964 resultados para affinity capillary electrophoresis
Resumo:
The proposed method for the identification of adulteration was based on the controlled acid hydrolysis of xylan and starch present in some vegetable adulterants, followed by the analysis of the resulting xylose and glucose, which are the monosaccharides that compose, respectively, the two polysaccharides. The acid hydrolysis with HCl increases the ionic strength of the sample, which impairs the electrophoretic separation. Thus, a neutralization step based on anion exchange resin was necessary. The best separations were obtained in NaOH 80 mmol/L, CTAB 0.5 mmol/L, and methanol 30% v/v. Because of the high value of pH, monosaccharides are separated as anionic species in such running electrolyte. The LOQ for both monosaccharides was 0.2 g for 100 g of dry matter, which conforms to the tolerable limits.
Resumo:
Serum protein electrophoresis is used as a screening test for monoclonal gammopathies. Here, we present a case of a high-concentration monoclonal immunoglobulin (M-protein) that was missed by serum protein electrophoresis on a Capillarys 2 capillary zone electrophoresis system. The aim of our study was to identify the reason for the failure of the system to detect the M-protein.
Resumo:
Capillary zone electrophoresis (CZE) with a dynamic double coating based on the new CEofix reagents is shown to provide high-resolution separations of serum transferrin (Tf) isoforms, a prerequisite for the monitoring of unusual and complex Tf patterns, including those seen with genetic variants and disorders of glycosylation. A 50 microm I.D. fused-silica capillary of 60 cm total length, an applied voltage of 20 kV and a capillary temperature of 30 degrees C results in 15 min CZE runs of high assay precision and thus provides a robust approach for the determination of carbohydrate-deficient transferrin (CDT, sum of asialo-Tf and disialo-Tf in relation to total Tf) in human serum. Except for selected samples of patients with severe liver diseases and sera with high levels of paraproteins, interference-free Tf patterns are detected. Compared with the use of the previous CEofix reagents for CDT under the same instrumental conditions, the resolution between disialo-Tf and trisialo-Tf is significantly higher (1.7 versus 1.4). The CDT levels of reference and patient sera are comparable, suggesting that the new assay can be applied for screening and confirmation analyses. The high-resolution CZE assay represents an attractive alternative to HPLC and can be regarded as a candidate of a reference method for CDT.
Resumo:
The use of capillary zone electrophoresis (CZE) with indirect absorbance detection for the analysis of ethyl sulfate (EtS) in serum and urine was investigated. EtS is a direct metabolite of ethanol employed as marker for recent alcohol consumption. Fused-silica capillaries of 60 cm total length were either coated with cetyltrimethylammonium bromide (CTAB, 50 microm I.D. capillary) or poly(diallyldimethylammonium chloride) (PDADMAC, 100 microm I.D. capillary) to allow CZE analyses to be performed with reversed polarity. At pH 2.2 with a maleic acid/phthalic acid background electrolyte, both approaches provided reliable EtS serum levels down to 0.2 mg L(-1) (1.6 microM) for the analysis of solid-phase extracts that were prepared after chloride precipitation. Analysis of urines diluted to a conductivity of 5 S m(-1) and analyzed in the two capillary formats resulted in limits of quantification (LOQs) of 2 and 1 mg L(-1), respectively. With urines adjusted to 10 S m(-1) via dilution or condensation, an LOQ of 0.6 mg L(-1) (4.8 microM) was obtained in the CTAB coated capillary whereas in the PDADMAC-coated capillary of equal length not all matrix components were resolved from EtS. The developed assays are robust and suitable to monitor EtS in samples of individuals who consumed as little as one standard drink of an alcoholic beverage containing about 14 g of ethanol.
