s/25.33 s), clinker with 5% calcium sulfate (10.06 s/42.46 s) and MTA (15.01 s/42.46 s). All the tested materials showed biocompatibility and the calcium sulfate absence shortened the initial and final setting times of the white Portland cement clinker
Resumo:
La tecnica di ozonolisi viene applicata ai fanghi biologici derivanti da impianti di depurazione acque reflue urbane, e consiste nell'ottenere, grazie all'ozono, una minor massa fangosa da smaltire e una miglior trattabilità del fango residue. In questo elaborato si prendono in esame le sperimentazioni effettuate a Marina di Ravenna e si estraggono le prime conclusioni gestionali, economiche e ambientali sull'applicabilità del metodo a questo tipo di fango.
Resumo:
In questa tesi si è voluta porre l’attenzione sulla suscettibilità alle alte temperature delle resine che li compongono. Lo studio del comportamento alle alte temperature delle resine utilizzate per l’applicazione dei materiali compositi è risultato un campo di studio ancora non completamente sviluppato, nel quale c’è ancora necessità di ricerche per meglio chiarire alcuni aspetti del comportamento. L’analisi di questi materiali si sviluppa partendo dal contesto storico, e procedendo successivamente ad una accurata classificazione delle varie tipologie di materiali compositi soffermandosi sull’ utilizzo nel campo civile degli FRP (Fiber Reinforced Polymer) e mettendone in risalto le proprietà meccaniche. Considerata l’influenza che il comportamento delle resine riveste nel comportamento alle alte temperature dei materiali compositi si è, per questi elementi, eseguita una classificazione in base alle loro proprietà fisico-chimiche e ne sono state esaminate le principali proprietà meccaniche e termiche quali il modulo elastico, la tensione di rottura, la temperatura di transizione vetrosa e il fenomeno del creep. Sono state successivamente eseguite delle prove sperimentali, effettuate presso il Laboratorio Resistenza Materiali e presso il Laboratorio del Dipartimento di Chimica Applicata e Scienza dei Materiali, su dei provini confezionati con otto differenti resine epossidiche. Per valutarne il comportamento alle alte temperature, le indagini sperimentali hanno valutato dapprima le temperature di transizione vetrosa delle resine in questione e, in seguito, le loro caratteristiche meccaniche. Dalla correlazione dei dati rilevati si sono cercati possibili legami tra le caratteristiche meccaniche e le proprietà termiche delle resine. Si sono infine valutati gli aspetti dell’applicazione degli FRP che possano influire sul comportamento del materiale composito soggetto alle alte temperature valutando delle possibili precauzioni che possano essere considerate in fase progettuale.
Resumo:
L’utilizzo di materiali compositi come i calcestruzzi fibrorinforzati sta diventando sempre più frequente e diffuso. Tuttavia la scelta di nuovi materiali richiede una approfondita analisi delle loro caratteristiche e dei loro comportamenti. I vantaggi forniti dall’aggiunta di fibre d’acciaio ad un materiale fragile, quale il calcestruzzo, sono legati al miglioramento della duttilità e all'aumento di assorbimento di energia. L’aggiunta di fibre permette quindi di migliorare il comportamento strutturale del composito, dando vita ad un nuovo materiale capace di lavorare non solo a compressione ma anche in piccola parte a trazione, ma soprattutto caratterizzato da una discreta duttilità ed una buona capacità plastica. Questa tesi ha avuto come fine l’analisi delle caratteristiche di questi compositi cementizi fibrorinforzati. Partendo da prove sperimentali classiche quali prove di trazione e compressione, si è arrivati alla caratterizzazione di questi materiali avvalendosi di una campagna sperimentale basata sull’applicazione della norma UNI 11039/2003. L’obiettivo principale di questo lavoro consiste nell’analizzare e nel confrontare calcestruzzi rinforzati con fibre di due diverse lunghezze e in diversi dosaggi. Studiando questi calcestruzzi si è cercato di comprendere meglio questi materiali e trovare un riscontro pratico ai comportamenti descritti in teorie ormai diffuse e consolidate. La comparazione dei risultati dei test condotti ha permesso di mettere in luce differenze tra i materiali rinforzati con l’aggiunta di fibre corte rispetto a quelli con fibre lunghe, ma ha anche permesso di mostrare e sottolineare le analogie che caratterizzano questi materiali fibrorinforzati. Sono stati affrontati inoltre gli aspetti legati alle fasi della costituzione di questi materiali sia da un punto di vista teorico sia da un punto di vista pratico. Infine è stato sviluppato un modello analitico basato sulla definizione di specifici diagrammi tensione-deformazione; i risultati di questo modello sono quindi stati confrontati con i dati sperimentali ottenuti in laboratorio.
