926 resultados para Téléphone portable
Resumo:
Background In the emergency department, portable point-of-care testing (POCT) coagulation devices may facilitate stroke patient care by providing rapid International Normalized Ratio (INR) measurement. The objective of this study was to evaluate the reliability, validity, and impact on clinical decision-making of a POCT device for INR testing in the setting of acute ischemic stroke (AIS). Methods A total of 150 patients (50 healthy volunteers, 51 anticoagulated patients, 49 AIS patients) were assessed in a tertiary care facility. The INR's were measured using the Roche Coaguchek S and the standard laboratory technique. Results The interclass correlation coefficient and 95% confidence interval between overall POCT device and standard laboratory value INRs was high (0.932 (0.69 - 0.78). In the AIS group alone, the correlation coefficient and 95% CI was also high 0.937 (0.59 - 0.74) and diagnostic accuracy of the POCT device was 94%. Conclusions When used by a trained health professional in the emergency department to assess INR in acute ischemic stroke patients, the CoaguChek S is reliable and provides rapid results. However, as concordance with laboratory INR values decreases with higher INR values, it is recommended that with CoaguChek S INRs in the > 1.5 range, a standard laboratory measurement be used to confirm the results.
Resumo:
This is the first volume in a book series examining how organizations in the creative industries (see preface for extensive discussion of creative industries) respond to disruptive change and how they themselves generate business innovations. The papers included in the volume examine the processes of disruption and transformation due to the technology of the Internet, social forces driven by social media, the development of new portable digital devices with greater capabilities and smaller size, the decreasing costs of new information, and the creation of new business models and forms of intellectual property ownership rights for a digitized industry...
Resumo:
This paper investigates the effects of experience on the intuitiveness of physical and visual interactions performed by airport security screeners. Using portable eye tracking glasses, 40 security screeners were observed in the field as they performed search, examination and interface interactions during airport security x-ray screening. Data from semi structured interviews was used to further explore the nature of visual and physical interactions. Results show there are positive relationships between experience and the intuitiveness of visual and physical interactions performed by security screeners. As experience is gained, security screeners are found to perform search, examination and interface interactions more intuitively. In addition to experience, results suggest that intuitiveness is affected by the nature and modality of activities performed. This inference was made based on the dominant processing styles associated with search and examination activities. The paper concludes by discussing the implications that this research has for the design of visual and physical interfaces. We recommend designing interfaces that build on users’ already established intuitive processes, and that reduce the cognitive load incurred during transitions between visual and physical interactions.
Resumo:
The purpose of this study is to examine the changes of energy cost during a high-heeled continuous jogging.Thirteen healthy female volunteers jointed in this study with heel height of the shoes varied from 1, 4.5 and 7 cm, respectively. Each subjects jogged on the treadmill with K4b2 portable gas analysis system. The results of this study showed that ventilnation, relative oxygen consumption and energy expenditure increased with the increase of heel height and these values shows significantly larger when the heel height reached to 7 cm. Present study suggest that wearing high heel shoes jogging could directly increase energy consumption, causing neuromuscular fatigue.
Resumo:
Tridiagonal diagonally dominant linear systems arise in many scientific and engineering applications. The standard Thomas algorithm for solving such systems is inherently serial forming a bottleneck in computation. Algorithms such as cyclic reduction and SPIKE reduce a single large tridiagonal system into multiple small independent systems which can be solved in parallel. We have developed portable cyclic reduction and SPIKE algorithm OpenCL implementations with the intent to target a range of co-processors in a heterogeneous computing environment including Field Programmable Gate Arrays (FPGAs), Graphics Processing Units (GPUs) and other multi-core processors. In this paper, we evaluate these designs in the context of solver performance, resource efficiency and numerical accuracy.
