983 resultados para Patient transfer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the diagnostic features, clinical management and the issues associated with management of a young immunocompetent male who presented with a presumed left Herpes simplex immune stromal keratitis, and ten months later, a right immune stromal keratitis associated with Herpes zoster ophthalmicus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to obtain the momentum transfer coefficient between the two phases, denoted by f and p, occupying a bi-disperse porous medium by mapping the available experimental data to the theoretical model proposed by Nield and Kuznetsov. Data pertinent to plate-fin heat exchangers, as bi-disperse porous media, were used. The measured pressure drops for such heat exchangers are then used to give the overall permeability which is linked to the porosity and permeability of each phase as well as the interfacial momentum transfer coefficient between the two phases. Accordingly, numerical values are obtained for the momentum transfer coefficient for three different fin spacing values considered in the heat exchanger experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Early detection by skin self-examination (SSE) could improve outcomes from melanoma. Mobile teledermoscopy may aid this process. OBJECTIVES To establish clinical accuracy of SSE plus mobile teledermoscopy compared to clinical skin examination (CSE) and test whether providing people with detailed SSE instructions improves accuracy. METHODS Men and women 50-64 years (n=58) performed SSE plus mobile teledermoscopy in their homes between May and November 2013 and were given technical instructions plus detailed SSE instructions (intervention) or technical instructions only (control). Within three months, they underwent a CSE. Outcome measures included: a) body sites examined, lesions photographed, and missed; b) sensitivityof SSE plus mobile teledermoscopy compared to in-person CSE using either patients or lesions as denominator, and; c) concordance of telediagnosis with CSE. RESULTS: 49 of 58 randomised participants completed the study, and submitted 309 lesions to the teledermatologist (156 intervention; 153 control group). Intervention group participants were more likely to submit lesions from their legs compared to control (p=0.03), no other differences between groups in number or site of missed lesions.11 participants (22%) did not photograph 14 pigmented lesions the dermatologist considered worthwhile photographing or requiring clinical monitoring. Sensitivity of SSE plus mobile teledermoscopy was 81.8% (95% confidence interval 64.5-93.0) using the patient as the denominator and 41.9 (27.6-56.2) using the lesion as denominator.-There was substantial agreement between telediagnosis and CSE (Kappa =0.90) accounting for differential diagnoses. CONCLUSIONS SSE plus mobile teledermoscopy is promising for surveillance of particular lesions even without provision of detailed SSE instructions, but in the format tested in this study, consumers may overlook lesions and send many non-pigmented lesions. This investigation demonstrates that high quality dermoscopic images can be taken by patients at home and for those sent, telediagnosis is highly accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelling of food processing is complex because it involves sophisticated material and transport phenomena. Most of the agricultural products such fruits and vegetables are hygroscopic porous media containing free water, bound water, gas and solid matrix. Considering all phase in modelling is still not developed. In this article, a comprehensive porous media model for drying has been developed considering bound water, free water separately, as well as water vapour and air. Free water transport was considered as diffusion, pressure driven and evaporation. Bound water assumed to be converted to free water due to concentration difference and also can diffuse. Binary diffusion between water vapour and air was considered. Since, the model is fundamental physics based it can be applied to any drying applications and other food processing where heat and mass transfer takes place in porous media with significant evaporation and other phase change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The introduction of Patient Group Directions (PGD) has changed significantly the way in which nurses can now administer prescription only medicines as a one-off for patients requiring this level of service. PGD’s are a written authority to administer drugs to patients that are not identified at the time of treatment. Aim: The aim of this project was to develop a PGD for use within an Outreach team to administer colloid boluses to patients presenting with hypovolemia. Method: Using a case exemplar this paper will discuss the development of a PGD using aspects of transitional change theory to highlight the potential barriers that were encountered. Implications for Practice: The implications for this PGD are wide reaching. First it now enables members from the nursing Outreach team to administer colloid fluid boluses to a prescribed patient cohort without the need for prescription. Second, it ensures the deteriorating patient has interventions initiated in a timely and appropriate manner to reduce inadvertent admission to high care areas. Last, it will improve inter-professional team-working and communication so much so that collaborative patient care reduces health costs and identifies earlier those patients requiring substantially greater nursing and medical input. Conclusion: The experience of developing a working PGD for fluid administration has meant that the Outreach team is able to respond to patients in a more effective way. In addition, it is the experience of developing this PGD that has enabled the team to contemplate other PGD’s in the execution of Outreach work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The evaluation of retinal image quality in cataract