923 resultados para Patient Admission


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose certain discrete parameter variants of well known simulation optimization algorithms. Two of these algorithms are based on the smoothed functional (SF) technique while two others are based on the simultaneous perturbation stochastic approximation (SPSA) method. They differ from each other in the way perturbations are obtained and also the manner in which projections and parameter updates are performed. All our algorithms use two simulations and two-timescale stochastic approximation. As an application setting, we consider the important problem of admission control of packets in communication networks under dependent service times. We consider a discrete time slotted queueing model of the system and consider two different scenarios - one where the service times have a dependence on the system state and the other where they depend on the number of arrivals in a time slot. Under our settings, the simulated objective function appears ill-behaved with multiple local minima and a unique global minimum characterized by a sharp dip in the objective function in a small region of the parameter space. We compare the performance of our algorithms on these settings and observe that the two SF algorithms show the best results overall. In fact, in many cases studied, SF algorithms converge to the global minimum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter is about essential nursing care. Because it is often referred to as basic nursing, nurses may not always perceive it as deserving of priority. Yet, how well patients are cared for has a direct effect on their sense of wellbeing and their recovery. ‘Interventional patient hygiene’ is a systematic, evidence-based approach to nursing actions designed to improve patient outcomes using a framework of hygiene, catheter care, skin care, mobility and oral care.1 This chapter focuses on the physical care, infection control, preventative therapies and transport of critically ill patients. The first two areas are closely linked: poor-quality physical care increases the risk of infection. The final areas are essential features of critical care nursing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose In the oncology population where malnutrition prevalence is high, more descriptive screening tools can provide further information to assist triaging and capture acute change. The Patient-Generated Subjective Global Assessment Short Form (PG-SGA SF) is a component of a nutritional assessment tool which could be used for descriptive nutrition screening. The purpose of this study was to conduct a secondary analysis of nutrition screening and assessment data to identify the most relevant information contributing to the PG-SGA SF to identify malnutrition risk with high sensitivity and specificity. Methods This was an observational, cross-sectional study of 300 consecutive adult patients receiving ambulatory anti-cancer treatment at an Australian tertiary hospital. Anthropometric and patient descriptive data were collected. The scored PG-SGA generated a score for nutritional risk (PG-SGA SF) and a global rating for nutrition status. Receiver operating characteristic curves (ROC) were generated to determine optimal cut-off scores for combinations of the PG-SGA SF boxes with the greatest sensitivity and specificity for predicting malnutrition according to scored PG-SGA global rating. Results The additive scores of boxes 1–3 had the highest sensitivity (90.2 %) while maintaining satisfactory specificity (67.5 %) and demonstrating high diagnostic value (AUC = 0.85, 95 % CI = 0.81–0.89). The inclusion of box 4 (PG-SGA SF) did not add further value as a screening tool (AUC = 0.85, 95 % CI = 0.80–0.89; sensitivity 80.4 %; specificity 72.3 %). Conclusions The validity of the PG-SGA SF in chemotherapy outpatients was confirmed. The present study however demonstrated that the functional capacity question (box 4) does not improve the overall discriminatory value of the PG-SGA SF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of protein and metabolite expression patterns in blood using mass spectrometry and high-throughput antibody-based screening platforms has potential for the discovery of new biomarkers for managing breast cancer patient treatment. Previously identified blood-based breast cancer biomarkers, including cancer antigen 15.3 (CA15-3) are useful in combination with imaging (computed tomography scans, magnetic resonance imaging, X-rays) and physical examination for monitoring tumour burden in advanced breast cancer patients. However, these biomarkers suffer from insufficient levels of accuracy and with new therapies available for the treatment of breast cancer, there is an urgent need for reliable, non-invasive biomarkers that measure tumour burden with high sensitivity and specificity so as to provide early warning of the need to switch to an alternative treatment. The aim of this study was to identify a biomarker signature of tumour burden using cancer and non-cancer (healthy controls/non-malignant breast disease) patient samples. Results demonstrate that combinations of three candidate biomarkers from Glutamate, 12-Hydroxyeicosatetraenoic acid, Beta-hydroxybutyrate, Factor V and Matrix metalloproteinase-1 with CA15-3, an established biomarker for breast cancer, were found to mirror tumour burden, with AUC values ranging from 0.71 to 0.98 when comparing non-malignant breast disease to the different stages of breast cancer. Further validation of these biomarker panels could potentially facilitate the management of breast cancer patients, especially to assess changes in tumour burden in combination with imaging and physical examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of admission control of packets in communication networks is studied in the continuous time queueing framework under different classes of service and delayed information feedback. We develop and use a variant of a simulation based two timescale simultaneous perturbation stochastic approximation (SPSA) algorithm for finding an optimal feedback policy within the class of threshold type policies. Even though SPSA has originally been designed for continuous parameter optimization, its variant for the discrete parameter case is seen to work well. We give a proof of the hypothesis needed to show convergence of the algorithm on our setting along with a sketch of the convergence analysis. Extensive numerical experiments with the algorithm are illustrated for different parameter specifications. In particular, we study the effect of feedback delays on the system performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to a large body of evidence, carotid endarterectomy (CEA) can prevent strokes, provided that appropriate inclusion criteria and high-quality perioperative treatment methods are utilised with low complication rates. From the patient