987 resultados para Valvular prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aspergillosis is an infection caused by saprophytic fungi of the genus Aspergillus, which typically occurs in immunosuppressed individuals, but has also been reported in immunocompetent patients. The main routes of entry are the respiratory tract, skin, cornea, and ear, and the infection may be localized or disseminated by contiguity or vascular invasion. We report a severe case of rhinosinusitis with cutaneous involvement, caused by invasive aspergillosis, in an immunocompetent user of inhaled cocaine. Invasive aspergillosis related to cocaine abuse has not yet been reported in the literature. After itraconazole treatment and surgical debridement, complete clinical remission was achieved. Nasal reconstruction with a skin graft over a silicone prosthesis resulted in a satisfactory esthetic outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Desenhado por Jacque Fresco, o Projecto Vénus é uma proposta de reconfiguração social, tendo como ferramenta de trabalho a cidade. A cidade projectada por Jacque Fresco responde de alguma forma a necessidade de encontrar programas de hibridização que ultrapassem os receios do determinismo em relação ao papel da tecnologia, e conferindo um cariz mais aproximado dos conceitos antropológicos de Leroi-Gourhan quando este apelida a técnica de utensílio colocado fora do corpo e que permitiu ao homem sobreviver num mundo hostil. A diferença é que a técnica já assumiu uma condição que transcende o mero instrumento, para ser já ela própria configuradora da realidade, como Kittler dizia em acerca dos media. Fresco coloca a cidade como paradigma de uma revolução cibernética, uma tecnotopia, em que a tecnologia servirá para libertar o humano de condições políticas, económicas e sociais que o autor considera obsoletas. Uma nova configuração multidimensional que se apoia numa nova esfera pública, ambicionando um ethos global com uma estrutura digital para comunicações em rede. Fresco atribui uma dimensão de extrema importância aos factos de a tecnologia, no Projecto Vénus, ficar paredes meias com a natureza sem que tenha uma relação intrusiva, mas antes uma relação de responsabilidade pela gestão eficaz dos sistemas circundantes que preconizam muitas das “expectativas messiânicas” de que Walter Benjamin nos falava acerca da tecnologia. O objectivo da presente dissertação será a partir da definição de técnica e da tecnologia e, mais tarde discutindo esta cidade cibernética chamada Projecto Vénus, tentar responder às seguintes perguntas: como Gourhan nos diz, a técnica foi colocada fora do corpo para permitir aos seres humanos sobreviver, podemos supor que, neste momento, com a emergência de novas áreas, como a biotecnologia, nanotecnologia e robótica, a tecnologia retorna ao corpo humano para resolver a falha que, de acordo com o mito de Epimeteu, lhe deu origem? Se assim for, este processo de incorporação dos aparelhos protéticos, pode significar que estamos a entrar na era de reprodutibilidade do corpo humano como um objecto? Além disso, será a crescente visibilidade do Projecto Vénus um sintoma de uma crescente sociedade tecnológica, uma tecnotopia cujo fim último é a reconfiguração da máquina antropológica tal como Agamben colocou em «The Open»?

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rheumatic fever is still the most commonly seen rheumatic disease in Brazilian pediatric rheumatology clinics. It remains a significant health problem since subsequent cardiac sequelae represent one of the most important causes of chronic heart disease in children. We reviewed the clinical manifestations of rheumatic fever in 786 patients, followed at seven pediatric rheumatology clinics in the state of São Paulo, Brazil. All patients were diagnosed according to revised Jones' criteria. Regarding major criteria, 396 (50.4%) children exhibited carditis, 453 (57.6%) polyarthritis, 274 (34.8%) chorea, 13 (1.6%) erythema marginatum, and 12 (1.5%) subcutaneous nodules. Valvular lesions documented by echocardiography in the absence of accompanying auscultatory findings were found in 144 (18.3%) patients. Migratory polyarthritis was observed in 290 (64.0%) patients with articular involvement. Documented previous streptococcal infection assessed by serum antistreptolysin (ASO) titers occurred in 531 (67.5%) patients. Even though prophylaxis with benzathine penicillin was recommended to all patients, recurrent attacks were observed in 147 (18.7%). We emphasize the high frequency of chorea, silent carditis and recurrences in our series as well as the variable clinical presentation of arthritis in rheumatic fever. Multicenter studies should be encouraged to improve our understanding of the clinical features of rheumatic diseases in children and adolescents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We sought to describe the bone bridge technique in adults, and present a variation for use in children, as well as to present its applicability as an option in elective transtibial amputations. This paper presents a prospective study of 15 transtibial amputations performed between 1992 and 1995 in which the bone bridge technique was employed. The patients' ages ranged from 8 to 48 years, with an average of 22.5 years. This technique consisted of the preparation of a cylinder of periosteum extracted from the tibia and with cortical bone fragments attached to it to promote a tibiofibular synostosis on the distal extremity of the amputation stump. We noted that the cortical bone fragments were dispensable when the technique was employed in children, due to the increased osteogenic capacity of the periosteum. This led to a variation of the original technique, a bone bridge without the use of the cortical bone fragments. RESULTS: The average time spent with this procedure, without any significant variation between adults and children, was 171 minutes. The adaptation to the definitive