Resumo:
Data obtained with two CZE assays for determining carbohydrate-deficient transferrin (CDT) in human serum under routine conditions, the CAPILLARYS CDT and the high-resolution CEofix (HR-CEofix) CDT methods, are in agreement with patient sera that do not exhibit interferences, high trisialo-transferrin (Tf) levels or genetic variants. HR-CEofix CDT levels are somewhat higher compared to those obtained with the CAPILLARYS method and this bias corresponds to the difference of the upper reference values of the two assays. The lower resolution between disialo-Tf and trisialo-Tf observed in the CAPILLARYS system (mean: 1.24) compared to HR-CEofix (mean: 1.74) is believed to be the key for this difference. For critical sera with high trisialo-Tf levels, genetic variants, or certain interferences in the beta-region, the HR-CEofix approach is demonstrated to perform better than CAPILLARYS. However, the determination of CDT with the HR-CEofix method can also be hampered with interferences. Results with disialo-Tf values larger than 3% in the absence of asialo-Tf should be evaluated with immunosubtraction of Tf and possibly also confirmed with another CZE method or by HPLC. Furthermore, data gathered with the N Latex CDT direct immunonephelometric assay suggest that this assay can be used for screening purposes. To reduce the number of false negative results, CDT data above 2.0% should be confirmed using a separation method.
Resumo:
Ethyl glucuronide (EtG) is a marker of recent alcohol consumption. For the optimization of the analysis of EtG by CZE with indirect absorbance detection, the use of capillaries with permanent and dynamic wall coatings, the composition of the BGE, and various sample preparation procedures, including dilution with water, ultrafiltration, protein precipitation, and SPE, were investigated. Two validated screening assays for the determination of EtG in human serum, a CZE-based approach and an enzyme immunoassay (EIA), are described. The CZE assay uses a coated capillary, 2,4-dimethylglutaric acid as an internal standard, and a pH 4.65 BGE comprising 9 mM nicotinic acid, epsilon-aminocaproic acid and 10% v/v ACN. Proteins are removed via precipitation with ACN prior to analysis and the LOQ is 0.50 mg/L. The EIA is based upon commercial reagents which are promoted for the determination of urinary EtG. Krebs-Ringer solution containing 5% BSA is used as a calibration matrix. All samples are ultrafiltered prior to analysis of the ultrafiltrate on a Mira Plus analyzer. Assay calibration ranged between 0 and 2 mg/L and the upper reference limit was determined to be 0.05 mg/L. Both assays proved to be suitable for the analysis of samples from different individuals. For EtG levels above 0.50 mg/L, good agreement was observed for the comparison of the results of the two methods.
Resumo:
The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period.
Resumo:
High-resolution capillary zone electrophoresis in the routine arena with stringent quality assurance is employed for the determination of carbohydrate-deficient transferrin in human serum. The assay comprises mixing of human serum with a Fe(III) -containing solution prior to analysis of the iron-saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. In contrast to other assays, it provides sufficient resolution for proper recognition of genetic transferrin variants. Analysis of 7290 patient sera revealed 166 isoform patterns that could be assigned to genetic variants, namely, 109 BC, 53 CD, one BD and three CC variants. Several subtypes of transferrin D can be distinguished as they have large enough differences in pI values. Subtypes of transferrin C and B cannot be resolved. However, analysis of the detection time ratios of tetrasialo isoforms of transferrin BC and transferrin CD variants revealed multimodal frequency histograms, indicating the presence of subtypes of transferrin C, B and D. The data gathered over 11 years demonstrate the robustness of the high-resolution capillary zone electrophoresis assay. This is the first account of a capillary zone electrophoresis based carbohydrate-deficient transferrin assay with a broad overview on transferrin isoform patterns associated with genetic transferrin variants.
Resumo:
CZE-based assays for carbohydrate-deficient transferrin (CDT) in which serum is mixed with an Fe(III) ion-containing solution prior to analysis are effective approaches for the determination of CDT in patient samples. Sera of patients with progressed diseases, however, are prone to interferences comigrating with transferrin (Tf) that prevent the proper determination of CDT by CZE in these samples. The need of a simple and economic approach to immunoextract Tf from human serum prompted us to investigate the use of a laboratory-made anti-Tf spin column containing polyclonal rabbit anti-human Tf antibodies linked to Sepharose 4 Fast Flow beads. This article reports extraction column manufacturing and column characterization with sera having normal and elevated CDT levels. The developed procedure was applied to a number of relevant hepatology and dialysis patient samples and could thereby be shown to represent an effective method for extraction and concentration of all Tf isoforms. Furthermore, lipemic sera were delipidated using a mixture of diisopropyl ether and butanol prior to immunoextraction. CDT could unambiguously be determined in all pretreated samples.
