976 resultados para orbital perturbations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: DON, a serious complication of GO, is frequently difficult to diagnose clinically in its early stages because of confounding signs and symptoms of congestive orbitopathy. We evaluated the ability of square area measurements of orbital apex crowding, calculated with MDCT, to detect DON. MATERIALS AND METHODS: Fifty-six patients with GO were studied prospectively with complete neuro-ophthalmologic examination and MDCT scanning. Square measurements were taken from coronal sections 12 mm, 18 mm, and 24 mm from the interzygomatic line. The ratio between the extraocular muscle area and the orbital bone area was used as a Cl. Intracranial fat prolapse through the superior orbital fissure was recorded as present or absent. Severity of optic nerve crowding was also subjectively graded on corona! images. Orbits were divided into 2 groups (with or without clinical evidence of DON) and compared. RESULTS: Ninety-five orbits (36 with and 59 without DON) were studied. The CIs at all 3 levels and the subjective crowding score were significantly greater in orbits with DON (P<.001). No significant difference was observed regarding intracranial fat prolapse (P=.105). The area under the ROC curves was 0.91, 0.93, and 0.87 for CIs at 12, 18, and 24 mm, respectively. The best performance was at 18 mm, where a cutoff value of 57.5% corresponded to 91.7% sensitivity, 89.8% specificity, and an odds ratio of 97.2 for detecting DON. A significant correlation (P<.001) between the CIs and VF defects was observed. CONCLUSIONS: Orbital Cls based on area measurements were found to predict DON more reliably than subjective grading of orbital crowding or intracranial fat prolapse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantify the risk of new diplopia in inferomedial orbital decompression performed for cosmetic reasons. Methods: Retrospective analysis of 114 patients with Graves orbitopathy who underwent an inferomedial orbital decompression. No patient had diplopia in any of the gaze positions or optic neuropathy. A single coronal slice 9 mm posterior to the lateral orbital rim was employed to quantify the muscular index of the extraocular recti and of the superior complex. A control group of 56 patients imaged for other reasons were also measured. After surgery the oculomotor status of all patients who complained of diplopia and of 51 patients free of diplopia was measured with the prism and cover test in the primary and secondary gaze positions. Results: The rate of new-onset diplopia was 14.0% (16 patients). Eye deviations were confirmed in 14 patients. Of these, 10 had significant strabismus that warranted surgical or prism treatment. Most patients had esotropia associated with small vertical deviations. The size of the medial and inferior recti was significantly associated with the development of diplopia. The estimated odds for the appearance of diplopia in patients with muscle enlargement was 12.76 (medial rectus) and 5.21 (inferior rectus). Small-angle deviations were also detected in 27.4% of patients who did not experience diplopia. Conclusions: Medial and inferior recti enlargement is a strong predictor of new-onset diplopia. A large number of patients who do not report diplopia also present with small-angle deviations. (Ophthal Plast Reconstr Surg 2012;28:204-207)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 12-year-old girl had a 6-year history of a large soft-tissue mass in her left orbit. The tumor biopsy was previously performed elsewhere when she was 7 years old, but no treatment was offered at that time. Later, the tumor was completely excised, and histologic examination revealed a mesenchymal neoplasia with typical hemangiopericytoma features. At 9 months of follow up, no evidence of local recurrence or metastasis was seen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven sides of cadaver heads were used to compare the surgical exposures provided by the mini-modified orbitozygomatic (MOz) and supra-orbital (SO) approaches. The Optotrak 3020 computerized tracking system (Northern Digital, Waterloo, ON, Canada) was utilized to evaluate the area of anatomical exposure defined by six points: (1) ipsilateral sphenoid ridge; (2) most distal point of the ipsilateral middle cerebral artery (MCA); (3) most distal point of the ipsilateral posterior cerebral artery (PCA); (4) most distal point of the contralateral PCA; (5) most distal point of the contralateral MCA; and (6) contralateral sphenoid ridge. Additionally, angles of approach for the ipsilateral MCA bifurcation, ipsilateral ICA bifurcation, basilar artery tip, contralateral MCA and ICA bifurcation and anterior communicating artery (AcomA) were evaluated, first for SO and then for MOz. An image guidance system was used to evaluate the limits of surgical exposure. No differences in the area of surgical exposure were noted (p > 0.05). Vertical angles were significantly wider for the ipsilateral and contralateral ICA bifurcation, AcomA, contralateral MCA and basilar tip (p < 0.05) for MOz. No differences in horizontal angles were observed between the approaches for the six targets (p > 0.05). There were no differences in the limits of exposure. MOz affords no additional surgical working space. However, our results demonstrate systematically that vertical exposure is improved. The MOz should be performed while planning an approach to these regions and a wider exposure in the vertical axis is needed. