986 resultados para Single-platform Trucount Assay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The variability of a fragment of the nucleocapsid gene of orchid fleck virus (OFV) was investigated by single-strand conformational polymorphism (SSCP) analysis and nucleotide sequencing. Forty-eight samples of 18 genera of orchids were collected from Brazil, Costa Rica and Australia. The SSCP analysis yielded six different band patterns, and phylogenetic analysis based on the nucleotide fragment sequence obtained in this work and six available in GenBank showed two different groups, one with isolates 023Germany and So-Japan, and other with the rest of the isolates. None of the analyses showed geographic correlation among the Brazilian strains. The data obtained in this study showed a low genetic variation in this region of the genome; the d(N)/d(S) ratio of 0.251-0.405 demonstrated a negative selective pressure that maintains the stability of the analyzed fragments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The resazurin microtitre plate assay (REMA) was evaluated to determine the susceptibility of Mycobacterium tuberculosis to pyrazinamide, and was compared with the broth microdilution method (BMM), the absolute concentration method (ACM) and pyrazinamidase (PZase) determination. Methods: Thirty-four M. tuberculosis clinical isolates (26 susceptible and 8 resistant to pyrazinamide) and reference strains M. tuberculosis H37Rv ATCC 27294 and Mycobacterium bovis AN5 were tested. Results: REMA and BMM showed 100% specificity and sensitivity when compared with ACM; BMM, however, demanded more reading time. The PZase determination assay showed 87.50% and 100% sensitivity and specificity, respectively. Conclusions: All tested methods in this preliminary study showed excellent sensitivity and specificity for the determination of pyrazinamide susceptibility of M. tuberculosis, but REMA was faster, low-cost and easy to perform and interpret. Additional studies evaluating REMA for differentiating pyrazinamide-resistant and-susceptible M. tuberculosis should be conducted on an extended panel of clinical isolates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Restriction fragment length polymorphism (RFLP) is a common molecular assay used for genotyping, and it requires validated quality control procedures to prevent mistyping caused by impaired endonuclease activity. We have evaluated the usefulness of a plasmid-based internal control in RFLP assays. Results: Blood samples were collected from 102 individuals with acute myocardial infarction (AMI) and 108 non-AMI individuals (controls) for DNA extraction and laboratory analyses. The 1196C> T polymorphism in the toll-like receptor 4 (TLR4) gene was amplified by mismatched-polymerase chain reaction (PCR). Amplicons and pBluescript II SK-plasmid were simultaneously digested with endonuclease HincII. Fragments were separated on 2% agarose gels. Plasmid was completely digested using up to 55.2 nmL/L DNA solutions and 1 mu L PCR product. Nevertheless, plasmid DNA with 41.4 nM or higher concentrations was incompletely digested in the presence of 7 mL PCR product. In standardized conditions, TLR4 1196C> T variant was accurately genotyped. TLR4 1196T allele frequency was similar between AMI (3.1%) and controls (2.0%, p = 0.948). TLR4 SNP was not associated with AMI in this sample population. In conclusion, the plasmid-based control is a useful approach to prevent mistyping in RFLP assays, and it is validate for genetic association studies such as TLR4 1196C> T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to verify the possible inclusion of the Salmonella/microsome mutagenicity assay in a groundwater monitoring program as a complementary assay to assess water quality. Groundwater samples belonging to seven wells from different types of aquifers were analyzed. Three different methods for sample preparation were used: membrane filtration; liquid-liquid and XAD-4 extraction. The filtered samples were tested using TA98, TA100, YG1041 and YG1042 and the water extracts only with TA98 and TA100. No mutagenic activity was observed in any of the 16 filtered samples tested. Out of the 10 samples analyzed using XAD-4 extraction, five showed mutagenic activity with potency ranging from 130 to 1500 revertants/L. Concerning the liquid-liquid extraction, from the 11 samples analyzed, 3 showed mutagenicity. The XAD-4 extraction was the most suitable sample preparation. TA98 without S9 was found to be the most sensitive testing condition. The wells presenting water samples with mutagenic activity belonged to unconfined aquifers, which are more vulnerable to contamination. The data suggest that Salmonella/microsome assay can be used as an efficient screening tool to monitor groundwater for mutagenic activity. