983 resultados para venous circulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this thesis was to study the removal of gases from paper mill circulation waters experimentally and to provide data for CFD modeling. Flow and bubble size measurements were carried out in a laboratory scale open gas separation channel. Particle Image Velocimetry (PIV) technique was used to measure the gas and liquid flow fields, while bubble size measurements were conducted using digital imaging technique with back light illumination. Samples of paper machine waters as well as a model solution were used for the experiments. The PIV results show that the gas bubbles near the feed position have the tendency to escape from the circulation channel at a faster rate than those bubbles which are further away from the feed position. This was due to an increased rate of bubble coalescence as a result of the relatively larger bubbles near the feed position. Moreover, a close similarity between the measured slip velocities of the paper mill waters and that of literature values was obtained. It was found that due to dilution of paper mill waters, the observed average bubble size was considerably large as compared to the average bubble sizes in real industrial pulp suspension and circulation waters. Among the studied solutions, the model solution has the highest average drag coefficient value due to its relatively high viscosity. The results were compared to a 2D steady sate CFD simulation model. A standard Euler-Euler k-ε turbulence model was used in the simulations. The channel free surface was modeled as a degassing boundary. From the drag models used in the simulations, the Grace drag model gave velocity fields closest to the experimental values. In general, the results obtained from experiments and CFD simulations are in good qualitative agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pacemaker implantation (PMI) may predispose to venous thromboembolism (VTE) and obstruction (VO). This prospective study aimed at quantifying changes in venous calibers, and at determining the incidence of symptomatic and asymptomatic VTE/VO after PMI. Further goals included an assessment of the role of transesophageal echocardiography (TEE) in the diagnosis of lead-related central venous thrombi (CVT), and determination of predictors for VTE/VO. Methods: 150 (mean age 67; 61% male) consecutive patients with first PMI were enrolled and followed for 6 months. Contrast venography was performed at baseline and 6 months after PMI to measure venous diameters, and to detect stenosis, total occlusions and thrombi. TEE was conducted in 66 patients. Based on clinical suspicion, work-up for pulmonary embolism (PE) or acute deep vein thrombosis (DVT) were performed as needed. A total of 50 cases underwent longer-term (mean 2.4 years) follow-up venography. All cases with VTE/VO during the initial 6 months, and their matched controls, were selected for a case-control study focused on possible predictive role of laboratory and patient-related factors for the development of VTE/VO. Results: 10 (7 %) patients were found to have baseline venous abnormalities (e.g. 8 obstructions). Mean venous diameters diminished significantly during the first 6 months, but no further reduction occurred in late follow-up. New VO was discovered in 19 patients (14 %; 14 stenosis, 5 total occlusions; all asymptomatic). Small non-obstructive thrombi were found in 20/140 (14 %) 6-month venograms. TEE at 6 months disclosed CVT in 6 (9 %) patients. One (0.7 %) patient had acute symptomatic upper-extremity DVT, and PE was discovered in 5/150 (3.3 %) patients during the first 6 months with no further cases thereafter. At 6 months, the total number of cases with VTE/VO amounted to 47 (31.3 %). Additionally, the later 2-year venograms (n=50) disclosed 4 (8 %) total occlusions and 1 (2 %) stenosis. In the case-control study, no parameter was predictive of venous end-points as a single variable, but there appeared to be significant clustering of traditional VTE risk-factors among the cases. Laboratory parameters showed a definite acute hypercoagulative state induced by PMI, but its degree did not predict subsequent development of VTE/VO. Conclusions: This study shows that VTE/VO is relatively common after PMI with an overall incidence of at least 30 %. Although the majority of the lesions are asymptomatic and clinically benign, cases of PE were also encountered, and totally occluded veins may hamper future upgrading or replacement of pacing system. Venous complications seem difficult to prognosticate as firm predictors were not identified from a wide range of parameters analyzed in this study, although clustering of classic VTE risk factors may be a predisposing factor. Parameters related to implantation procedure or pacing systems and the severity of implantation-induced trauma did not emerge as predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation: S drive = H steam (ρ down + ρ mix) g where: ρ down - density of water in downcomer tubes; ρ mix - density of water in riser tubes; H steam - height of steam content section; g - acceleration of gravity. In steam boilers with natural circulation the circulation rate is usually between 10 and 30. Thus, consumption of water in the circulation circuit “circulation rate times” more than steam output of the boiler. There are two aspects of the design of natural water circulation loops. One is to ensure a sufficient mass flux of circulating water to avoid burnout of evaporator