Resumo:
To strive to improve the rehabilitation program of individuals with transfemoral amputation fitted with bone-anchored prosthesis based on data from direct measurements of the load applied on the residuum we first of all need to understand the load applied on the fixation. Therefore the load applied on the residuum was first directly measured during standardized activities of daily living such as straight line level walking, ascending and descending stairs and a ramp and walking around a circle. From measuring the load in standardized activities of daily living the load was also measured during different phases of the rehabilitation program such as during walking with walking aids and during load bearing exercises.[1-15] The rehabilitation program for individuals with a transfemoral amputation fitted with an OPRA implant relies on a combination of dynamic and static load bearing exercises.[16-20] This presentation will focus on the study of a set of experimental static load bearing exercises. [1] A group of eleven individuals with unilateral transfemoral amputation fitted with an OPRA implant participated in this study. The load on the implant during the static load bearing exercises was measured using a portable system including a commercial transducer embedded in a short pylon, a laptop and a customized software package. This apparatus was previously shown effective in a proof-of-concept study published by Prof. Frossard. [1-9] The analysis of the static load bearing exercises included an analysis of the reliability as well as the loading compliance. The analysis of the loading reliability showed a high reliability between the loading sessions indicating a correct repetition of the LBE by the participants. [1, 5] The analysis of the loading compliance showed a significant lack of axial compliance leading to a systematic underloading of the long axis of the implant during the proposed experimental static LBE.
Resumo:
Background The purpose of this presentation is to outline the relevance of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees. The objectives are • To highlight the need for categorisation of activities of daily living • To present a categorization of load regime applied on residuum, • To present some descriptors of the four types of activity that could be detected, • To provide an example the results for a case. Methods The load applied on the osseointegrated fixation of one transfemoral amputee was recorded using a portable kinetic system for 5 hours. The load applied on the residuum was divided in four types of activities corresponding to inactivity, stationary loading, localized locomotion and directional locomotion as detailed in previously publications. Results The periods of directional locomotion, localized locomotion, and stationary loading occurred 44%, 34%, and 22% of recording time and each accounted for 51%, 38%, and 12% of the duration of the periods of activity, respectively. The absolute maximum force during directional locomotion, localized locomotion, and stationary loading was 19%, 15%, and 8% of the body weight on the anteroposterior axis, 20%, 19%, and 12% on the mediolateral axis, and 121%, 106%, and 99% on the long axis. A total of 2,783 gait cycles were recorded. Discussion Approximately 10% more gait cycles and 50% more of the total impulse than conventional analyses were identified. The proposed categorization and apparatus have the potential to complement conventional instruments, particularly for difficult cases.
Resumo:
Khaya senegalensis, African mahogany, a high-value hardwood, was introduced in the Northern Territory (NT) in the 1950s; included in various trials there and at Weipa, Q in the 1960s-1970s; planted on ex mine sites at Weipa (160 ha) until 1985; revived in farm plantings in Queensland and in trials in the NT in the 1990s; adopted for large-scale, annual planting in the Douglas-Daly region, NT from 2006 and is to have the planted area in the NT extended to at least 20,000 ha. The recent serious interest from plantation growers, including Forest Enterprises Australia Ltd (FEA), has seen the establishment of some large scale commercial plantations. FEA initiated the current study to process relatively young plantation stands from both Northern Territory and Queensland plantations to investigate the sawn wood and veneer recovery and quality from trees ranging from 14 years (NT – 36 trees) to 18-20 years (North Queensland – 31 trees). Field measures of tree size and straightness were complemented with log end splitting assessment and cross-sectional disc sample collection for laboratory wood properties measurements including colour and shrinkage. End-splitting scores assessed on sawn logs were relatively low compared to fast grown plantation eucalypts and did not impact processing negatively. Heartwood proportion in individual trees ranged from 50% up to 92 % of butt cross-sectional disc area for the visually-assessed dark coloured central heartwood and lighter coloured transition wood combined. Dark central heartwood proportion was positively related to tree size (R2 = 0.57). Chemical tests failed to