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New fast liquid chromatographic and capillary zone electrophoresis methods were developed and validated for simultaneous determination of atenolol and chlortalidone in combined dose tablets. The reversed phase HPLC method was carried out on a CN LiChrosorb (R) (125 x 4 mm, 5 mu m) column. The CZE method was carried out on an uncoated fused-silica capillary of 30 cm x 75 mu m i.d. with 25 mmol L(-1) sodium tetraborate, pH 9.4. The total analysis time was <6 and <2.5 min for HPLC and CZE methods, respectively. Both methods can be used for stability studies as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tramadol is a well tolerated and effective analgesic used to treat moderate to severe pain. Several generic formulations of tramadol are available in Brazil; however, published information regarding their bioequivalence in the Brazilian population is not available. A study was designed for Brazilian regulatory authorities to allow marketing of a generic formulation. Objective: The purpose of this study was to compare the bioequivalence of 2 commercial tablet preparations containing tramadol 100 mg marketed for use in Brazil. Methods: A randomized, open-label, 2 x 2 crossover study was performed in healthy Brazilian volunteers under fasting conditions with a washout period of 12 days. Two tablet formulations of tramadol 100 mg (test and reference formulations) were administered as a single oral dose, and blood samples were collected over 24 hours. Tramadol plasma concentrations were quantified using a validated HPLC method. A plasma concentration time profile was generated for each volunteer and then mean values were determined, from which C(max), T(max), AUC(0-t), AUC(0-infinity), k(e), and t(1/2) were calculated using a noncompartmental model. Bioequivalence between the products was determined by calculating 90% CIs for the ratios of C(max), AUC(0-t), and AUC(0-infinity) values for the test and reference products using log-transformed data. Tolerability was assessed by monitoring vital signs (temperature, blood pressure, heart rate), laboratory tests (hematology, blood biochemistry, hepatic function, urinalysis), and interviews with the volunteers before medication administration and every 2 hours during the study. Results: Twenty-six healthy volunteers (13 men, 13 women) were enrolled in and completed the study. Mean (SD) age was 30 (6.8) years (range, 21-44 years), mean weight was 64 (8.3) kg (range, 53-79 kg), and mean height was 166 (6.4) cm (range, 155-178 cm). The 90% CIs for the ratios of C(max) (1.01-1.17), AUC(0-t) (1.00-1.13), and AUC(0-infinity) (1.00-1.14) values for the test and reference products fell within the interval of 0.80 to 1.25 proposed by most regulatory agencies, including the Brazilian regulatory body. No clinically important adverse effects were reported; only mild somnolence was reported by 4 volunteers and mild headaches by 5 volunteers, and there was no need to use medication to treat these symptoms. Conclusion: Pharmacokinetic analysis in these healthy Brazilian volunteers suggested that the test and reference formulations of tramadol 100-mg tablets met the regulatory requirements to assume bio-equivalence based on the Brazilian regulatory definition. (Clin Ther 2010;32:758-765) (C) 2010 Excerpta Medica Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08-5.70 mu g mL(-1) (r = 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 mu g mL(-1), respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adsorption of Ni(2+), Zn(2+) or Pb(2+) by dry biomass of Arthrospira (Spirulina) platensis and Chlorella vulgaris was studied as a function of contact time and initial metal concentration. The zero point of charge calculated for these biosorbents (pH(zpc) 4.0 and 3.4, respectively) and additional pH tests suggested the use of pH in the range 5.0-5.5 for the experiments. The equilibrium isotherms were evaluated in terms of maximum sorption capacity and sorption affinity. The pseudo first and second order kinetic models were considered to interpret the experimental data, and the latter best described the adsorption system. Both the Freundlich and Langmuir models were shown to well describe the sorption isotherms, thus suggesting an intermediate mono/multilayer sorption mechanism. Compared to A. platensis (q(e) = 0.354, 0.495 and 0.508 mmol g(-1) for Ni(2+), Pb(2)+ and Zn(2+), respectively), C. vulgaris behaved as a better biosorbent because of higher equilibrium sorption capacity (q(e) = 0.499, 0.634 and 0.664 mmol g(-1), respectively). The removal efficiency decreased with increasing metal concentration, pointing out a passive adsorption process involving the active sites on the surface of the biomasses. The FT-IR spectroscopy evidenced that ions removal occurred mainly by interaction between metal and carboxylate groups present on both the cell walls. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was the design of a set of benzofuroxan derivatives as antimicrobial agents exploring the physicochemical properties of the related substituents. Topliss` decision tree approach was applied to select the substituent groups. Hierarchical cluster analysis was also performed to emphasize natural clusters and patterns. The compounds were obtained using two synthetic approaches for reducing the synthetic steps as well as improving the yield. The minimal inhibitory concentration method was employed to evaluate the activity against multidrug-resistant Staphylococcus aureus strains. The most active compound was 4-nitro-3-(trifluoromethyl)[N`-(benzofuroxan-5-yl) methylene] benzhydrazide (MIC range 12.7-11.4 mu g/mL), pointing out that the antimicrobial activity was indeed influenced by the hydrophobic and electron-withdrawing property of the substituent groups 3-CF(3) and 4-NO(2), respectively. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate an agar diffusion method through the parameters linearity, precision and accuracy, to quantify apramycin in soluble powder. The calibration curve of apramycin was constructed by plotting log of concentrations (mu g ml(-1)) versus zone diameter (mm) and shows good linearity in the range of 1.0-4.0 mu g.ml(-1). The precision of the assay was determined by assaying samples at the same day (repeatability - R.S.D. = 2.00%) and on different days (intermediate precision - R.S.D. = 5.06%) and indicate good precision. The accuracy expresses the agreement between the accepted value and the value found. The mean recovery was found to be 100.49 % for apramycin soluble powder. The results indicated that the microbiological assay proposed in this work hold linearity, precision and accuracy being an acceptable alternative method for routine quality control of apramycin in the pharmaceutical dosage form studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the pharmacokinetics of tetracycline in plasma, synovial fluid, and milk following either a single systemic intravenous (i.v.) injection or a single i.v. regional antibiosis (IVRA) administration of tetracycline hydrochloride to dairy cattle with papillomatous digital dermatitis (PDD). To this end, plasma and synovial fluid tetracycline concentrations were compared with the minimal inhibitory concentration (MIC) values of the major bacteria, which are known to cause digital diseases and thus assess its efficacy in PDD. Residual tetracycline concentrations in milk from cows treated by both methods were also determined. Twelve Holstein cows with various stages of PDD were randomly assigned to two groups of six animals. Group 1 received a single systemic i.v. injection of 10 mg/kg of tetracycline hydrochloride. Group 2 received 1000 mg of tetracycline hydrochloride by IVRA of the affected limb. Blood, synovial fluid and milk samples were taken prior to tetracycline administration (time 0 control), and then at 22, 45 and 82 min, and 2, 3, 4, 6, 8, 12, 24, 48, 72, 96, and 120 h following drug administration. Tetracycline concentrations were determined by high-performance liquid chromatography. Mean tetracycline plasma and milk concentrations in Group 1 were higher than Group 2. The opposite was observed for synovial fluid concentrations. Group 2 synovial fluid concentrations were higher than the MIC value over 24 h for the bacteria most frequently responsible for claw disease. Compared with i.v. administration, IVRA administration of tetracycline produced very high synovial fluid and low plasma and milk concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New rapid first-derivative spectrophotometric (UVDS) and a stability-indicating high performance liquid chromatographic (HPLC) methods were developed, validated and successfully applied in the analysis of loratadine (LT) in tablets and syrups. In the UVDS method, 0.1 M HCl was used as solvent. The measurements were made at 312.4 nm in the first order derivative spectra. The HPLC method was carried out on a RP-18 column with a mobile phase composed of methanol-water-tetrahydrofuran (50:30:20, v/v/v). UV detection was made at 247 nm. For HPLC methods the total analysis time was <3min, adequate for routine quality control of tablets and syrups containing loratadine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the responses of the Salmonella/microsome microsuspension assay with the new microplate fluctuation protocol (MPF) for the evaluation of the mutagenic activity of environmental samples. Organic extracts of total particulate atmospheric air samples, surface waters, and effluents were tested in dose-response experiments. The assays were performed with strain TA98 in the absence and presence of S9 mix. Both protocols produced similar results, despite the fact that the maximum score of the MPF is limited to 48 wells, whereas in the regular plate assay it is possible to count up to 1,500 colonies using an automatic counter. Similar sensitivities based on the lowest dose that resulted in a positive response were obtained for both assays. The MPF procedure is less laborious (e.g., all-liquid format, use of multi-channel pipettors) and allows for automation of the pipetting and dispensing steps, thus, reducing time of the analysis which is particularly important in environmental quality monitoring programs or in effect-directed analysis. The results show that the MPF procedure is a promising tool to test environmental samples for mutagenic activity. Environ. Mol. Mutagen. 