tubes. The other is to avoid tube wall temperature fluctuation and tube vibration due to oscillation of circulation velocity. The design criteria are therefore reduced, in principle, to those of critical heat flux, critical flow rate for burnout, and flow instability. In practical design, however, the circulation velocity and the void fraction at the evaporator tube outlet are used as the design criteria (Seikan I., et. al., 1999). This study has been made with assumption that the heat flux in the furnace of the boiler even all the time. The target of the study was to define the circulation rate of the boiler, thus average heat flux do not change it. I would like to acknowledge professionals from “Foster Wheeler” company for good and comfortable cooperation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: to determine the incidence of deep vein thrombosis and prophylaxis quality in hospitalized patients undergoing vascular and orthopedic surgical procedures. METHODS: we evaluated 296 patients, whose incidence of deep venous thrombosis was studied by vascular ultrasonography. Risk factors for venous thrombosis were stratified according the Caprini model. To assess the quality of prophylaxis we compared the adopted measures with the prophylaxis guidelines of the American College of Chest Physicians. RESULTS: the overall incidence of deep venous thrombosis was 7.5%. As for the risk groups, 10.8% were considered low risk, 14.9%moderate risk, 24.3% high risk and 50.5% very high risk. Prophylaxis of deep venous thrombosis was correct in 57.7%. In groups of high and very high risk, adequate prophylaxis rates were 72.2% and 71.6%, respectively. Excessive use of chemoprophylaxis was seen in 68.7% and 61.4% in the low and moderate-risk groups, respectively. CONCLUSION: although most patients are deemed to be at high and very high risk for deep vein thrombosis, deficiency in the application of prophylaxis persists in medical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Front of exercise, the organic systems may suffer water-electrolyte and acid-base imbalances, particularly in the case of blood gases, demonstrating variations from different causes, whether respiratory and/or metabolic. Understanding the physiological adaptations to exercise is essential in the search for the optimum performance. In this way, this study measured the venous blood gases (pO2, pCO2), as well as the oxygen saturation (SatO2) in healthy equines, Arabian horses finalists in 90km endurance races. A total of fourteen Arabian horses were evaluated, nine males and five females, between six and 12 years old, finalists in 90km endurance races. There was a significant reduction in pO2, pCO2 and SatO2 after the exercise, however, the values remained within the normality range, and did not change the athletic performance of the animals, indicating a temporary alteration, assuming thus a character of physiological response to the exercise performed. The equines, finalists in 90 Km endurance races, demonstrated efficient ventilatory process, without any alterations in the athletic performance, being adapted to the type of exercise imposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The venom of Lonomia obliqua caterpillar may induce a hemorrhagic syndrome in humans, and blood incoagulability by afibrinogenemia when intravenously injected in laboratory animals. The possible antithrombotic and thrombolytic activities of L. obliqua caterpillar bristle extract (LOCBE) were evaluated in this study. The minimal intravenous dose of the extract necessary to induce afibrinogenemia and anticoagulation was 3.0 and 10.0 µg protein/kg body weight for rabbits and rats, respectively. In rabbits, this dose induced total blood incoagulability for at least 10 h and did not reduce the weight of preformed venous thrombi, in contrast to streptokinase (30,000 IU/kg). In rats, pretreatment with 5.0 and 10.0 µg/kg LOCBE prevented the formation of thrombi induced by venous stasis or by injury to the venous endothelium. The dose of 5.0 µg/kg LOCBE did not modify blood coagulation assay parameters but increased bleeding time and decreased plasma factor XIII concentration. When the extract was administered to rats at the dose of 10.0 µg/kg, the blood was totally incoagulable for 6 h. These data show that LOCBE was effective in preventing experimental venous thrombosis in rats, justifying further studies using purified fractions of the extract to clarify the mechanisms of this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a close association between the location of angiotensin (Ang) receptors and many important brain nuclei involved in the regulation of the cardiovascular system. The present review encompasses the physiological role of Ang II in the brainstem, particularly in relation to its influence on baroreflex control of the heart and kidney. Activation of AT1 receptors in the brainstem by fourth ventricle (4V) administration to conscious rabbits or local administration of Ang II into the rostral ventrolateral medulla (RVLM) of anesthetized rabbits acutely increases renal sympathetic nerve activity (RSNA) and RSNA baroreflex responses. Administration of the Ang antagonist Sarile into the RVLM of anesthetized rabbits blocked the effects of Ang II on the RSNA baroreflex, indicating that the RVLM is the major site of sympathoexcitatory action of Ang II given into the cerebrospinal fluid surrounding the brainstem. However, in conscious animals, blockade of endogenous Ang receptors in the