857 resultados para control strategy
Resumo:
Controlling Armillaria infections by physical and chemical methods alone is at present inadequate, ineffective, or impractical. Effective biological control either alone or in integration with another control strategy appears necessary. Biological control agents of Armillaria function by the antagonists inhibiting or preventing its rhizomorphic and mycelial development, by limiting it to substrate already occupied, by actively pre-empting the substrate, or by eliminating the pathogen from substrate it has already occupied. Among the most thoroughly investigated antagonists of Armillaria are Trichoderma species. Depending on the particular isolate of a Trichoderma species, control may be achieved by competition, production of antibiotics, or by mycoparasitism. The level of control is also influenced by the growth and carrier substrate of the antagonist, time of application in relation to the occurrence of the disease, and several environmental conditions. Among a range of the other antagonists are several cord-forming fungi and an isolate of Dactylium dendroides. Integrating biological methods with an appropriate method of chemical could control the disease more effectively. However it is essential to determine whether the antagonist or the fungicide should be applied first, and the time interval between.
Resumo:
A self-tuning controller which automatically assigns weightings to control and set-point following is introduced. This discrete-time single-input single-output controller is based on a generalized minimum-variance control strategy. The automatic on-line selection of weightings is very convenient, especially when the system parameters are unknown or slowly varying with respect to time, which is generally considered to be the type of systems for which self-tuning control is useful. This feature also enables the controller to overcome difficulties with non-minimum phase systems.
Resumo:
A semiochemical based push-pull strategy for control of oilseed rape pests is being developed at Rothamsted Research. This strategy uses insect and plant derived semiochemicals to manipulate pests and their natural enemies. An important element within this strategy is an understanding of the importance of non-host plant cues for pest insects and how such signals could be used to manipulate their behaviour. Previous studies using a range of non-host plants have shown that, for the pollen beetle Meligethes aeneus (Coleoptera: Nitidulidae), the essential oil of lavender, Lavandula angustifolia (Lamiaceae), was the most repellent. The aim of this study was to identify the active components in L. angustifolia oil, and to investigate the behaviour of M. aeneus to these chemicals, to establish the most effective use of repellent stimuli to disrupt colonisation of oilseed rape crops. Coupled gas chromatography-electroantennography (GC-EAG) and gas chromatography-mass spectrometry (GC-MS) resulted in the identification of seven active compounds which were tested for behavioural activity using a 4-way olfactometer. Repellent responses were observed with (±)-linalool and (±)-linalyl acetate. The use of these chemicals within a push-pull pest control strategy is discussed.
Resumo:
Anticoagulants rodenticides have already known for over half a century, as effective and safe method of rodent control. However, discovered in 1958 anticoagulant resistance has given us a very important problem for their future long-term use. Laboratory tests provide the main method for identification the different types of anticoagulant resistances, quantify the magnitude of their effect and help us to choose the best pest control strategy. The main important tests are lethal feeding period (LFP) and blood clotting response (BCR) tests. These tests can now be used to quantify the likely effect of the resistance on treatment outcome by providing an estimate of the ‘resistance factor’. In 2004 the gene responsible for anticoagulant resistance (VKORC1) was identified and sequenced. As a result, a new molecular resistance testing methodology has been developed, and a number of resistance mutations, particularly in Norway rats and house mice. Three mutations of the VKORC1 gene in Norway rats have been identified to date that confer a degree of resistance to bromadiolone and difenacoum, sufficient to affect treatment outcome in the field.
