980 resultados para 240401 Optics and Opto-electronic Physics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate complete characterization of a two-qubit entangling process-a linear optics controlled-NOT gate operating with coincident detection-by quantum process tomography. We use a maximum-likelihood estimation to convert the experimental data into a physical process matrix. The process matrix allows an accurate prediction of the operation of the gate for arbitrary input states and a calculation of gate performance measures such as the average gate fidelity, average purity, and entangling capability of our gate, which are 0.90, 0.83, and 0.73, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We generalize a proposal for detecting single-phonon transitions in a single nanoelectromechanical system (NEMS) to include the intrinsic anharmonicity of each mechanical oscillator. In this scheme two NEMS oscillators are coupled via a term quadratic in the amplitude of oscillation for each oscillator. One NEMS oscillator is driven and strongly damped and becomes a transducer for phonon number in the other measured oscillator. We derive the conditions for this measurement scheme to be quantum limited and find a condition on the size of the anharmonicity. We also derive the relation between the phase diffusion back-action noise due to number measurement and the localization time for the measured system to enter a phonon-number eigenstate. We relate both these time scales to the strength of the measured signal, which is an induced current proportional to the position of the read-out oscillator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we describe the process of teleportation between Alice in an inertial frame, and Rob who is in uniform acceleration with respect to Alice. The fidelity of the teleportation is reduced due to Davies-Unruh radiation in Rob's frame. In so far as teleportation is a measure of entanglement, our results suggest that quantum entanglement is degraded in non-inertial frames. We discuss this reduction in fidelity for both bosonic and fermionic resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine whether routine electronic records are an accurate source of population health data in general practice through reviewing cervical smears rates in four South Australian practices. Methods: The cervical screening rate in a purposive sample of four general practices (three rural and one urban) was obtained using an audit of medical records and a telephone follow-up. Results: The cervical screening rate using only immediately available electronic medical records indicated an overall low rate for the participating practices (44.9%). However, telephone follow-up and adjustments to the denominator indicated the real rate to be 85.7%. The offer of appointments during the telephone follow-up further improved this rate for eligible women (93.8%). Conclusions and implications: Electronic medical records may be inadequate in preventive screening in general practice, without ensuring their accuracy. Updating records by telephone or personal follow-up produces a much more accurate denominator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A straightforward method is proposed for computing the magnetic field produced by a circular coil that contains a large number of turns wound onto a solenoid of rectangular cross section. The coil is thus approximated by a circular ring containing a continuous constant current density, which is very close to the real situation when sire of rectangular cross section is used. All that is required is to evaluate two functions, which are defined as integrals of periodic quantities; this is done accurately and efficiently using trapezoidal-rule quadrature. The solution can be obtained so rapidly that this procedure is ideally suited for use in stochastic optimization, An example is given, in which this approach is combined with a simulated annealing routine to optimize shielded profile coils for NMR.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim Stapled haemorrhoidopexy may damage the anorectal musculature and its sensorimotor function. Most studies have not used a barostat for the measurement of compliance. This study aimed to investigate the effect of stapled haemorrhoidopexy on rectal compliance and sensitivity. Method After Ethical Committee approval, we studied 10 male patients (mean age 33.8 years) with third- or fourth-degree haemorrhoids. Rectal compliance and sensitivity were measured with a 600-ml bag and an electronic barostat. Volunteers were submitted to two consecutive rectal distension protocols, including continuous distension at 2, 4 and 6 months after stapled haemorrhoidopexy. Intraluminal volume and pressure were recorded, including the first rectal sensation, desire to defecate and onset of rectal pain. Another group of 10 male control patients (mean age 24.9 years) with pilonidal sinus and no haemorrhoids was also included in the study. Results Two months after stapled haemorrhoidopexy, rectal compliance decreased (7.1 +/- 0.2 vs 5.3 +/- 0.1, 6.4 +/- 0.1 vs 5.1 +/- 0.1 and 5.6 +/- 0.2 vs 4.7 +/- 0.1 ml/mmHg for first rectal sensation, desire to defecate and rectal pain, respectively; P < 0.05). The sensitivity threshold volume did not change for the first sensation but decreased significantly for the desier to defecate and pain (p < 0.05) (116.8 +/- 13.8 vs 148.4 +/- 14.61, 251.1 +/- 8.9 vs 185.8 +/- 8.6 and 293.3 +/- 16.6 vs 221.2 +/- 6.0 ml