brainstem by the 4V AT1 receptor antagonist losartan resulted in sympathoexcitation, suggesting an overall greater activity of endogenous Ang II within the sympathoinhibitory pathways. However, the RSNA response to airjet stress in conscious rabbits was markedly attenuated. While we found no effect of acute central Ang on heart rate baroreflexes, chronic 4V infusion inhibited the baroreflex and chronic losartan increased baroreflex gain. Thus, brainstem Ang II acutely alters sympathetic responses to specific afferent inputs thus forming part of a potentially important mechanism for the integration of autonomic response patterns. The sympathoexcitatory AT1 receptors appear to be activated during stress, surgery and anesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study we standardized an experimental model of parabiotic circulation of isolated pig heart. The isolated heart was perfused with arterial blood from a second animal as support and submitted to regional ischemia for 30 min, followed by total ischemia for 90 min and reperfusion for 90 min. Parameters for measurement of ventricular performance using different indices measured directly or indirectly from intraventricular pressure were defined as: maximum peak pressure, final diastolic pressure, pressure developed, first derivative of maximum pressure (dP/dt max), first derivative of minimum pressure (dP/dt min), systolic stress of the left ventricle (sigmas), and maximum elastance of the left ventricle. Isolated hearts subjected to regional and global ischemia presented significant worsening of all measured parameters. Less discriminative parameters were dP/dt max and dP/dt min. Elastance was the most sensitive parameter during the reperfusion period, demonstrating an early loss of ventricular function during reperfusion. The model proved to be stable and reproducible and permitted the study of several variables in the isolated heart, such as ischemia and reperfusion phenomena, the effects of different drugs, surgical interventions, etc. The model introduces an advantage over the classical models which use crystalloid solutions as perfusate, because parabiotic circulation mimics heart surgery with extracorporeal circulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated vascular reactivity after a maximal exercise test in order to determine whether the effect of exercise on the circulation persists even after interruption of the exercise. Eleven healthy sedentary volunteers (six women, age 28 ± 5 years) were evaluated before and after (10, 60, and 120 min) a maximal exercise test on a treadmill. Forearm blood flow (FBF) was measured by venous occlusion plethysmography before and during reactive hyperemia (RH). Baseline FBF, analyzed by the area under the curve, increased only at 10 min after exercise (P = 0.01). FBF in response to RH increased both at 10 and 60 min vs baseline (P = 0.004). Total excess flow for RH above baseline showed that vascular reactivity was increased up to 60 min after exercise (mean ± SEM, before: 526.4 ± 48.8; 10 min: 1053.0 ± 168.2; 60 min: 659.4 ± 44.1 ml 100 ml-1 min-1 . s; P = 0.01 and 0.02, respectively, vs before exercise). The changes in FBF were due to increased vascular conductance since mean arterial blood pressure did not change. In a time control group (N = 5, 34 ± 3 years, three women) that did not exercise, FBF and RH did not change significantly (P = 0.07 and 0.7, respectively). These results suggest that the increased vascular reactivity caused by chronic exercise may result, at least in part, from a summation of the subacute effects of successive exercise bouts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Northeast region is the location of most cases of acute hepatitis A virus (HAV) in Brazil. In the present study, the genotypes of HAV strains from Pernambuco State, one of most populous states in the Northeast region, were characterized. Blood samples positive for anti-HAV IgM from 145 individuals (mean age = 29.1 years), collected during 2002 and 2003, were submitted to nested RT-PCR for amplification of the 5'non-translated region (5'NTR) and VP1/2A regions of the HAV genome. The VP1/2A and 5'NTR regions were amplified in 39 and 21% of the samples, respectively. Nucleotide sequencing was carried out in 46% of VP1/2A and in 53% of 5'NTR isolates. The identity in nucleotide sequence of the VP1/2A region ranged from 93.6 to 100.0%. Phylogenetic analysis of the VP1/2A sequences showed that 65% belong to sub-genotype IA and 35% to sub-genotype IB. Co-circulation of both sub-genotypes was observed in the two years studied. Distinct clusters of highly related sequences were observed in both sub-genotypes, suggesting endemic circulation of HAV strains in this area. In the 5'NTR isolates, 92.7-99.2% identity was observed and two isolates presented one deletion at position 413. Phylogenetic analysis showed that genotype IA strains cluster in the tree in the same way as genotype IB strains, but one IIIA isolate from Spain clusters with genotype IB strains. These results do not allow us to state that 5'NTR could be used to genotype HAV sequences. This is the first report of co-circulation of sub-genotypes IA and IB in this region, providing additional information about the molecular epidemiology of HAV strains in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of routine vaccination against tetanus and diphtheria in Brazil has decreased the incidence and changed the epidemiology of both diseases. We then investigated the prevalence