Resumo:
The study reported here is part of a large project for evaluation of the Thermo-Chemical Accumulator (TCA), a technology under development by the Swedish company ClimateWell AB. The studies concentrate on the use of the technology for comfort cooling. This report concentrates on measurements in the laboratory, modelling and system simulation. The TCA is a three-phase absorption heat pump that stores energy in the form of crystallised salt, in this case Lithium Chloride (LiCl) with water being the other substance. The process requires vacuum conditions as with standard absorption chillers using LiBr/water. Measurements were carried out in the laboratories at the Solar Energy Research Center SERC, at Högskolan Dalarna as well as at ClimateWell AB. The measurements at SERC were performed on a prototype version 7:1 and showed that this prototype had several problems resulting in poor and unreliable performance. The main results were that: there was significant corrosion leading to non-condensable gases that in turn caused very poor performance; unwanted crystallisation caused blockages as well as inconsistent behaviour; poor wetting of the heat exchangers resulted in relatively high temperature drops there. A measured thermal COP for cooling of 0.46 was found, which is significantly lower than the theoretical value. These findings resulted in a thorough redesign for the new prototype, called ClimateWell 10 (CW10), which was tested briefly by the authors at ClimateWell. The data collected here was not large, but enough to show that the machine worked consistently with no noticeable vacuum problems. It was also sufficient for identifying the main parameters in a simulation model developed for the TRNSYS simulation environment, but not enough to verify the model properly. This model was shown to be able to simulate the dynamic as well as static performance of the CW10, and was then used in a series of system simulations. A single system model was developed as the basis of the system simulations, consisting of a CW10 machine, 30 m2 flat plate solar collectors with backup boiler and an office with a design cooling load in Stockholm of 50 W/m2, resulting in a 7.5 kW design load for the 150 m2 floor area. Two base cases were defined based on this: one for Stockholm using a dry cooler with design cooling rate of 30 kW; one for Madrid with a cooling tower with design cooling rate of 34 kW. A number of parametric studies were performed based on these two base cases. These showed that the temperature lift is a limiting factor for cooling for higher ambient temperatures and for charging with fixed temperature source such as district heating. The simulated evacuated tube collector performs only marginally better than a good flat plate collector if considering the gross area, the margin being greater for larger solar fractions. For 30 m2 collector a solar faction of 49% and 67% were achieved for the Stockholm and Madrid base cases respectively. The average annual efficiency of the collector in Stockholm (12%) was much lower than that in Madrid (19%). The thermal COP was simulated to be approximately 0.70, but has not been possible to verify with measured data. The annual electrical COP was shown to be very dependent on the cooling load as a large proportion of electrical use is for components that are permanently on. For the cooling loads studied, the annual electrical COP ranged from 2.2 for a 2000 kWh cooling load to 18.0 for a 21000 kWh cooling load. There is however a potential to reduce the electricity consumption in the machine, which would improve these figures significantly. It was shown that a cooling tower is necessary for the Madrid climate, whereas a dry cooler is sufficient for Stockholm although a cooling tower does improve performance. The simulation study was very shallow and has shown a number of areas that are important to study in more depth. One such area is advanced control strategy, which is necessary to mitigate the weakness of the technology (low temperature lift for cooling) and to optimally use its strength (storage).
Resumo:
Test method for integrated solar- biomass systems - Long term prediction trough short term measurementsSP Technical Research Institute of Sweden and SERC, Dalarna University have in cooperation developed a test method for integrated solar and biomass systems. The test method is performed under six days including two summer days, two winter days and two spring/autumn days true to real weather conditions and loads for a single family house. The aim of the test method is to get information about a Combisystem’s annual performance and operation throughout a short term test. Seven different solar Combisystems have been tested within the project together with a pellet boiler without solar collectors. In addition to that a comparative testing has been performed at the two laboratories at SP and at SERC on the same Combisystem. The test method developed within the project has been proved to withstand the aim of the project, which is to be able to compare the performance between the systems. The test method is also suitable for identification of possible operation problems so they can be taken care of and consequently improves the system.The project and the system testing reveal that it is in general favorable to combine biomass pellets with solar heating. Pellet boilers has normally a low performance during the summer period but combined with a solar collector the boiler can be switch off during this period. There are however big differences in performance between the tested. The efficiency of the pellet boiler is highly dependent of the operating conditions and elements like heat losses from the system, system configuration and control strategy have great influence of the performance of the system and the emissions. On the other hand, the performance and the size of the solar collectors have a minor effect on the overall system performance. There is obviously a big potential for improvement of the system´s performance and the developed test method is an essential way to implement this perfection.