Resumo:
The feasibility of employing classical electrophoresis theory to determine the net charge (valence) of proteins by capillary zone electrophoresis is illustrated in this paper. An outline of a procedure to facilitate the interpretation of mobility measurements is demonstrated by its application to a published mobility measurement for Staphylococcal nuclease at pH 8.9 that had been obtained by capillary zone electrophoresis. The significantly higher valence of +7.5 (cf. 5.6 from the same series of measurements) that has been reported on the basis of a charge ladder approach for charge determination signifies the likelihood that the latter generic approach may be prone to error arising from nonconformity of the experimental system with an inherent assumption that chemical modification or mutation of amino acid residues has no effect on the overall three-dimensional size and shape of the protein. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
This article describes an effective microchip protocol based on electrophoretic-separation and electrochemical detection for highly sensitive and rapid measurements of nitrate ester explosives, including ethylene glycol dinitrate (EGDN), pentaerythritol tetranitrate (PETN), propylene glycol dinitrate (PGDN) and glyceryl trinitrate (nitroglycerin, NG). Factors influencing the separation and detection processes were examined and optimized. Under the optimal separation conditions obtained using a 15 mM borate buffer (pH 9.2) containing 20 mM SDS, and applying a separation voltage of 1500 V, the four nitrate ester explosives were separated within less than 3 min. The glassy-carbon amperometric detector (operated at -0.9 V vs. Ag/AgCl) offers convenient cathodic detection down to the picogram level, with detection limits of 0.5 ppm and 0.3 ppm for PGDN and for NG, respectively, along with good repeatability (RSD of 1.8-2.3%; n = 6) and linearity (over the 10-60 ppm range). Such effective microchip operation offers great promise for field screening of nitrate ester explosives and for supporting various counter-terrorism surveillance activities.
Resumo:
The dimorphic fungus Paracoccidioides brasiliensis is the causative agent of paracoccidioidomycosis, the most frequent systemic mycosis in Latin America. Our group has been working with paracoccin, a P. brasiliensis lectin with MM 70 kDa. which is purified by affinity, with immobilized N-acetylglucosamine (GlcNAc). Paracoccin has been described to play a role in fungal adhesion to extracellular matrix components and to induce high and persistent levels or TNF alpha. and nitric oxide production by macrophages. In the cell wall, paracoccin colocalizes with the beta-1,4-homopolymer of GlcNAc into the budding sites of the P. brasiliensis yeast cell. In this paper we present a protocol for the chitin-affinity purification or paracoccin. This procedure provided higher yields than those achieved by means of the technique based oil the affinity of this lectin with GlcNAc and had an impact on downstream assays. SDS-PAGE and Western blot analysis revealed similarities between the N-acetylglucosamine- and chitin-bound fractions, confirmed by MALDI-TOF-MS of trypsinic peptides. Western blot of two-dimensional gel electrophoresis of the yeast extract showed a major spot with M(r) 70000 and pl approximately 5.63. Moreover, an N-acetyl-beta-D-glucosaminidase activity was reported for paracoccin, thereby providing new insights into the mechanisms that lead to cell wall remodelling and opening new perspectives for its structural characterization. Copyright (C) 2009 John Wiley & Sons. Ltd.
