956 resultados para constant pressure heat capacity
Resumo:
We conduct a theoretical analysis of steady-state heat transfer problems through mid-crustal vertical cracks with upward throughflow in hydrothermal systems. In particular, we derive analytical solutions for both the far field and near field of the system. In order to investigate the contribution of the forced advection to the total temperature of the system, two concepts, namely the critical Peclet number and the critical permeability of the system, have been presented and discussed in this paper. The analytical solution for the far field of the system indicates that if the pore-fluid pressure gradient in the crust is lithostatic, the critical permeability of the system can be used to determine whether or not the contribution of the forced advection to the total temperature of the system is negligible. Otherwise, the critical Peclet number should be used. For a crust of moderate thickness, the critical permeability is of the order of magnitude of 10(-20) m(2), under which heat conduction is the overwhelming mechanism to transfer heat energy, even though the pore-fluid pressure gradient in the crust is lithostatic. Furthermore, the lower bound analytical solution for the near field of the system demonstrates that the permeable vertical cracks in the middle crust can efficiently transfer heat energy from the lower crust to the upper crust of the Earth. Copyright (C) 2002 John Wiley Sons, Ltd.
Resumo:
Positive end expiratory pressure (PEEP) is important for neonatal ventilation but is not considered in guidelines for resuscitation. Our aim was to investigate the effects of PEEP on cardiorespiratory parameters during resuscitation of very premature lambs delivered by hysterotomy at similar to125 d gestation (term similar to147 d). Before delivery, they were intubated and lung fluid was drained. Immediately after delivery, they were ventilated with a Drager Babylog plus ventilator in volume guarantee mode with a tidal volume of 5 mL/kg. Lambs were randomized to receive 0, 4, 8, or 12 cm H2O of PEEP. They were ventilated for a 15-min resuscitation period followed by 2 h of stabilization at the same PEEP. Tidal volume, peak inspiratory pressure, PEEP, arterial pressure, oxygen saturation, and blood gases were measured regularly, and respiratory system compliance and alveolar/ arterial oxygen differences were calculated. Lambs that received 12 cm H2O of PEEP died from pneumothoraces; all others survived without pneumothoraces. Oxygenation was significantly improved by 8 and 12 cm H2O of PEEP compared with 0 and 4 cm H2O of PEEP. Lambs with 0 PEEP did not oxygenate adequately. The compliance of the respiratory system was significantly higher at 4 and 8 cm H2O of PEEP than at 0 PEEP. There were no significant differences in partial pressure of carbon dioxide in arterial blood between groups. Arterial pressure was highest with 8 cm H2O of PEEP, and there was no cardiorespiratory compromise at any level of PEEP. Applying PEEP during resuscitation of very premature infants might be advantageous and merits further investigation.
Resumo:
The thermal characteristics of a colony of Apoica flavissima, an epiponine wasp, were examined. The nest, with a diameter of slightly less than 30 cm, was built on a twig of an orange tree. The temperature of the roof surface fluctuated greatly, ranging between 19.1 and 41.5 degrees C. However, the temperature in the central cell was kept constant at around 27 degrees C throughout a day. Although heavy rain pelted the nest roof in the morning, the central cell maintained temperatures higher than 25 degrees C. On the contrary, after all immature and adult wasps were removed the temperature in the nest fluctuated considerably. The presence of immature individuals and adult wasps densely covering the under surface of the comb seemed to function as an effective insulator. The smaller temperature fluctuation in the central cell than on the roof surface, when the nest was in the empty state, suggests that the thick spongy tissue of the roof made from curled plant leaf hairs serves as an insulator to prevent the conduction of solar heat into the cells and the outward flow of heat generated in cells, especially at night.
Resumo:
Background: Guidelines recommend neonatal resuscitation without controlling tidal volume or positive end-expiratory pressure (PEEP). However, these may improve gas exchange, lung volume and outcome. Aim: To investigate resuscitation of very premature lambs with a Laerdal bag without PEEP versus volume guarantee ventilation with PEEP. Methods: Anaesthetized lambs (n = 20) delivered at 125 d gestation were randomized to three groups receiving 15 min resuscitation: (1) Laerdal bag and no PEEP; (2) ventilation with a tidal volume of 5 ml/kg and 8 cm H2O PEEP; (3) ventilation with 10 ml/kg and 8 cm H2O PEEP. They were then all ventilated for 2 h with tidal volumes of 5 or 10 ml/kg, and 8 cm H2O PEEP. Ventilation parameters and blood gases were recorded. Results: Different tidal volumes affected PaCO2 within minutes, with 10 ml/kg causing severe hypocarbia. PEEP had little effect on PaCO2. Oxygenation improved significantly with PEEP of 8 cm H2O, irrespective of tidal volume. Conclusion: Very premature lambs can be resuscitated effectively using volume-guarantee ventilation and PEEP. Tidal volumes affected PaCO2 within minutes but had little effect on oxygenation. PEEP halved the oxygen requirement compared with no PEEP. Resuscitating premature babies with controlled tidal volumes and PEEP might improve their outcome.