assist in determining heartwood – sapwood boundary. Mean basic density of whole disc samples was 658 kg/m3 and ranged among trees from 603 to 712 kg/m3. When freshly sawn, the heartwood of African mahogany was orange-red to red. Transition wood appeared to be pinkish and the sapwood was a pale yellow colour. Once air dried the heartwood colour generally darkens to pinkish-brown or orange-brown and the effect of prolonged time and sun exposure is to darken and change the heartwood to a red-brown colour. A portable colour measurement spectrophotometer was used to objectively assess colour variation in CIE L*, a* and b* values over time with drying and exposure to sunlight. Capacity to predict standard colour values accurately after varying periods of direct sunlight exposure using results obtained on initial air-dried surfaces decreased with increasing time to sun exposure. The predictions are more accurate for L* values which represent brightness than for variation in the a* values (red spectrum). Selection of superior breeding trees for colour is likely to be based on dried samples exposed to sunlight to reliably highlight wood colour differences. A generally low ratio between tangential and radial shrinkages was found, which was reflected in a low incidence of board distortion (particularly cupping) during drying. A preliminary experiment was carried out to investigate the quality of NIR models to predict shrinkage and density. NIR spectra correlated reasonably well with radial shrinkage and air dried density. When calibration models were applied to their validation sets, radial shrinkage was predicted to an accuracy of 76% with Standard Error of Prediction of 0.21%. There was also a strong predictive power for wood density. These are encouraging results suggesting that NIR spectroscopy has good potential to be used as a non-destructive method to predict shrinkage and wood density using 12mm diameter increment core samples. Average green off saw recovery was 49.5% (range 40 to 69%) for Burdekin Agricultural College (BAC) logs and 41.9% (range 20 to 61%) for Katherine (NT) logs. These figures are about 10% higher than compared to 30-year-old Khaya study by Armstrong et al. (2007) however they are inflated as the green boards were not docked to remove wane prior to being tallied. Of the recovered sawn, dried and dressed volume from the BAC logs, based on the cambial face of boards, 27% could potentially be used for select grade, 40% for medium feature grade and 26% for high feature grades. The heart faces had a slightly higher recovery of select (30%) and medium feature (43%) grade boards with a reduction in the volume of high feature (22%) and reject (6%) grade boards. Distribution of board grades for the NT site aged 14 years followed very similar trends to those of the BAC site boards with an average (between facial and cambial face) 27% could potentially be used for select grade, 42% for medium feature grade, 26% for high feature grade and 5% reject. Relatively to some other subtropical eucalypts, there was a low incidence of borer attack. The major grade limiting defects for both medium and high feature grade boards recovered from the BAC site were knots and wane. The presence of large knots may reflect both management practices and the nature of the genetic material at the site. This stand was not managed for timber production with a very late pruning implemented at about age 12 years. The large amount of wane affected boards is indicative of logs with a large taper and the presence of significant sweep. Wane, knots and skip were the major grade limiting defects for the NT site reflecting considerable amounts of sweep with large taper as might be expected in younger trees. The green veneer recovered from billets of seven Khaya trees rotary peeled on a spindleless lathe produced a recovery of 83% of green billet volume. Dried veneer recovery ranged from 40 to 74 % per billet with an average of 64%. All of the recovered grades were suitable for use in structural ply in accordance to AS/NZ 2269: 2008. The majority of veneer sheets recovered from all billets was C grade (27%) with 20% making D grade and 13% B grade. Total dry sliced veneer recovery from the logs of the two largest logs from each location was estimated to be 41.1%. Very positive results have been recorded in this small scale study. The amount of colour development observed and the very reasonable recoveries of both sawn and veneer products, with a good representation of higher grades in the product distribution, is encouraging. The prospects for significant improvement in these results from well managed and productive stands grown for high quality timber should be high. Additionally, the study has shown the utility of non-destructive evaluation techniques for use in tree improvement programs to improve the quality of future plantations. A few trees combined several of the traits desired of individuals for a first breeding population. Fortunately, the two most promising trees (32, 19) had already been selected for breeding on external traits, and grafts of them are established in the seed orchard.