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this communication we report results from the application to the study of the rotation of the Moon of the creeping tide theory just proposed (Ferraz-Mello, Cel. Mech. Dyn. Astron., submitted. ArXiv astro-ph 1204.3957). The choice of the Moon for the first application of this new theory is motivated by the fact that the Moon is one of the best observed celestial bodies and the comparison of the theoretical predictions of the theory with observations i may validate the theory or point out the need of further improvements. Particularly, the tidal perturbations of the rotation of the Moon - the physical libration of the Moon - have been detected in the Lunar Laser Ranging measurements (Williams et al. JGR 106, 27933, 2001). The major difficulty in this application comes from the fact that tidal torques in a planet-satellite system are very sensitive to the distance between the two-bodies, which is strongly affected by Solar perturbations. In the case of the Moon, the main solar perturbations - the Evection and the Variation - are more important than most of the Keplerian oscillations, being smaller only than the first Keplerian harmonic (equation of the centre). Besides, two of the three components of the Moon's libration in longitude whose tidal contributions were determined by LLR are related to these perturbations. The results may allow us to determine the main parameter of a possible Moon's creeping tide. The preliminary results point to a relaxation factor (gamma) 2 to 4 times smaller than the one predicted from the often cited values of thr Moon's quality factor Q (between 30 and 40), and points to larger Q values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the orbital evolution of a two co-orbital planet system which undergo tidal interactions with the central star. Our main goal is to investigate the final outcome of a system originally evolving in a 1:1 resonant configuration when the tidal effect acts to change the orbital elements. Preliminary results of the numerical simulations of the exact equations of motions indicate that, at least for equal mass planets, the combined effect of resonant motion and tidal interaction leads the system to orbital instability, including collisions between the planets. We discuss the cases of two hot super-Earths and two hot-Saturn planets, comparing with the results of dynamical maps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first part of the thesis concerns the study of inflation in the context of a theory of gravity called "Induced Gravity" in which the gravitational coupling varies in time according to the dynamics of the very same scalar field (the "inflaton") driving inflation, while taking on the value measured today since the end of inflation. Through the analytical and numerical analysis of scalar and tensor cosmological perturbations we show that the model leads to consistent predictions for a broad variety of symmetry-breaking inflaton's potentials, once that a dimensionless parameter entering into the action is properly constrained. We also discuss the average expansion of the Universe after inflation (when the inflaton undergoes coherent oscillations about the minimum of its potential) and determine the effective equation of state. Finally, we analyze the resonant and perturbative decay of the inflaton during (p)reheating. The second part is devoted to the study of a proposal for a quantum theory of gravity dubbed "Horava-Lifshitz (HL) Gravity" which relies on power-counting renormalizability while explicitly breaking Lorentz invariance. We test a pair of variants of the theory ("projectable" and "non-projectable") on a cosmological background and with the inclusion of scalar field matter. By inspecting the quadratic action for the linear scalar cosmological perturbations we determine the actual number of propagating degrees of freedom and realize that the theory, being endowed with less symmetries than General Relativity, does admit an extra gravitational degree of freedom which is potentially unstable. More specifically, we conclude that in the case of projectable HL Gravity the extra mode is either a ghost or a tachyon, whereas in the case of non-projectable HL Gravity the extra mode can be made well-behaved for suitable choices of a pair of free dimensionless parameters and, moreover, turns out to decouple from the low-energy Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die vorliegende Dissertation beschaftigt sich mit der Steuerung der Absorption und Orbitalenergien von Perylenmonoimiden und Perylendiimiden fur die Anwendung in organischer Photovoltaik (OPV). Eine breite Absorption spielt hier eine wichtige Rolle, um moglichst viel Licht zu ernten, das dann in elektrische Energie umgewandelt wird. Um sicher zu stellen, dass die Zelle ezient arbeiten kann, ist die Abstimmung von Orbitalenergien eine zweite wichtige Voraussetzung. Es werden drei neue Design-Konzepte fur Perylenmonoimid-Sensibilatoren fur Festk orper-Farbstosolarzellen (solid-state dye-sensitised solar cells - sDSSCs) untersucht. Die Synthese, die optischen und elektronischen Eigenschaften der neuen Sensibilisator- Verbindungen sowie ihre Leistungsdaten in sDSSCs werden beschrieben und diskutiert. Die in dieser Arbeit vorgestellten Konzepte reichen von der Einfuhrung von - Abstandhaltern uber neue Funktionalisierungen bis hin zur Erweiterung der Perylenmonimid Grundkorper. Der Push-Pull-Charakter der Systeme variiert von starker Kopplung bis zu kompletter Entkopplung des Donors vom Akzeptor. Dies hat einen starken Ein uss sowohl auf die Absorptionseigenschaften, als auch auf die HOMO/LUMO Energie-Niveaus der Verbindungen. Einige der Konzepte konnen auf Perylendiimide ubertragen werden. Ein Beispiel von Perylendiimid (PDI)-Farbsteuerung wird an einer Reihe von drei Terthiophen-PDIs gezeigt

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to share our clinical experience in the use and accuracy of a newly designed, low-profile titanium mesh (Modus OPS 1.5; Medartis, Basel, Switzerland) for primary internal orbital reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of an accidental death or potential suicide by revolver with subsequent injury of another person. A 44-year-old man shot himself in the head while manipulating his.38 caliber special revolver in the kitchen in the presence of his wife, standing approximately 1.5 m next to him. After passing through the husband's head, the lead round-nose bullet entered the region underneath his wife's left eye. When the bullet left the man's head, it retained the energy to penetrate the soft tissue at this distance, including the skin and thin bone plates like the orbital wall. Owing to the low energy of the projectile, the entry wound was of atypical in shape and without loss of tissue. Only a small line-resembling a cut-was externally visible. The man died in the hospital from his injuries; his wife suffered visual loss of her left eye.