Heat of desorption measured by means of electrical heat excitation
Contribuinte(s) |
DG Whitten |
---|---|
Data(s) |
01/01/2001
|
Resumo |
A new method of measuring heat of desorption is proposed in this Letter. The principle of the method is to measure the amount of mass released when a controlled amount of energy is supplied directly to a solid adsorbent. This is in contrast to conventional methods such as microcalorimetry, where heat released upon adsorption is measured. In this method, a quantified heat supply is generated by passing a de current through a carbon pellet, which is equilibrated with a gas phase confined in a closed vessel. As a consequence of the heating, the particle temperature is increased, resulting in partial desorption of adsorbed molecules. The variations of pellet temperature and the system pressure with respect to time are used to determine the heat of desorption as a function of loading. |
Identificador | |
Idioma(s) |
eng |
Publicador |
American Chemical Society |
Palavras-Chave | #Chemistry, Physical #Adsorption #C1 #250103 Colloid and Surface Chemistry #780102 Physical sciences |
Tipo |
Journal Article |