eyes has gained importance and the clinical modulation transfer functions (MTF) can obtained by aberrometer and double pass (DP) system. This study aimed to compare MTF derived from a ray tracing aberrometer and a DP system in early cataractous and normal eyes. METHODS: There were 128 subjects with 61 control eyes and 67 eyes with early cataract defined according to the Lens Opacities Classification System III. A laser ray-tracing wavefront aberrometer (iTrace) and a double pass (DP) system (OQAS) assessed ocular MTF for 6.0 mm pupil diameters following dilation. Areas under the MTF (AUMTF) and their correlations were analyzed. Stepwise multiple regression analysis assessed factors affecting the differences between iTrace- and OQAS-derived AUMTF for the early cataract group. RESULTS: For both early cataract and control groups, iTrace-derived MTFs were higher than OQAS-derived MTFs across a range of spatial frequencies (P < 0.01). No significant difference between the two groups occurred for iTrace-derived AUMTF, but the early cataract group had significantly smaller OQAS-derived AUMTF than did the control group (P < 0.01). AUMTF determined from both the techniques demonstrated significant correlations with nuclear opacities, higher-order aberrations (HOAs), visual acuity, and contrast sensitivity functions, while the OQAS-derived AUMTF also demonstrated significant correlations with age and cortical opacity grade. The factors significantly affecting the difference between iTrace and OQAS AUMTF were root-mean-squared HOAs (standardized beta coefficient = -0.63, P < 0.01) and age (standardized beta coefficient = 0.26, P < 0.01). CONCLUSIONS: MTFs determined from a iTrace and a DP system (OQAS) differ significantly in early cataractous and normal subjects. Correlations with visual performance were higher for the DP system. OQAS-derived MTF may be useful as an indicator of visual performance in early cataract eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this survey was to assess registered nurse’s perceptions of alarm setting and management in an Australian Regional Critical Care Unit. Background: The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. Method: A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Results: Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To reduce the natural convection heat loss from enclosures many researchers used convection suppression devices in the past. In this study a single baffle is used under the top tip to investigate numerically the natural convection heat loss in an attic shaped enclosure which is a cost effective approach. The case considered here is one inclined wall of the enclosure is uniformly heated while the other inclined wall is uniformly cooled with adiabatic bottom wall. The finite volume method has been used to discretize the governing equations, with the QUICK scheme approximating the advection term. The diffusion terms are discretized using central-differencing with second order accuracy. A wide range of governing parameters are studied (Rayleigh number, aspect ratio, baffle length etc.). It is observed that the heat transfer due to natural convection in the enclosure reduces when the baffle length is increased. Effects of other parameters on heat transfer and flow field are described in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Globally there are emerging trends for non-medical health professionals to expand their scope of practice into prescribing. The NPS Prescribing Competencies Framework and the Health Professionals Prescribing Pathway Program are recent initiatives to assist with implementation of prescribing for allied health professionals (AHPs). For AHPs to become prescribers, training programmes must be designed to extend their knowledge of medicines information and medicine management principles with the aim of optimising medicines related outcomes for patients. AIM To explore the understanding and confidence in clinical therapeutic choices for patient management of those AHPs enrolled in the Allied Health Prescribing Training Program Module One: Introduction to clinical therapeutics for prescribers, delivered by Queensland University of Technology, Brisbane. METHOD A pre-post survey was developed to explore key themes around understanding and confidence in selecting therapeutic choices for patients with varying complexities of conditions. Data were collected from participants in week one and 13 of the module via an online survey using a five-point Likert scale (1 = Strongly Agree (SA) to 5 = Strongly Disagree (SD)). RESULTS In the pre-Module survey the AHPs had a limited degree (D/SD) of understanding and confidence regarding the safe and effective use of medicines and appropriate therapeutic choices for managing patients, particularly with complex patients. This improved significantly in the post Module survey (A/SA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports a hybrid of two metal-organic semiconductors that are based on organic charge transfer complexes of 7,7,8,8-tetracyanoquinodimethane (TCNQ). It is shown that the spontaneous reaction between semiconducting microrods of CuTCNQ with Ag+ ions leads to the formation of a CuTCNQ/AgTCNQ hybrid, both in aqueous solution and acetonitrile, albeit with completely different reaction mechanisms. In an aqueous environment, the reaction proceeds by a complex galvanic replacement (GR) mechanism, wherein in addition to AgTCNQ nanowires, Ag0 nanoparticles and Cu(OH)2 crystals decorate the surface of CuTCNQ microrods. Conversely, in acetonitrile, a GR mechanism is found to be thermodynamically unfavorable and instead a corrosion-recrystallization mechanism leads to the decoration of CuTCNQ microrods with AgTCNQ nanoplates, resulting in a pure CuTCNQ/AgTCNQ hybrid metal-organic charge transfer complex. While hybrids of two different inorganic semiconductors are regularly reported, this report pioneers the formation of a hybrid involving two metal-organic semiconductors