679 resultados para POLYPYRROLE FILM ELECTRODE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a case study of the Spanish dubbed version of Butch Cassidy and the Sundance Kid (George Roy Hill 1969) to illustrate and further develop the concept of L3 as a language that appears in source texts and their translations. L3 is distinguishable from the main language(s), L1 for the source text and L2 for the translation, based on a model proposed by Corrius and Zabalbeascoa 2011, and Corrius 2008. The study reveals various possible ways of rendering L3 in translation, in particular when L3 happens to coincide with L2. It also looks into the effect that certain translation solutions may have on intratextual translation and metatranslation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In addition to the two languages essentially involved in translation, that of the source text (L1) and that of the target text (L2), we propose a third language (L3) to refer to any other language(s) found in the text. L3 may appear in the source text (ST) or the target text (TT), actually appearing more frequently inSTs in our case studies. We present a range of combinations for the convergence and divergence of L1, L2 and L3, for the case of feature films and their translations using examples from dubbed and subtitled versions of films, but we are hopeful that our tentative conclusions may be relevant to other modalities of translation, audiovisual and otherwise. When L3 appears in an audiovisual ST,we find a variety of solutions whereby L3 is deleted from or adapted to the TT.In the latter case, L3 might be rendered in a number of ways, depending on factors such as the audience’s familiarity with L3, and the possibility that L3 inthe ST is an invented language.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, one of the most important challenges to enhance the efficiency of thin film silicon solar cells is to increase the short circuit intensity by means of optical confinement methods, such as textured back-reflector structures. In this work, two possible textured structures to be used as back reflectors for n-i-p solar cells have been optically analyzed and compared to a smooth one by using a system which is able to measure the angular distribution function (ADF) of the scattered light in a wide spectral range (350-1000 nm). The accurate analysis of the ADF data corresponding to the reflector structures and to the μc-Si:H films deposited onto them allows the optical losses due to the reflector absorption and its effectiveness in increasing light absorption in the μc-Si:H layer, mainly at long wavelengths, to be quantified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkittiin uutta teknologiaa pigmenttipäällystykseen. Tämä tekniikka on yleisesti tunnettua eräillä muilla teollisuudenaloilla. Kirjallisuustutkimuksessa on esitelty prosessia ja sen eri osatekijöitä sekä muilla aloilla tunnettuja prosessimuuttujia. Päällystyspastojen ja päällystettävien pintojen teoriaa on selvitetty uuden tekniikan ja pigmenttipäällystyksen valossa. Uuden tekniikan perusmekanismeja tutkittiin kokeellisessa osassa. Valuvan nestefilmin stabiilisuutta tutkittiin minimivirtauksen avulla. Stabiilisuustutkimuksen suorittamiseen käytettiin apuna Taguchi-matriisia DOE-ohjelmalla (Design of Experiments). Kokeiden perusteella minimivirtauksen kannalta päällystyspastalle edullisempi koostumus on kalsiumkarbonaatti- kuin kaoliinipasta. Sideaineella on pienempi osuus lateksia ja polyvinyylialkoholia parempi. Suurempi osuus pinta-aktiivista ainetta ja matala pastan kuiva-ainepitoisuus ovat suositeltuja. Tehokas ilmanpoisto päällystyspastasta on myös tärkeää lopullisen tuloksen kannalta. Koekoneella ajetuissa päällystyskokeissa havaittiin valuvan filmin ominaisuuksien tärkeys. Pienetkin kaasumäärät päällystyspastassa häiritsivät lopullisen päällysteen laatua. Päällystyspastan ilmanpoisto on avainasemassa erityisesti kun päällystetään suurella nopeudella pieniä päällystemääriä. Koeajoissa havaittiin kaikki kirjallisuudessa esitellyt rajoittavat tekijät. Kokeissa päällystettiin 400-1600 m/min nopeudella 5-20 g/m² päällystemääriä. Olosuhteet stabiilille nestefilmille vaativat edelleen kehitystä suurella nopeudella päällystettäessä. Päällysteen eroavaisuuksia verrattiin teräpäällystysmenetelmiin. Terä-päällystyksellä saadaan sileä mutta epätasaisesti peittävä pinta kun taas uuden tekniikan päällyste mukailee päällystettävän alustan topografiaa. Tasapaksun päällysteen etuna on hyvä peittävyys jo pienellä päällystemäärällä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Deep brain stimulation (DBS) is recognized as an effective treatment for movement disorders. We recently changed our technique, limiting the number of brain penetrations to three per side. OBJECTIVES: The first aim was to evaluate the electrode precision on both sides of surgery since we implemented this surgical technique. The second aim was to analyse whether or not the electrode placement was improved with microrecording and macrostimulation. METHODS: We retrospectively reviewed operation protocols and MRIs of 30 patients who underwent bilateral DBS. For microrecording and macrostimulation, we used three parallel channels of the 'Ben Gun' centred on the MRI-planned target. Pre- and post-operative MRIs were merged. The distance between the planned target and the centre of the implanted electrode artefact was measured. RESULTS: There was no significant difference in targeting precision on both sides of surgery. There was more intra-operative adjustment of the second electrode positioning based on microrecording and macrostimulation, which allowed to significantly approach the MRI-planned target on the medial-lateral axis. CONCLUSION: There was more electrode adjustment needed on the second side, possibly in relation with brain shift. We thus suggest performing a single central track with electrophysiological and clinical assessment, with multidirectional exploration on demand for suboptimal clinical responses.