of Corynebacterium diphtheriae carrier status and diphtheria and tetanus immunity in São Paulo, Brazil. From November 2001 to March 2003, 374 individuals were tested for the presence of C. diphtheriae in the naso-oropharynx and of serum diphtheria and tetanus antibodies. Participants were all healthy individuals without acute or chronic pathologies and they were stratified by age as follows: 0-12 months and 1-4, 5-9, 10-14, 15-24, 25-39, 40-59, and ³60 years. Antibodies were assessed using a double-antigen ELISA. C. diphtheriae species were identified by biochemical analysis and toxigenicity was assessed by the Elek test. For diphtheria, full protection (antibodies ³0.1 IU/mL) was present in 84% of the individuals, 15% had basic protection (antibodies ³0.01 and <0.1 IU/mL) and 1% were susceptible (antibodies <0.01 IU/mL). Full tetanus protection (antibodies ³0.1 IU/mL) was present in 79% of the participants, 18% had basic protection (antibodies ³0.01 and <0.1 IU/mL) and 3% were susceptible (antibodies <0.01 IU/mL). The geometric mean of diphtheria and tetanus antibodies reached the highest values at 5-9 years and decreased until the 40-59-year age range, increasing again in individuals over 60 years. Three participants (0.8%) were carriers of C. diphtheriae, all non-toxigenic strains. The present results demonstrate the clear need of periodic booster for tetanus and diphtheria vaccine in adolescents and adults after primary immunization in childhood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to determine the acute effect of hemodialysis on endothelial venous function and oxidative stress. We studied 9 patients with end-stage renal disease (ESRD), 36.8 ± 3.0 years old, arterial pressure 133.8 ± 6.8/80.0 ± 5.0 mmHg, time on dialysis 55.0 ± 16.6 months, immediately before and after a hemodialysis session, and 10 healthy controls matched for age and gender. Endothelial function was assessed by the dorsal hand vein technique using graded local infusion of acetylcholine (endothelium-dependent venodilation, EDV) and sodium nitroprusside (endothelium-independent venodilation). Oxidative stress was evaluated by measuring protein oxidative damage (carbonyls) and antioxidant defense (total radical trapping antioxidant potential - TRAP) in blood samples. All patients were receiving recombinant human erythropoietin for at least 3 months and were not taking nitrates or a-receptor antagonists. EDV was significantly lower in ESRD patients before hemodialysis (65.6 ± 10.5) vs controls (109.6 ± 10.8; P = 0.010) and after hemodialysis (106.6 ± 15.7; P = 0.045). Endothelium-independent venodilation was similar in all comparisons performed. The hemodialysis session significantly decreased TRAP (402.0 ± 53.5 vs 157.1 ± 28.3 U Trolox/µL plasma; P = 0.001). There was no difference in protein damage comparing ESRD patients before and after hemodialysis. The magnitude of change in the EDV was correlated negatively with the magnitude of change in TRAP (r = -0.70; P = 0.037). These results suggest that a hemodialysis session improves endothelial venous function, in association with an antioxidant effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous thrombosis, including deep vein thrombosis and pulmonary embolism, is a common disease that frequently recurs. Recurrence can be prevented by anticoagulants, but this comes at the risk of bleeding. Therefore, assessment of the risk of recurrence is important to balance the risks and benefits of anticoagulant treatment. This review briefly outlines what is currently known about the epidemiology of recurrent venous thrombosis, and focuses in more detail on potential new risk factors for venous recurrence. The general implications of these findings in patient management are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcutaneous electrical nerve stimulation (TENS) is a type of therapy used primarily for analgesia, but also presents changes in the cardiovascular system responses; its effects are dependent upon application parameters. Alterations to the cardiovascular system suggest that TENS may modify venous vascular response. The objective of this study was to evaluate the effects of TENS at different frequencies (10 and 100 Hz) on venous vascular reactivity in healthy subjects. Twenty-nine healthy male volunteers were randomized into three groups: placebo (n=10), low-frequency TENS (10 Hz, n=9) and high-frequency TENS (100 Hz, n=10). TENS was applied for 30 min in the nervous plexus trajectory from the superior member (from cervical to dorsal region of the fist) at low (10 Hz/200 μs) and high frequency (100 Hz/200 μs) with its intensity adjusted below the motor threshold and intensified every 5 min, intending to avoid accommodation. Venous vascular reactivity in response to phenylephrine, acetylcholine (endothelium-dependent) and sodium nitroprusside (endothelium-independent) was assessed by the dorsal hand vein technique. The phenylephrine effective dose to achieve 70% vasoconstriction was reduced 53% (P<0.01) using low-frequency TENS (10 Hz), while in high-frequency stimulation (100 Hz), a 47% increased dose was needed (P<0.01). The endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) responses were not modified by TENS, which modifies venous responsiveness, and increases the low-frequency sensitivity of α1-adrenergic receptors and shows high-frequency opposite effects. These changes represent an important vascular effect caused by TENS with implications for hemodynamics, inflammation and analgesia.