that will expand the scope of TCNQ-based charge transfer complexes for improved catalysis, sensing, electronics and biological applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only some of the information contained in a medical record will be useful to the prediction of patient outcome. We describe a novel method for selecting those outcome predictors which allow us to reliably discriminate between adverse and benign end results. Using the area under the receiver operating characteristic as a nonparametric measure of discrimination, we show how to calculate the maximum discrimination attainable with a given set of discrete valued features. This upper limit forms the basis of our feature selection algorithm. We use the algorithm to select features (from maternity records) relevant to the prediction of failure to progress in labour. The results of this analysis motivate investigation of those predictors of failure to progress relevant to parous and nulliparous sub-populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Dermatologic adverse events (dAEs) in cancer treatment are frequent with the use of targeted therapies. These dAEs have been shown to have significant impact on health-related quality of life (HRQoL). While standardized assessment tools have been developed for physicians to assess severity of dAEs, there is a discord between objective and subjective measures. The identification of patient-reported outcome (PRO) instruments useful in the context of targeted cancer therapies is therefore important in both the clinical and research settings for the overall evaluation of dAEs and their impact on HRQoL. Methods A comprehensive, systematic literature search of published articles was conducted by two independent reviewers in order to identify PRO instruments previously utilized in patient populations with dAEs from targeted cancer therapies. The identified PRO instruments were studied to determine which HRQoL issues relevant to dAEs were addressed, as well as the process of development and validation of these instruments. Results Thirteen articles identifying six PRO instruments met the inclusion criteria. Four instruments were general dermatology (Skindex-16©, Skindex-29©, Dermatology Life Quality Index (DLQI), and DIELH-24) and two were symptom-specific (functional assessment of cancer therapy-epidermal growth factor receptor inhibitor-18 (FACT-EGFRI-18) and hand-foot syndrome-14 (HFS-14)). Conclusions While there are several PRO instruments that have been tested in the context of targeted cancer therapy, additional work is needed to develop new instruments and to further validate the instruments identified in this study in patients receiving targeted therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

100 year old gasoline engine technology vehicles have now become one of the major contributors of greenhouse gases. Plug-in Electric Vehicles (PEVs) have been proposed to achieve environmental friendly transportation. Even though the PEV usage is currently increasing, a technology breakthrough would be required to overcome battery related drawbacks. Although battery technology is evolving, drawbacks inherited with batteries such as; cost, size, weight, slower charging characteristic and low energy density would still be dominating constrains for development of EVs. Furthermore, PEVs have not been accepted as preferred choice by many consumers due to charging related issues. To address battery related limitations, the concept of dynamic Wireless Power Transfer (WPT) enabled EVs have been proposed in which EV is being charged while it is in motion. WPT enabled infrastructure has to be employed to achieve dynamic EV charging concept. The weight of the battery pack can be reduced as the required energy storage is lower if the vehicle can be powered wirelessly while driving. Stationary WPT charging where EV is charged wirelessly when it is stopped, is simpler than dynamic WPT in terms of design complexity. However, stationary WPT does not increase vehicle range compared to wired-PEVs. State-of-art WPT technology for future transportation is discussed in this chapter. Analysis of the WPT system and its performance indices are introduced. Modelling the WPT system using different methods such as equivalent circuit theory, two port network theory and coupled mode theory is described illustrating their own merits in Sect. 2.3. Both stationary and dynamic WPT for EV applications are illustrated in Sect. 2.4. Design challenges and optimization directions are analysed in Sect. 2.5. Adaptive tuning techniques such as adaptive impedance matching and frequency tuning are also discussed. A case study for optimizing resonator design is presented in Sect. 2.6. Achievements by the research community is introduced highlighting directions for future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unidirectional inductive power transfer (UIPT) systems allow loads to consume power while bidirectional IPT (BIPT) systems are more suitable for loads requiring two way power flow such as vehicle to grid (V2G) applications with electric vehicles (EVs). Many attempts have been made to improve the performance of BIPT systems. In a typical BIPT system, the output power is control using the pickup converter phase shift angle (PSA) while the primary converter regulates the input current. This paper proposes an optimized phase shift modulation strategy to minimize the coil losses of a series – series (SS) compensated BIPT system. In addition, a comprehensive study on the impact of power converters on the overall efficiency of the system is also presented. A closed loop controller is proposed to optimize the overall efficiency of the BIPT system. Theoretical results are presented in comparison to both simulations and measurements of a 0.5 kW prototype to show the benefits of the proposed concept. Results convincingly demonstrate the applicability of the proposed system offering high efficiency over a wide range of output power.