51:31-38, 2010. (C) 2009 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of commercially available test kits for Chagas disease for use in blood bank screening is difficult due to a lack of large and well-characterized specimen panels. This study presents a collaborative effort of Latin American blood centers and the World Health Organization (WHO) to establish such a panel. A total of 437 specimens, from 10 countries were collected and sent to the WHO Collaborating Center in Sao Paulo and used to evaluate 19 screening assays during 2001 through 2005. Specimens were assigned a positive or negative status based on concordant results in at least three of the four confirmatory assays (indirect immunofluorescence, Western blot, radioimmunoprecipitation assay, and recombinant immunoblot). Of the 437 specimens, 168 (39%) were characterized as positive, 262 (61%) were characterized as negative, and 7 (2%) were judged inconclusive and excluded from the analysis. Sensitivity and specificity varied considerably: 88 to 100 and 60 to 100 percent, respectively. Overall, enzyme immunoassays (EIAs) performed better than the other screening assays. Four EIAs had both parameters higher than 99 percent. Of the four confirmatory assays, only the RIPA gave a 100 percent agreement with the final serologic status of the specimens. The sensitivities and specificities of at least four of the commercially available EIAs for Chagas disease are probably high enough to justify their use for single-assay screening of blood donations. Our data suggest that the majority of commercially available indirect hemagglutination assays should not be used for blood donor screening and that the RIPA could be considered a gold standard for evaluating the performance of other assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Zidovudine is a thymidine nucleoside reverse transcriptase inhibitor with activity against HIV type 1. Some (similar to 8) generic formulations of zidovudine are available in Brazil; however, based on a literature search, information concerning their bioavailability and pharmacokinetic properties in the Brazilian population has not been reported. Objective: The aim of this study was to compare the bioavailability and pharmacokinetic properties of 2 capsule formulations of zidovudine 100 mg in healthy Brazilian volunteers. Methods: This open-label, randomized, 2-way crossover study utilized a 1-week washout period between doses. Blood samples were collected for 8 hours after a single dose of zidovudine 100-mg test (Zidovudina, Fundaqdo para o Remedio Popular, Sao Paulo, Brazil) or reference formulation (Retrovir (R), GlaxoSmithKline, Philadelphia, Pennsylvania). Plasma zidovudine concentrations were determined using a validated high-performance liquid chromatography method with ultraviolet detection at 265 nm. C-max, T-max, AUC(0-t), AUC(0-infinity), t(1/2), and the elimination constant (k(e)) were determined using noncompartmental analysis. The formulations were considered bioequivalent if the 90% CIS for C-max, AUC(0-t), and AUC(0-infinity) fell within the interval of 80 % to 125 %, the regulatory definition set by the US Food and Drug Administration (FDA). Results: Twenty-four healthy volunteers (12 males, 12 females; mean age, 27 years; weight, 60 kg; height, 167 cm) were enrolled and completed the study. The 90% CIs of the treatment ratios for the logarithmic-transformed values of C-max, AUC(0-t), and AUC(0-infinity) were 80.0% to 113.6%, 93.9% to 109.7%, and 93.6% to 110.1 %, respectively. The values for the test and reference formulations were within the FDA bioequivalence definition intervals of 80% to 125%. Conclusions: In this small study in healthy subjects, no statistically significant differences in C-max, AUC(0-t), and AUC(0-)infinity were found between the test and reference formulations of zidovudine 100-mg capsules. The 90% CIs for the mean ratio values for the test and reference formulations of AUC(0-t), AUC(0-infinity), and C-max indicated that the reported data were entirely within the bioequivalence acceptance range proposed by the FDA of 80% to 125% (using log-transformed data).