for first rectal sensation, desire to defecate and rectal pain, respectively). Four and 6 months after surgery, rectal compliance and sensitivity returned to levels similar to those in the basal period. Muscle tissue was found in only three of the 10 resected doughnuts. Controls remained without any change in rectal compliance and sensitivity. Conclusion Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity threshold in young male patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare the productivity of Australian general practice in terms of research publications with the productivity of other medical disciplines. Design: A survey of Australian general practice, medicine, surgery and public health publications carried out by manual searching of specific journals and an electronic search of the US National Library of Medicine's PubMed database. Main outcome measures: The number of original research publications by Australian general practitioners, physicians, surgeons and public health physicians during 1999; the relative publication rate of Australian general practice, medicine, surgery and public health over the period 1990-1999. Results: Of original research articles published in 1999, GPs authored 65% (17/26) in Australian Family Physician and 3% (3/90) in the Medical Journal of Australia; physicians published 4% and 37%, respectively. The electronic search identified 54 research articles relating to Australian general practice published in 1999 in 21 different journals, only two of which were primary care journals. Over the period 1990-1999, there was a publication rate of one general practice [discipline] article per 1000 GPs in practice per year. Corresponding rates for medicine, surgery and public health were 105/1000, 61/1000 and 148/1000, respectively. Conclusions: There is considerable disparity between the level of research output of general practice and that of the disciplines of medicine, surgery and public health. If we are to have effective general practice research, we urgently need to develop research skills, a supportive infrastructure and a culture that nurtures research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently there has been experimental and theoretical interest in cross-dispersion effects in rubidium vapor, which allows one beam of light to be guided by another. We present theoretical results which account for the complications created by the D line hyperfine structure of rubidium as well as the presence of the two major isotopes of rubidium. This allows the complex frequency dependence of the effects observed in our experiments to be understood and lays the foundation for future studies of nonlinear propagation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate that the dynamics of an autonomous chaotic class C laser can be controlled to a periodic state via external modulation of the pump. In the absence of modulation, above the chaos threshold, the laser exhibits Lorenz-like chaotic pulsations. The average amplitude and frequency of these pulsations depend on the pump power. We find that there exist parameter windows where modulation of the pump power extinguishes the chaos in favor of simpler periodic behavior. Moreover we find a number of locking ratios between the pump and laser output follow the Farey sequence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe in detail the theory underpinning the measurement of density matrices of a pair of quantum two-level systems (qubits). Our particular emphasis is on qubits realized by the two polarization degrees of freedom of a pair of entangled photons generated in a down-conversion experiment; however, the discussion applies in general, regardless of the actual physical realization. Two techniques are discussed, namely, a tomographic reconstruction (in which the density matrix is linearly related to a set of measured quantities) and a maximum likelihood technique which requires numerical optimization (but has the advantage of producing density matrices that are always non-negative definite). In addition, a detailed error analysis is presented, allowing errors in quantities derived from the density matrix, such as the entropy or entanglement of formation, to be estimated. Examples based on down-conversion experiments are used to illustrate our results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on a proof of principle demonstration of an optically driven micromachine element. Optical angular momentum is transferred from a circularly polarized laser beam to a birefringent particle confined in an optical tweezers trap. The optical torque causes the particle to spin at up to 350 Hz, and this torque is harnessed to drive an optically trapped microfabricated structure. We describe a photolithographic method for producing the microstructures and show how a light driven motor could be used in a micromachine system. (C) 2001 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method to extract MOSFET's threshold voltage VT by measurement of the gate-to-substrate capacitance C-gb of the transistor is presented. Unlike existing extraction methods based on I-V data, the measurement of C-gb does not require de drain current to now between drain and source thus eliminating the effects of source and drain series resistance R-S/D, and at the same time, retains a symmetrical potential profile across the channel. Experimental and simulation results on devices with different sizes are presented to justify the proposed method.