868 resultados para Statistic validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although CD4 cell count monitoring is used to decide when to start antiretroviral therapy in patients with HIV-1 infection, there are no evidence-based recommendations regarding its optimal frequency. It is common practice to monitor every 3 to 6 months, often coupled with viral load monitoring. We developed rules to guide frequency of CD4 cell count monitoring in HIV infection before starting antiretroviral therapy, which we validated retrospectively in patients from the Swiss HIV Cohort Study.Methodology/Principal Findings: We built up two prediction rules ("Snap-shot rule" for a single sample and "Track-shot rule" for multiple determinations) based on a systematic review of published longitudinal analyses of CD4 cell count trajectories. We applied the rules in 2608 untreated patients to classify their 18 061 CD4 counts as either justifiable or superfluous, according to their prior >= 5% or < 5% chance of meeting predetermined thresholds for starting treatment. The percentage of measurements that both rules falsely deemed superfluous never exceeded 5%. Superfluous CD4 determinations represented 4%, 11%, and 39% of all actual determinations for treatment thresholds of 500, 350, and 200x10(6)/L, respectively. The Track-shot rule was only marginally superior to the Snap-shot rule. Both rules lose usefulness for CD4 counts coming near to treatment threshold.Conclusions/Significance: Frequent CD4 count monitoring of patients with CD4 counts well above the threshold for initiating therapy is unlikely to identify patients who require therapy. It appears sufficient to measure CD4 cell count 1 year after a count > 650 for a threshold of 200, > 900 for 350, or > 1150 for 500x10(6)/L, respectively. When CD4 counts fall below these limits, increased monitoring frequency becomes advisable. These rules offer guidance for efficient CD4 monitoring, particularly in resource-limited settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the quickening pace of crash reporting, the statistical editing of data on a weekly basis, and the ability to provide working databases to users at CTRE/Iowa Traffic Safety Data Service, the University of Iowa, and the Iowa DOT, databases that would be considered incomplete by past standards of static data files are in “public use” even as the dynamic nature of the central DOT database allows changes to be made to both the aggregate of data and to the individual crashes already reported. Moreover, “definitive” analyses of serious crashes will, by their nature, lag seriously behind the preliminary data files. Even after these analyses, the dynamic nature of the mainframe data file means that crash numbers can continue to change long after the incident year. The Iowa DOT, its Office of Driver Services (the “data owner”), and institutional data users/distributors must establish data use, distribution, and labeling protocols to deal with the new, dynamic nature of data. In order to set these protocols, data must be collected concerning the magnitude of difference between database records and crash narratives and diagrams. This study determines the difference between database records and crash narratives for the Iowa Department of Transportation’s Office of Traffic and Safety crash database and the impacts of this difference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le ROTEM est un test de coagulation réalisable au près du malade qui permet d'objectiver la coagulopathie, de distinguer la contribution des différents éléments du système de coagulation et de cibler les produits procoagulants comme le plasma frais congelé (PFC), les plaquettes, le fibrinogène et les facteurs de coagulation purifiés ou les antifibrinolytiques. 3 des tests disponibles pour le ROTEM sont: EXTEM, INTEM, HEPTEM. Le premier test est stable sous hautes doses d'héparine alors que le deuxième est très sensible à sa présence. Dans le dernier test on rajoute de l'héparinase pour mettre en évidence l'éventuel effet résiduel de l'héparine en le comparant à l'INTEM. Idéalement, le ROTEM devrait être effectué avant la fin du bypass cardiopulmonaire (CEC), donc sous anticoagulation maximale pas héparine, afin de pouvoir administrer des produits pro¬coagulants dans les délais les plus brefs et ainsi limiter au maximum les pertes sanguines. En effet la commande et la préparation de certains produits procoagulants peut prendre plus d'une heure. Le but de cette étude est de valider l'utilisation du ROTEM en présence de hautes concentrations d'héparine. Il s'agit d'une étude observationnelle prospective sur 20 patients opérés électivement de pontages aorto-coronariens sous CEC. Méthode : l'analyse ROTEM a été réalisée avant l'administration d'héparine (TO), 10 minutes après l'administration d'héparine (Tl), à la fin de la CEC (T2) et 10 minutes après la neutralisation de l'anticoagulation avec la