prosthesis was accomplished between 20 and 576 days, with an average of 180 days. Revision of the procedure was necessary in 3 amputations. CONCLUSIONS: This technique may be employed in transtibial amputations in which the final length of the stump lies next to the musculotendinous transition of the gastrocnemius muscle, as well as in the revision of amputation stumps in children, where the procedure has been shown to be effective in the prevention of lesions due to excessive bone growth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - Introdução: Os critérios de adequação (Appropriate Use Criteria - AUC) em Ecocardiografia Transtorácica (ETT) foram publicados com o intuito de permitir o uso racional da ecocardiografia, de influenciar decisões clinicas, prestar cuidados de saúde de elevada qualidade e melhorar o outcome dos pacientes. A relação entre a adequação destes e o seu impacto clinico ainda não se encontra largamente estudada. Objectivo: Neste estudo pretendeu-se avaliar o grau de adesão aos AUC em ETT, em diferentes contextos de atendimento e de acordo com diferentes especialidades, bem como o impacto clínico do exame no outcome do paciente, num hospital público terciário no Reino Unido. Metodologia: 859 ETTs realizados consecutivamente no mês de Janeiro de 2014, foram revistos por forma a avaliar a sua adequação e foram classificados como adequados, incertos ou inadequados de acordo com as guidelines de 2011. De seguida os registos dos pacientes foram revistos com o intuito de avaliar o impacto clinico dos ETTs e foram classificados de acordo com uma das 3 seguintes categorias: (1) alteração ativa dos cuidados – por continuação ou descontinuação dos cuidados como resultado do ETT, (2) continuação dos cuidados – sem continuação ou descontinuação dos cuidados, mas comunicação ao paciente dos resultados do ETT, (3) sem alteração dos cuidados – os cuidados ao paciente já estavam a ser aplicados previamente ao resultado do ETT, causa de sintomas já estabelecida no momento da requisição para exame, exame prévio explicativo dos sintomas e sem indicação aguda para novo ETT, terapêutica não alterada ou inexistência de documentação relativa aos achados ecocardiográficos. Pacientes cujos registos não se encontravam disponíveis foram excluídos (259). Todas as classificações foram avaliadas por uma cardiologista independente, sem relação direta com o estudo. Resultados: A nossa amostra apresentou uma média de idades de 63 ± 17 anos, com uma equilíbrio de géneros. A maioria dos exames foi solicitada em contexto de ambulatório (81,4%), pela Cardiologia (50,3%) e pela Medicina Geral e Familiar (13,4%). Relativamente aos achados ecocardiográficos dos exames, 7,6% demonstraram disfunção sistólica do ventrículo esquerdo moderada a grave, 4,0% revelaram doença valvular grave e 5,1% hipertensão pulmonar significativa. Em relação à adequação dos pedidos para ETTs, 76,5% foram adequados, 7,1% inadequados e 12,6% incertos. Relativamente ao impacto clínico dos ETTs, 42,7% dos exames revelaram uma alteração ativa nos cuidados, 15,6% mostraram uma continuação dos cuidados e 11,5% demonstraram não haver alteração nos cuidados. A idade (P=0,05), o contexto de atendimento (P<0,01) e o pedido realizado pela especialidade medicina geral e familiar (MGF) (P=0,02) foram os preditores mais importantes de uma alteração ativa nos cuidados. Numa perspectiva de prestação de cuidados a uma população mais idosa, o contexto de atendimento, a presença de achados ecocardiográficos significativos e a não alteração dos cuidados apresentam uma relação significativa com a idade. Conclusões: Os dados demonstram que quase 8 em cada 10 ETTs foram considerados adequados e que 4 em cada 10 exames não apresentaram alteração ativa dos cuidados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study is to evaluate the benefits of drainage in the Stoppa procedure for inguinal repair. PATIENTS AND METHODS: The use of a suction drain was randomized at the end of the surgical intervention in 26 male patients undergoing inguinal hernia repair, divided into 2 groups: Group A, 12 patients undergoing drainage, and group B, 14 patients not undergoing drainage. On the second postoperative day, all patients underwent abdominal pelvic computed tomography scan examination to detect the presence of abdominal fluid collection. RESULTS: In group A, no patient developed fluid collection in the preperitoneal space, and 1 patient presented with an abscess in the preperitoneal space on the 15th postoperative day. In group B, 12 patients presented with fluid collections in the preperitoneal space on computed tomography scan evaluation. However, only 3 patients presented minor complications. None of the patients developed a major complication. CONCLUSION: The use of suction drainage with the Stoppa procedure does not provide any benefit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electroactive polymers are one of the most interesting class of polymers used as smart materials in various applications, such as the development of sensors and actuators for biomedical applications in areas such as smart prosthesis, implantable biosensors and biomechanical signal monitoring, among others. For acquiring or applying the electrical signal from/to the piezoelectric material, suitable electrodes can be produced from Ti based coatings with tailored multifunctional properties, conductivity and antibacterial characteristics, through Ag inclusions. This work reports on Ag-TiNx electrodes, deposited by d. c. and pulsed magnetron sputtering at room temperature on poly(vinylidene fluoride), PVDF, the all-round best piezoelectric polymer.. Composition of the electrodes was assessed by microanalysis X-ray system (EDS - energy dispersive spectrometer). The XRD results revealed that the deposition conditions preserve the polymer structure and suggested the presence of crystalline fcc-TiN phase and fcc-Ag phase in samples with N2 flow above 3 sccm. According