Resumo:
An experimental study of the effect of fuel stagnation temperature on mixing in a supersonic hydrogen-air flame is described, The combustor consisted of a constant-area rectangular duct with a centrally located fuel-injection strut that spanned the width. A high-enthalpy stream of air was supplied by a free-piston shock tunnel, and heated hydrogen fuel, supplied by a gun-tunnel, was injected into the freestream as a coflowing planar jet. The freestream total enthalpies were 5.6, 6.5, and 9 MJ/kg, and fuel stagnation temperatures were 300, 450, and 700 K, Raising the fuel stagnation temperature increased the fuel velocity to be near that of the airstream and resulted in a decrease in the mixing rate, Even as the fuel and air velocities became equal, significant mixing still occurred because of a large difference in density, Increasing the freestream enthalpy reduced the difference between the initial air temperature and the adiabatic flame temperature, which in turn reduced the heat addition, and subsequently, the amount of pressure rise in the duct.
Resumo:
Exercise is an effective intervention for treating hypertension and arterial stiffness, but little is known about which exercise modality is the most effective in reducing arterial stiffness and blood pressure in hypertensive subjects. Our purpose was to evaluate the effect of continuous vs. interval exercise training on arterial stiffness and blood pressure in hypertensive patients. Sixty-five patients with hypertension were randomized to 16 weeks of continuous exercise training (n=26), interval training (n=26) or a sedentary routine (n=13). The training was conducted in two 40-min sessions a week. Assessment of arterial stiffness by carotid-femoral pulse wave velocity (PWV) measurement and 24-h ambulatory blood pressure monitoring (ABPM) were performed before and after the 16 weeks of training. At the end of the study, ABPM blood pressure had declined significantly only in the subjects with higher basal values and was independent of training modality. PWV had declined significantly only after interval training from 9.44 +/- 0.91 to 8.90 +/- 0.96 m s(-1), P=0.009 (continuous from 10.15 +/- 1.66 to 9.98 +/- 1.81 m s(-1), P-ns; control from 10.23 +/- 1.82 to 10.53 +/- 1.97 m s(-1), P-ns). Continuous and interval exercise training were beneficial for blood pressure control, but only interval training reduced arterial stiffness in treated hypertensive subjects. Hypertension Research (2010) 33, 627-632; doi:10.1038/hr.2010.42; published online 9 April 2010
Resumo:
Endomyocardial fibrosis (EMF) is a restrictive cardiomyopathy manifested mainly by diastolic heart failure. It is recognized that diastole is an important determinant of exercise capacity. The purpose of this study was to determine whether resting echocardiographic parameters might predict oxygen consumption (VO(2p)) by ergoespirometry and the prognostic role of functional capacity in EMF patients. A total of 32 patients with biventricular EMF (29 women, 55.3 +/- 11.4 years) were studied by echocardiography and ergoespirometry. The relationship between the echocardiographic indexes and the percentage of predicted VO(2p) (%VO(2p)) was investigated by the `stepwise` linear regression analysis. The median VO(2p) was 11 +/- 3 mL/kg/min and the %VO(2p) was 53 +/- 9%. There was a correlation of %VO(2p) with an average of A` at four sites of the mitral annulus (A` peak, r = 0.471, P = 0.023), E`/A` of the inferior mitral annulus (r = -0.433, P = 0.044), and myocardial performance index (r = -0.352, P = 0.048). On multiple regression analysis, only A` peak was an independent predictor of %VO(2p) (%VO(2p)= 26.34 + 332.44 x A` peak). EMF patients with %VO(2p)< 53% had an increased mortality rate with a relative risk of 8.47. In EMF patients, diastolic function plays an important role in determining the limitations to exercise and %VO(2p) has a prognostic value.