Resumo:
Purification of recombinant human growth hormone (rhGH) from Chinese hamster ovary (CHO) cell culture supernatant by Gradiflow large-scale electrophoresis is described. Production of rhGH in CHO cells is an alternative to production in Escherichia coli, with the advantage that rhGH is secreted into protein-free production media, facilitating a more simple purification and avoiding resolubilization of inclusion bodies and protein refolding. As an alternative to conventional chromatography, rhGH was purified in a one-step procedure using Gradiflow technology. Clarified culture supernatant containing rhGH was passed through a Gradiflow BF200 and separations were performed over 60 min using three different buffers of varying pH. Using a 50 mM Tris/Hepes buffer at pH 7.5 together with a 50 kDa separation membrane, rhGH was purified to approximately 98% purity with a yield of 90%. This study demonstrates the ability of Gradiflow preparative electrophoresis technology to purify rhGH from mammalian cell culture supernatant in a one-step process with high purity and yield. As the Gradiflow is directly scalable, this study also illustrates the potential for the inclusion of the Gradiflow into bioprocesses for the production of clinical grade rhGH and other therapeutic proteins. (C) 2003 Elsevier Science (USA). All rights reserved.
Resumo:
Brown widow spider (Latrodectus geometricus) venom (BrWSV) produces few local lesions and intense systemic reactions such as cramps, harsh muscle pains, nausea, vomiting and hypertension. Approximately 16 protein bands under reducing conditions and ~ 14 bands under non-reducing conditions on a 12.5% sodium dodecyl sulfate-polyacrylamide gel electrophoresis were observed. Neurotoxic clinical manifestations were confirmed in vivo, while proteolytic activity was demonstrated on gelatine film. Severe ultrastructural damages in mice skeletal muscles were observed at 3, 6, 12 and 24 h postinjection with at total of 45 µg of venom protein. Infiltration of eosinophils and ruptures of the cellular membranes were observed in the muscles along with swelling of the nuclear cover and interruption of the collagen periodicity. Altered mitochondrias and autophage vacuoles, nuclear indentation and mitochondria without cristae, slight increment of intermyofibrillar and subsarcolemic spaces and myelinic figures formation were also observed. In the capillary, endothelial membrane unfolding into the lumen was noticed; along with myelinic figures compatible with a toxic myopathy. Swollen sarcotubular systems with lysis of membrane, intense mitochondria autophagia and areas without pinocytic vesicles were observed. Swollen mitochondria surrounded by necrotic areas, myofibrillar disorganization and big vacuolas of the sarcotubular system, degenerated mitochondrium with formation of myelinic figure was seen. Glycogenosomes with small particulate, muscle type glycogen was noticed. Autophagic vacuole (autophagolysosomes) and necrotic areas were also noticed. These damages may be due to interactive effects of the multifactorial action of venom components. However, Latrodectus geometricus venom molecules may also be utilized as neuro therapeutic tools, as they affect neuronal activities with high affinity and selectivity. To our knowledge, the present study is the first ultrastructural report in the literature of muscle injuries and neurological and proteolytic activities caused by BrWSV.
Resumo:
Fixation enhances cellular morphology and reduces loss of molecules during tissue processing. Antibodies against fixation-resistant epitopes are very useful, because they allow an immunocytochemical detection in tissue of better preserved morphology. However, fixatives can alter antigenicity and adversely affect the result of immunohistochemical procedures. To address this problem, this study examined the feasibility of generating antibodies to a paraformaldehyde-fixed antigen for use in immunohistochemical procedures. The large subunit of neurofilament proteins was selected for this study. Crude neurofilament proteins were isolated and separated by SDS-polyacrylamide gel electrophoresis. The large subunit of neurofilaments (NF-H) was electroeluted from the electrophoresis gel and exposed to paraformaldehyde, and used for immunization of a rabbit. The rabbit antiserum was affinity purified on CNBr-sepharose immobilized neurofilament proteins. On Western blots, the antibody reacted with the NF-H protein in a phosphorylation-dependent manner. In aldehyde-fixed cerebellum, the antibody strongly stained axons. In contrast, in alcohol-fixed cryostat sections the immunocytochemical detection was substantially reduced. The procedure presented in this study, involving a simple pretreatment of the immunogen, allows for the generation of an antibody that may be used in immunohistochemical studies where localization of the immunogen may be reduced or even lost by aldehyde fixation.