protamine (T3). L'état.d'héparinisation a été évalué par l'activité anti-Xa à T1,T2,T3. Résultats : Comparé à TO, la phase de polymérisation de la cascade de coagulation et l'interaction fibrine-plaquettes sont significativement détériorées par rapport à Tl pour les canaux EXTEM et HEPTEM. A T2 l'analyse EXTEM et INTEM sont comparables à celles de EXTEM et HEPTEM à T3. Conclusion: les hautes doses d'héparine utilisées induisent une coagulopathie qui reste stable durant toute la durée de la CEC et qui persiste même après la neutralisation de l'anticoagulation. Les mesures EXTEM et HEPTEM sont donc valides en présence de hautes concentrations d'héparine et peuvent être réalisés pendant la CEC avant l'administration de protamine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: A rapid and simple HPLC-MS method was developed for the simultaneousdetermination of antidementia drugs, including donepezil, galantamine, rivastigmineand its major metabolite NAP 226 - 90, and memantine, for TherapeuticDrug Monitoring (TDM). In the elderly population treated with antidementiadrugs, the presence of several comorbidities, drug interactions resulting frompolypharmacy, and variations in drug metabolism and elimination, are possiblefactors leading to the observed high interindividual variability in plasma levels.Although evidence for the benefit of TDM for antidementia drugs still remains tobe demonstrated, an individually adapted dosage through TDM might contributeto minimize the risk of adverse reactions and to increase the probability of efficienttherapeutic response. Methods: A solid-phase extraction procedure with amixed-mode cation exchange sorbent was used to isolate the drugs from 0.5 mL ofplasma. The compounds were analyzed on a reverse-phase column with a gradientelution consisting of an ammonium acetate buffer at pH 9.3 and acetonitrile anddetected by mass spectrometry in the single ion monitoring mode. Isotope-labeledinternal standards were used for quantification where possible. The validatedmethod was used to measure the plasma levels of antidementia drugs in 300patients treated with these drugs. Results: The method was validated accordingto international standards of validation, including the assessment of the trueness(-8 - 11 %), the imprecision (repeatability: 1-5%, intermediate imprecision:2 - 9 %), selectivity and matrix effects variability (less than 6 %). Furthermore,short and long-term stability of the analytes in plasma was ascertained. Themethod proved to be robust in the calibrated ranges of 1 - 300 ng/mL for rivastigmineand memantine and 2 - 300 mg/mL for donepezil, galantamine and NAP226 - 90. We recently published a full description of the method (1). We found ahigh interindividual variability in plasma levels of these drugs in a study populationof 300 patients. The plasma level measurements, with some preliminaryclinical and pharmacogenetic results, will be presented. Conclusion: A simpleLC-MS method was developed for plasma level determination of antidementiadrugs which was successfully used in a clinical study with 300 patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A family of scaling corrections aimed to improve the chi-square approximation of goodness-of-fit test statistics in small samples, large models, and nonnormal data was proposed in Satorra and Bentler (1994). For structural equations models, Satorra-Bentler's (SB) scaling corrections are available in standard computer software. Often, however, the interest is not on the overall fit of a model, but on a test of the restrictions that a null model say ${\cal M}_0$ implies on a less restricted one ${\cal M}_1$. If $T_0$ and $T_1$ denote the goodness-of-fit test statistics associated to ${\cal M}_0$ and ${\cal M}_1$, respectively, then typically the difference $T_d = T_0 - T_1$ is used as a chi-square test statistic with degrees of freedom equal to the difference on the number of independent parameters estimated under the models ${\cal M}_0$ and ${\cal M}_1$. As in the case of the goodness-of-fit test, it is of interest to scale the statistic $T_d$ in order to improve its chi-square approximation in realistic, i.e., nonasymptotic and nonnormal, applications. In a recent paper, Satorra (1999) shows that the difference between two Satorra-Bentler scaled test statistics for overall model fit does not yield the correct SB scaled difference test statistic. Satorra developed an expression that permits scaling the difference test statistic, but his formula has some practical limitations, since it requires heavy computations that are notavailable in standard computer software. The purpose of the present paper is to provide an easy way to compute the scaled difference chi-square statistic from the scaled goodness-of-fit test statistics of models ${\cal M}_0$ and ${\cal M}_1$. A Monte Carlo study is provided to illustrate the performance of the competing statistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pudendal