934 resultados para capacitive cooling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bi-based (BPSCCO) superconductors have been extensively studied due to their interesting superconducting properties, especially those that present high transition temperature (T-c). In this work, superconductors of the BPSCCO system were prepared from rapid cooling process and studied under its structural and magnetic properties. Sample as-prepared shows an amorphous behavior, which is converted progressively into 2223 phase. This process permits the control of Pb or Bi loss and the crystallization of the desired phase using several heat annealing processes. The 2201 and 2212 phases were also observed as intermediate phases, before the crystallization of the 2223 phase. The superconductor obtained in this work presented a T-c around 77-K. (C) 2005 Springer Science + Business Media, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the impact of a 24-h cooling period prior to freezing on domestic cat epididymal sperm viability. Fifteen tomcats were submitted to routine orchiectomy and sperm samples were retrieved from both epididymides in a Tris-glucose-20% egg yolk extender. For each tomcat, the diluted sperm was split into two equal volumes and cooled to 5 degrees C at a rate of 0.5 degrees C/min; one sample for 60 min (control) and the other for 24 h (cooled). After the cooling period, samples from both groups were frozen using an identical freezing protocol. Sperm samples were evaluated in three different periods: immediately after harvesting, after cooling at 5 degrees C for 24 h (cooled group) and after freezing thawing of control and cooled groups. Evaluations consisted of sperm motility and progressive status, sperm morphology and plasma membrane integrity (PMI) using two fluorescent probes. After cooling for 24 h, a decrease (p < 0.05) in sperm motility, progressive status and PMI was observed when compared to sperm samples immediately after collection. Comparing the results obtained after thawing, no difference (p < 0.05) was found regarding sperm motility, progressive status, PMI and sperm morphology between control and cooled groups. The results from the present study show that cooling cat epididymal spermatozoa at 5 degrees C for 24 h prior to freezing does not lead to major damage of spermatozoa impairing the freeze-thaw process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The austenite decomposition in C-Mn steel containing boron was studied by continuous cooling from 1100 and 845 degreesC using the Jominy test. The results indicate that the different cooling speeds and the presence of boron refine and change the percentage of ferrite microstructure, martensite, and fine pearlite. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram estudados os efeitos da temperatura cutânea (Ts) sobre a taxa de termólise por evaporação cutânea (Es) de vacas Holandesas cronicamente expostas ao sol, considerando a pigmentação do pelame. Dezesseis vacas puras de origem foram medidas quanto à evaporação e à temperatura cutâneas às 13 h, após 6 horas de exposição ao sol, no mesmo local (flanco, pescoço e glúteo) e considerando separadamente as malhas negras e as brancas. A evaporação cutânea foi medida por meio de cápsula ventilada. Nas áreas negras a taxa de sudação (138,9 ± 8,5 g.m-2.h-1), a taxa de termólise por evaporação cutânea (93,3 ± 5,7 W.m-2) e a temperatura da superfície cutânea (33,1 ± 0,2°C) foram maiores que nas áreas brancas (109,5 ± 9,7 g.m-2.h-1, 73,6 ± 6,5 W.m-2 e 32,6 ± 0,2°C, respectivamente). Há uma relação exponencial entre evaporação e temperatura cutâneas, que pode ser representada pela equação Es = 31,5+3,67 exp{(Ts-27,9)/2,19115}, com coeficiente de determinação r²=0,68. A taxa de termólise por evaporação cutânea permanece quase constante (cerca de 48 W.m-2) até que a temperatura cutânea atinge aproximadamente 31°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Well-fitted dentures prevent hyperplasic lesions, provide chewing efficiency and promote patient's comfort. Several factors may affect final adaptation of dentures, as the type of the acrylic resin, the flask cooling procedure and the water uptake. This investigation evaluated the effect of water storage and two different cooling procedures [bench cooling (BC) for 2 h; running water (RW) at 20 degreesC for 45 min] on the final adaptation of denture bases. A heat-cured acrylic resin (CL, Classico, Classico Artigos Odontologicos) and two microwave-cured acrylic resins [Acron MC, (AC) GC Dent. Ind. Corp.; Onda Cryl (OC), Classico Artigos Odontologicos] were used to make the bases. Adaptation was assessed by measuring the weight of an intervening layer of silicone impression material between the base and the master die. Data was submitted to ANOVA and Tukey's test (0.05). The following means were found: (BC) CL=0.72 +/- 0.03 a; AC=0.70 +/- 0.03 b; OC=0.76 +/- 0.04 c//(RW) CL= 1.00 +/- 0.11 a; AC=1.00 +/- 0.12 a; OC=0.95 +/- 0.10 a. Different labels join groups that are not statistically different (P > 0.05). Comparisons are made among groups submitted to the same cooling procedure (BC or RW). The conclusions are: interaction of type of material and cooling procedure had a statistically significant effect on the final adaptation of the denture bases (P < 0.05); water storage was not detected as a source of variance (P > 0.05) on the final adaptation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laser Welding process was introduced into dentistry by the end of the 1980s, resulting on a great impulse to that area with the development of cheaper and smaller equipment, using simpler technique. This allowed greater use of that process on the confection of prostheses compared to the brazing process since the heat source for that process is a concentrated light beam of high power, which minimizes distortion problems on the prosthetic pieces. Ag-Pd-Au-Cu alloy used on the confection of dental implant prostheses was observed before and after subjection to the laser welding process. The microstructure was analyzed with the. use of optic microscopy and the corrosion resistance was studied by the traditional electrochemical techniques and by electrochemical impedance, under environmental conditions simulating the aggressiveness found in the mouth cavity. A structural change was detected on the weld area, which presented a refined microstructure deriving from the high-speed cooling. The base metal out of the weld area presented a fusion coarse microstructure. The electrochemical essays showed differences on the potentiodynamic polarization behavior in both weld and metal base areas, indicating superior corrosion resistance in the weld area. The impedance spectra were characterized by capacitive distorted components, presenting linear impedance in the low frequencies area. (C) 2002 Elsevier B.V. B.V. All rights reserved.