Resumo:
In Sweden, there are about 0.5 million single-family houses that are heated by electricity alone, and rising electricity costs force the conversion to other heating sources such as heat pumps and wood pellet heating systems. Pellet heating systems for single-family houses are currently a strongly growing market. Future lack of wood fuels is possible even in Sweden, and combining wood pellet heating with solar heating will help to save the bio-fuel resources. The objectives of this thesis are to investigate how the electrically heated single-family houses can be converted to pellet and solar heating systems, and how the annual efficiency and solar gains can be increased in such systems. The possible reduction of CO-emissions by combining pellet heating with solar heating has also been investigated. Systems with pellet stoves (both with and without a water jacket), pellet boilers and solar heating have been simulated. Different system concepts have been compared in order to investigate the most promising solutions. Modifications in system design and control strategies have been carried out in order to increase the system efficiency and the solar gains. Possibilities for increasing the solar gains have been limited to investigation of DHW-units for hot water production and the use of hot water for heating of dishwashers and washing machines via a heat exchanger instead of electricity (heat-fed appliances). Computer models of pellet stoves, boilers, DHW-units and heat-fed appliances have been developed and the parameters for the models have been identified from measurements on real components. The conformity between the models and the measurements has been checked. The systems with wood pellet stoves have been simulated in three different multi-zone buildings, simulated in detail with heat distribution through door openings between the zones. For the other simulations, either a single-zone house model or a load file has been used. Simulations were carried out for Stockholm, Sweden, but for the simulations with heat-fed machines also for Miami, USA. The foremost result of this thesis is the increased understanding of the dynamic operation of combined pellet and solar heating systems for single-family houses. The results show that electricity savings and annual system efficiency is strongly affected by the system design and the control strategy. Large reductions in pellet consumption are possible by combining pellet boilers with solar heating (a reduction larger than the solar gains if the system is properly designed). In addition, large reductions in carbon monoxide emissions are possible. To achieve these reductions it is required that the hot water production and the connection of the radiator circuit is moved to a well insulated, solar heated buffer store so that the boiler can be turned off during the periods when the solar collectors cover the heating demand. The amount of electricity replaced using systems with pellet stoves is very dependant on the house plan, the system design, if internal doors are open or closed and the comfort requirements. Proper system design and control strategies are crucial to obtain high electricity savings and high comfort with pellet stove systems. The investigated technologies for increasing the solar gains (DHW-units and heat-fed appliances) significantly increase the solar gains, but for the heat-fed appliances the market introduction is difficult due to the limited financial savings and the need for a new heat distribution system. The applications closest to market introduction could be for communal laundries and for use in sunny climates where the dominating part of the heat can be covered by solar heating. The DHW-unit is economical but competes with the internal finned-tube heat exchanger which is the totally dominating technology for hot water preparation in solar combisystems for single-family houses.
Resumo:
This dissertation synthesizes previous research and develops a model for the study of strategic development, strategic congruence and management control. The model is used to analyze a longitudinal case study of the Swedish engineering company Atlas Copco. Employing contingency theory, the study confirms that long-term survival of a company requires adaption to contingencies. Three levels of strategy are examined: corporate, business and functional. Previous research suggests that consistency between these levels (strategic congruence) is necessary for a company to be competitive. The dissertation challenges this proposition by using a life-cycle perspective and analyzes strategic congruence in the different phases of a life cycle. It also studies management control from a life-cycle perspective. In this context, two types of management control are examined: formal and informal. From a longitudinal perspective, the study further discusses how these types interact during organizational life cycles. The dissertation shows that strategic development is more complex than previous studies have indicated. It is a long, complex and non-linear process, the results of which cannot always be predicted. Previous models for strategy and management control are based on simple relationships and rarely take into account the fact that companies often go through different phases of strategic development. The case study shows that strategic incongruence may occur at times during organizational life cycles. Furthermore, the use of management control varies over time. In the maturity phase, formal control is in focus, while the use of informal control has a bigger role in both the introduction and decline phases. Research on strategy and management control has intensified in recent years. Still there is a gap regarding the coordination of complex corporate structures. The present study contributes with further knowledge on how companies manage long-term strategic development. Few studies deal with more than two levels of strategy. Moreover, the present study addresses the need to understand strategic congruence from a life-cycle perspective. This is particularly relevant in practice, when management in large companies face difficult issues for which they expect business research to assist them in the decision-making process.