to the results obtained from SEM analysis, the coatings are homogeneous and Ag clusters were found for samples with nitrogen flow above 3 sccm. With increasing nitrogen flow, the sheet resistivity tend to be lower than the samples without nitrogen, leading also to a decrease of the piezoelectric response. It is concluded that the deposition conditions do significantly affect the piezoelectric polymer, which maintain its characteristics for sensor/actuator applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This research work intends to clarify the role of artificial saliva, in particularly the role of mucin, a salivary protein, on the surface properties and adhesion ability of Candida spp. oral clinical isolates to abiotic surfaces. Methods: Four oral clinical isolates of Candida spp. were used: two Candida albicans strains (AC; AM) and two Candida parapsilosis strains (AD; AM2). The strains were isolated from patients using oral prosthesis. The microorganisms were cultured in the absence or presence of mucin and artificial saliva, and their adhesion to an abiotic surface (coated with mucin and artificial saliva) was evaluated. Results: The presence of mucin per se onto the abiotic surface decreased the adhesion of all strains, although the combination of mucin with artificial saliva had reduced this effect. No direct correlation between adhesion and the surface free energies of adhesion of the microorganisms was found. Significance: Candida spp. were human commensal microorganisms that became pathogenic when the host immune defenses were compromised. Medical devices were colonized by Candida spp. particularly, oral prostheses, which might lead to the degradation of the prostheses and systemic infections. The salivary secretions that constantly cover the oral cavity influenced Candida spp. adhesion process. Therefore, it was important to understand the interactions between Candida spp., salivary proteins and the characteristic of oral prosthesis when developing materials for oral prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last few years, many reports have been describing promising biocompatible and biodegradable materials that can mimic in a certain extent the multidimensional hierarchical structure of bone, while are also capable of releasing bioactive agents or drugs in a controlled manner. Despite these great advances, new developments in the design and fabrication technologies are required to address the need to engineer suitable biomimetic materials in order tune cells functions, i.e. enhance cell-biomaterial interactions, and promote cell adhesion, proliferation, and differentiation ability. Scaffolds, hydrogels, fibres and composite materials are the most commonly used as biomimetics for bone tissue engineering. Dynamic systems such as bioreactors have also been attracting great deal of attention as it allows developing a wide range of novel in vitro strategies for the homogeneous coating of scaffolds and prosthesis with ceramics, and production of biomimetic constructs, prior its implantation in the body. Herein, it is overviewed the biomimetic strategies for bone tissue engineering, recent developments and future trends. Conventional and more recent processing methodologies are also described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa Doutoral em Engenharia de Materiais)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS: Seventeen patients with a mean age of 51.7±12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG) - Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS: The mean heart rate during Holter monitoring was 82±8bpm; the maximal heart rate was 126 ± 23bpm and the minimal heart rate 57±7bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3±5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8±0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION: After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE - To analyze the immediate and late results of mitral valve repair with quadrangular resection of the posterior leaflet without the use of a prosthetic ring annuloplasty. METHODS - Using this technique, 118 patients with mitral valve prolapse who underwent mitral repair from January '84 through December '96 were studied. Age ranged from 30 to 86 (mean = 59.1±11.8) years and 62.7% were males. An associated surgery was performed in 22% of the patients, and coronary artery bypass graft was the most frequently performed surgery (15 patients - 12.7%). In 20 (16.9%) patients other associated techniques of mitral valve repair were used and shortening of elongated chordae tendineae was the most frequent one (6 patients). RESULTS - Immediate mortality was 0.9% (one patient). Long-term rates for thromboembolism, endocarditis, re-operation and death in the late postoperative period were 0.4%, 0.4%, 1.7% and 2.2% patients/year, respectively. The actuarial curve of survival was 83.8±8.6% over 12 years; survival free from re-operation was 91.8±4.3%, free from endocarditis was 99.2±0.8% and free from thromboembolism was 99.2±0.8%. In the late postoperative period, 93.8% of the patients were in functional class 1 (NYHA), with a complete follow-up in 89.7% of the patients. CONCLUSION - Patients with mitral valve prolapse who undergo mitral valve repair using this technique have a satisfactory prognosis over 12 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of chronic nonspecific constrictive pericarditis with myocardial involvement in a 19-month-old infant. The patient underwent total pericardiectomy and had irreversible hemodynamic instability. Constrictive pericarditis is rare in childhood. It may follow several processes, most frequently an infectious disease. The natural course of the disease consists of progressive myocardial dysfunction with atrioventricular valvular involvement. When diagnosis is established early in the course of the disease and treatment started immediately, the evolution is favorable in most instances.