s perspective, it is of paramount importance that the operation is as safe and effective as possible. From the community s point of view, it is important that CEA provision prevents as many strokes as possible. In order to define the stroke preventing potential of CEA in different communities, a comparison between eight European countries and Australia was performed including 53 077 carotid interventions. A more detailed evaluation was performed in Finland, the United Kingdom and Egypt. It could be estimated that many potentially preventable strokes occur due to insufficient diagnostics and CEA provision. The number of CEAs should be at least doubled in the Helsinki region. The theoretical power of CEA provision in stroke prevention varied significantly between the countries. Delay from symptom to surgery has been identified as one of the most important factors influencing the effectiveness of CEA. In 2008 only 11% of CEAs in Helsinki university central hospital (HUCH) were performed within the recommended14 days. Registered data of 673 CEAs in HUCH during 2000-2005 was analyzed. There was no systematic error that would have changed the outcome analysis. However it is important that registers are audited regularly and cross matching of different registries is possible. A previously unpublished method of combining medial mandibulotomy, neck incision and carotid artery interposition was carried out as a collaboration of maxillofacial, ear, nose and throat and vascular surgeons. Five patients were operated on with a technique that was feasible and possible to perform with little morbidity, but due to the significant risks involved, this technique should be reserved for carefully selected cases. In stroke prevention, organisational decisions seem far more important than details in interventional procedures when CEA is performed with low complication rates, as was the case in the present study. A TIA clinic approach with close co-operation between the on-call vascular surgeons, neurologists and radiologists should be available at all centres treating these patients. Patients should have a direct and fast admission to the hospital performing CEA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Psychoanalytic interpretation is normally understood as a sequence of two utterances: the analyst gives an interpretation and the patient responds to it. This paper suggests that, in the interpretative sequence, there is also a third utterance where psychoanalytic work takes place. This third interpretative turn involves the analyst’s action after the patient’s response to the interpretation. Using conversation analysis as method in the examination of audio-recorded psychoanalytic sessions, the paper will explicate the psychoanalytic work that gets done in third interpretative turns. Through it, the analyst takes a stance towards the patient’s understandings of the interpretation, which are shown in the patient’s response to the interpretation. The third interpretative turns on one hand ratify and accept the patient’s understandings, but, in addition to that, they also introduce a shift of perspective relative to them. In most cases, the shift of perspective is implicit but sometimes it is made explicit. The shifts of perspective bring to the foreground aspects or implications of the interpretation that were not incorporated in the patient’s response. They recast the description of the patient’s experience by showing new layers or more emotional intensity in it. The results are discussed in the light of Faimberg’s concept of listening to listening and Schlesinger’s concept of follow-up interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the performance of an SIR based admission control strategy in cellular CDMA systems with both voice and data traffic. Most studies In the current literature to estimate CDMA system capacity with both voice and data traf-Bc do not take signal-tlFlnterference ratio (SIR) based admission control into account In this paper, we present an analytical approach to evaluate the outage probability for voice trafllc, the average system throughput and the mean delay for data traffic for a volce/data CDMA system which employs an SIR based admission controL We show that for a dataaniy system, an improvement of about 25% In both the Erlang capacity as well as the mean delay performance is achieved with an SIR based admission control as compared to code availability based admission control. For a mixed voice/data srtem with 10 Erlangs of voice traffic, the Lmprovement in the mean delay performance for data Is about 40%.Ah, for a mean delay of 50 ms with 10 Erlangs voice traffic, the data Erlang capacity improves by about 9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key requirements for enabling real-time remote healthcare service on a mobile platform, in the present day heterogeneous wireless access network environment, are uninterrupted and continuous access to the online patient vital medical data, monitor the physical condition of the patient through video streaming, and so on. For an application, this continuity has to be sufficiently transparent both from a performance perspective as well as a Quality of Experience (QoE) perspective. While mobility protocols (MIPv6, HIP, SCTP, DSMIP, PMIP, and SIP) strive to provide both and do so, limited or non-availability (deployment) of these protocols on provider networks and server side infrastructure has impeded adoption of mobility on end user platforms. Add to this, the cumbersome OS configuration procedures required to enable mobility protocol support on end user devices and the user's enthusiasm to add this support is lost. Considering the lack of proper mobility implementations that meet the remote healthcare requirements above, we propose SeaMo+ that comprises a light-weight application layer framework, termed as the Virtual Real-time Multimedia Service (VRMS) for mobile devices to provide an uninterrupted real-time multimedia information access to the mobile user. VRMS is easy to configure, platform independent, and does not require additional network infrastructure unlike other existing schemes. We illustrate the working of SeaMo+ in two realistic remote patient monitoring application scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we present an exact theoretical analysis of an system, with arbitrary distribution of relative deadline for the end of service, operated under the first come first served scheduling policy with exact admission control. We provide an explicit solution to the functional equation that must be satisfied by the workload distribution, when the system reaches steady state. We use this solution to derive explicit expressions for the loss ratio and the sojourn time distribution. Finally, we compare this loss ratio with that of a similar system operating without admission control, in the cases of some common distributions of the relative deadline.