Resumo:
Composite porcelain enamels are inorganic coatings for metallic components based on a special ceramic-vitreous matrix in which specific additives are randomly dispersed. The ceramic-vitreous matrix is made by a mixture of various raw materials and elements and in particular it is based on boron-silicate glass added with metal oxides(1) of titanium, zinc, tin, zirconia, alumina, ecc. These additions are often used to improve and enhance some important performances such as corrosion(2) and wear resistance, mechanical strength, fracture toughness and also aesthetic functions. The coating process, called enamelling, depends on the nature of the surface, but also on the kind of the used porcelain enamel. For metal sheets coatings two industrial processes are actually used: one based on a wet porcelain enamel and another based on a dry-silicone porcelain enamel. During the firing process, that is performed at about 870°C in the case of a steel substrate, the enamel raw material melts and interacts with the metal substrate so enabling the formation of a continuous varying structure. The interface domain between the substrate and the external layer is made of a complex material system where the ceramic vitreous and the metal constituents are mixed. In particular four main regions can be identified, (i) the pure metal region, (ii) the region where the metal constituents are dominant compared with the ceramic vitreous components, (iii) the region where the ceramic vitreous constituents are dominant compared with the metal ones, and the fourth region (iv) composed by the pure ceramic vitreous material. It has also to be noticed the presence of metallic dendrites that hinder the substrate and the external layer passing through the interphase region. Each region of the final composite structure plays a specific role: the metal substrate has mainly the structural function, the interphase region and the embedded dendrites guarantee the adhesion of the external vitreous layer to the substrate and the external vitreous layer is characterized by an high tribological, corrosion and thermal shock resistance. Such material, due to its internal composition, functionalization and architecture can be considered as a functionally graded composite material. The knowledge of the mechanical, tribological and chemical behavior of such composites is not well established and the research is still in progress. In particular the mechanical performances data about the composite coating are not jet established. In the present work the Residual Stresses, the Young modulus and the First Crack Failure of the composite porcelain enamel coating are studied. Due to the differences of the porcelain composite enamel and steel thermal properties the enamelled steel sheets have residual stresses: compressive residual stress acts on the coating and tensile residual stress acts on the steel sheet. The residual stresses estimation has been performed by measuring the curvature of rectangular one-side coated specimens. The Young modulus and the First Crack Failure (FCF) of the coating have been estimated by four point bending tests (3-7) monitored by means of the Acoustic Emission (AE) technique(5,6). In particular the AE information has been used to identify, during the bending tests, the displacement domain over which no coating failure occurs (Free Failure Zone, FFZ). In the FFZ domain, the Young modulus has been estimated according to ASTM D6272-02. The FCF has been calculated as the ratio between the displacement at the first crack of the coating and the coating thickness on the cracked side. The mechanical performances of the tested coated specimens have also been related and discussed to respective microstructure and surface characteristics by double entry charts.
Resumo:
Numerose evidenze dimostrano che le proprietà dei materiali compositi sono strettamente legate ai processi produttivi, alle tipologie di fibra e resina impiegate nel materiale stesso. Proprietà caratterizzate anche dai difetti contenuti nel materiale stesso. Nella tesi si presta particolare attenzione al processo produttivo con prepreg e autoclave trattando anche il tema della stesura di un ply-book. Si valutano in modo teorico e critico alcuni tra i metodi N.D.T. più avanzati tra cui: P.T.(Penetrant Test), Rx(Radiography Test), UT (Ultrasound Test in Phased Array) e IRT (InfraRed Termography - Pulsata). Molteplici sono i componenti testati che variano tra loro per: tipologia di resina e fibra impiegata, processo produttivo e geometria. Tutti questi componenti permettono di capire come i singoli parametri influenzino la visualizzazione e l'applicabilità delle tecniche N.D.T. sopra citate. Su alcuni provini è stata eseguita la prova meccanica Drop Weight Test secondo ASTM D7136 per correlare le aree di delaminazione indotte e la sensibilità di ogni singolo metodo, visualizzando così la criticità indotta dagli urti con bassa energia di impatto (BVID Barely Invisible Impact)di cui i materiali compositi soffrono durante la "service life". A conclusione del lavoro si potrà comprendere come solo l'analisi con più metodi in parallelo permetta di ottenere una adeguata Probability Of Detection.
Resumo:
Studio su giunti incollati attraverso il metodo agli elementi finiti (FEM). E’ stata implementata l’analisi numerica su provini seguendo lo standard della normativa ASTM International relativa a prove sperimentali, per giunzioni di lamine in metallo o in materiale composito. Si è introdotto il materiale composito, cercando di inquadrarne le proprietà, i limiti e i vantaggi rispetto ai materiali tradizionalmente usati, sono stati elencati i difetti che possono nascere e svilupparsi in un composito durante la sua vita operativa, i quali, anche se di piccole dimensioni, a volte possono risultare tanto pericolosi da portare al collasso dell’intera struttura. Nasce, quindi, durante la fase di progettazione la necessità di rilevare, caratterizzare e tenere sotto controllo i danni e considerare i materiali non completamente esenti da difetti. Si è parlato, poi, del processo di riparazione, ove possibile, come alternativa alla sostituzione del componente con un notevole risparmio sui costi di manutenzione. Sono stai presi in esame i vari metodi effettuando un confronto tra essi. Per questo lavoro di tesi, è stato preso in esame l’incollaggio come metodo di fissaggio tra la membrana riparata e la struttura esistente e ne è stata descritta la teoria. Dopo questa panoramica si è passati alla verifica sugli incollaggi attraverso le analisi FEM.