Resumo:
PURPOSE To develop and test decision tree (DT) models to classify physical activity (PA) intensity from accelerometer output and Gross Motor Function Classification System (GMFCS) classification level in ambulatory youth with cerebral palsy (CP); and 2) compare the classification accuracy of the new DT models to that achieved by previously published cut-points for youth with CP. METHODS Youth with CP (GMFCS Levels I - III) (N=51) completed seven activity trials with increasing PA intensity while wearing a portable metabolic system and ActiGraph GT3X accelerometers. DT models were used to identify vertical axis (VA) and vector magnitude (VM) count thresholds corresponding to sedentary (SED) (<1.5 METs), light PA (LPA) (>/=1.5 and <3 METs) and moderate-to-vigorous PA (MVPA) (>/=3 METs). Models were trained and cross-validated using the 'rpart' and 'caret' packages within R. RESULTS For the VA (VA_DT) and VM decision trees (VM_DT), a single threshold differentiated LPA from SED, while the threshold for differentiating MVPA from LPA decreased as the level of impairment increased. The average cross-validation accuracy for the VC_DT was 81.1%, 76.7%, and 82.9% for GMFCS levels I, II, and III, respectively. The corresponding cross-validation accuracy for the VM_DT was 80.5%, 75.6%, and 84.2%, respectively. Within each GMFCS level, the decision tree models achieved better PA intensity recognition than previously published cut-points. The accuracy differential was greatest among GMFCS level III participants, in whom the previously published cut-points misclassified 40% of the MVPA activity trials. CONCLUSION GMFCS-specific cut-points provide more accurate assessments of MVPA levels in youth with CP across the full spectrum of ambulatory ability.
Resumo:
BACKGROUND Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. OBJECTIVE The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. METHODS Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. RESULTS All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. LIMITATIONS This PA protocol consisted of controlled activity trials. CONCLUSIONS Accelerometers provide valid and reliable measures of PA intensity among youth with CP.
Resumo:
Aim This study evaluated the validity of the OMNI Walk/Run Rating of Perceived Exertion (OMNI-RPE) scores with heart rate and oxygen consumption (VO2) for children and adolescents with cerebral palsy (CP). Method Children and adolescents with CP, aged 6 to 18 years and Gross Motor Function Classification System (GMFCS) levels I to III completed a physical activity protocol with seven trials ranging in intensity from sedentary to moderate-to-vigorous. VO2 and heart rate were recorded during the physical activity trials using a portable indirect calorimeter and heart rate monitor. Participants reported OMNI-RPE scores for each trial. Concurrent validity was assessed by calculating the average within-subject correlation between OMNI-RPE ratings and the two physiological indices. Results For the correlational analyses, 48 participants (22 males, 26 females; age 12y 6mo, SD 3y 4mo) had valid bivariate data for VO2 and OMNI-RPE, while 40 participants (21 males, 19 females; age 12y 5mo, SD 2y 9mo) had valid bivariate data for heart rate and OMNI-RPE. VO2 (r=0.80; 95% CI 0.66–0.88) and heart rate (r=0.83; 95% CI 0.70–0.91) were moderately to highly correlated to OMNI-RPE scores. No difference was found for the correlation of physiological data and OMNI-RPE scores across the three GMFCS levels. The OMNI-RPE scores increased significantly in a dose-response manner (F6,258=116.1, p<0.001) as exercise intensity increased from sedentary to moderate-to-vigorous. Interpretation OMNI-RPE is a clinically feasible option to monitor exercise intensity in ambulatory children and adolescents with CP.