Resumo:
Background: Despite antihypertensive therapy, it is difficult to maintain optimal systemic blood pressure (BP) values in hypertensive patients (HPT). Exercise may reduce BP in untreated HPT. However, evidence regarding its effect in long-term antihypertensive therapy is lacking. Our purpose was to evaluate the acute effects of 40-minute continuous (CE) or interval exercise (IE) using cycle ergometers on BP in long-term treated HPT. Methods: Fifty-two treated HPT were randomized to CE (n=26) or IE (n=26) protocols. CE was performed at 60% of reserve heart rate (HR). IE alternated consecutively 2 min at 50% reserve HR with 1 min at 80%. Two 24-h ambulatory BP monitoring were made after exercise (postexercise) or a nonexercise control period (control) in random order. Results: CE reduced mean 24-h systolic (S) BP (2.6 +/- 6.6 mm Hg, p-0.05) and diastolic (D) BP (2.3 +/- 4.6, p-0.01), and nighttime SBP (4.8 +/- 6.4, p < 0.001) and DBP (4.6 +/- 5.2 mm Hg, p-0.001). IE reduced 24-h SBP (2.8 +/- 6.5, p-0.03) and nighttime SBP (3.4 +/- 7.2, p-0.02), and tended to reduce nighttime DBP (p=0.06). Greater reductions occurred in higher BP levels. Percentage of normal ambulatory BP values increased after CE (24-h: 42% to 54%; daytime: 42% to 61%; nighttime: 61% to 69%) and IE (24-h: 31% to 46%; daytime: 54% to 61%; nighttime: 46% to 69%). Conclusion: CE and IE reduced ambulatory BP in treated HPT, increasing the number of patients reaching normal ambulatory BP values. These effects suggest that continuous and interval aerobic exercise may have a role in BP management in treated HPT. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The standard critical power test protocol on the cycle prescribes a series of trials to exhaustion, each at a different but constant power setting. Recently the protocol has been modified and applied to a series of trials to exhaustion each at a different ramp incremental rate. This study was undertaken to compare critical power and anaerobic work capacity estimates in the same group of subjects when derived from the two protocols. Ten male subjects of mixed athletic ability cycled to exhaustion on eight occasions in randomized order over a 3-wk period. Four trials were performed at differing constant power settings and four trials on differing ramp incremental rates. Both critical power and anaerobic work capacity were estimated for each subject by curve fitting of the ramp model and of three versions of the constant power model. After adjusting for inter-subject variability, no significant differences were detected between critical power estimates or between anaerobic work capacity estimates from any model formulation or from the two protocols. It is concluded that both the ramp and constant power protocols produce equivalent estimates for critical power and anaerobic work capacity.
Resumo:
Severe obesity has been associated with adverse effects on physical capacity. In a prospective study, the aerobic capacity of severely obese patients was measured in order to observe the physiological response to weight loss from bariatric surgery. Sixty-five consecutive patients (40.4 +/- 8.4 years old; 93.8% female; body mass index = 49.4 +/- 5.4 kg/m(2)) were evaluated before bariatric surgery and then 6 and 12 months after surgery. Aerobic capacity was assessed with a scientific treadmill to measure maximal oxygen consumption (VO(2max)), heart rate, blood pressure, time on the treadmill, and distance walked (modified Bruce test). For the three observational periods, VO(2max) was 25.4 +/- 9.3, 29.8 +/- 8.1, and 36.7 +/- 8.3 ml/kg/min; time on the treadmill was 5.4 +/- 1.4, 6.4 +/- 1.6, and 8.8 +/- 1.0 min; and distance walked was 401.8 +/- 139.1, 513.4 +/- 159.9, and 690.5 +/- 76.2 m. For these variables, significant results (p = 0.0000) were observed for the two postoperative periods in relation to the preoperative period. Severely obese individuals increased their aerobic capacity after successful bariatric surgery. The data also suggests that a positive and progressive relationship between weight loss and improvement in fitness as a moderate loss of weight 6 months after surgery already showed some benefit and an additional reduction in weight was associated with a better performance in the aerobic capacity tests at the 12-month follow-up.
