947 resultados para quantization artifacts
Resumo:
A very accurate archaeological dating of a Roman site in NE Spain (El Vila-sec) was made based on the typology of pottery artifacts. Three different phases were identifi ed with activity ranging from the mid- 1st century BC to the early-3rd century AD. Analyses of bricks from kilns at El Vila-sec produced data on their stored archaeomagnetic vector. These data were compared with the secular variation curve for the Iberian Peninsula and the SCHA.DIF.3K regional archaeomagnetic model. Both, the reference curve and the model, produced probability distributions for the final period of use for two kilns from the second archaeological phase that were not used during the third phase. At a 95% con fidence level, both time distributions cover a wide chronological range including the presumed archaeological age. Both the Iberian secular variation curve and the SCHA.DIF.3K regional model proved to be suitable models for dating the site, although on their own they do not produce a single unambiguous solution. This archaeomagnetic approach could also be applied to neighbouring archaeological sites that have an imprecise archaeological age.
Resumo:
OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.
3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.
Resumo:
Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.
Resumo:
Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectroscopic editing scheme, dubbed "selective Resonance suppression by Adiabatic Carbon Editing and Decoupling single-voxel STimulated Echo Acquisition Mode" (RACED-STEAM). The sequence is based on the application of two asymmetric narrow-transition-band adiabatic RF inversion pulses at the resonance frequency of the 13C coupled to the protons that need to be suppressed during the mixing time (TM) period, alternating the inversion band downfield and upfield from the 13C resonance on odd and even scans, respectively, thus suppressing the detection of 1H resonances bound to 13C within the transition band of the inversion pulse. The results demonstrate the efficient suppression of 1H resonances bound to C3 of Glu and Gln, and C4 of Glu, which allows the 1H resonances bound to C6 of NAA and C4 of Gln to be revealed. The measured time course of the resolved labeling into NAA C6 with the new scheme was consistent with the slow turnover of NAA.
Resumo:
Intraoperative ultrasound (IOUS) has been described to be useful during central corpectomy for compressive cervical myelopathy. This study aimed at documenting the utility of IOUS in oblique cervical corpectomy (OCC). Prospective data from 24 patients undergoing OCC for cervical spondylotic myelopathy and ossified posterior longitudinal ligament (OPLL) were collected. Patients had a preoperative cervical spine magnetic resonance (MR) image, IOUS and a postoperative cervical CT scan. Retrospective data from 16 historical controls that underwent OCC without IOUS were analysed to compare the incidence of residual compression between the two groups. IOUS identified the vertebral artery in all cases, detected residual cord compression in six (27%) and missed compression in two cases (9%). In another two cases with OPLL, IOUS was sub-optimal due to shadowing. IOUS measurement of the corpectomy width correlated well with these measurements on the postoperative CT. The extent of cord expansion noted on IOUS after decompression showed no correlation with immediate or 6-month postoperative neurological recovery. No significant difference in residual compression was noted in the retrospective and prospective groups of the study. Craniocaudal spinal cord motion was noted after the completion of the corpectomy. IOUS is an inexpensive and simple real-time imaging modality that may be used during OCC for cervical spondylotic myelopathy. It is helpful in identifying the vertebral artery and determining the trajectory of approach, however, it has limited utility in patients with OPLL due to artifacts from residual ossification.
Resumo:
Artifacts are present in most of the electroencephalography (EEG) recordings, making it difficult to interpret or analyze the data. In this paper a cleaning procedure based on a multivariate extension of empirical mode decomposition is used to improve the quality of the data. This is achieved by applying the cleaning method to raw EEG data. Then, a synchrony measure is applied on the raw and the clean data in order to compare the improvement of the classification rate. Two classifiers are used, linear discriminant analysis and neural networks. For both cases, the classification rate is improved about 20%.
Resumo:
Intracellular mature vaccinia virus, also called intracellular naked virus, and its core envelope have been observed in their native, unfixed, unstained, hydrated states by cryoelectron microscopy of vitrified samples. The virion appears as a smooth rounded rectangle of ca. 350 by 270 nm. The core seems homogeneous and is surrounded by a 30-nm-thick surface domain delimited by membranes. We show that surface tubules and most likely also the characteristic dumbbell-shaped core with the lateral bodies which are generally observed in negatively stained or conventionally embedded samples are preparation artifacts.