Resumo:
Renewable energy production is a basic supplement to stabilize rapidly increasing global energy demand and skyrocketing energy price as well as to balance the fluctuation of supply from non-renewable energy sources at electrical grid hubs. The European energy traders, government and private company energy providers and other stakeholders have been, since recently, a major beneficiary, customer and clients of Hydropower simulation solutions. The relationship between rainfall-runoff model outputs and energy productions of hydropower plants has not been clearly studied. In this research, association of rainfall, catchment characteristics, river network and runoff with energy production of a particular hydropower station is examined. The essence of this study is to justify the correspondence between runoff extracted from calibrated catchment and energy production of hydropower plant located at a catchment outlet; to employ a unique technique to convert runoff to energy based on statistical and graphical trend analysis of the two, and to provide environment for energy forecast. For rainfall-runoff model setup and calibration, MIKE 11 NAM model is applied, meanwhile MIKE 11 SO model is used to track, adopt and set a control strategy at hydropower location for runoff-energy correlation. The model is tested at two selected micro run-of-river hydropower plants located in South Germany. Two consecutive calibration is compromised to test the model; one for rainfall-runoff model and other for energy simulation. Calibration results and supporting verification plots of two case studies indicated that simulated discharge and energy production is comparable with the measured discharge and energy production respectively.
Resumo:
O presente trabalho visou identificar as percepções dos profissionais de TI, em uma empresa de petróleo brasileira, sobre o tema Governança de TI. Para isso, foi utilizada a Teoria da Representação Social (TRS), mais especificamente a Teoria do Núcleo Central inaugurada por Jean-Claude Abric. Para proceder às investigações foi utilizado um questionário online, que incluiu um teste de evocação de palavras, visando à interpretação do núcleo central da representação social. Ao todo, foram consideradas as respostas de 140 profissionais da área de TI da empresa pesquisada que responderam ao questionário. A partir do teste de evocação de palavras, foi identificada a representação social de Governança de TI, por meio da construção do quadrante de Vergés, sendo os cálculos realizados em planilhas eletrônicas com posterior confirmação pelo software EVOC. Os elementos identificados no núcleo central, responsáveis por consolidar a visão consensual do grupo, foram Controle, Estratégia, Alinhamento, Gestão, e Planejamento. Os três primeiros elementos encontram sólido respaldo na literatura sobre Governança de TI, já que os profissionais de TI tem a visão de que a Governança de TI é responsável pelo controle da área de TI, garantindo seu contínuo alinhamento à estratégia da organização. Já os elementos Gestão e Planejamento parecem estar ligados às especificidades e características mais operacionais do modelo de Governança de TI implantado na empresa pesquisada, sugerindo uma falta de clareza na distinção entre os conceitos Gestão e Governança de TI. Em relação aos elementos periféricos, foram encontradas as expressões Decisão, Diretrizes e Padronização. Alguns elementos como Decisão, Direção e Responsabilidades, de acordo com a literatura, apresentam relevância para o conceito de Governança de TI, mas não foram identificados no núcleo central. Adicionalmente, não foi indicada qualquer expressão relacionada a mecanismos de relacionamento, os quais, de acordo com a Academia, são elementos fundamentais e necessários a uma efetiva Governança de TI. Também não foram identificados outros elementos destacados pela literatura, como a noção de que a Governança de TI é responsável por garantir que os investimento em TI gerem valor, gerenciar o desempenho da TI e gerir os riscos existentes pelo uso de TI na organização. Compreender a representação social de Governança de TI pode ajudar a explicar o comportamento da organização analisada em relação a diversos aspectos da Governança de TI, permitindo a identificação de oportunidades de melhoria do modelo atualmente adotado.
