914 resultados para glassy carbon electrode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study we describe the electrochemical behavior of 5,10,15,20-tetrakis(2'-aminophenylporphyrin)manganese(III) chloride supported on a glassy carbon electrode, as well as the electrochemical preparation and characterization of thin films based on pyrrole-3-carboxylic acid. The electrocatalytic action of the electrode modified with the Mn(III) porphyrin toward an azo dye was tested, and the characteristic strong interaction between the incorporated metalloporphyrin and RR120 dye was verified. Copyright (c) 2006 Society of Porphyrins & Phthalocyanines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Indanthrene Olive Green B (C.I. Vat Green 3; C.I. 69500), VG3 dye, a vat dye bearing an anthraquinonoid group and a ketonic group, can be detected by differential pulse voltammetry in alkaline solution using glassy carbon electrode. on the adsorbed form the dyes are reduced into three cathodic steps at -0.54 V, -0.65 V and -0.93 V vs Ag/AgCl. The leuco form generated after previous electrolysis at controlled potential of -1 V can be detected by voltammetry due to its reoxidation peak at -0.08 V. An analytical method is proposed for determining the vat dye using modified glassy carbon electrode by electrochemical activation in alkaline medium. Linear relationship was observed between l(Pu) vs concentration from I X 10(-5) mol L-1 to 6.0 X 10(-4) mol L-1. The detection limit was calculated to be 9.3 X 10(-6) mol L-1. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oxidation of a reactive dye, Reactive Blue 4, RB4, (C.I. 61205), widely used in the textile industries to color natural fibers, was studied by electrochemical techniques. The oxidation on glassy carbon electrode and reticulated vitreous carbon electrode occurs in only one step at 2.0 < PH < 12 involving a two-electron transfer to the amine group leading to the imide derivative. Dye solution was not decolorized effectively in this electrolysis process. Nevertheless, the oxidation of this dye on Ti/SnO2/SbOx (3% mol)/RuO2 (1% mol) electrode showed 100% of decolorization and 60% of total organic carbon removal in Na2SO4 0.2 M at PH 2.2 and potential of +2.4 V. Experiments on degradation photoelectrocatalytic were also carried out for RB4 degradation in Na2SO4 0.1 K PH 12, using a Ti/TiO2 photoanode biased at +1.0 V and UV light. After 1 h of electrolysis the results indicated total color removal and 37% of mineralization. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A versatile voltammetric method for quantitative determination of fenbendazole (FBZ) in commercial tablets has been proposed, where direct dissolution of tablets is carried out in 0.1 mol l(-1) tetrabutylamoniun tetrafluorborate containing dimethylformamide solutions. Linear sweep (LSV), square wave (SWV) and differential pulse (DPV) voltammetry techniques were applied to study FBZ at a glassy carbon electrode, exhibiting a well defined irreversible oxidation peak at 1.15 V vs. SCE. This methodology allows a precise quantitative determination of FBZ presenting detection limits of 5.2 x 10(-5) (LSV), 5.0 x 10(-6) (DPV) and 5.0 x 10(-5) mol l(-1) (SWV). (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of trace basic organonitrogen compounds such as quinoline and pyridine in derivative petroleum fuels plays an important role in maintaining the engines of vehicles. However, these substances can contaminate the environment and so must be controlled because most of them are potentially carcinogenic and mutagenic. For these reasons, a reliable and sensitive method was developed for the determination of basic nitrogen compounds in fuel samples such as gasoline and diesel. This method utilizes preconcentration on an ion-exchange resin (Amberlyte IR - 120 H) followed by differential pulse voltammetry (DPV) on a glassy carbon electrode. The electrochemical behavior of quinoline and pyridine as studied by cyclic voltammetry (CV) suggests that their reduction occurs via a reversible electron transfer followed by an irreversible chemical reaction. Very well resolved diffusion-controlled voltammetric peaks were obtained in dimethylformamide (DMF) with tetrabutylammonium tetrafluoroborate (TBAF(4) 0.1 mol L-1) for quinoline (-1.95 V) and pyridine (-2.52 V) vs. Ag vertical bar AgCl vertical bar KClsat reference electrode. The proposed DPV method displayed a good linear response from 0.10 to 300 mg L-1 and a limit of detection (LOD) of 5.05 and 0.25 mu g L-1 for quinoline and pyridine, respectively. Using the method of standard additions, the simultaneous determination of quinoline and pyridine in gasoline samples yielded 25.0 +/- 0.3 and 33.0 +/- 0.7 mg L-1 and in diesel samples yielded 80.3 +/- 0.2 and 131 +/- 0.4 mg L-1, respectively. Spike recoveries were 94.4 +/- 0.3% and 10 +/- 0.5% for quinoline and pyridine, respectively, in the fuel determinations. This proposed method was also compared with UV-vis spectrophotometric measurements. Results obtained for the two methods agreed well based on F and t student's tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents an electroanalytical method based on square-wave voltammetry (SWV) for the determination of quinizarine (QNZ) in a mixture of Britton-Robinson buffer 0.08 mol L-1 with 30% of acetonitrile. The QNZ was oxidized at glassy carbon electrode in and the well-defined peak at +0.45 V vs. Ag/AgCl can be used for its determination as colour marker in fuel samples. All parameters were optimized and analytical curves can be constructed for QNZ concentrations ranging from 2.0 x 10(-6) mol L-1 to 1.4 x 10(-5) mol L-1, using f = 60 Hz and E-sw = 25 mV. The method offers a limit detection of 4.12 x 10(-7) mol L-1 and a standard deviation of 4.5% when six measurements of 1.25 x 10(-5) mol L-1 are compared. The method was successfully applied for determining QNZ in gasoline and diesel oil and the obtained results showed good agreement with those reported previously. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An amperometric biosensor for salicylate detection was developed by immobilizing salicylate hydroxylase via glutaraldehyde onto a polypyrrole film doped with hexacyanoferrate, supported on a glassy carbon electrode surface. The sensor monitors the catechol produced in the enzymatic reaction on the film surface, at an applied potential of 150 mV vs. SCE. A [NADH]/[salicylate] ratio between 2 and 4 gave the best response. The biosensor presented the best performance in a solution with pH=7.4. The response time was about 40 s. A linear range of response was observed for salicylate concentrations between 1.0x10(-5) and 1.0x10(-4) mol l(-1) and the equation adjusted for this curve was I=(-0.04+/-0.01)+(11.4+/-0.2)[salicylate] with a correlation coefficient of 0.999 for n=6. The biosensor retains its activity for at least 10 days despite daily use. The results obtained using the biosensor for salicylate determination, in three different samples of antithermic drugs, presented a good correlation with the standard colorimetric method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sodium nitroprusside (NP), a commercial vasodilator, can be pre-concentrated on vitreous carbon electrode modified by films of 97.5%: 2.5% Poly-L-lysine (PLL): glutaraldehyde (GA). This coating gives acceptable anion exchange properties whilst giving the required improvement of adhesion to the glassy carbon electrode surface. Linear response range and detection limit on nitroprusside in B-R buffer pH 4.0, were 1 x 10(-6) to 2 x 10-(5) mol L-1 and 1 x 10(-7) mol L-1, respectively. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was measured as 4.1% for 10 experiments. The voltammetric sensor was directly applied to determination of nitroprusside in human plasma and urine samples and the average recovery for these samples was around 95-97% without any pre treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of trace neutral organonitrogen compounds as carbazole and indole in derivative petroleum fuels plays an important role in the car's engine maintenance. In addition, these substances contribute to the environmental contamination and their control is necessary because most of them are potentially carcinogenic and mutagenic. For those reasons, a reliable and sensitive method was proposed for the determination of neutral nitrogen compounds in fuel samples, such as gasoline and diesel using preconcentration with modified silica gel (Merck 70-230 mesh ASTM) followed by differential pulse voltammetry (DPV) technique on a glassy carbon electrode. The electrochemical behavior of carbazole and indole studied by cyclic voltammetry (CV) suggests that their reduction occurs via a reversible electron transfer followed by an irreversible chemical reaction. Very well resolved diffusion controlled voltammetric peaks were obtained in dimethylformamide (DMF) with tetrabutylammonium tetrafluoroborate (TBAF(4) 0.1 mol L-1) for indole (-2.27 V) and carbazole (-2.67 V) versus Ag vertical bar AgCl vertical bar KClsat reference electrode. The proposed DPV method showed a good linear response range from 0.10 to 300 mg L-1 and a limit of detection (L.O.D) of 7.48 and 2.66 mu g L-1 for indole and carbazole, respectively. The results showed that simultaneous determination of indole and carbazole presents in spiked gasoline samples were 15.8 +/- 0.3 and 64.6 +/- 0.9 mg L-1 and in spiked diesel samples were 9.29 +/- 1 and 142 +/- 1 mg L-1, respectively. The recovery was evaluated and the results shown the values of 88.9 +/- 0.4 and 90.2 +/- 0.8% for carbazole and indole in fuel determinations. The proposed method was also compared with UV-vis spectrophotometric measures and the results obtained for the two methods were in good agreement according to the F and t Student's tests. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid inexpensive voltammetric method have been developed for the quantitative determination of albendazole (ABZ) as the pure assay, by direct dissolution of commercial tablets in HCl solutions. Studies with linear sweep (LSV), square-wave (SWV) and differential pulse voltammetry (DPV) were carried out ABZ in aqueous medium at a glassy carbon electrode. A well defined irreversible oxidation peak current was obtained at 1,00V vs. SCE. The method permits a precise quantitative determination of ABZ using the standard addition method. The detection limits for the three voltammetric techniques were found to be 3.0 x 10(-5) M (LSV), 6.2 x 10(-5) M (SWV) and 4.0 x 10(-5) M (DPV).