Resumo:
When individuals learn by trial-and-error, they perform randomly chosen actions and then reinforce those actions that led to a high payoff. However, individuals do not always have to physically perform an action in order to evaluate its consequences. Rather, they may be able to mentally simulate actions and their consequences without actually performing them. Such fictitious learners can select actions with high payoffs without making long chains of trial-and-error learning. Here, we analyze the evolution of an n-dimensional cultural trait (or artifact) by learning, in a payoff landscape with a single optimum. We derive the stochastic learning dynamics of the distance to the optimum in trait space when choice between alternative artifacts follows the standard logit choice rule. We show that for both trial-and-error and fictitious learners, the learning dynamics stabilize at an approximate distance of root n/(2 lambda(e)) away from the optimum, where lambda(e) is an effective learning performance parameter depending on the learning rule under scrutiny. Individual learners are thus unlikely to reach the optimum when traits are complex (n large), and so face a barrier to further improvement of the artifact. We show, however, that this barrier can be significantly reduced in a large population of learners performing payoff-biased social learning, in which case lambda(e) becomes proportional to population size. Overall, our results illustrate the effects of errors in learning, levels of cognition, and population size for the evolution of complex cultural traits. (C) 2013 Elsevier Inc. All rights reserved.
Resumo:
El objetivo del artículo es presentar las bases teóricas y conceptuales de una disciplina a medio camino entre la psicología, la geografía y la antropología: la “psicogeografía cultural del desarrollo humano” (PCDH). Entendiendo por PCDH el estudio del desarrollo psicológico humano dentro de ciertas “geografías vitales y psicológicas” como un río, montaña o valle; una institución social como la escuela o la familia; ciertos artefactos como una bandera, un libro o un mapa; ideologías como el nacionalismo o liberalismo; relaciones sociales entre, por ejemplo, padre e hijo y ciertas actividades realizadas
Resumo:
MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.
Resumo:
PURPOSE: A new magnetic resonance imaging approach for detection of myocardial late enhancement during free-breathing was developed. METHODS AND RESULTS: For suppression of respiratory motion artifacts, a prospective navigator technology including real-time motion correction and a local navigator restore was implemented. Subject specific inversion times were defined from images with incrementally increased inversion times acquired during a single dynamic scout navigator-gated and real-time motion corrected free-breathing scan. Subsequently, MR-imaging of myocardial late enhancement was performed with navigator-gated and real-time motion corrected adjacent short axis and long axis (two, three and four chamber) views. This alternative approach was investigated in 7 patients with history of myocardial infarction 12 min after i. v. administration of 0.2 mmol/kg body weight gadolinium-DTPA. CONCLUSION: With the presented navigator-gated and real-time motion corrected sequence for MR-imaging of myocardial late enhancement data can be completely acquired during free-breathing. Time constraints of a breath-hold technique are abolished and optimized patient specific inversion time is ensured.
Resumo:
PURPOSE: At high magnetic field strengths (B0 ≥ 3 T), the shorter radiofrequency wavelength produces an inhomogeneous distribution of the transmit magnetic field. This can lead to variable contrast across the brain which is particularly pronounced in T2 -weighted imaging that requires multiple radiofrequency pulses. To obtain T2 -weighted images with uniform contrast throughout the whole brain at 7 T, short (2-3 ms) 3D tailored radiofrequency pulses (kT -points) were integrated into a 3D variable flip angle turbo spin echo sequence. METHODS: The excitation and refocusing "hard" pulses of a variable flip angle turbo spin echo sequence were replaced with kT -point pulses. Spatially resolved extended phase graph simulations and in vivo acquisitions at 7 T, utilizing both single channel and parallel-transmit systems, were used to test different kT -point configurations. RESULTS: Simulations indicated that an extended optimized k-space trajectory ensured a more homogeneous signal throughout images. In vivo experiments showed that high quality T2 -weighted brain images with uniform signal and contrast were obtained at 7 T by using the proposed methodology. CONCLUSION: This work demonstrates that T2 -weighted images devoid of artifacts resulting from B1 (+) inhomogeneity can be obtained at high field through the optimization of extended kT -point pulses. Magn Reson Med 71:1478-1488, 2014. © 2013 Wiley Periodicals, Inc.
Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction.
Resumo:
Respiratory motion is a major source of artifacts in cardiac magnetic resonance imaging (MRI). Free-breathing techniques with pencil-beam navigators efficiently suppress respiratory motion and minimize the need for patient cooperation. However, the correlation between the measured navigator position and the actual position of the heart may be adversely affected by hysteretic effects, navigator position, and temporal delays between the navigators and the image acquisition. In addition, irregular breathing patterns during navigator-gated scanning may result in low scan efficiency and prolonged scan time. The purpose of this study was to develop and implement a self-navigated, free-breathing, whole-heart 3D coronary MRI technique that would overcome these shortcomings and improve the ease-of-use of coronary MRI. A signal synchronous with respiration was extracted directly from the echoes acquired for imaging, and the motion information was used for retrospective, rigid-body, through-plane motion correction. The images obtained from the self-navigated reconstruction were compared with the results from conventional, prospective, pencil-beam navigator tracking. Image quality was improved in phantom studies using self-navigation, while equivalent results were obtained with both techniques in preliminary in vivo studies.