Resumo:
Due to the recent development in CCD technology aerial photography is now slowly changing from film to digital cameras. This new aspect in remote sensing allows and requires also new automated analysis methods. Basic research on reflectance properties of natural targets is needed so that computerized processes could be fully utilized. For this reason an instrument was developed at Finnish Geodetic Institute for measurement of multiangular reflectance of small remote sensing targets e.g. forest understorey or asphalt. Finnish Geodetic Institute Field Goniospectrometer (FiGIFiGo) is a portable device that is operated by 1 or 2 persons. It can be reassembled to a new location in 15 minutes and after that a target's multiangular reflectance can be measured in 10 - 30 minutes (with one illumination angle). FiGIFiGo has effective spectral range approximately from 400 nm to 2000 nm. The measurements can be made either outside with sunlight or in laboratory with 1000 W QTH light source. In this thesis FiGIFiGo is introduced and the theoretical basis of such reflectance measurements are discussed. A new method is introduced for extraction of subcomponent proportions from reflectance of a mixture sample, e.g. for retrieving proportion of lingonberry's reflectance in observation of lingonberry-lichen sample. This method was tested by conducting a series of measurements on reflectance properties of artificial samples. The component separation method yielded sound results and brought up interesting aspects in targets' reflectances. The method and the results still need to be verified with further studies, but the preliminary results imply that this method could be a valuable tool in analysis of such mixture samples.
Resumo:
The world is facing an energy crisis due to exponential population growth and limited availability of fossil fuels. Over the last 20 years, carbon, one of the most abundant materials found on earth, and its allotrope forms such as fullerenes, carbon nanotubes and graphene have been proposed as sources of energy generation and storage because of their extraordinary properties and ease of production. Various approaches for the synthesis and incorporation of carbon nanomaterials in organic photovoltaics and supercapacitors have been reviewed and discussed in this work, highlighting their benefits as compared to other materials commonly used in these devices. The use of fullerenes, carbon nanotubes and graphene in organic photovoltaics and supercapacitors is described in detail, explaining how their remarkable properties can enhance the efficiency of solar cells and energy storage in supercapacitors. Fullerenes, carbon nanotubes and graphene have all been included in solar cells with interesting results, although a number of problems are still to be overcome in order to achieve high efficiency and stability. However, the flexibility and the low cost of these materials provide the opportunity for many applications such as wearable and disposable electronics or mobile charging. The application of carbon nanotubes and graphene to supercapacitors is also discussed and reviewed in this work. Carbon nanotubes, in combination with graphene, can create a more porous film with extraordinary capacitive performance, paving the way to many practical applications from mobile phones to electric cars. In conclusion, we show that carbon nanomaterials, developed by inexpensive synthesis and process methods such as printing and roll-to-roll techniques, are ideal for the development of flexible devices for energy generation and storage – the key to the portable electronics of the future.
Resumo:
Portable music players have made it possible to listen to a personal collection of music in almost every situation, and they are often used during some activity to provide a stimulating audio environment. Studies have demonstrated the effects of music on the human body and mind, indicating that selecting music according to situation can, besides making the situation more enjoyable, also make humans perform better. For example, music can boost performance during physical exercises, alleviate stress and positively affect learning. We believe that people intuitively select different types of music for different situations. Based on this hypothesis, we propose a portable music player, AndroMedia, designed to provide personalised music recommendations using the user’s current context and listening habits together with other user’s situational listening patterns. We have developed a prototype that consists of a central server and a PDA client. The client uses Bluetooth sensors to acquire context information and logs user interaction to infer implicit user feedback. The user interface also allows the user to give explicit feedback. Large user interface elements facilitate touch-based usage in busy environments. The prototype provides the necessary framework for using the collected information together with other user’s listening history in a context- enhanced collaborative filtering algorithm to generate context-sensitive recommendations. The current implementation is limited to using traditional collaborative filtering algorithms. We outline the techniques required to create context-aware recommendations and present a survey on mobile context-aware music recommenders found in literature. As opposed to the explored systems, AndroMedia utilises other users’ listening habits when suggesting tunes, and does not require any laborious set up processes.