972 resultados para colorimetric


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ceramic pigments are colored inorganic substances that during the process of dispersion in the ceramic glazes and subsequent calcination, are stable against physical and chemical attack. Therefore, they are crystalline compounds applied in the ceramic industry for coloring vitreous base. In this study, the Pechini method was used for obtaining the pigment CuCr2O4 with heat treatment at the temperatures of 800, 900 and 1000 ° C. The powder pigments were characterized on their structural, morphological and colorimetric aspects. The thermal analysis conducted on an amorphous precursor in a TG / DTA indicates the weight loss in the entire temperature range investigated, with characteristic exothermic peak of the elimination of the organic composition of the precursor around 300°C. The development of the crystalline phases were investigated by XRD, using a diffractometer with Cu Ka radiation and graphite monochromator, where it was observed the presence of crystalline phases corresponding to Cr2O3 and CuCr2O4.The measurements of the specific surface area of the powders pigments were carried out in an equipment Micromeritcs, model ASAP 2000, using N2 as gas of adsorption/desorption. The colorimetric measurements of the pigments were made in a colorimeter Gretac Macbeth Color-eye spectrophotometer 2180 / 2180UV in CIELAB standards. Based on the obtained results, it can be verified the thermal stability of the powder pigments of green coloration, which enables it as an alternative to the materials currently used in the manufacture of ceramic tiles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This article describes the application and the performance of a cheap, simple and portable device that can be used for colorimetric quantitative determination of captopril (CPT) in pharmaceutical preparations. Methods: The sensor is a light detector resistor (LDR) placed into a black PTFE cell and coupled to a low cost multimeter (Ohmmeter). The instrument has been tested and is easy and fast to use. The quantitative study is based mainly on reduction of ammonium molybdate by captopril, in the presence of sulphuric acid, producing a green-yellow compound (max 407 nm). The calibration curves were obtained by plotting the electric resistance of the LDR against the CPT concentration on the range of 4.60 x 10-4 to 1.84 x 10-3 mol l-1 with a good coefficient of determination (R2 = 0.9962). Results: Statistical analysis of the obtained results showed no significant difference between the proposed methodology and the official reported method as evident from the t-test and variance ratio at 95% confidence level. Conclusion: The results of this study demonstrate that the instrument can be used for simple, accurate, precise, fast, in situ and low-cost colorimetric analysis of captopril in pharmaceuticals products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In-office dental bleaching has been subject of several studies. Generally those studies quantify through visual analysis, the shade reduction of the teeth submitted to different bleaching protocols (light sources, bleaching agent concentrations and irradiation time). The objective of this work is the determination of the influence of four irradiation protocols on the obtainment of better aesthetic results using a colorimetric spectrophotometer that quantifies color changes in each situation imposed. Forty bovine incisors were selected in function of similar anatomic characteristics; a concentrated coffee solution was used to stain the teeth. A commercial spectrophotometer was used to measure the color changes during evolution of the experiment (stain and bleaching phases) and the obtained data was analyzed by the ANOVA test. The obtained data showed the evolution of teeth color during the staining period, as well as, the color reduction that each bleaching protocol achieved. Based on our findings it is possible to conclude that bleaching protocols with larger irradiation periods did not showed significant differences when compared with shorter irradiation protocols, in that way the use of protocols with 30 min or more of consecutive irradiation are not clinically justified and also can cause several side effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)