Resumo:
The "one-gene, one-protein" rule, coined by Beadle and Tatum, has been fundamental to molecular biology. The rule implies that the genetic complexity of an organism depends essentially on its gene number. The discovery, however, that alternative gene splicing and transcription are widespread phenomena dramatically altered our understanding of the genetic complexity of higher eukaryotic organisms; in these, a limited number of genes may potentially encode a much larger number of proteins. Here we investigate yet another phenomenon that may contribute to generate additional protein diversity. Indeed, by relying on both computational and experimental analysis, we estimate that at least 4%-5% of the tandem gene pairs in the human genome can be eventually transcribed into a single RNA sequence encoding a putative chimeric protein. While the functional significance of most of these chimeric transcripts remains to be determined, we provide strong evidence that this phenomenon does not correspond to mere technical artifacts and that it is a common mechanism with the potential of generating hundreds of additional proteins in the human genome.
Resumo:
Résumé -Caractéristiques architecturales des génomes bactériens et leurs applications Les bactéries possèdent généralement un seul chromosome circulaire. A chaque génération, ce chromosome est répliqué bidirectionnellement, par deux complexes enzymatiques de réplication se déplaçant en sens opposé depuis l'origine de réplication jusqu'au terminus, situé à l'opposé. Ce mode de réplication régit l'architecture du chromosome -l'orientation des gènes par rapport à la réplication, notamment - et est en grande partie à l'origine des pressions qui provoquent la variation de la composition en nucléotides du génome, hors des contraintes liées à la structure et à la fonction des protéines codées sur le chromosome. Le but de cette thèse est de contribuer à quantifier les effets de la réplication sur l'architecture chromosomique, en s'intéressant notamment aux gènes des ARN ribosomiques, cruciaux pour la bactérie. D'un autre côté, cette architecture est spécifique à l'espèce et donne ainsi une «identité génomique » aux gènes. Il est démontré ici qu'il est possible d'utiliser des marqueurs «naïfs » de cette identité pour détecter, notamment dans le génome du staphylocoque doré, des îlots de pathogénicité, qui concentrent un grand nombre de facteurs de virulence de la bactérie. Ces îlots de pathogénicité sont mobiles, et peuvent passer d'une bactérie à une autre, mais conservent durant un certain temps l'identité génomique de leur hôte précédent, ce qui permet de les reconnaître dans leur nouvel hôte. Ces méthodes simples, rapides et fiables seront de la plus haute importance lorsque le séquençage des génomes entiers sera rapide et disponible à très faible coût. Il sera alors possible d'analyser instantanément les déterminants pathogéniques et de résistance aux antibiotiques des agents pathogènes. Summary The bacterial genome is a highly organized structure, which may be referred to as the genome architecture, and is mainly directed by DNA replication. This thesis provides significant insights in the comprehension of the forces that shape bacterial chromosomes, different in each genome and contributing to confer them an identity. First, it shows the importance of the replication in directing the orientation of prokaryotic ribosomal RNAs, and how it shapes their nucleotide composition in a tax on-specific manner. Second, it highlights the pressure acting on the orientation of the genes in general, a majority of which are transcribed in the same direction as replication. Consequently, apparent infra-arm genome rearrangements, involving an exchange of the leading/lagging strands and shown to reduce growth rate, are very likely artifacts due to an incorrect contig assembly. Third, it shows that this genomic identity can be used to detect foreign parts in genomes, by establishing this identity for a given host and identifying the regions that deviate from it. This property is notably illustrated with Staphylococcus aureus: known pathogenicity islands and phages, and putative ancient pathogenicity islands concentrating many known pathogenicity-related genes are highlighted; the analysis also detects, incidentally, proteins responsible for the adhesion of S. aureus to the hosts' cells. In conclusion, the study of nucleotide composition of bacterial genomes provides the opportunity to better understand the genome-level pressures that shape DNA sequences, and to identify genes and regions potentially related to pathogenicity with fast, simple and reliable methods. This will be of crucial importance when whole-genome sequencing will be a rapid, inexpensive and routine tool.