Resumo:
The control of Pratylenchus goodeyi a common nematode parasite of banana crop in Madeira Island can benefit from searching for natural nematicides through plants extracts. With this aim we submitted Solanum nigrum and S. sisymbriifolium dried plants to a sequential extraction in the solvent sequence of dichloromethane, acetone, ethanol and water, and to na aqueous extraction of the fresh and dried plants. Analyses with the extracts at several concentrations were used to assess mobility and mortality on P. goodeyi. Results showed that the water extract and aqueous extracts from both plants at a concentration of 10 mg/mL affected nematode mobility and caused mortality but the acetone extract from S. nigrum was the most efficient, causing 100% mortality whereas dichloromethane had no effect on P. goodeyi. Determination of the lipophilic and phenolic compounds present in the two most effective Solanum extracts (acetone and water) and in dichloromethane extract revealed that some of these compounds had nematicidal activity. S. nigrum acetone extract (10 mg/mL) was used to find out the nematicidal potential following the effect at gene expression level and nematode behaviour. Genes coding for calreticulin and beta-1,4- endoglucanase related to parasitism and translocon-associated protein putatively connected to stress were obtained and its relative expression assessed in nematodes exposed to the extract. Results revealed that expression of Pg-CRT decreased showing to influence the infection, Pg-ENG remained steady and Pg-TRAPδ was induced over time exposure. Biological assays showed that P. goodeyi mobility and ability to infect the banana roots were affected as a decrease in the number of nematodes that reached the roots was obtained with the increased exposure time to the extract being implicated in the infection success. The information obtained from this thesis showed that S. nigrum has potential to be used for the development of a new control strategy against plant-parasitic nematodes.
Resumo:
The Electrical Submersible Pumping is an artificial lift method for oil wells employed in onshore and offshore areas. The economic revenue of the petroleum production in a well depends on the oil flow and the availability of lifting equipment. The fewer the failures, the lower the revenue shortfall and costs to repair it. The frequency with which failures occur depends on the operating conditions to which the pumps are submitted. In high-productivity offshore wells monitoring is done by operators with engineering support 24h/day, which is not economically viable for the land areas. In this context, the automation of onshore wells has clear economic advantages. This work proposes a system capable of automatically control the operation of electrical submersible pumps, installed in oil wells, by an adjustment at the electric motor rotation based on signals provided by sensors installed on the surface and subsurface, keeping the pump operating within the recommended range, closest to the well s potential. Techniques are developed to estimate unmeasured variables, enabling the automation of wells that do not have all the required sensors. The automatic adjustment, according to an algorithm that runs on a programmable logic controller maintains the flow and submergence within acceptable parameters avoiding undesirable operating conditions, as the gas interference and high engine temperature, without need to resort to stopping the engine, which would reduce the its useful life. The control strategy described, based on modeling of physical phenomena and operational experience reported in literature, is materialized in terms of a fuzzy controller based on rules, and all generated information can be accompanied by a supervisory system
Resumo:
O conhecimento da composição específica do banco de sementes de plantas daninhas e a sua correlação com a flora estabelecida são importantes para nortear o manejo a ser adotado e a escolha dos herbicidas. A colheita mecanizada de cana-de-açúcar acarretou mudanças significativas na composição da flora infestante, quando proporcionou a manutenção de uma camada de palha, reduziu a movimentação do solo e dispensou a prática da queimada. Foram realizados levantamentos do banco de sementes e da flora de plantas daninhas que se estabeleceu em 28 talhões colhidos mecanicamente, sem queima prévia da palha. Com base nos dados de banco de sementes, efetuaram-se estudos fitossociológicos e de correlação entre a composição do banco de sementes e a flora emergida. As principais espécies presentes no banco de sementes foram as pertencentes à classe das dicotiledôneas anuais, com destaque para Amaranthus spp. e diversas espécies de Euphorbiaceae e Convolvulaceae. As sementes de gramíneas tradicionais da cultura tiveram pouca participação. O banco de sementes apresentou correlação não-significativa com a flora emergente, independentemente da época de colheita do talhão, da metodologia de quantificação do banco de sementes e das espécies de plantas daninhas.
Resumo:
The so-called Dual Mode Adaptive Robust Control (DMARC) is proposed. The DMARC is a control strategy which interpolates the Model Reference Adaptive Control (MRAC) and the Variable Structure Model Reference Adaptive Control (VS-MRAC). The main idea is to incorporate the transient performance advantages of the VS-MRAC controller with the smoothness control signal in steady-state of the MRAC controller. Two basic algorithms are developed for the DMARC controller. In the first algorithm the controller's adjustment is made, in real time, through the variation of a parameter in the adaptation law. In the second algorithm the control law is generated, using fuzzy logic with Takagi-Sugeno s model, to obtain a combination of the MRAC and VS-MRAC control laws. In both cases, the combined control structure is shown to be robust to the parametric uncertainties and external disturbances, with a fast transient performance, practically without oscillations, and a smoothness steady-state control signal
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system