neuropathy is common. The diagnosis is clinical and the confirmation is electrophysiological. Distal pudendal nerve latencies have been used but they are unspecific and do not allow to localize the site of compression. A preliminary electrophysiological study has suggested separate innervations of the anterior and the posterior anal sphincter quadrants, so diverging from what main anatomy textbooks teach. By detailed dissections of pudendal nerve region we can confirm a dichotomy in the innervation of the two quadrants. Therefore, it seems feasible, by using the differences of staged sacral reflexes, to better localize the compressive neuropathy, with a stimulation of the clitoris and by recording latencies of different muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: A clinical decision rule to improve the accuracy of a diagnosis of influenza could help clinicians avoid unnecessary use of diagnostic tests and treatments. Our objective was to develop and validate a simple clinical decision rule for diagnosis of influenza. METHODS: We combined data from 2 studies of influenza diagnosis in adult outpatients with suspected influenza: one set in California and one in Switzerland. Patients in both studies underwent a structured history and physical examination and had a reference standard test for influenza (polymerase chain reaction or culture). We randomly divided the dataset into derivation and validation groups and then evaluated simple heuristics and decision rules from previous studies and 3 rules based on our own multivariate analysis. Cutpoints for stratification of risk groups in each model were determined using the derivation group before evaluating them in the validation group. For each decision rule, the positive predictive value and likelihood ratio for influenza in low-, moderate-, and high-risk groups, and the percentage of patients allocated to each risk group, were reported. RESULTS: The simple heuristics (fever and cough; fever, cough, and acute onset) were helpful when positive but not when negative. The most useful and accurate clinical rule assigned 2 points for fever plus cough, 2 points for myalgias, and 1 point each for duration <48 hours and chills or sweats. The risk of influenza was 8% for 0 to 2 points, 30% for 3 points, and 59% for 4 to 6 points; the rule performed similarly in derivation and validation groups. Approximately two-thirds of patients fell into the low- or high-risk group and would not require further diagnostic testing. CONCLUSION: A simple, valid clinical rule can be used to guide point-of-care testing and empiric therapy for patients with suspected influenza.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Most scales that assess the presence and severity of psychotic symptoms often measure a broad range of experiences and behaviours, something that restricts the detailed measurement of specific symptoms such as delusions or hallucinations. The Psychotic Symptom Rating Scales (PSYRATS) is a clinical assessment tool that focuses on the detailed measurement of these core symptoms. The goal of this study was to examine the psychometric properties of the French version of the PSYRATS. METHODS: A sample of 103 outpatients suffering from schizophrenia or schizoaffective disorders and presenting persistent psychotic symptoms over the previous three months was assessed using the PSYRATS. Seventy-five sample participants were also assessed with the Positive And Negative Syndrome Scale (PANSS). RESULTS: ICCs were superior to .90 for all items of the PSYRATS. Factor analysis replicated the factorial structure of the original version of the delusions scale. Similar to previous replications, the factor structure of the hallucinations scale was partially replicated. Convergent validity indicated that some specific PSYRATS items do not correlate with the PANSS delusions or hallucinations. The distress items of the PSYRATS are negatively correlated with the grandiosity scale of the PANSS. CONCLUSIONS: The results of this study are limited by the relatively small sample size as well as the selection of participants with persistent symptoms. The French version of the PSYRATS partially replicates previously published results. Differences in factor structure of the hallucinations scale might be explained by greater variability of its elements. The future development of the scale should take into account the presence of grandiosity in order to better capture details of the psychotic experience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to compare the performance of twopredictive radiological models, logistic regression (LR) and neural network (NN), with five different resampling methods. One hundred and sixty-seven patients with proven calvarial lesions as the only known disease were enrolled. Clinical and CT data were used for LR and NN models. Both models were developed with cross validation, leave-one-out