Resumo:
Objective: To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Design: Prospective, randomized, and controlled experimental study. Setting: University research laboratory. Subjects: Wistar rats were randomly assigned to control (C) [saline (0.1 ml), intraperitoneally] and ALI [paraquat (15 mg/kg), intra peritoneally] groups. Measurements and Main Results: After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H(2)O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (Delta P2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and Delta P2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. Conclusions: In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and Delta P2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful. (Crit Care Med 2009; 37:1011-1017)
Resumo:
Objective: To investigate the effects of the rate of airway pressure increase and duration of recruitment maneuvers on lung function and activation of inflammation, fibrogenesis, and apoptosis in experimental acute lung injury. Design: Prospective, randomized, controlled experimental study. Setting: University research laboratory. Subjects: Thirty-five Wistar rats submitted to acute lung injury induced by cecal ligation and puncture. Interventions: After 48 hrs, animals were randomly distributed into five groups (seven animals each): 1) nonrecruited (NR); 2) recruitment maneuvers (RMs) with continuous positive airway pressure (CPAP) for 15 secs (CPAP15); 3) RMs with CPAP for 30 secs (CPAP30); 4) RMs with stepwise increase in airway pressure (STEP) to targeted maximum within 15 secs (STEP15); and 5) RMs with STEP within 30 secs (STEP30). To perform STEP RMs, the ventilator was switched to a CPAP mode and positive end-expiratory pressure level was increased stepwise. At each step, airway pressure was held constant. RMs were targeted to 30 cm H(2)O. Animals were then ventilated for 1 hr with tidal volume of 6 mL/kg and positive end-expiratory pressure of 5 cm H(2)O. Measurements and Main Results: Blood gases, lung mechanics, histology (light and electronic microscopy), interleukin-6, caspase 3, and type 3 procollagen mRNA expressions in lung tissue. All RMs improved oxygenation and lung static elastance and reduced alveolar collapse compared to NR. STEP30 resulted in optimal performance, with: 1) improved lung static elastance vs. NR, CPAP15, and STEP15; 2) reduced alveolar-capillary membrane detachment and type 2 epithelial and endothelial cell injury scores vs. CPAP15 (p < .05); and 3) reduced gene expression of interleukin-6, type 3 procollagen, and caspase 3 in lung tissue vs. other RMs. Conclusions: Longer-duration RMs with slower airway pressure increase efficiently improved lung function, while minimizing the biological impact on lungs. (Crit Care Med 2011; 39:1074-1081)
Resumo:
Heat-shock proteins (HSPs) are currently one of the most promising targets for the development of immunotherapy against tumours and autoimmune disorders. This protein family has the capacity to activate or modulate the function of different immune system cells. They induce the activation of monocytes, macrophages and dendritic cells, and contribute to cross-priming, an important mechanism of presentation of exogenous antigen in the context of MHC class I molecules, These various immunological properties of HSP have encouraged their use in several clinical trials. Nevertheless, an important issue regarding these proteins is whether the high homology among HSPs across different species may trigger the breakdown of immune tolerance and induce autoimmune diseases. We have developed a DNA vaccine codifying the Mycobacterium leprae Hsp65 (DNAhsp65), which showed to be highly immunogenic and protective against experimental tuberculosis. Here, we address the question of whether DNAhsp65 immunization could induce pathological autoimmunity in mice. Our results show that DNAhsp65 vaccination induced antibodies that can recognize the human Hsp60 but did not induce harmful effects in 16 different organs analysed by histopathology up to 210 days after vaccination. We also showed that anti-DNA antibodies were not elicited after DNA vaccination. The results are important for the development of both HSP and DNA-based immunomodulatory agents.
Resumo:
Introduction: Fibroblasts are the most abundant cells in dental pulp. To investigate their capacity to produce the chemokines CCL3, CXCL8, and CXCL12 as well as nitric oxide (NO), we evaluated the production of these mediators in supernatants of cultured human dental pulp fibroblasts (HDPF) stimulated by heat-killed Enterococcus faecalis (HKEF). Methods: Primary cultures of HDPF were stimulated with medium alone or HKEF (1:1, 10:1, or 100:1 bacteria:fibroblast) for 1, 6, and 24 hours. Chemokines and NO were assessed through enzyme-linked immunosorbent assay and Griess reaction, respectively. Statistical analysis was performed by using analysis of variance and Tukey post test. Results: CCL3 was not detected, whereas constitutive CXCL8 was not affected. Production of CXCL12 was increased at 1 and 6 hours, and NO was increased at the concentration of 1:1 bacteria:fibroblast at 24 hours. Viability and proliferation assays did not reveal cell number differences. Conclusions: These findings demonstrate that heat-killed E. faecalis is able to increase production of CXCL12 and NO by HDPF. (J Endod 2010;36:91-94)
Resumo:
A new method of measuring heat of desorption is proposed in this Letter. The principle of the method is to measure the amount of mass released when a controlled amount of energy is supplied directly to a solid adsorbent. This is in contrast to conventional methods such as microcalorimetry, where heat released upon adsorption is measured. In this method, a quantified heat supply is generated by passing a de current through a carbon pellet, which is equilibrated with a gas phase confined in a closed vessel. As a consequence of the heating, the particle temperature is increased, resulting in partial desorption of adsorbed molecules. The variations of pellet temperature and the system pressure with respect to time are used to determine the heat of desorption as a function of loading.