and three different bootstrap algorithms. The final results of each model were compared with error rate and the area under receiver operating characteristic curves (Az). The neural network obtained statistically higher Az than LR with cross validation. The remaining resampling validation methods did not reveal statistically significant differences between LR and NN rules. The neural network classifier performs better than the one based on logistic regression. This advantage is well detected by three-fold cross-validation, but remains unnoticed when leave-one-out or bootstrap algorithms are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'index de consommation du glucose, SUV pour standardized uptake value, est largement utilisé en tomographie par émission de positons (TEP) pour quantifier la concentration relative de [18F]2-fluoro-2-désoxy-D-glucose (18F-FDG) dans les tissus. Cependant, cet indice dépend de nombreux facteurs méthodologiques et biologiques et son utilisation fait débat. Il est donc primordial d'instaurer un contrôle qualité régulier permettant d'assurer la stabilité de la mesure des indices quantitatifs. Dans cette optique, un fantôme spécifique avec inserts cylindriques de différentes tailles a été développé. L'objectif de cette étude est de montrer la sensibilité et l'intérêt de ce fantôme. Méthodes. - La sensibilité du fantôme a été étudiée à travers la mesure des SUV et des coefficients de recouvrement (RC). Plusieurs méthodes de mesure ont été utilisées. Les données ont été reconstruites en utilisant les algorithmes de routine clinique. Nous avons étudié la variation des RC en fonction de la taille des cylindres et le changement relatif de fixation, en utilisant des activités différentes. Le fantôme a ensuite été testé sur l'appareil d'un autre centre. Résultats. - Pour toutes les méthodes de mesure, une forte variation des RC avec la taille des cylindres, de l'ordre de 50 %, a été obtenue. Ce fantôme a également permis de mesurer un changement relatif de fixation qui s'est révélé être indépendant de la méthode de mesure. Malgré un étalonnage des deux systèmes TEP/TDM, des différences de quantification d'environ 20 % ont subsisté. Conclusion. - Les résultats obtenus montrent l'intérêt de ce fantôme dans le cadre du suivi des mesures quantitatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quantitative model of water movement within the immediate vicinity of an individual root is developed and results of an experiment to validate the model are presented. The model is based on the assumption that the amount of water transpired by a plant in a certain period is replaced by an equal volume entering its root system during the same time. The model is based on the Darcy-Buckingham equation to calculate the soil water matric potential at any distance from a plant root as a function of parameters related to crop, soil and atmospheric conditions. The model output is compared against measurements of soil water depletion by rice roots monitored using γ-beam attenuation in a greenhouse of the Escola Superior de Agricultura "Luiz de Queiroz"/Universidade de São Paulo(ESALQ/USP) in Piracicaba, State of São Paulo, Brazil, in 1993. The experimental results are in agreement with the output from the model. Model simulations show that a single plant root is able to withdraw water from more than 0.1 m away within a few days. We therefore can assume that root distribution is a less important factor for soil water extraction efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To validate a revision of the Mini Nutritional Assessment short-form (MNA(R)-SF) against the full MNA, a standard tool for nutritional evaluation. METHODS: A literature search identified studies that used the MNA for nutritional screening in geriatric patients. The contacted authors submitted original datasets that were merged into a single database. Various combinations of the questions on the current MNA-SF were tested using this database through combination analysis and ROC based derivation of classification thresholds. RESULTS: Twenty-seven datasets (n=6257 participants) were initially processed from which twelve were used in the current analysis on a sample of 2032 study participants (mean age 82.3y) with complete information on all MNA items. The original MNA-SF was a combination of six questions from the full MNA. A revised MNA-SF included calf circumference (CC) substituted for BMI performed equally well. A revised three-category scoring classification for this revised MNA-SF, using BMI and/or CC, had good sensitivity compared to the full MNA. CONCLUSION: The newly revised MNA-SF is a valid nutritional screening tool applicable to geriatric health care professionals with the option of using CC when BMI cannot be calculated. This revised MNA-SF increases the applicability of this rapid screening tool in clinical practice through the inclusion of a "malnourished" category.